Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Bldg. 7930 Cell G Neutron Detector New Electronics Testing

The Cell G neutron assay system within 7930 provides an important function in the production of Californium-252 in the quantitative determination of the amount of Cf-252 present in a sample. The assay system consists of a Uranium-238 fission chamber coupled to the necessary counting electronics including preamplifier, amplifier, discriminator and counter/timer. The original electronics date back to the 1970s but were replaced back in 2011 with little documentation detailing the testing and replacement efforts. This work focused on procuring a new spare set of electronics, their subsequent testing as a backup in case any of the currently in use electronics were to fail and documentation of the existing and new setups.

Taylor, Neil [Oak Ridge National Laboratory (ORNL)↗

TINMAN Thermal Neutron Detector for Aircraft

TinMan is the first technology to continuously measure thermal neutron intensity during aircraft flight and to define this environment, an important achievement since changes to semiconductors have led electronic parts to become more sensitive to thermal nuetrons that may lead to disturbances in their operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polyethylene density uncertainty in the simulation of neutron detectors

Simulations with the Monte Carlo N-Particle® (MCNP®) code are frequently used to study neutron coincidence counters for international safeguards. Reducing sources of uncertainty enables more accurate simulations, which reduces the need for expensive or impossible measurements. Accurately specifying the density of polyethylene is crucial for accurate simulations. The density of polyethylene ranges from 0.88 to 0.97 g/cm 3 and high-density polyethylene (HDPE) ranges from about 0.944 to 0.965 g/cm 3 . The density of a specific detector should be measured exactly for the best simulations. Here, the density of the blue/white Active Well Coincidence Counter (AWCC) bulk polyethylene was measured to be 0.9594 +- 0.0013 g/cm 3 at 1-sigma confidence. The density was calculated from repeated measurements of the various polyethylene dimensions for volume, and weighing the polyethylene for the mass. The AWCC neutron detection efficiency was simulated for each polyethylene density. The relative range of efficiencies (3σ) was 3.4% for unspecified polyethylene, 0.9% for HDPE, and 0.3% for the measured density. The impact of modeling small features such as screws was also studied and was found to be a negligible 0.2%. Measuring polyethylene density can reduce its role in uncertainty from one of the largest to one of the smallest contributors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental demonstration and modeling of a robotic neutron detector with spectral and directional sensitivity for treaty verification

International safeguards and arms control agreements often require labor-intensive, intrusive onsite inspections to perform verification tasks. The ability to localize a neutron source and/or characterize a neutron field may be imperative for identifying anomalies. We are interested in the role of autonomous mobile robots, which, if designed properly, may be more effective and efficient and less intrusive than their human counterparts. Toward developing such a capability, we, for this study, have constructed the N-SpecDir Bot, comprised of three boron-coated straw detectors azimuthally-distributed within a cylinder of high-density polyethylene, which is mounted on an omni-directional robotic platform. Our N-SpecDir Bot is specifically designed to provide spectral and directional sensitivity, in addition to gross counts, by utilizing the signals from the three detectors. The detection system has been extensively characterized by MCNP modeling, which has been benchmarked to experiments conducted at the Princeton Plasma Physics Laboratory. We demonstrate the spectral and directional sensitivity experimentally and in simulation, and provide a simple yet robust method for directional measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Preliminary Comparison of Neutron Detector Sensitivities [Poster]

Nuclear data (ND) is vital to predictive simulations such as those completed with MCNP®. ND sensitivities are used to optimize the design of benchmark experiments. Diverse benchmarks (including neutron noise) are required to further our understanding of ND. Measured and simulated data of a 4.5-kg Pu sphere was used to calculate neutron noise parameters and associated ND Sensitivities

Nuclear Criticality Safety Program (NCSP)↗