At least 55 records · Page 3

Scale effects on core design, fuel costs, and spent fuel volume of pressurized water reactors

The desire to improve the economic competitiveness and deployment pace of nuclear energy through modularization, manufacturing, and series production had led to the development of smaller size reactors. As the standard 17x17 fuel technology is mainly maintained in the pressurized water reactors (PWRs) category, this translates into a lower number of fuel assemblies in the core and sometimes a reduced fuel height. To assess the impact of such scale change in core design on fuel cycle cost and spent fuel volume, a scoping analysis tool is developed based on infinite lattice calculations, leakage, fuel management reduced models, and levelized unit cost of electricity (LCOE) estimate. As such, cost dynamics driven by fuel specific power, burnup, core leakage, feed, cycle length, fuel assembly height as well as uranium market data are captured with consistent set of assumptions and analysis methods. A selection of 5 reactor designs representative of leading PWR developers is assessed and compared. Pursuing higher specific powers and optimal burnups are highlighted as the main fuel cost reduction drivers, nevertheless, practical limitations and opportunities must be evaluated to establish the feasibility of such enhanced fuel operation. In consequence, a detailed core design is performed using SIMULATE3 code for 5 PWR variations including natural and forced coolant circulation modes, two reactor scales, power densities of 73, 112, and 123 kW/l and higher discharge burnups. Design and optimization are performed at the lattice level, for the reflector, and at the core loading level. Satisfactory steady-state operation including power distribution, coolant operating limits, and reactivity requirements are analyzed and reported in this paper. The fuel economics of the detailed core designs confirm the scoping analysis findings. Despite the unlocked power uprates in small PWRs, the achievable burnup for a given fuel specific power requires more enrichment and shorter fuel height results in higher fabrication costs per mass of fuel, which makes scaling down core size a more expensive endeavor on the fuel cycle front. Spent fuel volumes are reported for the PWRs designed in this paper. Furthermore, these volumes are driven by the core average discharge burnup regardless of the scale in consideration. Additional cost and core performance aspects related to heavy reflector gains, fuel-reflector substitution, and disposal cost policy in the U.S. are examined.

42 ENGINEERING↗

SPC-71260 Rev 0 MARVEL Heat Extraction Subsystem Secondary Coolant Equipment (SCE) Design/Build

A. The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. Idaho National Laboratory (INL), operated for the U.S. Department of Energy (DOE) by Battelle Energy Alliance, LLC (BEA) (Contractor hereafter) is procuring services for the design, analysis, fabrication, testing and delivery of a Secondary Coolant Equipment system (SCE). This specification contains the requirements for design, analysis, fabrication, testing and delivery of the SCE as described herein. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells.” It is intended for the IHX containment to also be filled with NaK. The MARVEL design team has determined that a Heat Extraction System (HES) using pumped NaK will be used to extract heat from the IHXs and deliver it to a downstream system for power generation or alternate process heat users. This Heat Extraction System will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. The objective of this specification is to develop the final design for the HES Secondary Coolant Equipment system (SCE) that will be used as the core of the HES. This system provides control of the NaK circulation between the MARVEL reactor and the subsequent process heat utilization systems. It does not include design of the Intermediate Heat Exchangers and piping inside the T-REXc pit in which the reactor is located. B. The MARVEL microreactor will be installed in the Transient Reactor Test Facility (TREAT) building in the Transient Reactor Test (TREAT) Micro-Reactor Experiment Cell (T-REXc) C. An INL Subcontractor has developed a conceptual design for this system per SPC-71145, referred to in that specification as the Process Heat Extraction System. SPC-71260 is based on the pumped NaK loop concept developed under SPC-71145. D. The SCE system design and (as option scope) fabrication shall be provided by the awardee of the subcontract (Subcontractor hereafter) pertaining to this Specification. Prior to shipment, the SCE will be fabricated, assembled, and tested at the Subcontractor’s facility. After successful completion of acceptance testing, the SCE and associated equipment will be shipped to the Materials and Fuels Complex (MFC) at the INL (Contractor’s Facility hereafter) to be installed by others in TREAT/T-REXc.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

