Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development and application of a low-noise, high-speed optical detector module for carbon density fluctuation measurements on Wendelstein 7-X

A low-noise, high-speed optical detector module is characterized and successfully commissioned for the measurement of high-frequency, low-intensity beam emission on Wendelstein 7-X (W7-X). An ultra-narrow bandpass optical filter is employed to selectively transmit the desired emission line while suppressing broadband plasma background emissions. Carbon density fluctuations are investigated by observing the carbon C-VI emission line (n = 8 → 7, λ ∼ 529 nm), arising from charge exchange (CX) between the neutral beam atoms and the intrinsic carbon population. Here, we present the characterization of the optical detector module and experimental measurements of carbon density fluctuations using available fibers on W7-X. The initial performance of the detector is presented in both active and passive CX measurements of intrinsic carbon density fluctuations. The low frequency dynamics of fluctuation is observed in response to the neutral beam and the pellet injection, demonstrating that the optical detector module is capable of providing a sufficient signal level with an adequate signal-to-noise ratio. In the upcoming OP2.4 campaign, this optical detector module will be adapted for use in a beam emission spectroscopy system by replacing the optical bandpass filter with one centered at 654 nm (90% transmission: 653–655.3 nm), which facilitates two-dimensional measurements of ion gyro-scale turbulence on W7-X.

Charge exchange recombination spectroscopy↗

Neural Posterior Estimation for Scalable and Accurate Inverse Parameter Inference in Li-Ion Batteries

Diagnosing the internal state of Li-ion batteries is critical for battery research, operation of real-world systems, and prognostic evaluation of remaining lifetime. By using physics-based models to perform probabilistic parameter estimation via Bayesian calibration, diagnostics can account for the uncertainty due to model fitness, data noise, and the observability of any given parameter. However, Bayesian calibration in Li-ion batteries using electrochemical data is computationally intensive even when using a fast surrogate in place of physics-based models, requiring many thousands of model evaluations. A fully amortized alternative is neural posterior estimation (NPE). NPE shifts the computational burden from the parameter estimation step to data generation and model training, reducing the parameter estimation time from minutes to milliseconds, enabling real-time applications. The present work shows that NPE can infer parameters equally or more accurately than Bayesian calibration, even if it leads to higher voltage reconstruction errors. We also demonstrate that the higher computational costs for data generation are tractable even in high-dimensional cases (ranging from 6 to 27 estimated parameters). The NPE method also offers several interpretability advantages over Bayesian calibration, such as local parameter sensitivity to specific regions of the voltage curve. The NPE method is demonstrated using an experimental fast charge dataset, with parameter estimates validated against measurements of loss of lithium inventory and loss of active material. The implementation is made available in a companion repository (https://github.com/NatLabRockies/BatFIT).

25 ENERGY STORAGE↗

Cherenkov photon background for low-noise silicon detectors in space

Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision phase control of an optical lattice with up to 50 dB noise suppression

An optical lattice is a periodic light crystal constructed from the standing-wave interference patterns of laser beams. It can be used to store and manipulate quantum degenerate atoms and is an ideal platform for the quantum simulation of many-body physics. A principal feature is that optical lattices are flexible and possess a variety of multidimensional geometries with modifiable band structure. An even richer landscape emerges when control functions can be applied to the lattice by modulation of the position or amplitude with Floquet driving. However, the desire of realizing high-modulation bandwidths while preserving extreme lattice stability has been difficult to achieve. In this paper, we demonstrate an effective solution that consists of overlapping two counterpropagating lattice beams and controlling the phase and intensity of each with independent acousto-optic modulators. Our phase controller mixes sampled light from both lattice beams with a common optical reference. This dual heterodyne locking method allows exquisite determination of the lattice position, while also removing parasitic phase noise accrued as the beams travel along separate paths. Here, we report up to 50 dB suppression in lattice phase noise in the 0.1–1 Hz band, along with significant suppression spanning more than 4 decades of frequency. The absolute phase diffusion of the lattice position is only 10 Å when integrated over 10 s. This method permits precise, high-bandwidth modulation (greater than 50 kHz) of the optical lattice intensity and phase. We demonstrate the efficacy of this approach by executing intricate time-varying phase profiles for atom interferometry.

