Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NSLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SIMULATIONS OF TRANSVERSE STACKING IN THE NSLS-II BOOSTER

The NSLS-II injection system consists of a 200 MeV linac and a 3 GeV booster. The linac needs to deliver 15 nC in 80 - 150 bunches to the booster every minute to achieve current stability goals in the storage ring. This is a very stringent requirement that has not been demonstrated at an operating light source. We have developed a scheme to transversely stack two bunch trains in the NSLS-II booster in order to alleviate the charge requirements on the linac. This scheme has been outlined previously. In this paper we show particle tracking simulations of the tracking scheme. We show simulations of the booster ramp with a stacked beam for a variety of lattice errors and injected beam parameters. In all cases the performance of the proposed stacking method is sufficient to reduce the required charge from the linac. For this reason the injection system of the NSLS-II booster is being designed to include this feature. The NSLS-II injection system consists of a 200 MeV linac and a 3 GeV booster. The injectors must provide 7.5nC in bunch trains 80-150 bunches long every minute for top off operation of the storage ring. Top off then requires that the linac deliver 15nC of charge once losses in the injector chain are taken into consideration. This is a very stringent requirement that has not been demonstrated at an operating light source. For this reason we have developed a method to transversely stack two bunch trains in the booster while maintaining the charge transport efficiency. This stacking scheme has been discussed previously. In this paper we show the simulations of the booster ramp with a single bunch train in the booster. Then we give a brief overview of the stacking scheme. Following, we show the results of stacking two bunch trains in the booster with varying beam emittances and train separations. The behavior of the beam through the ramp is examined showing that it is possible to stack two bunch trains in the booster.

43 PARTICLE ACCELERATORS↗

NSLS-II RF BEAM POSITION MONITOR

An internal R&D program has been undertaken at BNL to develop a sub-micron RF Beam Position Monitor (BPM) for the NSLS-II 3rd generation light source that is currently under construction. The BPM R&D program started in August 2009. Successful beam tests were conducted 15 months from the start of the program. The NSLS-II RF BPM has been designed to meet all requirements for the NSLS-II Injection system and Storage Ring. Housing of the RF BPM's in +-0.1 C thermally controlled racks provide sub-micron stabilization without active correction. An active pilot-tone has been incorporated to aid long-term (8hr min) stabilization to 200nm RMS. The development of a sub-micron BPM for the NSLS-II has successfully demonstrated performance and stability. Pilot Tone calibration combiner and RF synthesizer has been implemented and algorithm development is underway. The program is currently on schedule to start production development of 60 Injection BPM's starting in the Fall of 2011. The production of {approx}250 Storage Ring BPM's will overlap the Injection schedule.

43 PARTICLE ACCELERATORS↗

Rogue Mode Shileding in NSLS-II Multipole Vacuum Chambers

Modes with transverse electric field (TE-modes) in the NSLS-II multipole vacuum chamber can be generated at frequencies above 450MHz due to its geometric dimensions. Since the NSLS-II BPM system monitors signals within 10 MHz band at RF frequency of 500 MHz, frequencies of higher-order modes (HOM) can be generated within the transmission band of the band pass filter. In order to avoid systematic errors in the NSLS-II BPM system, we introduced frequency shift of HOMs by using RF metal shielding located in the antechamber slot. We demonstrated numerical modeling and experimental studies of the spurious TE modes in the NSLS-II vacuum chambers with antechamber slot. Calculated frequencies of TE-modes in considered chambers with and without RF shielding were verified experimentally. Flexible BeCu RF shielding inside each chamber at proper location shifts frequencies of H{sub 10p}-modes above {approx}900MHz, except chambers S6 odd and even. These chambers need special attention because of synchrotron radiation from downstream magnets. S6 odd multipole vacuum chamber needs to be measured and the RF shielding length has to be optimized. RF shielding looks adequate for baseline design. Fifty percent of open space provides adequate pumping speed.