SPC-71145 Rev 0 MARVEL Process Heat Extraction System Conceptual Design

The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells”. It is intended for the IHX containment to also be filled with NaK. The MARVEL design team is currently looking for alternative means of extracting heat from these wells to be utilized in downstream applications. This Heat Utilization System (HUS) will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. Depending on the methodology used, the interface between the secondary coolant and the HUS is the Process Heat Extraction System (PHES) and is the subject of this specification.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Subseasonal Tropical Convection Characteristics in the Energy Exascale Earth System Model Version 2

Accurate simulation of subseasonal tropical moist convection remains a key challenge for Earth system models. The difficulties stem from the reliance of cumulus cloud processes on model parameterizations and the need to represent the multiscale nature of interactions among clouds, radiation, moisture, circulation, and surface energy fluxes. Equatorial convection drives circulation anomalies that can affect weather patterns and extremes globally, motivating efforts to better understand and simulate these tropical disturbances. Here, a detailed review of subseasonal tropical convective behavior as simulated in the Energy Exascale Earth System Model version 2 (E3SMv2) is presented, with comparison to its predecessor version 1 (E3SMv1) and reference data sets. Model structural changes to the deep convective trigger function and surface fluxes, along with parametric tuning of the cloud and microphysics schemes, together result in an improved depiction of organized tropical convection across scales. In particular, E3SMv2 exhibits a more realistic Madden‐Julian oscillation (MJO) and low‐frequency Kelvin waves—owing to a sharper time mean equatorial meridional moisture gradient and improved convection‐circulation coupling —as well as a better depiction of MJO Northern Hemisphere teleconnections. Despite these improvements, subseasonal precipitation variance continues to be strongly underestimated in E3SMv2. Use of a cloud plume model also reveals that the coupling between daily averaged tropical precipitation and lower tropospheric instability in E3SM is inconsistent with observations, a bias that could potentially impact the simulation of intraseasonal disturbances.

54 ENVIRONMENTAL SCIENCES↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement of the background in the CMS muon detector in ${p}{p}$-collisions at $\sqrt{s} = 13$ TeV

The CMS detector, including its muon system, has been operating at the CERN LHC in increasingly challenging conditions for about 15 years. The muon detector was designed to provide excellent triggering and track reconstruction for muons produced in proton–proton collisons at an instantaneous luminosity ($\mathcal{L}$) of 1 x 10 34 cm –2 s –1 . During the Run 2 data-taking period (2015–2018), the LHC achieved an instantaneous luminosity of twice its design value, resulting in larger background rates and making the efficient detection of muons more difficult. While some backgrounds result from natural radioactivity, cosmic rays, and interactions of the circulating protons with residual gas in the beam pipe, the dominant source of background hits in the muon system arises from proton–proton interactions themselves. Charged hadrons leaving the calorimeters produce energy deposits in the muon chambers. In addition, high-energy particles interacting in the hadron calorimeter and forward shielding elements generate thermal neutrons, which leak out of the calorimeter and shielding structures, filling the CMS cavern. We describe the method used to measure the background rates in the various muon subsystems. These rates, in conjunction with simulations, can be used to estimate the expected backgrounds in the High-Luminosity LHC. This machine will run for at least 10 years starting in 2029 reaching an instantaneous luminosity of $\mathcal{L}$ = 5 x 10 34 cm –2 s –1 and increasing ultimately to $\mathcal{L}$ = 7.5 x 10 34 cm –2 s –1 . These background estimates have been a key ingredient for the planning and design of the muon detector upgrade.

Tytgat, M. (ORCID:0000000239902074)↗

Pinned Clouds over Industrial Sources of Heat during TRACER

An analysis of stereo-camera data from the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, Texas, reveals the existence of pinned clouds sitting atop industrial heat sources. These are not plumes of vapor and condensate emanating from stacks: The pinned shallow cumuli have cloud bases at about the lifting condensation of near-surface air. On many mornings, the pinned clouds are the only shallow cumuli in the field of view of the stereo cameras, persisting by themselves for at least an hour. On those mornings, the lower atmosphere straddles the boundary between stable and unstable, and the waste heat from industrial facilities is able to pin moist convection overhead. When solar heating of the surface becomes sufficient later in the morning, those mornings transition to having widespread shallow moist convection. Occurring within the field of view of the stereo cameras and other TRACER instruments, these pinned clouds represent steady plume-like moist convection triggered by known heat sources in a well-characterized atmosphere, making them a rich target for further study. Significance Statement This article introduces steady-state cumulus clouds observed during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign that were pinned to industrial heat sources. These pinned clouds were present in the early morning only when conditions were primed for moist convection, but for which there was not yet enough solar heating to trigger widespread convection. They persist in a statistical steady state and therefore provide a natural setting to explore the mechanisms controlling convective dynamics, which play a central role in Earth’s atmospheric circulation and radiative balance.

