Forward modeling approach to nuclear reaction cross sections: Applications in neutron inelastic scattering

The development of nuclear reaction models for the production of evaluated nuclear data has traditionally been performed by comparing measured cross sections with predictions from reaction model codes whose physical input parameters are adjusted to obtain the best agreement between measured and modeled results. To more directly probe reaction model inputs, this work introduces a forward modeling approach to experimental reaction cross-section determination, where the most important physical input parameters to reaction model calculations are obtained via 𝜒 2 minimization between measured and calculated observables. This was demonstrated using data collected by the Gamma Energy Neutron Energy Spectrometer for Inelastic Scattering (GENESIS) at the 88-inch cyclotron at Lawrence Berkeley National Laboratory, a detection array consisting of organic liquid scintillators and high-purity germanium (HPGe) detectors. Using a broad-spectrum neutron beam and a 99.98%-enriched 56 Fe target, GENESIS was used to perform a simultaneous measurement of 56 Fe 𝛾-ray production cross sections and secondary neutron energy and angle distributions. The results of the forward modeling approach to the determination of energy-differential 𝛾-ray production cross sections for the yrast 4 + → 2 + and 6 + → 4 + transitions, as well as eight other off-yrast transitions, were compared against those obtained using conventional techniques, and the results are in good agreement. In addition to discrete 𝛾-ray yield total scattered neutron energy-angular distributions as a function of incident neutron energy were also obtained using forward modeling and found to agree with evaluated data, with the exception of elastic scattering at small angles. The fitted reaction model parameters obtained through forward modeling were also used to calculate the cross section for the unobserved (𝑛, 2⁢𝑛) reaction; excellent agreement with the current evaluation was obtained, providing a validation of the predictive capabilities of the forward model approach. This work bridges the gap between nuclear data experiment and evaluation by providing a new means for extracting inelastic neutron-scattering cross sections and neutron-induced 𝛾-ray production data while directly probing reaction model physics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Possible theoretical explanations for occasional days of non-field-aligned diffusion at neutron monitor energies

It has been shown previously (Anath et al., 1973 and Kane, 1974) that 20 to 25% of days, the diffusion component of the cosmic-ray neutron diurnal anisotropy is directed more than 30 degrees away from the ecliptic projection of the interplanetary magnetic field averaged over the same 24 hours. A number of explanations for this deviation are discussed and it is concluded that transverse gradient drifts due to gradients perpendicular to the ecliptic are likely, that diurnal variations in the diffusion component of the neutron anisotropy may affect results from single stations and that the 24 hour mean interplanetary magnetic field may not be the field appropriate to the streaming equation at neutron monitor energies.

Forman, M. A.

Iridium and tantalum foils for spaceflight neutron dosimetry.

Description of a two-foil system of iridium and tantalum which can measure thermal and intermediate energy neutrons at flux densities of 1 neutron/sq cm-sec over a ten-day lunar mission (1,000,000 neutrons/sq cm). The foils are chemically inert and nontoxic, weigh less than 1 g each, and require only routine gamma pulse height analysis for activation measurement. Detection of fluences below 1,000,000 neutrons/sq cm are achieved for counts of foil activity made as late as two months following neutron exposure. Tantalum foils flown in Apollo 11 indicated a mean dose equivalent to the astronauts of less than 16 mrem from thermal plus intermediate energy neutrons, while nuclear emulsion track analysis indicated approximately 17 mrem from neutrons of energy greater than 0.6 MeV. Iridium foils flown on Apollo 12 indicated dose equivalents of 1.8 to 2.8 mrem from thermal neutrons, excluding tissue thermalized SNAP-27 neutrons.

English, R. A.

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

The response of a 300 micron silicon detector to monoenergetic neutrons determined by the use of the Monte Carlo technique

The response of a 300 micron thick silicon detector to an incident monoenergetic neutron beam is evaluated by the Monte Carlo method for the cases of both a shielded and a bare detector. The result of Monte Carlo calculation, using elastic, inelastic, and absorption reactions indicates that the response of the silicon detector to neutrons is basically due to the elastic scattering. In addition, the gamma rays generated in the shield of the detector will result in a response which is 3 or 4 orders of magnitude smaller than response to incident photons. The response of a bare silicon detector is calculated for neutron energies up to 6 MeV and bias energies from 50 to 250 KeV. It is found that the maximum response for a 300 micron thick silicon detector is less than .004 c/n within this selected neutron and bias energy range. When the pulse height defect is introduced in the calculation the results at low energy neutrons were reduced.