Atom interferometry↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, Laney [UC, Berkeley (main)] (ORCID:000900078↗

Improving Building Footprint Extraction Using NAIP and 3DEP Lidar Derived Features with Deep Learning

Accurate building footprint extraction is critical for applications ranging from population estimation to disaster management. Although optical imagery provides detailed spectral information, it often struggles with shadows, occlusions, and background clutter in dense urban environments. Lidar data, by contrast, offer precise elevation and structural attributes but face challenges such as variable point density and noise. This study integrates multispectral imagery from the U.S. Department of Agriculture (USDA) National Agriculture Imagery Program (NAIP) with lidar-derived feature height and intensity from the U.S. Geological Survey (USGS) 3D Elevation Program (3DEP) to improve footprint extraction using a U-Net–based deep learning model. A six-band input stack (RGB, near-infrared, height, intensity) was developed, normalized, and tiled for training and evaluation against Microsoft Global Building Footprints (GBF). Results from the Houston, TX test site show that the six-band model achieved a precision of 0.86, recall of 0.88, F1 score of 0.87, and Intersection-over-Union (IoU) of 0.76, consistently outperforming four-band baselines by reducing false positives while maintaining sensitivity. Predictions on withheld Houston tiles confirmed strong within-region generalization, yielded a precision of 0.78, recall of 0.81, F1 score of 0.79, and IoU of 0.66. Qualitative analysis further revealed limitations stemming from both training label quality and vegetation–building confusion. These findings demonstrate the complementary value of integrating spectral and structural information for robust building footprint extraction and how domain adaptation strategies can be used to enhance cross-regional transferability.

Liu, Jung Kuan [United States Geological Survey (U↗

Atmospheric Modeling and Denoising for Millimeter-Wave Line Intensity Mapping

Line-intensity mapping (LIM) offers a promising approach to mapping large-scale cosmic structure, and the greatest obstacle for ground-based observations at millimeter wavelengths is foreground contamination from atmospheric emission. In this work, we present a simulation and denoising framework designed to isolate and subtract atmospheric fluctuations from LIM data, modeled after the instrument parameters of the South Pole Telescope Summertime Line Intensity Mapper (SPT-SLIM). We generate mock observations spanning 125-175 GHz containing cosmic signals, precipitable water vapor screens, ice crystal fluctuations, and photon noise. We then implement a spatial-spectral atmospheric removal pipeline combining per-pixel linear template regression with a two-dimensional Fourier-domain filter. The framework is evaluated under simulated conditions in the South Pole and the Atacama Desert across three key metrics: cosmic signal preservation, foreground subtraction efficiency, and instrument noise injection. Our pipeline achieves atmospheric suppression at large spatial scales, and these results establish a physically grounded foundation for atmosphere removal in ground-based LIM data collection.

Saye, L. K. [UC, Berkeley (main)] (ORCID:000900078↗

Patch2Self2: Self-supervised Denoising on Coresets via Matrix Sketching

Diffusion MRI (dMRI) non-invasively maps brain white matter yet necessitates denoising due to low signal-to-noise ratios. Patch2Self (P2S) employing self-supervised techniques and regression on a Casorati matrix effectively denoises dMRI images and has become the new de-facto standard in this field. P2S however is resource intensive both in terms of running time and memory usage as it uses all voxels (n) from all-but-one held-in volumes (d-1) to learn a linear mapping Phi : \mathbb R ^ n x(d-1) \mapsto \mathbb R ^ n for denoising the held-out volume. The increasing size and dimensionality of higher resolution dMRI acquisitions can make P2S infeasible for large-scale analyses. This work exploits the redundancy imposed by P2S to alleviate its performance issues and inspect regions that influence the noise disproportionately. Specifically this study makes a three-fold contribution: (1) We present Patch2Self2 (P2S2) a method that uses matrix sketching to perform self-supervised denoising. By solving a sub-problem on a smaller sub-space so called coreset we show how P2S2 can yield a significant speedup in training time while using less memory. (2) We present a theoretical analysis of P2S2 focusing on determining the optimal sketch size through rank estimation a key step in achieving a balance between denoising accuracy and computational efficiency. (3) We show how the so-called statistical leverage scores can be used to interpret the denoising of dMRI data a process that was traditionally treated as a black-box. Experimental results on both simulated and real data affirm that P2S2 maintains denoising quality while significantly enhancing speed and memory efficiency achieved by training on a reduced data subset.