Atmosphere↗

A Dual-Active-Bridge Converter Employing a Variable Inductor Without an Auxiliary Circuit

This paper proposes a dual active bridge (DAB) converter employing a variable inductor (VI) without an auxiliary circuit. Unlike conventional VI-based designs that require an external DC bias circuit, the proposed DAB utilizes the input DC current itself as the bias source, enabling automatic inductance variation with load conditions. The inductance naturally increases at low power and decreases at high power, effectively extending the zero voltage switching (ZVS) range and reducing circulating current, respectively. The VI was experimentally implemented and characterized to obtain its inductance-current profile, which was then integrated into a PLECS model of the DAB converter for circuit and thermal simulations. Simulation results confirm that the proposed auxiliary-free VI-DAB converter achieves a wider ZVS range and lower circulating current compared with a conventional fixed-inductor DAB converter. By realizing a variable inductor without any auxiliary bias circuitry, the proposed approach maintains soft switching and reduces reactive current losses across a wide load range, leading to improved efficiency and simplified implementation.

Jo, Cheolhui [ORNL] (ORCID:0000000322692434)↗

Emergent Inductance from Chiral Orbital Currents in a Bulk Ferrimagnet

Here, we report the discovery of a new form of inductance in the bulk ferrimagnet Mn 3 ⁢Si 2 ⁢Te 6 , which features strong spin-orbit coupling, large magnetic anisotropy, and pronounced magnetoelastic interactions. Below its Curie temperature (𝑇 𝐶 ≈ 78 K), Mn 3 ⁢Si 2 ⁢Te 6 hosts chiral orbital currents (COC) that circulate within the crystal lattice and give rise to collective electronic behavior [Control of chiral orbital currents in a colossal magnetoresistance material, Nature (London) 611, 467 (2022).]. By applying a magnetic field along the hard 𝑐 axis and driving the system with low-frequency currents, we uncover a giant inductive response up to millhenry scale, originating from first-order reconfigurations of COC domains. These domains act as coherent mesoscopic inductive elements that resist reversal upon current reduction, producing a large electromotive force and sharply increasing voltage. This emergent inductance defies classical models, occurs without superconductivity or engineered nanostructures, and opens a new frontier in orbital-based quantum functionality and device concepts.

complex materials↗

Distinctive Pattern of Global Warming in Ocean Heat Content

Abstract Huge heat anomalies in the atmosphere and ocean in recent years are not yet explained. Strong characteristic patterns in temperatures for upper layers of the ocean occurred from 2000 to 2023 in the presence of global warming from increasing atmospheric greenhouse gases. Here, we show that the deep tropics are warming, although sharply modulated by El Niño–Southern Oscillation events, with strong heating in the extratropics near 40°N and 40°–45°S but little heating near 20°N and 25°–30°S. The heating is most clearly manifested in zonal-mean ocean heat content and is evident in sea surface temperatures. The strongest heating is in the Southern Hemisphere, where aerosol effects are small. Estimates are made of the contributions to heating of top-of-atmosphere (TOA) radiation, atmospheric energy transports, surface fluxes of energy, and redistribution of energy by surface winds and ocean currents. The patterns of change are not directly related to TOA radiation but are evident in net surface energy fluxes and inferred ocean heat transports, underscoring their coupled origin. Changes in the atmospheric circulation through a poleward shift in ocean jet streams and storm tracks are reflected in surface wind-driven ocean Ekman transports. As well as human-induced climate change, internal natural variability is likely in play. Hence, the atmosphere and ocean currents are systematically redistributing heat from global warming, profoundly affecting local climates. Significance Statement As the climate changes, it has been difficult to discern meaningful patterns. Distinctive patterns of change have occurred in the ocean when examined as zonal averages around latitude bands. Most excess heat from global warming resides in the ocean and, since 2005, has become focused into bands near 40°N and 40°S, with little net warming in the subtropics. The strongest warming is in the Southern Hemisphere, although sea surface temperatures have increased more in the Northern Hemisphere. Changes in the atmospheric circulation through a poleward shift in the jet stream and storm tracks are primarily responsible along with corresponding changes in ocean currents. These changes are linked through surface exchanges of energy via heat, moisture, and wind stress.

