Strategy to Develop a Control Scheme for Core Thermal Performance Optimization

This report outlines a three-year research plan for optimizing reactor core thermal performance through use of a Digital Twin (DT) model and a set of neutron detectors to correspondingly adapt the reactor control strategy. It identifies reactor features and achievable neutron measurements that factor into this optimization task. It considers spatial effects that are important and how they can be managed by a real-time algorithm that controls reactivity actuators. The report presents a set of tasks, along with corresponding methods, for accomplishing this objective. The final task in this set is to validate the combined optimization procedure in the Purdue University’s PUR-1 reactor, for which we have an agreement of understanding. Additionally, we describe an alternative approach for overcoming some of the limitations inherent in the above approach, which includes the computational costs of high-fidelity simulations and achievable integration of neutron measurements into the DT. The proposed algorithms lower the technology readiness level (TRL) of the overall approach as some additional analysis and the development of a new neutron detector concept are necessary. In particular, a sensor measuring the gradient of the neutron flux is required, and the prototype is expected to be validated in the PUR-1 reactor. The potential benefits and the opportunity to significantly push forward the state-of-the-art make this approach worthy of further exploration in the upcoming years.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of Time-Dependent Reactor and Sensor Physics on Core Power Synthesis (Rev.1)

Online synthesis of power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins and to provide essential knowledge associated with the burnup of the fuel. In light-water reactors, power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report examines the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a pressurized water reactor (PWR), considering the typical low-enriched uranium (LEU, 3%-5% enrichment) fuel cycle as well as the higher enrichment LEU+ (5%-8% enrichment) fuel cycle. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative PWR LEU core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used as well to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori power distribution assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters and the extended nature of the LEU+ fuel cycle in comparison with LEU. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly underapproximated or overapproximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumptions leads to severe levels of error, approaching 25% at maximum (for LEU). The authors also discovered that V SPNDs are extraordinarily robust in both the LEU and LEU+ fuel cycles considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assembly and Functional Test of NRAD Heated Instrumentation Rig

This is a technical report (TEV-4296) which documents the configuration and materials of construction for a heated sensor test conducted in the NRAD reactor. It is being reviewed for external release so that operators of university reactors can evaluate whether this level of documentation will be acceptable for similar tests conducted in their reactors. The Objective section of this TEV is reproduced below. The purpose of this TEV is to document assembly and functional testing of a device which is designed to allow advanced sensors to be temporarily placed at the periphery of the NRAD reactor. While in this location, the operational characteristics of the sensors can be evaluated while they are exposed to a neutron flux. This device (or “rig”) consists of a cartridge heater surrounded by six guide tubes, which are in turn surrounded by insulation and an aluminum dry tube. The heater allows for the sensors to be tested while at elevated temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Time Dependent Reactor and Sensor Physics on Core Power Synthesis

Online synthesis of the power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins, and to provide essential knowledge associated with the burnup of the fuel. In light water reactors (LWRs), power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report aims to study the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a LWR. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative pressurized water reactor low-enriched uranium (LEU) core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used, as well, to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative (PBI) method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly under- or over-approximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumption leads to severe levels of error, approaching 25% at maximum. The authors also discovered that V SPNDs are extraordinarily robust in the low-enriched uranium fuel cycle considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of sub-micron UCN position resolution using room-temperature CMOS sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

10B nanometer thin film↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

Initial evaluation of a multimodal diamond sensor for simultaneous temperature and radiation measurements

Several experimental disciplines require simultaneous neutron flux and temperature monitoring. This paper provides the groundwork on a diamond sensor concept that could be used in harsh environments where the limits of current technologies are exceeded. Here, we present initial results on the functionality of a multimodal diamond sensor, which can simultaneously sense the presence of alpha particles at a few counts per second at temperatures up to 494 K. Such a sensor may also have applications where both charged particles or neutron detection and temperature measurement are simultaneously desired.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Distributed Fiber Sensors With High Spatial Resolution in Extreme Radiation Environments in Nuclear Reactor Cores

This paper is a comprehensive experimental report on the neutron radiation effects of distributed optical fiber sensors with enhanced Rayleigh scattering profiles in an in-pile environment. Femtosecond laser direct writing was used to inscribe Type-II modifications in standard telecom fibers and radiation-hardened fibers with fluorine-doped cores. Rayleigh backscattering signals were enhanced for continuous 1.5 m. In-pile lead-out sensors tests were carried out at the MIT Research Reactor for two months, which was operated at a nominal power of 5.7 MW with fast neutron (>0.1 MeV) flux of 1.29 × 1014 n/cm2/s and an in-core temperature of up to 560°C. Using the Optical Frequency Domain Reflectometry technique, the backscattering profiles of fiber sensors were interrogated with a 3-cm spatial resolution to monitor the temperature profile of the reactor. Results show that laser inscribed Type-II modifications in the form of nanogratings are highly stable against extreme temperature and ionizing radiation. Both standard telecom fibers and radiation-hardened fibers with laser-enhanced Rayleigh profiles can continuously perform distributed temperature measurements over the entire duration of the in-pile testing. Temperature coefficients of sensors and spectral shift quality were studied as functions of total radiation fluence. To the best of our knowledge, we present for the first time, the temperature profile of an operating nuclear reactor core with 3-cm spatial resolution, enabled by distributed fiber sensors with laser-enhanced Rayleigh scattering profiles. The high spatial resolution measurements can provide valuable data for the design and validation of digital twin and virtual reality of nuclear energy systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status Update on the Development of Transducers and Bonding Techniques for Enabling Acoustic Measurements of Damage in Microreactor Components