Fadnavis, Shreyas↗

Desmearing two-dimensional small-angle neutron scattering data by central moment expansions

Resolution smearing is a critical challenge in the quantitative analysis of two-dimensional small-angle neutron scattering (SANS) data, particularly in studies of soft-matter flow and deformation using SANS. Here, we present a central moment expansion technique to address smearing in anisotropic scattering spectra, offering a model-free desmearing methodology. By accounting for directional variations in resolution smearing and enhancing computational efficiency, this approach reconstructs desmeared intensity distributions from smeared experimental data. Computational benchmarks using interacting hard-sphere fluids and Gaussian chain models validate the accuracy of the method, while simulated noise analyses confirm its robustness under experimental conditions. Experimental validation using rheological SANS data from shear-induced micellar structures demonstrates the practicality and effectiveness of the proposed algorithm. The desmearing technique provides a powerful tool for advancing the quantitative analysis of anisotropic scattering patterns, enabling precise insights into the interplay between material microstructure and macroscopic flow behavior.

anisotropic scattering spectra↗

Mixed gain detector configurations for time-resolved X-ray solution scattering

X-ray detection at X-ray free-electron lasers is challenging in part due to the XFEL's extremely short and intense X-ray pulses. Experimental measurements are further complicated by the large fluctuations inherent to the self-amplified spontaneous emission process producing the X-rays. At the Linac Coherent Light Source the ePix10ka2M detector offers multiple gain modes, and auto-ranging between these, to increase the dynamic range while retaining low noise. For diffuse scattering techniques, such as time-resolved X-ray solution scattering, where the shape of the scattering pattern largely does not change between exposures, a fixed mix of different gain modes offers many of the same advantages as auto-ranging. We find that configuring individual ASICs in separate gain modes does not impact the intensity linearity of the gain response and has a limited effect on the effective dynamic range in regions with different gain mode settings while avoiding the complexities of auto-ranging. Small (<5%) non-linear gain contributions arise when pixels on the same ASIC are configured in different gain modes. We present a configuration scheme that is designed to select the optimal mixed gain configuration to minimize effects of saturation in the high-/medium-gain region, while maximizing the number of pixels with higher gain to improve the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low spontaneous Brillouin scattering in anti-resonant hollow-core fibers in GHz frequency range

Brillouin light scattering (BLS) is a powerful experimental tool that can be used to gain insights into the fundamental and applied properties of matter, like dispersions of quasiparticles in a solid, as well as their spatiotemporal dynamics. Many applications of light scattering favor the use of optical fibers in place of free-space optics. In this study, we compare the performance of anti-resonant hollow core fibers to that of conventional solid core fused silica fibers for BLS experiments in the GHz frequency range. Conventional fibers are barely suitable for low-noise measurements because of the spontaneous scattering of photons on various phononic modes present in the core and cladding. In the case of the hollow-core fiber, we identify a range of discrete phononic modes and associate them with the various acoustic modes of the structure surrounding the hollow core using finite-element numerical simulations. The measured relative intensity of the spontaneous BLS signal from these modes is orders of magnitude smaller than that of a solid-core fiber, making anti-resonant hollow-core fibers one of the best solutions for the single-mode light guidance for BLS and potentially other low-noise photonic experiments.

36 MATERIALS SCIENCE↗

Prediction of electric and magnetic fields from spectral data using machine learning algorithms for Doppler-free saturation spectroscopy diagnostics

The prediction of electric and magnetic field amplitudes from atomic spectral data is critical for plasma control in fusion devices such as tokamaks. Conventional approaches that rely on physics-based models are computationally expensive and unsuitable for real-time applications. In this work, we develop and benchmark three machine learning algorithms—simulation-based inference (SBI), fully connected neural networks (FCNN), and histogram-based gradient boosting regression (GBR-Hist)—to infer field intensities directly from Doppler-free saturation spectroscopy (DFSS) spectra. Synthetic datasets of spectra were generated using the EZSSS code and evaluated both with and without added Poisson noise to mimic experimental conditions. We find that SBI achieves the highest accuracy and robustness, FCNN provides a strong balance of accuracy and computational efficiency for real-time applications, and GBR-Hist offers the fastest inference but is more sensitive to noise. Furthermore, these results demonstrate the potential of machine learning to accelerate DFSS analysis and enhance its utility for plasma diagnostics and control.