Trenberth, Kevin E. [National Center for Atmospher↗

Surface radiation trends at North Slope of Alaska influenced by large-scale circulation and atmospheric rivers

Arctic amplification manifests as a pervasive warming trend emerging over the past century in near-surface air temperature throughout the Arctic that is double the globally averaged temperature increase throughout most of the year. It results from complex processes involving oceanic, atmospheric and terrestrial components which require detailed study to discern roles of the fundamental processes involved to improve predictions of the Arctic environment. We report on signals that are beginning to emerge, on a timescale predicted by recent satellite remote sensing studies, from the unique 25 year record of detailed surface-based radiometer measurements obtained by the US Department of Energy Atmospheric Radiation Measurement (ARM) Facility North Slope of Alaska (NSA) site at Utqiaġvik, Alaska. Statistically significant warming trends are found at the site in the boreal fall, while a decrease in net radiation occurs in late summer. This decrease is driven primarily by the decrease in shortwave radiation resulting from increasing cloud liquid water path as observed by the microwave radiometer. The magnitude of the liquid water path trends is slightly larger than the root mean square error (RMSE) due to natural variability, while the magnitude of the net radiation trends is smaller than the RMSE natural variability, emphasizing that these signals are only just emerging. Analysis of prevailing meteorological regimes linking NSA with the Arctic Ocean and subarctic latitudes, and atmospheric rivers, suggests that specific changing circulation patterns are the primary driver for these summertime trends.

Lubin, Dan [Univ. of California, San Diego, CA (Un↗

Environmental Evaluation of Gas Switching Reforming for Low Carbon Hydrogen: A Power-to-X Study

Gas Switching Reforming for hydrogen production (GSR-H2) offers a promising pathway for producing low-carbon hydrogen at scale, with significant implications for Power-to-X (PtX) systems that rely on clean hydrogen as a feedstock for synthetic fuels and chemicals. GSR-H2 integrates inherent carbon capture and thermal self-sufficiency, positioning it as an efficient alternative to conventional steam methane reforming (SMR), proton exchange membrane (PEM) electrolysis, and chemical looping reforming (CLR). Unlike SMR, GSR-H2 avoids external natural gas combustion by leveraging exothermic redox cycles to generate process steam and recover electricity internally. Its innovative reactor design consolidates all reforming stages within a single reactor cluster, eliminating the need for solid circulation found in CLR, thereby reducing capital costs and improving system reliability and scalability. This presentation describes the first environmental life cycle assessment (LCA) of GSR-H2, evaluating its environmental performance across U.S. grid and renewable energy scenarios. In a renewables-powered configuration, GSR-H2 achieves a global warming potential (GWP) of 2.77 kg CO2 equivalent per kg H2, substantially lower than SMR (10.4 kg) and competitive with PEM electrolysis (1.85 kg) and CLR (1.84 kg). Results across additional impact categories, including air quality and water use, support GSR-H2’s role as a complementary hydrogen source in PtX applications. Its reduced environmental burden, thermal integration, and simplified scale-up potential make GSR-H2 a viable contributor to net-zero PtX systems, particularly where renewable energy is abundant and electricity-intensive hydrogen production faces economic or infrastructure constraints.

03 NATURAL GAS↗

Coupled Investigation of Fracture Permeability Impact on Reservoir Stress and Seismic Slip Behavior (Final Technical Report)

Enhanced Geothermal Systems (EGS) produce clean energy by circulating fluid through hot rock deep underground and bringing that heat to the surface to generate electricity. For this process to work reliably, fluids must be able to move efficiently through networks of natural or engineered fractures in the rock. Enhancing and maintaining subsurface permeability over time is essential for sustainable energy production. However, fluid injection changes the underground temperature, pressure, rock stress, and chemistry, which can alter permeability and sometimes trigger earthquakes. Predicting these interconnected processes remains a key challenge. To address this, we combined high-temperature laboratory experiments with high-fidelity simulations to better understand how fractures in geothermal reservoirs evolve over time. Our experiments measured how fractures respond to stress, slip, slip rate, and chemical reactions under geothermal conditions. These data were integrated into coupled thermal-hydrological-mechanical-chemical and earthquake (THMC+E) models tailored to the Utah FORGE site. The validated modeling framework improves predictions of reservoir performance and seismic response and helps guide operational decisions. This work reduces technical risk and strengthens the scientific foundation needed to make geothermal energy a reliable and scalable clean energy resource.

15 GEOTHERMAL ENERGY↗

Condition-Based Maintenance of a Circulating Water System of a Canadian Nuclear Power Plant using Machine Learning and Statistical Tools

Canada Deuterium Uranium pressurized-heavy-water reactors (PHWR) are a type of nuclear power plant that generate clean and reliable energy. The scope of this work is to automate data analysis methodologies to inform a condition-based maintenance strategy of a circulating water system (CWS) of a PHWR. The multiunit CWS provides a continuous supply of water to cool steam condensers, even during transient scenarios, thereby improving the thermal efficiency. This work aims to develop a machine learning (ML) based approach to detect anomalies in heterogeneous data of a CWS in a PHWR to help inform a predictive maintenance strategy. The heterogeneous data include textual and numeric time series data for a PHWR. Natural-language-processing (NLP)-based models are used to analyze textual data contained in work orders and operator logs and an event-timeseries correlation detection method is applied to assist anomalies diagnoses for CWS. An ML model Robust Linear Model (RLM) is also used to remove the seasonal variations in the system variable distributions based on distributions of environmental variables. A machine learning model, Density-Based Spatial Clustering of Applications with Noise (DBSCAN), trained on both original data and data without any seasonal variations will then be used to detect if an anomaly exists. Thus, by moving to an automated methodology to detect, classify, and forecast anomalies, the maintenance strategy would be based on component condition instead of a time-based schedule.

97 - MATHEMATICS AND COMPUTING↗

Establishing reference ranges for circulating biomarkers of drug‐induced liver injury in healthy human volunteers 1

Aims The potential of mechanistic biomarkers to improve prediction of drug‐induced liver injury (DILI) and hepatic regeneration is widely acknowledged. We sought to determine reference intervals for new biomarkers of DILI and regeneration, as well as to characterize their natural variability and impact of diurnal variation. Methods Serum samples from 227 healthy volunteers were recruited as part of a cross‐sectional study; of these, 25 subjects had weekly serial sampling over 3 weeks, while 23 had intensive blood sampling over a 24h period. Alanine aminotransferase (ALT), MicroRNA‐122 (miR‐122), High Mobility Group Box‐1 (HMGB1), total Keratin‐18 (K18), caspase‐cleaved Keratin‐18 (ccK18), Glutamate Dehydrogenase (GLDH) and Macrophage Colony‐Stimulating Factor‐1 (CSF‐1) were assayed. Results Reference intervals were established for each biomarker based on the 97.5% quantile (90% CI) following the assessment of fixed effects in univariate and multivariable models. Intra‐individual variability was found to be non‐significant, and there was no significant impact of diurnal variation. Conclusion Reference intervals for novel DILI biomarkers have been described. An upper limit of a reference range might represent the most appropriate mechanism to utilize these data. These data can now be used to interpret data from exploratory clinical DILI studies and to assist their further qualification as required by regulatory authorities.

Jorgensen, Andrea L. [Department of Health Data Sc↗

Design Approach for Circulating Fluidized Bed Riser Reactors such as NETL ASURE: A Review for Clustering Flow

Circulating fluidized bed riser reactors have been a commercial reality for some 80 to 90 years. Through all this time and hundreds if not thousands of research papers on the topic, no clear understanding exists on what is required to design and build a process reactor. There are numerous reasons for this, but the most significant reason is likely that riser reactors are chaotic in nature and unless this chaotic behavior is accounted for, there will be wide discrepancies in the predicted performance and in attempts to scale these reactors without significant trial and error. This work puts forth a new methodology to design riser reactors based upon the desired operating range using the chaotic microstructure behavior. This is accomplished through the use of a nondimensional regime map that was developed using chaotic parameters of memory and order/disorder along with higher moments of skewness and kurtosis. Validation of the approach is provided with circulating fluidized bed combustors and applied to the design of the NETL ASURE facility.

42 ENGINEERING↗

Life cycle assessment of a novel gas switching reforming for sustainable hydrogen production with CO2 capture

Gas switching reforming for hydrogen production (GSR-H2) presents an efficient, low-carbon hydrogen production method that incorporates integrated carbon capture, offering efficiency gains over traditional methods such as proton exchange membrane (PEM) electrolysis, steam methane reforming (SMR) and the newer method of chemical looping reforming (CLR). GSR-H2 has been demonstrated in lab scale which operates as an exothermic process that eliminates the need for additional natural gas combustion, using its own waste heat to generate process steam and partially offset energy usage through electricity production. Beyond its thermal self-sufficiency, GSR-H2 advances upon CLR by integrating all reaction stages within a single reactor cluster, eliminating the complexities of solid circulation, reducing capital costs, and enhancing overall process efficiency. This streamlined design simplifies scale-up and enables inherent CO2 separation with minimal energy penalty, making GSR-H2 a highly competitive pathway for low-carbon hydrogen production. This study presents the first life cycle assessment (LCA) of GSR-H2, offering a novel evaluation of this new process’s environmental impacts across diverse energy scenarios. Key findings reveal that in the renewables-powered scenario, GSR-H2 achieves a GWP of 2.77 kg CO2 eq per kg H2, a substantial improvement over SMR’s 10.4 kg CO2 eq and close to the low emissions of CLR (1.84 kg CO2 eq) and PEM electrolysis (1.85 kg CO2 eq). These results demonstrate GSR-H2’s competitive advantage as a lower-emission alternative, combining design simplicity and efficiency gains, especially in renewable-integrated systems. These results establish GSR-H2 as a competitive, scalable option for hydrogen production, particularly in decarbonization efforts.

03 NATURAL GAS↗

Changing effects of external forcing on Atlantic–Pacific interactions

Recent studies have highlighted the increasingly dominant role of external forcing in driving Atlantic and Pacific Ocean variability during the second half of the 20th century. This paper provides insights into the underlying mechanisms driving interactions between modes of variability over the two basins. We define a set of possible drivers of these interactions and apply causal discovery to reanalysis data, two ensembles of pacemaker simulations where sea surface temperatures in either the tropical Pacific or the North Atlantic are nudged to observations, and a pre-industrial control run. We also utilize large-ensemble means of historical simulations from the Coupled Model Intercomparison Project Phase 6 (CMIP6) to quantify the effect of external forcing and improve the understanding of its impact. A causal analysis of the historical time series between 1950 and 2014 identifies a regime switch in the interactions between major modes of Atlantic and Pacific climate variability in both reanalysis and pacemaker simulations. A sliding window causal analysis reveals a decaying El Niño–Southern Oscillation (ENSO) effect on the Atlantic as the North Atlantic fluctuates towards an anomalously warm state. The causal networks also demonstrate that external forcing contributed to strengthening the Atlantic's negative-sign effect on ENSO since the mid-1980s, where warming tropical Atlantic sea surface temperatures induce a La Niña-like cooling in the equatorial Pacific during the following season through an intensification of the Pacific Walker circulation. The strengthening of this effect is not detected when the historical external forcing signal is removed in the Pacific pacemaker ensemble. The analysis of the pre-industrial control run supports the notion that the Atlantic and Pacific modes of natural climate variability exert contrasting impacts on each other even in the absence of anthropogenic forcing. The interactions are shown to be modulated by the (multi)decadal states of temperature anomalies of both basins with stronger connections when these states are “out of phase”. We show that causal discovery can detect previously documented connections and provides important potential for a deeper understanding of the mechanisms driving changes in regional and global climate variability.