Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Net Zero Energy Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Assessment of the Technical Potential for Achieving Net Zero-Energy Buildings in the Commercial Sector

This report summarizes the findings from research conducted at NREL to assess the technical potential for zero-energy building technologies and practices to reduce the impact of commercial buildings on the U.S. energy system. Commercial buildings currently account for 18% of annual U.S. energy consumption, and energy use is growing along with overall floor area. Reducing the energy use of this sector will require aggressive research goals and rapid implementation of the research results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel Variable Refrigerant Flow (VRF) heat recovery system model: Development and validation

As one of the latest emerging HVAC technologies, the Variable Refrigerant Flow (VRF) system with heat recovery (HR) configurations has obtained extensive attention from both the academia and industry. Compared with the conventional VRF systems with heat pump (HP) configurations, VRF-HR is capable of recovering heat from cooling zones to heating zones and providing simultaneous cooling and heating operations. Moreover, this could lead to substantial energy saving potential and more flexible zonal control. In this paper, a novel model is developed to simulate the energy performance of VRF-HR systems. It adheres to a more physics-based development with the ability to simulate the refrigerant loop performance and consider the dynamics of more operational parameters, which is crucial for representing more advanced control logics. Another key feature of the model is the introduction of component-level curves for indoor units and outdoor units instead of overall performance curves for the entire system, and thus it requires much fewer user-specified performance curves as model inputs. The validation study reflects good agreements between the simulated energy use from the new VRF-HR model and the laboratory measurement data across all operational modes at sub-hourly time steps. The model has been adopted in the official release of the EnergyPlus simulation program since Version 8.6, which enables more accurate and robust assessments of VRF-HR systems to support their applications in energy retrofit of existing buildings or design of zero-net-energy buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Support Document: Development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings - 50% Energy Savings

This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-MBBR) ASHRAE et al. (2011b). The AEDG-MBBR is intended to provide recommendations for achieving 50% whole-building energy savings in retail stores over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-MBBR was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technical Support Document: Development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings - 50% Energy Savings

This Technical Support Document describes the process and methodology for the development of the Advanced Energy Design Guide for Medium to Big Box Retail Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-MBBR) ASHRAE et al. (2011b). The AEDG-MBBR is intended to provide recommendations for achieving 50% whole-building energy savings in retail stores over levels achieved by following ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-MBBR was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IES), the U.S. Green Building Council (USGBC), and the U.S. Department of Energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost Analysis of Annual and Monthly Net Zero Energy Performance for Multifamily Buildings in the United States

As the United States continues its progress toward sustainable construction, net zero building design is becoming an increasingly important and popular topic. Two definitions of net zero energy performance, monthly and annual, provide different levels of energy autonomy and efficiency within a building. This article analyzes the viability and incremental cost for two-, three-, and four-story multifamily apartment buildings to reach both annual and monthly net zero energy performance throughout four climate zones in the United States using baseline reference buildings that represent current construction practices. Building size plays a large role in determining the capability for a building model to reach annual or monthly net zero. Two-story buildings are capable of reaching annual net zero with an increase in construction cost of about 4.4–5.6%. Three-story buildings in warmer climates can achieve annual net zero with an increase of about 5.1%, but models in colder climates cannot reach annual net zero performance. Four-story buildings cannot achieve net zero, owing to insufficient building area for solar arrays to produce electricity. Monthly net zero energy performance was significantly harder to achieve, with the only case reaching this goal being the two-story Houston based model, at an added cost of 8.2%. Generally speaking, only small buildings in warm climates will be able to achieve monthly net zero without vastly oversizing photovoltaic systems and increasing costs without adequate payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

State-of-the-Art Analysis of Nearly Zero Energy Buildings

The IEA HPT Annex 49 "Design and integration of heat pumps for Nearly Zero Energy Buildings" deals with the design and integration of heat pumps as core component of the HVAC system for Nearly or Net Zero energy buildings (NZEB).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient Low-Lift cooling with Radiant Distribution, Thermal Storage and Variable-Speed Chiller Controls