25mm434mhz↗

Design of coupler for the NSLS-II storage ring superconducting RF cavity

NSLS-II is a 3GeV, 500mA, high brightness, 1 MW beam power synchrotron facility that is designed with four superconducting cavities working at 499.68 MHz. To operate the cavities in over-damped coupling condition, an External Quality Factor (Qext) of {approx}65000 is required. We have modified the existing coupler for the CESR-B cavity which has a Qext of {approx}200,000 to meet the requirements of NSLS-II. CESR-B cavity has an aperture coupler with a coupler 'tongue' connecting the cavity to the waveguide. We have optimized the length, width and thickness of the 'tongue' as well as the width of the aperture to increase the coupling using the three dimensional electromagnetic field solver, HFSS. Several possible designs will be presented. We have modified the coupler of the CESR-B cavity to be used in the storage ring at the NSLS-II project using HFSS and verified using CST Microwave Studio. Using a combination of increasing the length and width of the coupler tongue and increasing the width of the aperture, the external Q of the cavity coupler was decreased to {approx}65000 as required for the design of the NSLS-II storage ring design.

3GeV↗

Analysis of the optical design of the NSLS-II Coherent Hard X-ray beamline

Ultra-low emittance third-generation synchrotron radiation sources such as the NSLS-II offer excellent opportunities for the development of experimental techniques exploiting x-ray coherence. Coherent light scattered by a heterogeneous sample produces a speckle pattern characteristic for the specific arrangement of the scatterers. This may vary over time, and the resultant intensity fluctuations can be measured and analyzed to provide information about the sample dynamics. X-ray photon correlation spectroscopy (XPCS) extends the capability of dynamic light scattering to opaque and turbid samples and extends the measurements of time evolution to nanometer length scales. As a consequence XPCS became crucial in the study of dynamics in systems including, but not being limited to, colloids, polymers, complex fluids, surfaces and interfaces, phase ordering alloys, etc. In this paper we present the conceptual optical design and the theoretical performance of the Coherent Hard X-ray (CHX) beamline at NSLS-II, dedicated to XPCS and other coherent scattering techniques. For the optical design of this beamline, there is a tradeoff between the coherence needed to distinguish individual speckles and the phase acceptance (high intensity) required to measure fast dynamics with an adequate signal-to-noise level. As XPCS is a 'photon hungry' technique, the beamline optimization requires maximizing the signal-to-noise ratio of the measured intensity-intensity autocorrelation function. The degree of coherence, as measured by a two-slit (Young) experiment, is used to characterize the speckle pattern visibilities. The beamline optimization strategy consists of maximization of the on-sample intensity while keeping the degree of coherence within the 0.1-0.5 range. The resulted design deviates substantially from an ad-hoc modification of a hard x-ray beamline for XPCS measurements. The CHX beamline will permit studies of complex systems and measurements of bulk dynamics down to the microsecond time scales. In general, the 10-fold increase in brightness of the NSLS-II, compared to other sources, will allow for measurements of dynamics on time-scales that are two orders of magnitude faster than what is currently possible. We also conclude that the common approximations used in evaluating the transverse coherence length would not be sufficiently accurate for the calculation of the coherent properties of an undulator-based beamline, and a thorough beamline optimization at a low-emittance source such as the NSLS-II requires a realistic wave-front propagation analysis.

36 MATERIALS SCIENCE↗

NSLS-II commissioning and operation

The National Synchrotron Light Source II at Brookhaven National Lab is a third-generation synchrotron radiation facility that has been commissioned in 2014. The facility is based on a 3 GeV electron storage ring, which will circulate 500 mA of beam current at 1 nm rad horizontal emittance. The storage ring is 792 meters in circumference and will accommodate more than 60 beamlines in the final built-out. The beamline sources range from insertion-devices located in straight sections, bending magnets or three-pole-wigglers configured in multiple branches. The NSLS-II storage ring commissioning was successfully completed in July 2014 and the facility delivered the first user light on October 23, 2014. Currently the storage ring reached 300 mA beam current and achieved 1 nm rad of horizontal emittance with 3 sets of Damping Wigglers. At this point six NSLS-II project beamlines are routinely taking photons with beam current at 150 mA. This paper reviews the NSLS-II accelerator design and commissioning experience.

43 PARTICLE ACCELERATORS↗

Design and Measurement of the NSLS II Correctors

The National Synchrotron Light Source II (NSLS-II) under construction at Brookhaven National Laboratory will be a new state-of-the-art 3 Gev electron storage ring designed to deliver world-leading intensity and brightness, and will produce x-rays more than 10,000 times brighter than the current NSLS at Brookhaven. The 792-meter circumference storage ring is comprised of approximately 1000 magnetic elements, 300 of which are discrete corrector magnets. The three variants are: 120 of the 100 mm aperture correctors, 60 of the 156 mm aperture correctors, and 90 of the air core correctors.[1] The 100 mm and 156 mm horizontal and vertical dipole correctors come in two varieties: with and without a DC skew quad corrector. The air core is strictly an AC horizontal and vertical dipole corrector. The specifications are listed. Discrete corrector magnets are used for the 230 horizontal and vertical steering magnets in the NSLS-II storage ring. A unique design incorporates both dipole and skew quad correctors for (DC) steering in the same magnet. Separate AC (orbit feedback) correctors have also been designed. Comparison with alternate designs are presented as well as prototype measurements.

43 PARTICLE ACCELERATORS↗

Getting More From Less: Correlated Single-Crystal Spectroscopy and X-ray Crystallography at the NSLS (456th Brookhaven Lecture)

By integrating different techniques to collect complementary data at beam line X26C of the National Synchrotron Light Source (NSLS), Allen Orville and his colleagues of the Macromolecular Crystallography Research Resource are providing new insights into the structures of macromolecules. During the 456th Brookhaven Lecture, on Wednesday, April 21st, Orville will describe his approach and his findings. During his talk, Orville will discuss his field of protein crystallography, reviewing its landmark discoveries and explaining new ways of using the NSLS and, in the future, the NSLS-II, to build on those discoveries. Allen Orville took his Ph.D. in biology from the University of Minnesota in 1997. After completing a postdoc with the Howard Hughes Medical Institute at the University of Oregon, 1997-2000, he began an assistant professor at the Georgia Institute of Technology. Orville joined BNL's Biology Department in 2006 as an associate biophysicist and was promoted to biophysicist in 2008.

43 PARTICLE ACCELERATORS↗

PERFORMANCE OF THE DIAGNOSTICS FOR NSLS-II LINAC COMMISSIONING

The National Synchrotron Light Source II (NSLS-II) is a state of the art 3-GeV third generation light source currently under construction at Brookhaven National Laboratory. The NSLS-II injection system consists of a 200 MeV linac, a 3-GeV booster synchrotron and associated transfer lines. The transfer lines not only provide a means to deliver the beam from one machine to another, they also provide a suite of diagnostics and utilities to measure the properties of the beam to be delivered. In this paper we discuss the suite of diagnostics that will be used to commission the NSLS-II linac and measure the beam properties. The linac to booster transfer line can measure the linac emittance with a three screens measurement or a quadrupole scan. Energy and energy spread are measured in a dispersive section. Total charge and charge uniformity are measured with wall current monitors in the linac and transformers in the transfer line. We show that the performance of the diagnostics in the transfer line will be sufficient to ensure the linac meets its specifications and provides a means of trouble shooting and studying the linac in future operation.

200 MeV linac↗

NSLS-II Transport Line Progress

The National Synchrotron Light Source II (NSLS-II) is a state-of-the-art 3-GeV third generation light source currently under construction at Brookhaven National Laboratory. The NSLS-II injection system consists of a 200 MeV linac, a 3-GeV booster synchrotron and associated transfer lines. The first part of the Linac to Booster Transport (LBT) line has been installed for linac commissioning. This part includes all components necessary to commission the NSLS-II linac. The second part of this transport line is undergoing installation. Initial results of hardware commissioning will be discussed. The Booster to Storage Ring (BSR) transport line underwent a design review. The first part of the BSR transport line, consisting of all components necessary to commission the booster will be installed in 2012 for booster commissioning. We report on the final design of the BSR line along with the plan to commission the booster.

3-GeV↗

Thermally induced cracking on the massive concrete structure of the NSLS II synchrotron and its engineering remediation

Synchrotron accelerator facilities such as the NSLS II require extreme stability, both transient (short-term) and quasi-static (long-term) to achieve the desired resolution performance. Consequently, even μm-level movements, particularly differential movements between locations in the concrete structure supporting the accelerator electron beam lattice (storage ring) or high sensitivity experiments (experimental floor) will lead to serious degradation of its performance. Differential settlement in the overall structure or structural movement exceeding anticipated levels will inevitably degrade the performance and will require intervention. Presented in this paper are the design philosophy of the NSLS II ring structure favoring a monolithic ring, the observed cracking behavior of the young NSLS II concrete following casting and in combination with extreme ambient temperature fluctuation, the results of a non-linear, high-fidelity numerical analysis used to emulate the observed cracking and establish the driving mechanism, the numerical analysis-based identification of the crack-arresting solution and finally the implementation of the remediation solution and the long-term performance of the adopted engineering solution. The multi-stage process revealed that computational methods such as non-linear finite element methods have the potential of providing engineering guidance even when complex structures and in combination with non-linear materials, such as steel reinforcement and concrete are involved.

42 ENGINEERING↗

Optical metrology at the NSLS-II

Rapid progress in synchrotron optics performance places a high demand on optical characterization techniques used to validate surface parameters prior to installation of the X-ray optics. It is now necessary to characterize optical surface figure and slope errors and roughness on meter-long optics over spatial frequencies as short as 0.1 {micro}m The new NSLS-II Optical Metrology Laboratory (OML) includes instruments for measuring: (1) long spatial frequency figure errors with a ZYGO MST Fizeau-type 4* interferometer, capable of 0.1 nm sensitivity, (2) mid spatial frequencies with an upgraded ZYGO NewView 6300 white light interferometric microscope, capable of reaching 0.1 nm accuracy at a lateral resolution of 1 {micro}m, (3) high frequency roughness with an AFM (Nanosurf AG) with linearity better than 0.2% over the 80 {micro}m measurement area and sensitivity approaching 0.01 nm, and (4) slope errors with a long trace profiler currently under development that will be able to reach 50 nrad slope error accuracy. At present, the OML supports the NSLS-II R&D efforts and provides ongoing testing for NSLS optics. Future plans include the construction of a specialized metrology beamline for at-wavelength metrology, radiometry, in situ surface figuring, crystal optics characterization, and instrumentation development.

43 PARTICLE ACCELERATORS↗

Experimental evidence of ion-induced instabilities in the NSLS-II storage ring

Fast ion instability has been identified as one of the most prominent instabilities in the recently constructed NSLS-II storage ring at Brookhaven National Laboratory. At a relatively low beam current (~ 25 mA) multi-bunch fills, ion-induced instabilities have already been observed during the early stages of machine commissioning. At present user operation with 250 mA in ~1000 bunches, the fast ion still remains the dominant instability, even after months of vacuum conditioning at high current. Ion-induced dipole motions of the electron beam have been suppressed using the transverse bunch-by-bunch (BxB) feedback system. However other adverse effects of this instability, such as the vertical beam size increase along the bunch train cannot be cured by the feedback system. Therefore, to achieve the NSLS-II design current of 500 mA while maintaining a small vertical beam emittance, it is important to further understand the fast ion instability and develop mitigation techniques. This paper reports on a series of ion-instability observations at various fill patterns and beam currents using start-of-art NSLS-II diagnostic tools.

43 PARTICLE ACCELERATORS↗

First demonstration of the fast-to-slow corrector current shift in the NSLS-II storage ring

In order to realize the full benefits of the high brightness and ultra-small beam sizes of NSLS-II, it is essential that the photon beams are exceedingly stable. In the circumstances of implementing local bumps, changing ID gaps, and long term drifting, the fast orbit feedback (FOFB) requires shifting the fast corrector strengths to the slow correctors to prevent the fast corrector saturation and to make the beam orbit stable in the sub-micron level. As the result, a reliable and precise technique of fast-to-slow corrector strength shift has been developed and tested at NSLS-II. This technique is based on the fast corrector response to the slow corrector change when the FOFB is on. In this article, the shift technique is described and the result of proof-of-principle experiment carried out at NSLS-II is presented. The maximum fast corrector current was reduced from greater than 0.45 A to less than 0.04 A with the orbit perturbation within ±1 μm.

43 PARTICLE ACCELERATORS↗

Three-pole wigglers at NSLS-II

The National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Lab (BNL) is a third-generation medium-energy storage ring with 3 GeV and sub-nm-rad horizontal emittance, equipped with a top-off capability of 500 mA. It is designed to deliver an extremely intense photon beam across a wide spectral range, from the far-infrared to the very hard X-ray region. This outstanding performance is achieved through a combination of bending magnets (BM), three-pole wigglers (3 PW), and advanced insertion device (ID) sources. Six three-pole wigglers have been constructed at the NSLS-II IDs Lab. These devices are used to produce broadband radiation with lower angular power density and to monitor the electron beam emittance and energy spread. Here, this paper describes the R&D activities focused on developing the required magnetic and mechanical designs, along with magnetic field optimization and the final magnetic measurement results. It also covers the spectral brightness, flux, power density, spatial and angular output properties of the 3 PWs, including their commissioning results and their effects on the performance of the NSLS-II storage ring.

36 MATERIALS SCIENCE↗

New In-Situ and Operando Facilities for Catalysis Science at NSLS-II: The Deployment of Real-Time, Chemical, and Structure-Sensitive X-ray Probes

The start of operations at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory heralded a new beginning for photon-science-based research capabilities in catalysis. This new facility builds on many years of pioneering work that was conducted at the NSLS synergistically by many scientists from academia, government labs, and industry. Over several decades, numerous discoveries in catalysis were driven through the emergence of an arsenal of tools at the NSLS that exploited the power of emerging X-ray methods encompassing scattering, spectroscopy, and imaging. Thus, in-situ and operando methodologies that coupled reactor environments directly with advanced analytical techniques paved a rapid path towards realizing an improved fundamental understanding at the frontiers of chemical science challenges of the day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron Catalysis Consortium (SCC) at NSLS-II: Dedicated Beamline Facilities for In Situ and Operando Characterization of Catalysts

The Synchrotron Catalysis Consortium (SCC) was funded and established in September 2005 at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL). For more than a decade, the SCC was the first of its kind in the United States, with a mission to promote the utilization of synchrotron techniques for cutting-edge catalysis research under in-situ conditions. The consortium consists of three Principal Investigators (Jingguang Chen, Columbia University, Anatoly Frenkel, Stony Brook University/BNL, and Jose Rodriguez, BNL) and scientific staff member Nebojsa Marinkovic. The initial team also included Radoslav Adzic, BNL, and collaborators from academic, national, and industrial laboratories. During the first decade of its operations at three NSLS beamlines (X18A, X18B, and X19A) until the closing of NSLS on September 30, 2014, the primary goal of the SCC team was to provide assistance and to develop new sciences/techniques to the catalysis community...This report outlines a brief history, specifications, techniques, and training and outreach for the facility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Next generation experimental data access at NSLS-II

The NSLS-II network and computing infrastructure has been significantly updated recently. The re-IP process in 2020-2021 enabled the NSLS-II network to be routable to the rest of the BNL campus. Then, standardization of the operating systems and deployment procedures helped to deliver a consistent environment to workstations and servers used by all NSLS-II beamlines. In particular, the RedHat Enterprise Linux 8 was deployed to 700+ machines using the RedHat Satellite infrastructure management product, and all critical services (IOCs, databases, etc.) were migrated to the new OS. NFS users’ home directories are consistent across all of the machines, which eliminates the need for the individual configuration of the user environment on each host. The standard suite of software packages is available to the beamline staff and users, which includes the system packages (deployed via RPM) as well as the conda environments for data acquisition and analysis. Security measures were implemented to comply with the industry standards, which include multi-factor authentication (using Duo), secure screen lock for the beamline machines, and advanced access control to the experimental data that is stored in shared central storage available on all hosts. These major enhancements facilitated sharing the experimental data (currently for a number of selected beamlines, with a plan to extend it to the whole facility in the nearest future) with the users via an externally facing JupyterHub instance. The beamlines keep using the Bluesky data acquisition framework to orchestrate their experiments, and the new infrastructure enabled them to use a next-generation data access library called tiled.

36 MATERIALS SCIENCE↗