This report provides an overview of potential sensors and sensor-bonding techniques to enable the online acoustic interrogation of microreactor components and enhance structural health monitoring capabilities. The report focuses primarily on optical fiber–based acoustic sensors and describes initial experimental progress toward the deployment of these sensors for microreactor applications. The general approach is to monitor the resonant frequencies of microreactor components and search for evidence of structural defects that could indicate imminent failure. If properly identified, then the components could be repaired during the next reactor outage to prevent costly unplanned shutdowns. The ability to monitor the structural health of components could also reduce the need for time-consuming visual inspections and reduce staffing to improve microreactor economic viability. Increased sensor density is also one of the first steps to moving toward eventual semiautonomous operation. The expected microreactor conditions in which acoustic sensors must survive are characterized, including temperatures, neutron fluences, thermomechanical strains, and vibrational frequencies. Optical fiber–based acoustic sensors are identified as an attractive candidate for acoustic monitoring because of their high accuracy, immunity to electromagnetic interference, and resiliency in high-temperature, high-radiation environments. Optical fiber–based intrinsic sensors, such as type-II fiber-Bragg gratings and Fabry-Pérot Cavities (FPCs), are particularly attractive for a microreactor environment because of their high temperature stability, and FPCs also enable higher frequency interrogation with a lower sensitivity to radiation-induced drift. This report describes multiple interrogation systems, but the best interrogation system for a given situation will depend on the specific microreactor application, including the desired acoustic vibrational amplitudes, modes, and resonant frequencies. Initial experiments included fabricating three FPCs, tack-welding these FPCs to stainless-steel pipes or rods and performing room-temperature acoustic sensing tests to capture the vibrational frequency content. Peaks were identified in the measured frequency spectra and compared with the theoretical fundamental frequencies obtained from Euler-Bernoulli beam theory. Two of the three FPCs measured vibrational frequencies that generally matched those obtained from theory. Future work will include similar testing on pipes or other microreactor components with intentional flaws to evaluate the ability to determine changes in resonant frequencies. Finally, these tests will be repeated at high temperatures, potentially with an applied thermomechanical stress, to include environmental conditions similar to those for a microreactor application.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Wireless Instrumented RB Experiment Preliminary Design and Analysis

The ability to deploy new nuclear fuels for current or future reactor concepts requires carefully designed experiments to generate data to support fuel qualification. Ideally these experiments would include state of-the-art sensing to maximize the amount of in situ data that can be collected during operation. Furthermore, advanced reactor systems can take advantage of integrated in-core sensing technologies to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator’s understanding of limiting peaking factors. Before any novel sensing technologies can be readily adopted for nuclear applications, they must first demonstrate acceptable performance in test reactors. This report summarizes the preliminary design and analysis of the most highly instrumented irradiation experiment ever performed in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The Wireless Instrumented RB Experiment 2021 (WIRE-21) will test a wide range of sensors including wireless sensors being developed by Westinghouse Electric Company (WEC) that could provide in situ measurements of peak fuel temperatures and fuel rod pressurization due to fission gas release. The ability to wirelessly transmit a signal through the fuel rod’s cladding is critical to improving fuel monitoring capabilities without requiring signal penetrations through the cladding pressure boundary, which would significantly impact fuel fabrication, handling, and operation. Other sensors that will be tested in WIRE-21 include an array of thermocouples, self-powered neutron detectors (SPNDs), and spatially distributed fiber-optic temperature sensors. More generally, WIRE-21 will establish a flexible irradiation vehicle design to allow accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. This report summarizes the mechanical design for WIRE-21, the experimental test matrix, initial neutronic and thermal design analyses, and the active monitoring and control system enhancements necessary to support testing of advanced sensor technologies. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) relevant to light water reactors (LWRs), but the flexible design of the experiment vehicle allows much higher operating temperatures (>1,100°C). Neutronic calculations determine the neutron flux conditions as well as the nuclear heating within the experiments. These results are used as inputs to detailed thermal finite element calculations, which are required to evaluate the complex, three-dimensional heat transfer that occurs within WEC’s wireless sensor enclosures. Initial results show that the temperatures of the sensors’ enclosures and the metal bellows can be operated near the temperature range of LWR coolants and cladding while simultaneously increasing the temperature of a surrogate fuel material to values in the range of 800–1200°C to simulate centerline fuel temperatures during LWR operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Space to Air High-Altitude Region Adjoint Neutron Transport

