Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

Ames-2021 CO 2 Dipole Moment Surface and IR Line Lists: Toward 0.1% Uncertainty for CO 2 IR Intensities

A highly accurate CO 2 ab initio dipole moment surface (DMS), Ames-2021, is reported along with 12 C 16 O 2 infrared (IR) intensity comparisons approaching a 1–4‰ level of agreement and uncertainty. The Ames-2021 DMS was accurately fitted from CCSD(T) finite-field dipoles computed with the aug-cc-pVXZ (X = T, Q, 5) basis for C atom and the d-aug-cc-pVXZ (X = T, Q, 5) basis for O atoms, and extrapolated to the one particle basis set limit. Fitting σ(rms) is 3.8 × 10^(–7) au for 4443 geometries below 15 000 per cm . The corresponding IR intensity, S Ames-2021 , are computed using the Ames-2 potential energy surface (PES), which is the best PES available for CO 2 . Compared to high accuracy IR studies for 2001i–00001 and 3001i–00001 bands, S Ames-2021 matches NIST experiment-based intensities [S NIST-HIT16 or S HIT20 ] to −1.0 ± 1.3‰, or matches DLR experiment-based intensities [S DLR-HIT16/UCL/Ames ] to 1.9 ± 3.7‰. This indicates the systematic deviations and uncertainties have been significantly reduced in S Ames-2021 . The S UCL2015 (or S HITRAN2016 ) have larger deviations (vs S DLR ) and uncertainties (vs S DLR , S NIST ) which are attributed to the less accurate Ames-1 PES adopted in UCL-296 line list calculation. The S Ames-2021 intensity of 12 C 16 O 2 and 13 C 16 O 2 is utilized to derive new absolute 13 C/ 12 C ratios for Vienna PeeDee Belemnite (VPDB) with uncertainty reduced by 1/3 or 2/3. Further evaluation of S Ames-2021 are carried out on those CO 2 bands discussed in the HITRAN2020 update paper. Consistent improvements and better accuracies are found in band-by-band analysis, except for those bands strongly affected by Coriolis couplings, or very weak bands measured with relatively larger experimental uncertainties. The Ames-2021 296 K IR line lists are generated for 13 CO 2 isotopologues, with 18,000 per and S 296K > 1E–31) cm/molecule cutoff and then combined with CDSD line positions (except 14 C 16 O 2 ). The Ames-2021 DMS and 296 K IR line lists represent a major improvement over previous CO 2 theoretical IR intensity studies, including Ames-2016, UCL-296, and recent UCL DMS 2021 update. A real 1 permille level of agreement and uncertainty will definitely require both more accurate PES and more accurate DMS.

Chemical calculations↗

Synchronizing computer clocks using a local area network

Researchers completed the first tests of a method to synchronize the clocks of networked computers to the National Institute of Standards and Technology (NIST) time scale. The method uses a server computer to disseminate the time to other clients on the same local-area network. The server is synchronized to NIST using the ACTS protocol over a dial-up telephone line. The software in both the server and the parameters of this model are used to adjust the time of the local clock and the interval between calibration requests in a statistically optimum way. The algorithm maximizes the time between calibrations while at the same time keeping the time of the local clock correct within a specific tolerance. The method can be extended to synchronize computers linked over wide-area networks, and an experiment to test the performance of the algorithms over such networks is being planned.

Levine, Judah↗

Flow behavior in liquid molding

The liquid molding (LM) process for manufacturing polymer composites with structural properties has the potential to significantly lower fabrication costs and increase production rates. LM includes both resin transfer molding and structural reaction injection molding. To achieve this potential, however, the underlying science base must be improved to facilitate effective process optimization and implementation of on-line process control. The National Institute of Standards and Technology (NIST) has a major program in LM that includes materials characterization, process simulation models, on-line process monitoring and control, and the fabrication of test specimens. The results of this program are applied to real parts through cooperative projects with industry. The key feature in the effort is a comprehensive and integrated approach to the processing science aspects of LM. This paper briefly outlines the NIST program and uses several examples to illustrate the work.

