Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluating 240 Pu Prompt Fission Neutron Spectra Including Chi-Nu Experimental Data

This report documents an evaluation of 240 Pu prompt fission neutron spectra (PFNS) including Chi-Nu experimental data. This work is a FY2025 Q4 NCSP (Nuclear Criticality Safety Program) milestone and named a “strategic priority”. This evaluation is new; it differs substantially from the most recent evaluation included in the ENDF/B library, which was for ENDF/B-VII.1 and then carried over unchanged to ENDF/B-VIII.1. The key difference between ENDF/B-VIII.1 and the new evaluation is that we have, for the first time, realistic experimental 240 Pu PFNS covering a broad incident and outgoing neutron energy range.

240Pu↗

New prompt fission neutron spectra measurements in the 238 U(n,f) reaction with a dedicated setup at LANSCE/WNR

A new prompt fission neutron spectra (PFNS) measurement in the 238 U(n,f) reaction was performed at LANSCE/WNR facility. Evaluated data show discrepancies on the low (below 1 MeV) and high (above 5 MeV) energy parts in the PFNS for different major and minor actinides. The goal is to improve these measurements in a wide range of incident energy. The energy of the incoming neutron, inducing the fission, and the prompt neutron energies, are measured by time-of-flight method. A dedicated fission chamber was developed, in order to improve alpha-fission discrimination, timing resolution, actinide mass, and to reduce the amount of neutron scattering. To detect prompt neutrons, the 54 Chi-Nu scintillator cells array were surrounding the fission chamber. High statistics were recorded during this experiment, allowing a precise study of PFNS behavior as a function of incident neutron energy, from 1 MeV to 200 MeV. In conclusion, this experiment also showed that all the new tools developed to improve PFNS measurements are performing. Therefore, measurements of PFNS with others actinides such as 239 Pu are planned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning-assisted identification of potential sources of bias in measurements of prompt-fission neutron spectra

Unrecognized sources of uncertainty (USU) can bias the reported mean and/or covariance of experimental nuclear data. These biases, in turn, can propagate through evaluated nuclear data to application simulations or may poorly inform nuclear theory that is fitted to the experimental data. Such unknown sources of bias must be tied to the inherent physical constituents of the measurements such as the characteristics of a detector response or a background reduction technique. Here, in this article, a sparse Bayesian learning model is used to support experts in their efforts to identify and characterize USU in experimental prompt fission neutron spectra (PFNS) for spontaneous fissioning of 252 Cf by linking observed biases to features of the measurement system. Three different bias components were found. The first acts as a verification case for the algorithm as it identifies a bias coming from a well-known source related to the use of 6 Li in the neutron detection system. The second two cases demonstrate how this method can benefit the evaluation of experimental nuclear data by identifying, quantifying, and relating unknown biases to potential causes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Templates of expected measurement uncertainties for prompt fission neutron spectra

In this paper, we provide templates of uncertainty sources expected to appear for three measurement types of prompt fission neutron spectra (PFNS): (1) shape measurements, (2) clean-ratio shape, that is the monitor PFNS are measured in nearly exactly the same surrounding as the PFNS of interest, and (3) indirect ratios, where the detector efficiency is backed out from PFNS monitor measurements. Information is also listed that is needed to faithfully include PFNS in nuclear data evaluations to guide experimenters on how to best report data and metadata for their measurements. These templates also suggest a typical range of pertinent uncertainty values and their correlations in case realistic uncertainties cannot be estimated from information on the measurement itself. The templates were based on a literature review, information found in EXFOR for 252 Cf, 235, 238 U, and 239 Pu PFNS, and enhanced by expertise from experimenters contributing to these PFNS templates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measured and Calculated Neutron Spectra and Dose Equivalent Rates at High Altitudes; Relevance to SST Operations and Space Research