Doppler-free saturation spectroscopy↗

Optimizing transmit field inhomogeneity of parallel RF transmit design in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) provides a higher signal-to-noise ratio and, thereby, higher spatial resolution. However, UHF MRI introduces challenges such as transmit radiofrequency (RF) field (B+1) inhomogeneities, leading to uneven flip angles and image intensity anomalies. These issues can significantly degrade imaging quality and its medical applications. This study addresses B+1 field homogeneity through a novel deep learning-based strategy. Traditional methods like Magnitude Least Squares (MLS) optimization have been effective but are time-consuming and dependent on the patient’s presence. Recent machine learning approaches, such as RF Shim Prediction by Iteratively Projected Ridge Regression and deep learning frameworks, have shown promise but face limitations like extensive training times and oversimplified architectures. We propose a two-step deep learning strategy. First, we obtain the desired reference RF shimming weights from multi-channel B+1 fields using random-initialized Adaptive Moment Estimation. Then, we employ Residual Networks (ResNets) to train a model that maps B+1 fields to target RF shimming outputs. Our approach does not rely on pre-calculated reference optimizations for the testing process and efficiently learns residual functions. Comparative studies with traditional MLS optimization demonstrate our method’s advantages in terms of speed and accuracy. The proposed strategy achieves a faster and more efficient RF shimming design, significantly improving imaging quality at UHF. This advancement holds potential for broader applications in medical imaging and diagnostics.

Lu, Zhengyi [Vanderbilt University]↗

A Trapping-Micro-LC-FAIMS/dCV-MS Strategy for Ultrasensitive and Robust Targeted Quantification of Protein Drugs and Biomarkers

The sensitivity of LC-MS in quantifying target proteins in plasma/tissues is significantly hindered by co-eluted matrix interferences. While antibody-based immuno-enrichment effectively reduces interferences, developing and optimizing antibodies are often time-consuming and costly. Here, in this study, by leveraging the orthogonal separation capability of Field Asymmetric Ion Mobility Spectrometry (FAIMS), we developed a FAIMS/differential-compensation-voltage (FAIMS/dCV) method for antibody-free, robust, and ultra-sensitive quantification of target proteins directly from plasma/tissue digests. By comparing the intensity-CV profiles of the target vs. co-eluted endogenous interferences, the FAIMS/dCV approach identifies the optimal CV for quantification of each target protein, thus maximizing the signal-to-noise ratio (S/N). Compared to quantification without FAIMS, this technique dramatically reduces endogenous interferences, showing a median improvement of the S/N by 14.8-fold for the quantification of 17 representative protein drugs and biomarkers in plasma or tissues and a 5.2-fold median increase in S/N over conventional FAIMS approach, which uses the peak CV of each target. We also discovered that the established CV parameters remain consistent over months and are matrix-independent, affirming the robustness of the developed FAIMS/dCV method and the transferability of the method across matrices. The developed method was successfully demonstrated in three applications: the quantification of monoclonal antibodies with sub-ng/mL LOQ in plasma, an investigation of the time courses of evolocumab and its target PCSK9 in a preclinical setting, and a clinical investigation of low abundance obesity-related biomarkers. This innovative and easy-to-use method has extensive potential in clinical and pharmaceutical research, particularly where sensitive and high-throughput quantification of protein drugs and biomarkers is required.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-shot femtosecond laser-induced breakdown spectroscopy in low-density gases

Single-shot fs laser-induced breakdown spectroscopy (LIBS) has been used to interrogate low-density gases of H 2 ⁠, CH 4 ⁠, CO 2 ⁠, and H 2 O ranging from 0.5 × 10 15 to 9.1 × 10 15 cm −3 (15–275 mTorr). Strong spectral signatures were observed above the noise baseline for each test gas at all densities considered. Unique molecular signatures were observed for both CH 4 and CO 2 along with atomic features for each gas. The LIBS intensity response with respect to density was determined for each species using Voigt lineshape fitting or numerical integration. Finally, the collection and analysis of LIBS spectra of composite mixtures of CH 4 –CO 2 and CH 4 –H 2 demonstrates that the extraction of individual densities from gas mixtures is feasible at low densities.