Hunston, D.↗

Development and calibration of UV/VUV radiometric sources

A program exists at NIST to calibrate radiometric sources for the spectral range from 118-350 nm. These include deuterium lamps, hollow-cathode lamps, RF-excited dimer lamps, and wall-stabilized argon arcs. Sources have been calibrated for and used by researchers in solar physics, astrophysics, atmospheric physics (ozone measurements), magnetically controlled fusion, and photobiology. The argon arcs were developed in our laboratory, and provide intense sources of both radiance and irradiance. Calibrations are performed relative to two primary sources, a wall-stabilized hydrogen arc and a 12,000 K black-body line arc, both developed in our laboratory. Also we recently have begun periodic calibrations on the NIST storage ring, SURF II, to insure consistency between our respective radiometric bases. Various sources have been calibrated for space' applications, including several which are flyable. Also, some development and testing of radiometers for semiconductor lithography were recently carried out with an intense argon arc source.

Bridges, J. M.↗

Microwave digestion preparation and ICP determination of boron in human plasma

A microwave digestion procedure, followed by Inductively Coupled Argon Plasma Spectroscopy, is described for the determination of boron (B) in human plasma. The National Institute of Standards and Technology (NIST) currently does not certify the concentration of B in any substance. The NIST citrus leaves 1572 (CL) Standard Reference Material (SRM) and wheat flour 1567a (WF) were chosen to determine the efficacy of digestion. CL and WF values compare favorably to those obtained from an open-vessel, wet digestion followed by ICP, and by neutron activation and mass spectrometric measurements. Plasma samples were oxidized by doubled-distilled ultrapure HNO3 in 120 mL PFA Teflon vessels. An MDS-81D microwave digestion procedure allows for rapid and relatively precise determination of B in human plasma, while limiting handling hazards and sources of contamination.

Ferrando, A. A.↗

Volume 14: The first SeaWiFS intercalibration round-robin experiment, SIRREX-1, July 1992

The results of the first Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-1), which was held at the Center for Hydro-Optics and Remote Sensing (CHORS) at San Diego State University (SDSU) on 27-31 July 1992 are presetend. Oceanographic radiometers to be used in the SeaWiFS Calibration and Validation Program will be calibrated by individuals from the National Aeronautics and Space Administration's (NASA's) Goddard Space Flight Center (GSFC), CHORS, and seven other laboratories. The purpose of the SIRREX experiments is to assure the radiometric standards used in all of these laboratories are referenced to the same scales of spectral irradiance and radiance, which will be maintained by GSFC and periodically recalibrated by the National Institute of Standards and Technology (NIST). The spectral irradiance scale of GSFC's FEL lamp number F269 (recalibrated by NIST in October 1992) was transferred to lamps belonging to the 9 participating laboratories; l set of lamp transfer measurements (involving 4 of the lamps) was precise to within less than 1 percent and meets SeaWiFS goals, but a second set (involving another 14 lamps) did not. The spectral radiance scale of the GSFC 40-inch integrating sphere source was transferred to integrating sphere radiance sources belonging to four of the other laboratories. Reflectance plaques, used for irradiance-to-radiance transfer by five of the laboratories, were compared, but spectral bidirectional reflectance distribution functions (BRDF's) were not determined quantitatively. Also reported are results of similar comparisons (in October 1992) between the GSFC scales of spectral irradiance and radiance and those used by the Hughes/Santa Barbara Research Center (SBRC) to calibrate and characterize the SeaWiFS instrument. This first set of intercalibration round-robin experiments was a valuable learning experience for all participants, and led to several important procedural changes, which will be implemented in the second SIRREX, to be held at CHORS in June 1993.

