Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Time Correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Identification of Final-State Neutrons in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-loaded (Gd-loaded) water Cherenkov detector located on the Booster Neutrino beamline at Fermilab. ANNIE's primary physics objectives include measuring neutron multiplicity for neutrino-nucleus interactions and performing cross-section measurements of charge current quasi-elastic and neutral current quasi-elastic processes. These measurements aim to improve neutrino energy reconstruction and reduce uncertainties in current and future neutrino oscillation experiments. Additionally, ANNIE serves as a testbed for advanced technologies such as Large Area Picosecond Photodetectors (LAPPDs) and Water-Based Liquid Scintillator, which enhance vertex resolution and enable detection below the Cherenkov threshold. By leveraging the high neutron capture cross section of Gd-loaded water, ANNIE is well positioned to observe final-state neutrons in beam-correlated neutrino interactions. To constrain the uncertainties in the neutron capture efficiency and time within the detector, we have conducted multiple calibration campaigns using an AmBe source. The AmBe source is deployed at different locations of the tank to map the neutron capture efficiency and determine the expected neutron capture time. Additionally, the AmBe calibration data are used to define the precise neutron clustering that will be useful for identifying neutron-like clusters from neutrino interaction. In this poster, we will present the current status of the AmBe neutron calibration program and the development of neutron cluster definition for the ANNIE Experiment.

Ajana, Dhavalkumar [Florida State U.]↗

Quantum Interferometry

Recently, several researchers, including yours truly, have been able to demonstrate theoretically that quantum photon entanglement has the potential to also revolutionize the entire field of optical interferometry, by providing many orders of magnitude improvement in interferometer sensitivity. The quantum entangled photon interferometer approach is very general and applies to many types of interferometers. In particular, without nonlocal entanglement, a generic classical interferometer has a statistical-sampling shot-noise limited sensitivity that scales like 1/Sqrt[N], where N is the number of particles (photons, electrons, atoms, neutrons) passing through the interferometer per unit time. However, if carefully prepared quantum correlations are engineered between the particles, then the interferometer sensitivity improves by a factor of Sqrt[N] (square root of N) to scale like 1/N, which is the limit imposed by the Heisenberg Uncertainty Principle. For optical (laser) interferometers operating at milliwatts of optical power, this quantum sensitivity boost corresponds to an eight-order-of-magnitude improvement of signal to noise. Applications are to tests of General Relativity such as ground and orbiting optical interferometers for gravity wave detection, Laser Interferometer Gravity Observatory (LIGO) and the European Laser Interferometer Space Antenna (LISA), respectively.

Dowling, Jonathan P.↗

Three-dimensional diagnostics and measurements of inertial confinement fusion plasmas

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium–tritium plasma undergoing fusion (“hotspot”), v HS . Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide v HS to better than 1 part in 10 4 and enable cross correlations with other measurements. Here we present the impact of v HS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

47 OTHER INSTRUMENTATION↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Galactic cosmic radiation model and its applications

A model for the differential energy spectra of galactic cosmic radiation as a function of solar activity is described. It is based on the standard diffusion-convection theory of solar modulation. Estimates of the modulation potential based on fitting this theory to observed spectral measurements from 1954 to 1989 are correlated to the Climax neutron counting rates and to the sunspot numbers at earlier times taking into account the polarity of the interplanetary magnetic field at the time of observations. These regression lines then provide a method for predicting the modulation at later times. The results of this model are quantitatively compared to a similar Moscow State University (MSU) model. These model cosmic ray spectra are used to predict the linear energy transfer spectra, differential energy spectra of light (charge less than or = 2) ions, and single event upsets rates in memeory devices. These calculations are compared to observations made aboard the Space Shuttle.

Badhwar, G. D.↗

Alpha-relaxation by scattering and medium-range atomic correlation in simple liquids

The relaxation dynamics of liquid and glass can be studied by inelastic x-ray or neutron scattering through the intermediate scattering function F(Q, t), where Q is the momentum transfer of scattering. Because of the time-consuming nature of these measurements, F(Q, t) is usually measured only at the first peak of the structure function S(Q), and its principal decay time is referred to as the α-relaxation time τ α . τ α is generally considered to describe the relaxation time of the bulk, which is related to viscosity and is controlled by the atomic cage around an atom. Here, through simulations on metallic liquids, we show that the α-relaxation time determined by scattering experiments does not purely reflect viscosity but is influenced by changes in spatial cooperativity. We also demonstrate that atomic caging is not exerted by the nearest neighbors but involves more cooperative atomic dynamics of the atomic medium-range order.

Glass transitions↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin-energy entanglement of a time-focused neutron

Intraparticle entanglement of individual particles such as neutrons could enable another class of scattering probes that are sensitive to entanglement in quantum systems and materials. Here, in this work, we present experimental results demonstrating quantum contextuality as a result of entanglement between the spin and energy modes (i.e., degrees of freedom) of single neutrons in a beam using a pair of resonant radio-frequency neutron spin flippers in the modulated intensity with zero effort configuration. We verified the mode entanglement by measuring a Clauser-Horne-Shimony-Holt contextuality witness S defined in the spin and energy subsystems, observing a clear breach of the classical bound of |S| ≤ 2, obtaining S = 2.40 ± 0.02. These entangled beams could enable alternative approaches for directly probing dynamics and entanglement in quantum materials whose low-energy excitation scales match those of the incident entangled neutron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Fissile Materials through Primary Cosmic Ray Interactions

Experiments performed by an LLNL team at the White Mountain Research center discovered that primary cosmic ray interactions on high-Z material produced large bursts of correlated neutrons. In fissionable material, these neutrons will start fission chains enhancing the neutron signature with a characteristic time signature. This signature could be a unique method for discovering fissionable material in challenging environments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Real-space local self-motion of protonated and deuterated water

Here, we report on the self-part of the Van Hove correlation function, the correlation function describing the dynamics of a single molecule, of water and deuterated water. The correlation function is determined by transforming inelastic scattering spectra of neutrons or x rays over a wide range of momentum transfer Q and energy transfer E to space R and time t. The short-range diffusivity is estimated from the Van Hove correlation function in the framework of the Gaussian approximation. The diffusivity has been found to be different from the long-range macroscopic diffusivity, providing information about local atomic dynamics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlated Temporal and Spectral Variability

The variability of neutron star and black hole X-ray sources has several dimensions, because of the roles played by different important time-scales. The variations on time scales of hours, weeks, and months, ranging from 50% to orders of magnitude, arise out of changes in the flow in the disk. The most important driving forces for those changes are probably various possible instabilities in the disk, though there may be effects with other dominant causes. The changes in the rate of flow appear to be associated with changes in the flow's configuration, as the accreting material approaches the compact object, for there are generally correlated changes in both the Xray spectra and the character of the faster temporal variability. There has been a lot of progress in tracking these correlations, both for Z and Atoll neutron star low-mass X-ray binaries, and for black hole binaries. I will discuss these correlations and review briefly what they tell us about the physical states of the systems.

Swank, Jean H.↗

How correlations change the magnetic structure factor of the kagome Hubbard model

The kagome Hubbard model (KHM) is a paradigmatic example of a frustrated two-dimensional model. While its strongly correlated regime, described by a Heisenberg model, is of topical interest due to its enigmatic prospective spin-liquid ground state, the weakly and moderately correlated regimes remain largely unexplored. Motivated by the rapidly growing number of metallic kagome materials (e.g., Mn 3 Sn, Fe 3 Sn 2 , FeSn, Co 3 Sn 2 S 2 , Gd 3 Ru 4 Al 12 , and AV 3 Sb 5 with A = K, Rb, Cs), here we study the respective regimes of the KHM by means of three complementary numerical methods: the dynamical mean-field theory, the dynamical vertex approximation, and determinant quantum Monte Carlo. In contrast to the archetypal square lattice, we find no tendencies toward magnetic ordering, as magnetic correlations remain short-range. Nevertheless, the magnetic correlations undergo a remarkable crossover as the system approaches the metal-to-insulator transition. The Mott transition itself does not affect the magnetic correlations. Our equal-time and dynamical structure factors can be used as a reference for inelastic neutron scattering experiments on the growing family of metallic kagome materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of n-p correlations in the reaction of relativistic neon with uranium

We report a preliminary measurement of coincident neutron-proton pairs emitted at 45 degrees in the interaction of 400, 530, and 650 MeV/A neon beams incident on uranium. Charged particles were identified by time of flight and momentum, as determined in a magnetic spectrometer. Neutral particles were detected using a thick plastic scintillator, and their time of flight was measured between an entrance scintillator, triggered by a charged particle, and the neutron detector. The scatter plots and contour plots of neutron momentum vs. proton momentum appear to show a slight correlation ridge above an uncorrelated background. The projections of this plane on the n-p momentum difference axis are essentially flat, showing a one standard deviation enhancement for each of the three beams energies. At each beam energy, the calculated momentum correlation function for the neutron-proton pairs is enhanced near zero neutron-proton momentum difference by approximately one standard deviation over the expected value for no correlation. This enhancement is expected to occur as a consequence of the attractive final state interaction between the neutron and proton (i.e., virtual or "singlet" deuterons). The implications of these measurements are discussed.

NASA Program Space Medicine↗

A Lumped Stochastic Model of Coupled Neutronic Assemblies

The objective of the present work is to apply the Harris ansatz to coupled assemblies in a lumped setting, i.e., ignoring the neutron phase dependence, which hitherto has not been considered. A Master equation for the single-time joint distribution of neutron number in each assembly, accounting for transfer of neutrons from one assembly to another via leakage transition probabilities and intercept or view factors is derived from which equations for the mean and variance in each assembly are developed. Because of the neutronic coupling, it is necessary to additionally compute the correlation function between pairs of assemblies which gives an expanded set of moment equations to solve. The reactivity of each assembly is allowed to vary with time, although a formal mechanism that is responsible for reactivity coupling between assemblies is not considered or proposed. Following Harris, it is then hypothesized that the number distribution in each assembly is a gamma distribution with assembly-specific mean and variance computed exactly from the moment equations. Illustrative numerical results are presented for the moments of a system of four coupled assemblies under various reactivity and neutronic coupling scenarios. The gamma distribution is then used to compute the probability that the neutron population exceeds a threshold value in any assembly. The report concludes with a discussion of recommended further work on this problem.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spent fuel nondestructive assay integrated characterization from active neutron, passive neutron, and passive gamma

Spent nuclear fuel comprises a wide range of irradiated isotopic material compositions, and characterization through nondestructive measurements is beneficial in verifying declared parameters before the fuel is placed in storage, final disposal, and/or reprocessed. This paper discusses results from three nondestructive assay instruments, including passive gamma, passive neutron, and active neutron methods, that measured fifty spent fuel assemblies at the Clab interim storage facility in Sweden. Here, integrated analysis of the measurements from the three different instruments allowed parametric assessments of cooling time, burnup, neutron multiplication, fissile mass, initial enrichment, and decay heat of each individual fuel assembly. Passive gamma measurements were found to be the most beneficial in predicting cooling time, passive neutron for determining burnup, active neutron in estimating initial enrichment, and both passive and total neutron for multiplication correlations. Fissile mass was best estimated using any combination of any two of the instruments such that corrections for isotopic changes in the fuel could be accounted for with the first set of measurements and multiplication of the assembly in the second. In conclusion, the nondestructive assay technologies demonstrated through this effort enhance the characterization of spent nuclear fuel assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MARIE Measurements and Model Predictions of Solar Modulation of Galactic Cosmic Rays at Mars

Recent data from the MARIE (Martian Radiation Environment Experiment) instrument on board the 2001 Mars Odyssey spacecraft currently in Mars orbit are presented. It is shown that the short-term modulations of galactic cosmic rays (GCR) are well described by correlating the so lar modulation parameter, <1>, with Earth-based neutron monitor counts using a 85-day time lag and the NASA Models - HZETRN (High Z and Energy Transport) and QMSFRG (Quantum Multiple Scattering theory of nuclear Fragmentation). The dose rates observed by the MARIE instrument are within 10% of the model calculations.

Saganti, P. B.↗