Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

β-Delayed One and Two Neutron Emission Probabilities Southeast of 132 Sn and the Odd-Even Systematics in r-Process Nuclide Abundances

Here, the β-delayed one- and two-neutron emission probabilities (P 1n and P 2n ) of 20 neutron-rich nuclei with N≥82 have been measured at the RIBF facility of the RIKEN Nishina Center. P 1n of 130,131 Ag, 133,134 Cd, 135,136 In, and 138,139 Sn were determined for the first time, and stringent upper limits were placed on P2n for nearly all cases. β-delayed two-neutron emission (β2n) was unambiguously identified in 133 Cd and 135,136 In, and their P 2n were measured. Weak β2n was also detected from 137,138 Sn. Our results highlight the effect of the N=82 and Z=50 shell closures on β-delayed neutron emission probability and provide stringent benchmarks for newly developed macroscopic-microscopic and self-consistent global models with the inclusion of a statistical treatment of neutron and γ emission. The impact of our measurements on r-process nucleosynthesis was studied in a neutron star merger scenario. Our P 1n and P 2n have a direct impact on the odd-even staggering of the final abundance, improving the agreement between calculated and observed Solar System abundances. The odd isotope fraction of Ba in r-process-enhanced (r-II) stars is also better reproduced using our new data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of anode shape on correlation of neutron emission with pinch energy for a 2.7 kJ Mather-type plasma focus device

Correlation of neutron emission with pinch energy for a Mather-type plasma focus energized by a single capacitor 12.5 muF, 21 kV (2.7 kJ) is investigated by employing time resolved and time integrated detectors for two different anode shapes. The maximum average neutron yield of about 1.3x10{sup 8} per shot is recorded with cylindrical anode, that increases to 1.6x10{sup 8} per shot for tapered anode. At optimum pressure the input energy converted to pinch energy is about 24% for cylindrical anode as compared to 36% for tapered anode. It is found that the tapered anode enhances neutron flux about 25+-5% both in axial and radial directions and also broadens the pressure range for neutron emission as well as pinch energy. The neutron yield and optimum gas filling pressures are found strongly dependent on the anode shape.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bi-Modal Model for Neutron Emissions from PuO{sub 2} and MOX Holdup