Mueller, James L.↗

Detailed study of oxidation/wear mechanism in lox turbopump bearings

Wear of 440C angular contact ball bearings of the phase 2 high pressure oxygen turbopump (HPOTP) of the space shuttle main engine (SSME) has been studied by means of various advanced nondestructive techniques (NDT) and modeled with reference to all known material, design, and operation variables. Three modes dominating the wear scenario were found to be the adhesive/sheer peeling (ASP), oxidation, and abrasion. Bearing wear was modeled in terms of the three modes. Lacking a comprehensive theory of rolling contact wear to date, each mode is modeled after well-established theories of sliding wear, while sliding velocity and distance are related to microsliding in ball-to-ring contacts. Microsliding, stress, temperature, and other contact variables are evaluated with analytical software packages of SHABERTH(TM)/SINDA(TM) and ADORE(TM). Empirical constants for the models are derived from NIST experiments by applying the models to the NIST wear data. The bearing wear model so established precisely predicts quite well the average ball wear rate for the HPOTP bearings. The wear rate has been statistically determined for the entire population of flight and development bearings based on Rocketdyne records to date. Numerous illustrations are given.

Chase, T. J.↗

SeaWiFS technical report series. Volume 16: The second SeaWiFS Intercalibration Round-Robin Experiment, SIRREX-2, June 1993

The results of the second Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-2), which was held at the Center for Hydro-Optics and Remote Sensing (CHORS) at San Diego State University on 14-25 Jun. 1993 are presented. SeaWiFS is an ocean color radiometer that is scheduled for launch in 1994. The SIRREXs are part of the SeaWiFS Calibration and Validation Program that includes the GSFC, CHORS, NIST, and several other laboratories. GSFC maintains the radiometric scales (spectral radiance and irradiance) for the SeaWiFS program using spectral irradiance standards lamps, which are calibrated by NIST. The purpose of each SIRREX is to assure that the radiometric scales which are realized by the laboratories who participate in the SeaWiFS Calibration and Validation Program are correct; that is, the uncertainties of the radiometric scales are such that measurements of normalized water-leaving radiance using oceanographic radiometers have uncertainties of 5%. SIRREX-1 demonstrated, from the internal consistency of the results, that the program goals would not be met without improvements to the instrumentation. The results of SIRREX-2 demonstrate that spectral irradiance scales realized using the GSFC standard irradiance lamp (F269) are consistent with the program goals, as the uncertainty of these measurements is assessed to be about 1%. However, this is not true for the spectral radiance scales, where again the internal consistency of the results is used to assess the uncertainty. This is attributed to inadequate performance and characterization of the instrumentation. For example, spatial nonuniformities, spectral features, and sensitivity to illumination configuration were observed in some of the integrating sphere sources. The results of SIRREX-2 clearly indicate the direction for future work, with the main emphasis on instrument characterization and the assessment of the measurement uncertainties so that the results may be stated in a more definitive manner.

Hooker, Stanford B.↗

Chemical engineering: Measurements for a competitive age

The NIST (National Institute of Standards and Technology) activities supporting chemical research, environmental research, combustion and fuel research, and related industries are described in this video. Highlights include private sector involvement in the research and associated and guest scientist programs, the calibration of customers' instruments, and the direct funding for the NIST research projects by outside industries.

Source record↗

High resolution time interval counter

In recent years, we have developed two types of high resolution, multi-channel time interval counters. In the NIST two-way time transfer MODEM application, the counter is designed for operating primarily in the interrupt-driven mode, with 3 start channels and 3 stop channels. The intended start and stop signals are 1 PPS, although other frequencies can also be applied to start and stop the count. The time interval counters used in the NIST Frequency Measurement and Analysis System are implemented with 7 start channels and 7 stop channels. Four of the 7 start channels are devoted to the frequencies of 1 MHz, 5 MHz or 10 MHz, while triggering signals to all other start and stop channels can range from 1 PPS to 100 kHz. Time interval interpolation plays a key role in achieving the high resolution time interval measurements for both counters. With a 10 MHz time base, both counters demonstrate a single-shot resolution of better than 40 ps, and a stability of better than 5 x 10(exp -12) (sigma(sub chi)(tau)) after self test of 1000 seconds). The maximum rate of time interval measurements (with no dead time) is 1.0 kHz for the counter used in the MODEM application and is 2.0 kHz for the counter used in the Frequency Measurement and Analysis System. The counters are implemented as plug-in units for an AT-compatible personal computer. This configuration provides an efficient way of using a computer not only to control and operate the counters, but also to store and process measured data.