The U.S. Department of Energy’s Building Technologies Program goal is to develop cost-effective technologies and building practices that will enable the design and construction of net-zero energy buildings by 2025. To support this goal, Pacific Northwest National Laboratory evaluated an integrated technology that through utilization of synergies between emerging heating, ventilation and air conditioning systems can significantly reduce energy consumption in buildings. This set consists of thermal storage, dedicated outdoor air system, radiant heating/cooling with a variable speed low-lift-optimized vapor compression system. The results show that the low-lift cooling system provides significant energy savings in many building types and climates locations. This market represents well over half of the entire U.S. commercial building sector. This analysis shows that significant cooling system efficiency gains can be achieved by integrating low-lift cooling technologies. The cooling energy savings for a standard-performance building range from 37% to 84% and, for a high-performance building, from -9% to 70%.

25 ENERGY STORAGE↗

Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications

Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by first overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrification of buildings and industry in the United States: Drivers, barriers, prospects, and policy approaches

The report offers several use cases and case studies of electrification in buildings and industry: air source heat pumps for space heating, zero net energy buildings, electric water heaters and demand response, electric arc furnaces, and electric boilers. Finally, the report suggests several areas for further research to better understand and advance beneficial electrification.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost-Effective Integration of Efficient Low-Lift Base Load Cooling Equipment

The long-term goal of DOE’s Commercial Buildings Integration subprogram is to develop cost-effective technologies and building practices that will enable the design and construction of net Zero Energy Buildings — commercial buildings that produce as much energy as they use on an annual basis — by 2025. To support this long-term goal, DOE further called for — as part of its FY07 Statement of Needs — the development by 2010 of “five cost-effective design technology option sets using highly efficient component technologies, integrated controls, improved construction practices, streamlined commissioning, maintenance and operating procedures that will make new and existing commercial buildings durable, healthy and safe for occupants.” In response, PNNL proposed and DOE funded a scoping study investigation of one such technology option set, low-lift cooling, that offers potentially exemplary HVAC energy performance relative to ASHRAE Standard 90.1-2004. The primary purpose of the scoping study was to estimate the national technical energy savings potential of this TOS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Federal New Buildings Handbook for Net Zero Energy, Water, and Waste

In 2015, the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE) defined zero energy buildings as "an energy-efficient building where, on a source energy basis, the actual annual delivered energy is less than or equal to the on-site renewable exported energy." This document is focused on applying EERE’s definition of zero energy buildings to federal sector new buildings. However, it is not intended to replace, substitute, or modify any statutory or regulatory requirements and mandates.

federal new buildings↗

A biophysical approach to the performance diagnosis of human–building energy interaction: Information (bits) modeling, algorithm, and indicators of energy flow complexity

Highlights: • Energy-related human-building interaction is analyzed at the biophysical system scale. • Energy flow-networking model of environmental building performance is suggested. • Information is suggested as a holistic building performance metric. - Abstract: This article addresses the utmost upstream impacts of human–building energy interaction by proposing a network-based model, algorithms, and indicators. Hypothesizing that human behavior is a key factor for the symbiotic development of building and the geobiosphere system, the author seeks emergy (spelled with an “m”)-information integrated measures to indicate dynamic system-level performance of the interaction with building energy flow topology. To validate the hypothesis and methods, four representative building cases were tested on the building form (envelope) of (i) a building with no occupant intervention (baseline), (ii) a building controlled by responsive human behavior (bioclimatic adaptation), (iii) a building with reinforced insulation and behavior-dominated control (passive design), and (iv) a net-zero energy building (NZEB). The results demonstrate that adaptive human behavior in building operation increases the information content and complexity of energy-flow networking, improving performance and sustainability. Findings also reveal that increasing information, complexity, and power (energy availability over time) parallel the general energetic features of developing biophysical systems (greater feedback, internalization, and recycling of materials and energies). It becames clear that active behavioral response is a dominant agent of sustainable environments even on a far broader system scale.

54 ENVIRONMENTAL SCIENCES↗