Neutrons from an atmospheric nuclear explosion can be detected by sensors in orbit. Current tools for characterizing the neutron energy spectrum assume a known source and use forward transport to recreate the detector response. In realistic scenarios the true source is unknown, making this an inefficient, iterative approach. In contrast, the adjoint approach directly solves for the source spectrum, enabling source reconstruction. The time–energy fluence at the satellite and adjoint transport equation allow a Monte Carlo method to characterize the neutron source’s energy spectrum directly in a new model: the Space to High-Altitude Region Adjoint (SAHARA) model. A new adjoint source event estimator was developed in SAHARA to find feasible solutions to the neutron transport problem given the constraints of the adjoint environment. This work explores SAHARA’s development and performance for mono-energetic and continuous neutron energy sources. In general, the identified spectra were shifted towards energies approximately 5% lower than the true source spectra, but SAHARA was able to capture the correct spectral shapes. Continuous energy sources, including real-world sources Fat Man and Little Boy, resulted in identifiable spectra that could have been produced by the same distribution as the true sources as demonstrated by two-dimensional (2D) Kolmogorov–Smirnov tests.

LaMere, Zachary W.↗

Integrated Circuit Design for Radiation-Hardened Charge-Sensitive Amplifier Survived up to 2 Mrad

According to the continuous development of metal-oxide semiconductor (MOS) fabrication technology, transistors have naturally become more radiation-tolerant through steadily decreasing gate-oxide thickness, increasing the tunneling probability between gate-oxide and channel. Unfortunately, despite this radiation-hardened property of developed transistors, the field of nuclear power plants (NPPs) requires even higher radiation hardness levels. Particularly, total ionizing dose (TID) of approximately 1 Mrad could be required for readout circuitry under severe accident conditions with 100 Mrad around a reactor in-core required. In harsh radiating environments such as NPPs, sensors such as micro-pocket-fission detectors (MPFD) would be a promising technology to be operated for detecting neutrons in reactor cores. For those sensors, readout circuits should be fundamentally placed close to sensing devices for minimizing signal interferences and white noise. Therefore, radiation hardening ability is necessary for the circuits under high radiation environments. This paper presents various integrated circuit designs for a radiation hardened charge-sensitive amplifier (CSA) by using SiGe 130 nm and Si 180 nm fabrication processes with different channel widths and transistor types of complementary metal-oxide-semiconductor (CMOS) and bipolar CMOS (BiCMOS). These circuits were tested under γ–ray environment with Cobalt-60 of high level activity: 490 kCi. The experiment results indicate amplitude degradation of 2.85%–34.3%, fall time increase of 201–1730 ns, as well as a signal-to-noise ratio (SNR) of 0.07–11.6 dB decrease with irradiation dose increase. These results can provide design guidelines for radiation hardening operational amplifiers in terms of transistor sizes and structures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors

The goal of this work was to investigate the in-core performance of sapphire optical fiber temperature sensors and to develop clad sapphire optical fibers for in-core instrumentation. We fabricated clad sapphire optical fibers and evaluated the distributed sensing performance of these sensors via optical backscatter reflectometry under high fluence and combined radiation and temperature effects. A series of irradiations was completed to evaluate the effect of irradiation on sapphire optical fiber temperature sensors and to determine the operational limits of these sensors. (1) Objective 1: Fabricate sapphire optical fiber sensors. (2) Objective 2: Evaluate the clad sapphire fiber to verify single-mode behavior and determine and characterize the light modes supported by optical fibers. (3) Objective 3: Characterize the in-core temperature sensing of sapphire optical fiber, as well as the combined temperature and irradiation effects. (4) Objective 4: Evaluate the lifetime and performance of the sensor under irradiation to high neutron fluence. Objectives 1, 2, and 3 were completed during the first 2 years of the project. Due to the Covid pandemic, Objective 4, a high-fluence irradiation performed at the Massachusetts Institute of Technology Research Reactor (MITR), was delayed, as partner facilities were subject to mandatory shutdowns and required a 1 year, no-cost extension. This irradiation was eventually completed on December 12, 2022. This work indicates that sapphire optical fiber sensors may be a solution for ultra-high-temperature applications in which traditional silica optical fibers are prone to fail. Sapphire sensors are potentially suitable for experiments featuring temperatures above 700°C for long periods of time, or for any length of time above 1000°C. Experiments featuring a low total fluence, such as irradiations conducted in the Transient Reactor Test (TREAT) facility, also represent good applications for sapphire optical sensors. Additional work is required to characterize the sapphire fiber cladding performance, which falls outside the scope of this project, as well as the effects of high temperatures on the response of the fiber. A comprehensive material study is recommended as future work to evaluate the attenuation in sapphire under irradiation, and how that attenuation changes with irradiation temperature. The drift and attenuation in the fiber at temperatures of up to 1600°C and a total fluence of up to 2.9 x 10 17 n/cm 2 was minimal, and the fibers returned to baseline after being heated to 1600°C under irradiation. This is promising for the future use of sapphire optical fibers in advanced reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