Zhang, Victor S.↗

Measurements of dimethyl sulfide and SO2 during GTE/CITE 3

As part of NASA's Tropospheric Experiment Chemical Instrumentation Test and Evaluation (GTE/CITE 3) Sulfur Gas Intercomparison, we conducted measurements of dimethyl sulfide (DMS) and SO2 using two techniques well suited for sampling from an aircraft due to their simplicity of design. DMS was collected by preconcentration on gold wire preceded by a KOH-impregnated filter oxidant scrubber, and analyzed by gas chromatography with flame photometric detection. SO2 was collected on K2CO3/glycerol-impregnated filters and analyzed by ion chromatography. In blind tests, both techniques produced excellent agreement with National Institutes of Standards and Technology (NIST) standards. For field measurements, the DMS technique produced excellent correlation with the mean of the six different techniques intercompared. For SO2, the five techniques intercompared were rather poorly correlated, but correlations between the three techniques which passed NIST standards tests were somewhat better. Our SO2 filter measurements exhibited rather large uncertainties due to higher than normal variabiltiy of the filter blanks, which we believe was caused by extended storage in the field. In measurements conducted off the coast of Natal, Brazil, a diurnal afternoon minimum in DMS concentrations accompanied by a corresponding maximum in SO2 concentrations was observed. However, due to rather large uncertainties in the SO2 measurements, any conclusions about the SO2 trend must by considered tentative.

Ferek, Ronald J.↗

Sea WiFS Technical Report Series: The fourth SeaWIFS Intercalibration Round-Robin Experiment (SIRREX-4), May 1995

This report documents the fourth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-4), which was held at the National Institute of Standards and Technology (NIST) on 3-10 May 1995. The agenda for SIRREX-4 was established by a consensus reached at the conclusion of SIRREX-3: there should be an emphasis on training and work to foster and encourage uniform use of accepted protocols for calibrating radiometric instruments in the laboratory. The goal was to host the activity in a setting where proper techniques could be discussed and demonstrated. It seemed appealing to split the day between morning lectures and afternoon laboratory exercises or practicals. The former gave the user community a chance to present what was important to them and discuss it with acknowledged experts in radiometry, while the latter presented a unique opportunity for training and evaluation in the presence of these same experts. The five laboratory sessions were concerned with (1) determining the responsivity of a spectroradiometer and the spectral radiance of an unknown integrating sphere source, (2) demonstrating spectral field calibration procedures for an integrating sphere using three different instruments, (3) measuring spectral radiance using the plaque method, (4) setting up and aligning lamp calibration transfer standards using the NIST specifications for irradiance measurements, and (5) characterizing radiometric instruments. In addition to documenting some supplemental studies performed outside the laboratory sessions, this report includes an evaluation of the hardware that has been used during the SIRREX activities plus a critical evaluation of SIRREX objectives.

Johnson, B. Carol↗

Laboratory Astrophysics using a Microcalorimeter and Bragg Crystal Spectrometer on an Electron Beam Ion Trap

During the past year we have been preparing our new microcalorimeter system for permanent delivery to the NIST EBIT. Unfortunately, there have been delays due to technical difficulties in the fabrication of the two-stage adiabatic demagnetization refrigerator and in the life expectancy of the thin windows used for internal thermal baffling of the infrared radiation. These problems have been solved and we are completing tests of the entire system and it will be set up at NIST during the first week of May. Several photos of the new system are shown in Figures 1A and 1B. This microcalorimeter spectrometer only requires helium refills every three days (as opposed to every 24 hours) and it will hold a temperature! of 65 mK for up to 48 hours (as opposed to 8 hours). Consequently, the efficiency of data acquisition will improve dramatically. In parallel we have published a paper that reviews our previous work (Takacs et al. 2003), especially on Fe XVII, in the context of recent measurements by other groups. This paper is included. We highlight a recent measurement of a broad band spectrum of Fe in Figure 2 that simultaneously includes L and K radiation. It is compared with the simulated spectrum of the Perseus Cluster that one could expect to obtain with a microcalorimeter in the focus of a grazing incidence telescope such as the one being designed for Constellation X. Both the charge state distributions and the relative intensity ratios of the emission lines within the particular charge state are very similar in the two spectra. This further demonstrates the importance and relevance of the laboratory measurements in predicting the components of cosmic spectra.