Tahezadeh, M.

Interpreting scattered neutron spectra on omega cryogenic implosions with measured backgrounds and higher-order scattering

Measurements of the areal density (⁠ρR⁠) of inertially confined implosions are critical to evaluate their performance. On OMEGA, ρR is inferred from measurements of the scattered neutron spectrum via neutron-time-of-flight (nTOF) and magnetic recoil spectrometer detectors. The nTOF measurements, in particular, have the ability to measure a wide range of neutron energies and thus scattering angles, with high precision. However, the neutrons that are backscattered into the detector must transit through the entire dense fuel assembly, and as a result are subject to rescattering effects, which have been heretofore neglected in the interpretation of OMEGA neutron spectra. At the backscatter edge, neglecting rescattering on OMEGA can lead to a ~10 to 20% reduction of the apparent areal density and therefore must be included in the analysis. The low ρR s on OMEGA also mean that backgrounds from non-target physics effects, such as scattering in the target chamber or slow scintillator decays, can significantly alter the measured signal. Here, we discuss how the Monte Carlo neutron spectrum postprocessor IRIS is used to include second-order scattering effects in the interpretation of the scattered neutron spectrum in OMEGA implosion experiments, and how dedicated implosion experiments are used to measure nTOF backgrounds in order to infer backscattered areal densities on OMEGA.

Deuterium

Characterizing the Experiment for Calibration with Uranium (Excalibur) neutron source for use in warhead verification

Neutron sources can play a variety of roles in warhead verification. For transmission radiography, a source of directed high energy neutrons is required, while for applications to detect fissile isotopes, sub-MeV neutrons are preferred. The Excalibur (Experiment for Calibration with Uranium) neutron source has been built and used in a variety of verification-related experiments. Excalibur is based on a commercial deuterium-tritium neutron generator specified and measured to be capable of producing 14 MeV neutrons at rates of up to 8.2 × 10 8 neutrons/s. Here, the generator is enclosed in a carbon-steel 32" diameter, 23.62" high carbon-steel cylinder that moderates the mean neutron energy to under 500 keV. This, in turn, is encased in 5%-borated polyethylene such that the entire assembly is a 48" x 48" box that is 30" tall. For radiographic applications, a narrow, tapered channel in the steel and polyethylene allows 14 MeV neutrons to stream directly from the generator to a test object. Its collimating capability is demonstrated by measuring the neutron flux profile. In the moderated mode of operation, the generator is fully enclosed in the steel, but a large section of the polyethylene is removed, providing a flux of sub-MeV neutrons from a wide range of angles. Neutron angular and spectral measurements using both a nested neutron spectrometer and a commercial liquid scintillator coupled with a 3 He detector show the expected softer neutron spectrum in moderated mode in good agreement with MCNP6 calculations. The gamma-ray spectrum from Excalibur is also in good agreement with MCNP modeling. Based on these findings, the future application of Excalibur in its two configurations is discussed.

Fissile material detection

Benchmarking fast-neutron response of 7 Li-enriched C 7 LYC scintillators: Simulations and experiment

New insights into the fast neutron response of 7 Li-enriched C 7 LYC scintillators have been obtained through detailed Geant4 simulations of 35 Cl(n,p) and 35 Cl(n, α) reactions that are primarily responsible for the fast neutron response of C 7 LYC. The light output of a 1” x1” C 7 LYC detector was simulated using the Birks equation for light quenching in scintillators. The simulations were benchmarked against neutron scattering data from a 12 C target obtained with a white neutron beam at the Los Alamos LANSCE facility and fourteen 1”x1” C 7 LYC detectors. Incident neutron energies extracted from time-of-flight measurements, and appropriate recoil corrections for the different detector angles were used to map the response of C 7 LYC to mono-energetic neutrons. Resonances in the 35 Cl(n,p) reaction cross-section below 3 MeV incident neutron energy were directly observed in C 7 LYC. The experimental data and simulations are compared with ENDF databases, as well as recent direct cross-section measurements of neutrons scattered from a 35 Cl target. In conclusion, the results suggest a scrutiny of the 35 Cl(n,p) and 35 Cl(n, α) cross sections at low energy in the ENDF library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Neutron capture on Gd and Sm in the Luna 16, G-2 soil.

