Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Cross Section”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Methodology for Generating Covariance Data of Thermal Neutron Scattering Cross Sections

This paper details and implements a framework for evaluating thermal neutron scattering cross sections that provide S(α,β) data and covariance data for hydrogen in light water. This methodology involves perturbing model parameters of molecular dynamics potentials and fitting the simulation results to experimental data. The framework is general and can be applied to any material or simulation method. The fit is made using the Unified Monte Carlo method to experimentally measure double-differential scattering cross sections of light water at the Spallation Neutron Source at Oak Ridge National Laboratory. Mean values and covariance data were generated for model parameters, phonon density of states, double-differential cross sections, and total scattering cross sections. These posterior parameter values were very similar to their prior values with a maximum relative error of 0.54%. This falls within in the Unified Monte Carlo–calculated uncertainties on the order of 2.7%. Additionally, posterior double-differential cross sections agree favorably with ENDF/B-VIII.0 cross sections. The new thermal scattering law was tested by comparing it against benchmarks from the International Criticality Safety Benchmark Evaluation Project Handbook, which showed a slight improvement over the ENDF/B-VIII.0 library. Additionally, the covariance matrix of the phonon density of states was validated to confirm that the spread of k eff from the density of states used to generate the covariance matrix was similar to the spread of k eff from the density of states of the sampled covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

Goetz, Callie↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

Abstract—The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Photonuclear absorption cross sections

Neutron multiplicity in photonuclear reactions; invariance of classical electromagnetism; momentum transfer models in ion collisions; cosmic ray electromagnetic interactions; quadrupole excitations in nucleus-nucleus collisons and Y-89 interactions with relativistic nuclei; and the Weizsacker-Williams theory for nucleon emission via electromagnetic excitations in nucleus-nucleus collisions are discussed.

Norbury, John W.↗

Effects of shape/phase transition regions on neutron capture cross sections

Abstract A recent study found a new, purely empirical correlation between two-neutron separation energies and neutron capture cross sections in keV neutron energy regimes. In shape/phase transition regimes, such as that near A= 150, S $$_{2n}$$ 2 n values show an anomaly—a flattening of the normal near linear decrease with neutron number. This paper addresses two questions: (1) Using this new correlation, is this anomaly in S $$_{2n}$$ 2 n values sizeable enough to produce an observable effect in capture cross sections? and (2) Can the correlation be used to quantitatively reproduce the cross sections in the transition region? It is found that the answer to both questions is in the affirmative. Possible relations to the r -process are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The new Device for Indirect Capture Experiments on Radionuclides at LANSCE: Efforts on measuring the resonance(s) responsible for the extremely large 88 Zr (n,γ) cross section

The thermal neutron capture cross section of 88 Zr was recently reported to be the second largest in nature with the largest resonance integral measured. Presumably, these very large values are caused by a resonance or resonances very near thermal energy. Determining their energies and widths, and hence the shape of the cross section away from thermal energies,is useful for applications. The short half-life (83.4 days) and associated large background, renders direct measurements of the neutron capture cross section impossible using current techniques. However, it is possible to measure the total neutron cross section, and hence the resonance properties, using the newly commissioned Device for Indirect Capture Experiments on Radionuclides (DICER) at the Los Alamos Neutron Science Center (LANSCE). Transmission measurements are utilized as a surrogate method to perform capture measurements. The 88 Zr needed for a DICER measurement was produced at the Isotope Production Facility (IPF) and cleanly separated from the production target material. A description of the new instrument, efforts and preliminary results on 88 Zr will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Finite-Geometry Corrections for Neutron Scattering Cross Section Measurements

In this report, we describe the corrections necessary for neutron scattering cross section measurements in experiments which use finite-geometry scattering samples. A new Geant4 based framework was developed to calculate these corrections which has been benchmarked against a well-measured test case. This framework also calculates the outgoing neutron energy dependence of the correction factors, which is crucial when resolving individual final states in the scatterer is not possible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total neutron cross-section measurement on CH with a novel 3D-projection scintillator detector

In order to extract neutrino oscillation parameters, long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section as a function of neutron energy is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 ± 0.05 barn.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Scattering Cross Sections: (n,n′), (n,n′γ), and (n,γ) Measurements (Final Technical Report)

This technical report discusses the outcomes from a grant to the University of Dallas in collaboration with the University of Kentucky, the United States Naval Academy and Mississippi State University to measure neutron cross sections and to provide educational opportunities in nuclear science for undergraduate and graduate students and postdoctoral scholars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining the 9 $\mathrm{Be}$($n, γ$) 10 $\mathrm{Be}$ integral cross section at fission neutron energies

The 9 B neutron capture cross section has significant implications for Be materials in the nuclear industry as well as the α process in stellar nucleosynthesis. While the cross section is well constrained at thermal neutron energies, there is a lack of experimental data at higher neutron energies, and the evaluated nuclear data libraries can differ by up to two orders of magnitude. We calculate the 9 Be(n, γ) 10 Be integral cross section at fission neutron energies in an effort to resolve disagreements amongst the nuclear data libraries. Foil irradiation experiments were performed using the Flattop critical assembly at the National Criticality Experiments Research Center with either the highly enriched U or Pu cores, with target foil stacks placed at multiple locations to exploit different neutron energy profiles. Accelerator mass spectrometry was used to measure the 10 Be/ 9 Be ratio in irradiated Be foils, while all other activation products were quantified through gamma spectrometry. The experiments were simulated using the Monte Carlo N-Particle radiation transport code and combined with experimental results to determine the total neutron fluence, while the staysl-pnnl suite and fispact-ii code were used to validate the model and assess the systematic uncertainty. The new 9 Be(n, γ) 10 Be integral cross sections calculated in this work are 26.5 ± 2.2µb at 0.59 ± 0.07 MeV, 24 ± 3 µb at 0.98 ± 0.14 MeV, 21.7 ± 1.3 µb at 1.26 ± 0.11 MeV, 21.8 ± 1.4 µb at 1.32 ± 0.11 MeV, and 18.6 ± 1.1 µb at 1.46 ± 0.13 MeV. These results do not agree with integral cross sections from any of the nuclear data library evaluations. Discrepancies between the new integral cross sections reported here and the nuclear data libraries suggest a more complex cross-section structure in the MeV range which allows for more resonance contributions, and more work is needed to further constrain the evaluated cross sections.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A computer code for predicting gamma production cross sections by neutron inelastic scattering from light nuclei

Gamma-ray production cross section by the inelastic scattering of neutrons from light nuclei are considered. The applicability of optical model potential is discussed. Based on experimental data, a cascade approach is developed to calculate the inelastic gamma production cross sections. In the case of O-16 using computer code LINGAP in conjunction with ABACUS-2; results are compared with reported values.

George, M. C.↗

Templates of expected measurement uncertainties for total neutron cross-section observables

This paper provides a template of expected uncertainties and correlations for measurements of total neutron cross-section observables by transmission. Measurements with time-of-flight and mono-energetic neutron sources are covered. The information required for evaluations in the resonance region and high energy region is detailed, along with the template of uncertainties and correlations that can be used in the absence of other information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the 73 As ⁢(𝑛,𝛾) cross section at thermal neutron energies

A measurement of the thermal neutron capture cross section of 73 As (t 1/2 = 80.3 d) was performed utilizing the University of Missouri Research Reactor. Two sealed quartz tubes containing 73 As were prepared and characterized before being irradiated for ≈1 week. The resulting production of 74 As was quantified with γ-ray spectroscopy. Monitor foils of Fe, Zr, and Mo were irradiated alongside the 73 As samples to assess the thermal and resonance region neutron fluxes. In conclusion, the thermal 73 As ⁢(𝑛,𝛾) cross section was determined to be 56.1 ± 8.9 b based on the average of the two 73 As samples and represents the first neutron-induced reaction cross section measured on 73 As.

and nuclear chemistry↗

Bayesian Monte Carlo Evaluation of Imperfect (n, 233 U) Data and Model

Conventional nuclear data evaluation methods using generalized linear least squares make the following assumptions: prior and posterior probability distribution functions (PDFs) of all model parameters and data are normal (Gaussian); the linear approximation is sufficiently accurate to minimize the cost function (even for nonlinear models); the model (e.g., of neutron cross section) and experimental data (including covariance data) are without defect and prior PDFs of parameters and measured data are known perfectly. Neglect of covariance between model parameters and measured data in conventional evaluations contributes to imperfections. These assumptions are inherent to the generalized linear least squares minimization method commonly used for resolved resonance region neutron cross section evaluations but are often not justified due to the presence of non-normal PDFs, nonlinear models (e.g., R-matrix formalism), and inherent imperfections in data and models (e.g., imperfect covariance data). Here, these assumptions are removed in a mathematical framework of Bayes’ theorem, which is implemented using the Metropolis-Hastings Monte Carlo method. Most importantly, new parameters are introduced to parameterize discrepancies between the theoretical model and measured data to quantify judgement about discrepancies or imperfections in a reproducible manner. An evaluation of 233U in the eV region using the ENDF-B/VIII.0 library and transmission data (Guber et al.) is presented, and posterior parameters are compared to those obtained by conventional evaluation methods. This example illustrates the effects of removing the most harmful assumption: that of model-data perfection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigating Gadolinium-Lined Sodium-Iodide Neutron Detectors for Mobile Applications

For enhancing the effectiveness of nonproliferation efforts in neutron detection, most portable instruments rely on 6 Li scintillators, 10 B-based detectors, or gas-filled 3 He proportional counters. Additionally, gamma-ray detectors based on scintillators and semiconductors are often employed for search applications to find radioactive material in the field. These systems typically include dedicated detectors along with separate high voltage supplies and processing electronics for the gamma-ray and neutron detectors. Ideally, a portable radiation detection system should be lightweight, compact, and cost-effective. In the field, scintillators can serve a dual purpose: (1) detecting gamma-rays and (2) detecting neutrons. Gamma-ray detection with scintillators is based on the interaction of gamma-rays within the scintillating material, whereas neutron detection depends indirectly on neutron capture events. These capture events generate conversion electrons and gamma-rays, which can interact with the scintillator. For enhancing neutron capture, the scintillator can be surrounded by neutron absorber materials with a high neutron cross section. The resulting secondary electrons and gamma-rays from neutron interactions, depending on the absorber material used, can then be analyzed to detect the presence of neutron sources. Similarly, semiconductor-based detectors can be employed along with neutron absorbers as liners for neutron detection. 158 Gd has a significantly larger neutron cross section than 3 He, commonly used in gas-filled proportional counters, as shown in Figure 1. For thermal (0.025 eV) neutrons, the absorption cross section of 158 Gd is 10,000 times greater than that of 3 He (refer to Figure 1). This feature makes naturally occurring gadolinium, which consists of 24.8% 158 Gd, a promising neutron absorber material for use in combination with gamma-ray detectors–yielding a hybrid detector–for neutron detection.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