Brinton, John C.↗

Measuring Thermal Conductivity at LH2 Temperatures

For many years, the National Institute of Standards and Technology (NIST) produced reference materials for materials testing. One such reference material was intended for use with a guarded hot plate apparatus designed to meet the requirements of ASTM C177-97, "Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus." This apparatus can be used to test materials in various gaseous environments from atmospheric pressure to a vacuum. It allows the thermal transmission properties of insulating materials to be measured from just above ambient temperature down to temperatures below liquid hydrogen. However, NIST did not generate data below 77 K temperature for the reference material in question. This paper describes a test method used at NASA's Marshall Space Flight Center (MSFC) to optimize thermal conductivity measurements during the development of thermal protection systems. The test method extends the usability range of this reference material by generating data at temperatures lower than 77 K. Information provided by this test is discussed, as are the capabilities of the MSFC Hydrogen Test Facility, where advanced methods for materials testing are routinely developed and optimized in support of aerospace applications.

Selvidge, Shawn↗

Succinonitrile Purification Facility

The Succinonitrile (SCN) Purification Facility provides succinonitrile and succinonitrile alloys to several NRA selected investigations for flight and ground research at various levels of purity. The purification process employed includes both distillation and zone refining. Once the appropriate purification process is completed, samples are characterized to determine the liquidus and/or solidus temperature, which is then related to sample purity. The lab has various methods for measuring these temperatures with accuracies in the milliKelvin to tenths of milliKelvin range. The ultra-pure SCN produced in our facility is indistinguishable from the standard material provided by NIST to well within the stated +/- 1.5mK of the NIST triple point cells. In addition to delivering material to various investigations, our current activities include process improvement, characterization of impurities and triple point cell design and development. The purification process is being evaluated for each of the four vendors to determine the efficacy of each purification step. We are also collecting samples of the remainder from distillation and zone refining for analysis of the constituent impurities. The large triple point cells developed will contain SCN with a melting point of 58.0642 C +/- 1.5mK for use as a calibration standard for Standard Platinum Resistance Thermometers (SPRTs).

Source record↗

Effects of regenerator geometry on pulse tube refrigerator performance

This paper gives results of the cooling performance of a double-inlet pulse tube refrigerator using various regenerators. The same pulse tube was used for all the experiments and measured 4.76 mm in diameter and 46.2 mm in length. A commercial linear compressor with a swept volume of 4 cm3 was used in these experiments. The operating conditions were held constant at a mean pressure of 2.0 MPa and a frequency of 54 Hz. Using finite difference software called REGEN3.1, developed at NIST, and recent experiment results, we optimized a series of regenerators based on dimensions, materials and screen packing. The values used for calculating the thermal conduction through stacked screens by REGEN3.1 were based on recent experimental results from NIST. The regenerator tubes were designed using 316 stainless steel and titanium materials. The regenerator matrices investigated were 400-mesh and 500-mesh stainless steel screen. The valve settings for both orifices were adjusted to minimize the no-load temperature for all regenerators. A cooling capacity curve from 0 to 3 W was also determined. The performance of the pulse tube refrigerator using the different regenerators is discussed. The experimental results from the various regenerators are evaluated and compared with their corresponding numerically calculated coefficient of performance (COP) and regenerator design as determined by REGEN3.1.

NASA Discipline Life Sciences Technologies↗

A Comparison of Experimental EPMA Data and Monte Carlo Simulations

Monte Carlo (MC) modeling shows excellent prospects for simulating electron scattering and x-ray emission from complex geometries, and can be compared to experimental measurements using electron-probe microanalysis (EPMA) and phi(rho z) correction algorithms. Experimental EPMA measurements made on NIST SRM 481 (AgAu) and 482 (CuAu) alloys, at a range of accelerating potential and instrument take-off angles, represent a formal microanalysis data set that has been used to develop phi(rho z) correction algorithms. The accuracy of MC calculations obtained using the NIST, WinCasino, WinXray, and Penelope MC packages will be evaluated relative to these experimental data. There is additional information contained in the extended abstract.

Carpenter, P. K.↗