Measurement of the Gd and Sm isotopic compositions in the Luna 16, G-2 soil, a sample which has the largest low energy neutron fluence yet observed in a lunar sample. The ratio of the number of neutrons captured per atom by Sm-149 to Gd-157 is 0.76, which is distinct from the value of 0.86 observed at the Apollo 11, 12, and 14 sites. This indicates a softer neutron energy spectrum at the Sea of Plenty.

Russ, G. P.

Introduction, Investigation, and Experimental Validation of a Novel Passive Neutron Spectrometer

Unfolding neutron energy spectra are instrumental for determining personal health effects and calculating dose received. This area of study is heavily researched, and Lawrence Livermore National Laboratory (LLNL) is investigating a passive neutron spectrometer for the purpose of acquiring the information needed to determine personnel dose in the event of a criticality accident. A part of this investigation is presented in this article through the examination of four experimental detector responses (DRs). These four DRs were acquired in the presence of 252 Cf, AmBe, GODIVA, and National Ignition Facility (NIF) neutron sources. An algorithm developed at LLNL was used to unfold the neutron fluence from each of the four DRs, and subsequently, fluence-to-dose conversion factors provided by the American National Standards Institute were used to calculate dose. Additionally, a multistep unfolding process was developed and employed to calculate the effects of both direct (from the source) and indirect (from room return) neutrons. The average error when unfolding the direct DR was less than 8%. The dose from 252 Cf was predicted with only 8% error. The multistep approach allowed for the identification of the low-energy neutrons in the 252 Cf, AmBe, and NIF DRs.

Nuclear Criticality Safety Program (NCSP)

Neutron moderation at IPF

We discuss here the possibility of using the Isotope Production Facility (IPF) at LANSCE to test the feasibility and performance of a graphite cube to create a neutron target. The idea of a neutron target enables the measurement of neutron induced reactions in inverse kinematics. This idea is part of the LANSCE strategy to stay a worldwide leader for neutron-induced research. The proof of-principle is the core of the LDRD project 20240004DR. The first steps are a series of activation experiments with different neutron energy distributions. Figs. 1 and 2 show a graphite cube built and simulated from pieces available at LANSCE. First activation experiments have already been performed at lower neutron energies utilizing (p,n) reactions on Li and Be.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Two-component model for cosmic-ray fluctuations at neutron monitor energies

A formal model for the fluctuations of the cosmic-ray intensity near earth is presented. For frequencies exceeding 5 x 10 to the -6 Hz, the fluctuations are due to field-aligned-anisotropy induced interplanetary 'scintillations' of cosmic rays, while for lower frequencies the effects of non-field-aligned anisotropies dominate. Cross-correlations between neutron monitor counting rates and the interplanetary magnetic field components are presented which support the model.

Jokipii, J. R.

Tantalum Experiments in Fully-Reflected Water-Moderated Triangular-Pitched U(6.90)O 2 Fuel Rod Lattices (1.02 cm Pitch)