Artificial neural networks↗

Harnessing quantum light for microscopic biomechanical imaging of cells and tissues

The biomechanical properties of cells and tissues play an important role in our fundamental understanding of the structures and functions of biological systems at both the cellular and subcellular levels. Recently, Brillouin microscopy, which offers a label-free spectroscopic means of assessing viscoelastic properties in vivo, has emerged as a powerful way to interrogate those properties on a microscopic level in living tissues. However, susceptibility to photodamage and photobleaching, particularly when high-intensity laser beams are used to induce Brillouin scattering, poses a significant challenge. This article introduces a transformative approach designed to mitigate photodamage in biological and biomedical studies, enabling nondestructive, label-free assessments of mechanical properties in live biological samples. By leveraging quantum-light-enhanced stimulated Brillouin scattering (SBS) imaging contrast, the signal-to-noise ratio is significantly elevated, thereby increasing sample viability and extending interrogation times without compromising the integrity of living samples. The tangible impact of this methodology is evidenced by a notable three-fold increase in sample viability observed after subjecting the samples to three hours of continuous squeezed-light illumination, surpassing the traditional coherent light-based approaches. The quantum-enhanced SBS imaging holds promise across diverse fields, such as cancer biology and neuroscience where preserving sample vitality is of paramount significance. By mitigating concerns regarding photodamage and photobleaching associated with high-intensity lasers, this technological breakthrough expands our horizons for exploring the mechanical properties of live biological systems, paving the way for an era of research and clinical applications.

Li, Tian↗

X-ray diffraction characterization of magnetostriction in Terfenol-D

The magnetostrictive response of a Terfenol-D pellet was measured via a laboratory-based X-ray diffractometer. X-ray diffraction patterns were collected from the pellet sample with and without the presence of an applied magnetic field (~30 mT) generated by placing a large magnet under the pellet. A standard reference material, Silicon 640c, was employed as an internal standard. Magnetostriction values of 323 and 227 ppm Δl/l were determined for the (104) and (110) indexed peaks, respectively, assuming a rhombohedral structure for Terfenol-D. A threshold noise level value of ~20 to 30 ppm Δl/l was suggested based on before/after measurements in the absence of the applied field. No clear evidence of domain wall rotation was detected via changes in relative intensities of diffraction peaks in the presence of the applied magnetic field.

Magnetostriction↗

Fast-RF-Shimming: Accelerate RF shimming in 7T MRI using deep learning

Ultrahigh field (UHF) Magnetic Resonance Imaging (MRI) offers an elevated signal-to-noise ratio (SNR), enabling exceptionally high spatial resolution that benefits both clinical diagnostics and advanced research. However, the jump to higher fields introduces complications, particularly transmit radiofrequency (RF) field ($B^{+}_{1}$) inhomogeneities, manifesting as uneven flip angles and image intensity irregularities. These artifacts can degrade image quality and impede broader clinical adoption. Traditional RF shimming methods, such as Magnitude Least Squares (MLS) optimization, effectively mitigate $B^{+}_{1}$ inhomogeneity, but remain time-consuming. Recent machine learning approaches, including RF Shim Prediction by Iteratively Projected Ridge Regression and other deep learning architectures, suggest alternative pathways. Although these approaches show promise, challenges such as extensive training periods, limited network complexity, and practical data requirements persist. In this paper, we introduce a holistic learning-based framework called Fast-RF-Shimming, which achieves a 5000 ​× ​speed-up compared to the traditional MLS method. In the initial phase, we employ random-initialized Adaptive Moment Estimation (Adam) to derive the desired reference shimming weights from multi-channel $B^{+}_{1}$ fields. Next, we train a Residual Network (ResNet) to map $B^{+}_{1}$ fields directly to the ultimate RF shimming outputs, incorporating the confidence parameter into its loss function. Finally, we design Non-uniformity Field Detector (NFD), an optional post-processing step, to ensure the extreme non-uniform outcomes are identified. Comparative evaluations with standard MLS optimization underscore notable gains in both processing speed and predictive accuracy, which indicates that our technique shows a promising solution for addressing persistent inhomogeneity challenges.

Deep learning↗