Results of the NASA Langley-New York University high-altitude radiation study are presented. Measurements of the absorbed dose rate and of secondary fast neutrons (1 to 10 MeV energy) during the years 1965 to 1971 are used to determine the maximum radiation exposure from galactic and solar cosmic rays of supersonic transport (SST) and subsonic jet occupants. The maximum dose equivalent rates that the SST crews might receive turn out to be 13 to 20 percent of the maximum permissible dose rate (MPD) for radiation workers (5 rem/yr). The exposure of passengers encountering an intense giant-energy solar particle event could exceed the MPD for the general population (0.5 rem/yr), but would be within these permissible limits if in such rare cases the transport descends to subsonic altitude; it is in general less than 12 percent of the MPD. By Monte Carlo calculations of the transport and buildup of nucleons in air for incident proton energies E of 0.02 to 10 GeV, the measured neutron spectra were extrapolated to lower and higher energies and for galactic cosmic rays were found to continue with a relatively high intensity to energies greater than 400 MeV, in a wide altitude range. This condition, together with the measured intensity profiles of fast neutrons, revealed that the biologically important fast and energetic neutrons penetrate deep into the atmosphere and contribute approximately 50 percent of the dose equivalant rates at SST and present subsonic jet altitudes.

Foelsche, T.↗

Analysis of Water Coupling in Inelastic Neutron Spectra of Uranyl Fluoride

Inelastic neutron scattering (INS) is uniquely sensitive to hydrogen due to its comparatively large thermal neutron scattering cross-section (82 b). Consequently, the inclusion of water in real samples presents significant challenges to INS data analysis due directly to the scattering strength of hydrogen. Here, we investigate uranyl fluoride (UO 2 F 2 ) with inelastic neutron scattering. UO 2 F 2 is the hydrolysis product of uranium hexafluoride (UF 6 ), and is a hygroscopic, uranyl-ion containing particulate. Raman spectral signatures are commonly used for inferential understanding of the chemical environment for the uranyl ion in UO 2 F 2 , but no direct measurement of the influence of absorbed water molecules on the overall lattice dynamics has been performed until now. To deconvolute the influence of waters on the observed INS spectra, we use density functional theory with full spectral modeling to separate lattice motion from water coupling. In particular, we present a careful and novel analysis of the Q-dependent Debye–Waller factor, allowing us to separate spectral contributions by mass, which reveals preferential water coupling to the uranyl stretching vibrations. Coupled with the detailed partial phonon densities of states calculated via DFT, we infer the probable adsorption locations of interlayer waters. We explain that a common spectral feature in Raman spectra of uranyl fluoride originates from the interaction of water molecules with the uranyl ion based on this analysis. In conclusion, the Debye–Waller analysis is applicable to all INS spectra and could be used to identify light element contributions in other systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of neutron spectra in the experimental reactor LR-0

The measurement of fast neutron fluxes is important in many areas of nuclear technology. It affects the stability of the reactor structural components, performance of fuel, and also the fuel manner. The experiments performed at the LR-0 reactor were in the past focused on the measurement of neutron field far from the core, in reactor pressure vessel simulator or in biological shielding simulator. In the present the measurement in closer regions to core became more important, especially measurements in structural components like reactor baffle. This importance increases with both reactor power increase and also long term operation. Other important task is an increasing need for the measurement close to the fuel. The spectra near the fuel are aimed due to the planned measurements with the FLIBE salt, in FHR / MSR research, where one of the task is the measurement of the neutron spectra in it. In both types of experiments there is strong demand for high working count rate. The high count rate is caused mainly by high gamma background and by high fluxes. The fluxes in core or in its vicinity are relatively high to ensure safe reactor operation. This request is met in the digital spectroscopic apparatus. All experiments were realized in the LR-0 reactor. It is an extremely flexible light water zero-power research reactor, operated by the Research Center Rez (Czech Republic). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Spectra, Fluence and Dose Rates from Bare and Moderated Cf-252 Sources

A new, stronger 252 Cf source (serial number SR-CF-3050-OR) was obtained from Oak Ridge National Laboratory (ORNL) in 2014 to supplement the existing 252 Cf sources which had significantly decayed. A new instrument positioning track system was designed and installed by Hopewell Designs, Inc. in 2011. The neutron field from the new, stronger 252 Cf source in the modified calibration environment needed to be characterized as well as the modified neutron fields produced by the new source and seven different neutron moderators. Comprehensive information about our 252 Cf source, its origin, production, and isotopic content and decay characteristics needed to be compiled as well. This technical report is intended to address these issues.

07 ISOTOPE AND RADIATION SOURCES↗

Sci—Fri PM: Dosimetry—02: A Nested Neutron Spectrometer to Measure Neutron Spectra in Radiotherapy

During high-energy radiotherapy treatments, neutrons are produced in the head of the linac through photonuclear interactions. This has been a concern for many years as photoneutrons contribute to the accepted, yet unwanted, out-of-field doses that pose an iatrogenic risk to patients and an occupational risk to personnel. Presently, in-room neutron measurements are difficult and time-consuming and have traditionally been carried out using Bonner spheres with activation foils and TLDs. In this work, a new detector, the Nested Neutron Spectrometer (NNS) is tested for use in radiotherapy bunkers. The NNS is designed for easy handling and is more practical than the traditional Bonner spheres. The NNS, operated in current mode, was used to measure the dose equivalent, average energy and energy spectrum at several positions in a radiotherapy bunker. The average energy and spectra were compared to Monte Carlo simulations while the dose equivalent was compared to bubble detector measurements. The average energies, as measured by the NNS and Monte Carlo simulations, differed by approximately 30% across the bunker. Measurements of the dose equivalent using the NNS and the bubble detectors agreed within 50% in the maze and less than 10% close to the linac head. Apart from some discrepancies at thermal energies, we also found reasonable agreement between NNS-measured and Monte Carlo-simulated spectra at a number of locations within our radiotherapy bunker. Our results demonstrate that the NNS is a suitable detector to be used in high dose-rate radiotherapy environments.

07 ISOTOPE AND RADIATION SOURCES↗

The effect of turbulent kinetic energy on inferred ion temperature from neutron spectra

Measuring the width of the energy spectrum of fusion-produced neutrons from deuterium (DD) or deuterium-tritium (DT) plasmas is a commonly used method for determining the ion temperature in inertial confinement fusion (ICF) implosions. In a plasma with a Maxwellian distribution of ion energies, the spread in neutron energy arises from the thermal spread in the center-of-mass velocities of reacting pairs of ions. Fluid velocities in ICF are of a similar magnitude as the center-of-mass velocities and can lead to further broadening of the neutron spectrum, leading to erroneous inference of ion temperature. Motion of the reacting plasma will affect DD and DT neutrons differently, leading to disagreement between ion temperatures inferred from the two reactions. This effect may be a contributor to observations over the past decades of ion temperatures higher than expected from simulations, ion temperatures in disagreement with observed yields, and different temperatures measured in the same implosion from DD and DT neutrons. This difference in broadening of DD and DT neutrons also provides a measure of turbulent motion in a fusion plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpreting inertial fusion neutron spectra

A burning laser fusion plasma produces a neutron spectrum first described by Brysk (1973 Plasma Phys. Control. Fusion 15 611). This and more recent work deals with the spectrum produced by a single fluid element. The distribution of temperatures and velocities in multiple fluid elements combine in any real spectrum; here we derive formulas for how the neutron spectrum averages these contributions. The single element momentum spectrum is accurately Gaussian, but the multi-element spectrum exhibits higher moments. In particular, the skew and kurtosis are likely to be large enough to measure. Even the single fluid element spectrum may exhibit measurable directional anisotropy, so that instruments with different lines of sight should see different yields, mean velocities, mean temperatures, and higher moments. Finally, we briefly discuss how scattering in the imploded core modifies the neutron spectrum by changing the relative weighting of fuel regions with different temperatures and velocities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