The United States (US) Department of Energy (DOE) Nuclear Energy Research Initiative funded the design and construction of the Seven Percent Critical Experiment (7uPCX) at Sandia National Laboratories (SNL). The start-up of the experiment facility and the execution of the experiments described here were funded by the DOE Nuclear Criticality Safety Program. The 7uPCX is designed to investigate critical systems with fuel for light water reactors in the enrichment range above 5 % 235 U. The 7uPCX assembly is a water moderated and — reflected array of aluminum-clad U(6.90 %)O 2 fuel rods. Other critical experiments performed in the 7uPCX assembly are documented in LEU-COMP-THERM-078, LEU-COMP-THERM-080, LEU-COMP-THERM 096, LEU- COMP-THERM-097, LEU-COMP-THERM-101, LEU-COMP-THERM-102, and LEU-COMP-THERM-111. Applied interests in neutron-absorbing elements at epithermal and intermediate neutron energy ranges at DOE’s Hanford Site and Savannah River Site were identified through DOE Office of Environmental Management (EM) workshops and needs surveys performed in conjunction with the National Nuclear Security Administration/Nuclear Criticality Safety Program. In response, a team lead by Oak Ridge National Laboratory (ORNL) performed a study evaluating the use of 7uPCX for testing the epithermal cross sections of materials at SNL. This marked the inception of the set of experiments described here. The purpose of these experiments was to measure the effects of tantalum in nearly-critical systems. The tantalum was introduced into the fuel arrays as experiment rods within a central test region. The central test region was designed to target the epithermal neutron energy range by providing a dry cylindrical cavity constructed of aluminum and lined with 0.04 in (0.1016 cm) thick cadmium sheet. The central test region has an outer diameter of 3.75 in (9.525 cm) length of 31 in (78.74 cm) and can hold 85 tantalum rods nominally 0.25 in (0.635 cm) outside diameter and 31.25 in (79.375 cm) long. The critical experiments were done using a set of triangular-pitched grid plates fabricated for these experiments. The grid plate set accommodated a fuel array of a total of 2016 fuel rod positions on a pitch of 0.4 in (1.016 cm) in a series of 21 hexagonal rings positioned around the central test region. The fuel used in these experiments was fabricated using unirradiated 6.90 % enriched UO 2 fuel pellets from fuel elements designed to be used in the internal nuclear superheater section of the Pathfinder boiling water reactor operated in South Dakota by the Northern States Power Company in the 1960s. The fuel elements were obtained from The Pennsylvania State University where they had been stored for many years. The fuel pellets in those fuel elements were removed from the original Incoloy cladding and reclad in 3003 aluminum tubes and end caps for use in the experiments reported here. The eight cases in this experiment series were performed in 2024 in the Sandia Critical Experiments (SCX) at the Sandia Pulsed Reactor Facility by varying the number of fuel rods in the critical assembly. The personnel involved in conducting these experiments included David Ames, Elijah Lutz, Beth Hanson, Patrick Ward, Jason Soares, and Augie Chapa from SNL, as well as Mathieu Dupont and B.J. Marshall from ORNL. Case 1 had no tantalum experiment rods. Case 2 had seven tantalum rods in the center of the central test region. Case 3 had 18 tantalum rods in the third hexagonal ring of the central test region. Case 4 had 19 tantalum rods in the center of the central test region. Case 5 had 30 tantalum rods in the outer most positions of the central test region. Case 6 had 37 tantalum rods in the center of the central test region. Case 7 had 61 tantalum rods in the center of the central test region. Case 8 had 85 tantalum rods filling all positions in the central test region. All eight critical experiments are judged to be acceptable as benchmark experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors

Design of Quasi-Integral Experiments at the Flexible Neutron Source at the University of Tennessee

Nuclear reaction data libraries make use of experimental data that are differential in reaction and neutron energy for evaluation and data that are integral in reaction and energy for validation. In many cases, integral measurements can provide lower experimental uncertainties than differential measurements, but the impact of individual reactions and energies cannot generally be determined from the single experimental observable. “Quasi-integral” or “quasi-differential” measurements, which are integral in one characteristic (energy or reaction) and differential in the other, can often provide a middle ground of lower experimental uncertainties combined with some ability to unpack the impact of individual reactions or energies. Furthermore, the Flexible Neutron Source (FNS) at the University of Tennessee, Knoxville, is a new experimental facility that can perform integral and quasi-integral measurements by removing components of the integral configuration to determine the impact of specific reactions. Possible flux-averaged cross-section measurements, flux perturbation measurements, and neutron downscattering measurements are simulated here to show the value of the FNS to evaluation and validation of nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS