Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accurate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and associated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

. With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accu rate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and as sociated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

Nuclear Criticality Safety Program (NCSP)↗

A high-resolution measurement of the 2.223 MeV neutron capture line in a solar flare

An intense solar flare lasting 40 s was observed by the HEAO 3 gamma-ray spectrometer on November 9, 1979, at 3:05 UT. The flare was observed in four high-resolution germanium detectors as well as in five CsI shield detectors over an energy range of 100 keV to above 5 MeV. Of particular interest is a line feature at 2.2248 + or - 0.0010 MeV. The precise energy measurement provides unambiguous evidence that this is the (H-1)(n, gamma)(H-2) line resulting from neutron capture on hydrogen. An upper limit of 5 keV is found for the natural line width. The time dependence of the neutron capture line is discussed as well as the overall characteristics of the November 9 flare.

Prince, T. A.↗

Measurements of effective actinides neutron capture cross sections in a cadmium-filtered epithermal neutron spectrum

In this work, a total of 20 actinide samples were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL): 233 U (1), 235 U (1), 236 U (1), 238 U (1), 237 Np (2), 239 Pu (1), 240 Pu (1), 242 Pu (2), 244 Pu (2), 241 Am (2), 243 Am (2), 244 Cm (2), and 248 Cm (2). The samples were loaded in a basket containing a 1.1-mm thick cadmium filter. The presence of the filter drastically changes the neutron spectrum in the samples and accentuates the reaction rates in the resonance region. Isotopic ratios were determined using Multi-Collector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS) that allowed inferring effective capture cross sections. Detailed best-estimate MCNP models of the experiment using ENDF/B-VII.0 nuclear data were developed to calculate the effective neutron cross sections and, subsequently, compare them with the cross sections inferred from experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron Capture and Transmission Measurements and Evaluation of 54 Fe at the RPI LINAC [Slides]

This presentation covers neutron capture and transmission measurements and evaluation of 54 Fe (Iron) at the Rensselaer Polytechnic Insitute (RPI) Linear Accelerator (LINAC). Presentation conclusions find that 54 Fe is near its conclusion, covariance matrix generation is needed for both experiments before data is made available and released (Completion by April 2023). RPI will be conducting a full Resolved Resonance Region (RRR) evaluation following release of data (Completion by September 2023). Additionally, the neutron beam imager shows promise in providing an easy way to align samples in the most intense part of the neutron beam and there will be a new evaluation that will offer improvements in crit safety, shielding, and stellar applications.

07 ISOTOPE AND RADIATION SOURCES↗

The calculation of neutron capture gamma-ray yields for space shielding applications

The application of nuclear models to the calculation of neutron capture and inelastic scattering gamma yields is discussed. The gamma ray cascade model describes the cascade process in terms of parameters which either: (1) embody statistical assumptions regarding electric and magnetic multipole transition strengths, level densities, and spin and parity distributions or (2) are fixed by experiment such as measured energies, spin and parity values, and transition probabilities for low lying states.

Yost, K. J.↗

Stellar s-process neutron capture cross sections on 78,80,84,86 Kr determined via activation, atom trap trace analysis and decay counting

We present a detailed account of neutron capture experiments of astrophysical relevance on 78,80,84,86 Kr (n, γ) reactions at the border between weak and main s process. The experiments were performed with quasi-Maxwellian neutrons from the Liquid-Lithium Target (LiLiT) and the mA-proton beam at 1.93 MeV (2-3 kW) of the Soreq Applied Research Accelerator Facility (SARAF). The setup yields high-intensity approximate to 40 keV quasi-Maxwellian neutrons (3-5 x10 10 n/s) closely reproducing the conditions of s-process stellar nucleosynthesis. A sample of 100 mg of atmospheric, pre-nuclear-age Kr gas contained in a Ti spherical shell was activated in the LiLiT neutron field. The abundances of long-lived Kr isotopes ( 81,85g Kr) were measured by atom counting via atom trap trace analysis (ATTA) at Argonne National Laboratory and low-level counting (LLC) at University of Bern. This work is the first measurement of a nuclear cross section using atom counting via ATTA. The activities of short-lived Kr isotopes ( 79,85m,87 Kr) were measured by gamma-decay counting with a high-purity germanium detector. Maxwellian-averaged cross sections for s-process thermal energies are extracted. By comparison to reference values, our nucleosynthesis network calculations show that the experimental cross sections have a strong impact on calculated abundances of krypton and neighboring nuclides, in some cases improving agreement between theory and observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed Neutron Capture for Monitoring CO 2 Storage with Enhanced Oil Recovery in Northern Michigan

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. Pulsed neutron capture (PNC) logging has been used as part of the MRCSP monitoring of CO 2 injection and storage during assessment of enhanced oil recovery (EOR) in several Northern Niagara Pinnacle Reef Trend (NNPRT) reefs in Michigan. This technique and data processing cost less than traditional fluid sampling and presents a low risk to well operations by utilizing through-tubing logging capabilities. Additionally, monitoring CO 2 migration and break-through can be conducted from a single monitoring well in the reservoir. A total of four reefs were selected for these studies to monitor CO 2 migration and to test the viability and effectiveness of the PNC technology for saturation monitoring in a low porosity and highly diverse lithology environment. This study provides assessment of the technology and recommendations for utilization of saturation analysis.

01 COAL, LIGNITE, AND PEAT↗

Neutron-Capture Kr-80 and Ar-36 in the Martian Atmosphere and Regolith

We calculate that approximately 10% of martian atmospheric Kr-80 formed by neutron capture on Mars in approx. 0.5 Ga. The regolith contains even larger amounts of n-capture Kr-80 and Ar-36, which may provide clues to the evolution of the martian regolith and atmosphere. Additional information is contained in the original extended abstract.

Rao, M. N.↗