The measurement of uranium and plutonium holdup in plants during process activity and for decommissioning is important for nuclear safeguards and material control. The amount of plutonium and uranium holdup in glove-boxes, pipes, ducts, and other containers has been measured for several decades using both neutron and gamma-ray techniques. For the larger containers such as hot cells and glove-boxes that contain processing equipment, the gamma-ray techniques are limited by self-shielding in the sample as well as gamma absorption in the equipment and associated shielding. The neutron emission is more penetrating and has been used extensively to measure the holdup for the large facilities such as the MOX processing and fabrication facilities in Japan and Europe. In some case the totals neutron emission rates are used to determine the holdup mass and in other cases the coincidence rates are used such as at the PFPF MOX fabrication plant in Japan. The neutron emission from plutonium and MOX has 3 primary source terms: 1) Spontaneous fission (SF) from the plutonium isotopes, 2) The (α,n) reactions from the plutonium alpha particle emission reacting with the oxygen and other impurities, and 3) Neutron multiplication (M) in the plutonium and uranium as a result of neutrons created by the first two sources. The spontaneous fission yield per gram is independent of thickness, whereas, the above sources 2) and 3) are very dependent on the thickness of the deposit. As the effective thickness of the deposit becomes thin relative to the alpha particle range, the (α,n) reactions and neutrons from multiplication (M) approach zero. In any glove-box, there will always be two primary modes of holdup accumulation, namely direct powder contact and non-contact by air dispersal. These regimes correspond to surfaces in the glove-box that have come into direct contact with the process MOX powder versus surface areas that have not had direct contact with the powder. The air dispersal of PuO{sub 2} particles has been studied for several decades by health physicists, because the primary health hazard of plutonium is breathing the airborne particles. The air dispersal mechanism results from the smaller particles in the top layer of powder that are lifted into the air by the electrostatic charge buildup from the alpha decay process, and the air convection carries the particles to new more distant locations. If there is open plutonium powder in a glove-box, the surfaces at more distant locations will become contaminated over time. The range of an alpha particle in a solid or powder is a function of the particle energy, the material density, and the atomic number A of the material. The average energy of a plutonium alpha particle is ∼5.2 MeV and the range in air is ∼37 mm. The range in other materials can be estimated via the Bragg-Kleenman equation. For plutonium, A is 94, and the typical density for a single particle is ∼11.5 g/cm{sup 3}, but for a powder, the density would be less because of the air packing fraction. The significance of the small diameter is that the range of the alpha particle is ∼50 μm for powder density 2.5 and significantly less for a single particle with density 11.5, so the thin deposit of separate small particles will have a greatly reduced (α,n) yield. The average alpha transit length to the surface in the isolated MOX particle would be < 2.5 μm; whereas, the range of the alpha particle is much longer. Thus, most of the alpha particles would escape from the MOX particle and be absorbed by the walls and air. The air dispersal particles will have access to a large surface area that includes the walls, whereas, the powder contact surface area will be orders of magnitude smaller. Thus, the vast majority of the glove-box surface area does not produce the full (α,n) reaction neutron yield, even from the O{sub 2} in the PuO{sub 2} as well as any impurity contamination such as H{sub 2}O. To obtain a more quantitative estimate of the neutron (α,n) yields as a function of holdup deposit thickness, we have used MCNPX calculations to estimate the absorption of alpha particles in PuO{sub 2} holdup deposits. The powder thickness was varied from 0.1 μm to 5000 μm and the alpha particle escape probability was calculated. As would be expected, as the thickness approaches zero, the escape probability approaches 1.0, and as the thickness gets much greater than the alpha particle range (∼50 μm), the escape probability becomes small. Typically, the neutron holdup calibration measurement are performed using sealed containers of thick MOX that has all 3 sources of neutrons [SF, (α,n), and M], and no significant impurities. Thus, the calibration counting rates need to include corrections for M and (α,n) yields that are different for the holdup compared with the calibration samples. If totals neutron counting is used for the holdup measurements, the variability of the (α,n) term needs to be considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated Neutron Emissions from 252 Cf

This paper presents new experimental results of correlated, prompt neutron emission from the spontaneous fission of 252 Cf. Specifically, we present correlated-neutron emission probabilities and average energies for two detected neutrons as a function of the angle between the two neutrons. Finally, experimental results are compared to several Monte Carlo models that include the number, energy, and angular distributions of prompt neutrons from fission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploring 𝛽 decay and 𝛽-delayed neutron emission in exotic 46,47 Cl isotopes

In this paper, 𝛽 − and 𝛽-delayed neutron decays of 46,47 Cl are reported from an experiment carried out at the National Superconducting Cyclotron Laboratory using the Beta Counting System. The half-lives of both 46 Cl and 47 Cl were extracted. Based on the delayed 𝛾-ray transitions observed, the level structure of 𝑁=28 46 Ar was determined. Completely different sets of excited states above the first 2 + state in 46 Ar were populated in the 46 Cl 𝛽⁢0⁢𝑛 and 47 Cl 𝛽⁢1⁢𝑛 decay channels. Two new 𝛾-ray transitions in 47 Ar were identified from the very weak 47 Cl 𝛽⁢0⁢𝑛 decay. Furthermore, 46 Cl 𝛽⁢1⁢𝑛 and 47 Cl 𝛽⁢2⁢𝑛 were also observed to yield different population patterns for levels in 45 Ar, including states of different parities. Here, the experimental results allow us to address some of the open questions related to the delayed neutron emission process. For isotopes with large neutron excess and high 𝑄 𝛽 values, delayed neutron emission remains an important decay mode and can be utilized as a powerful spectroscopic tool. Experimental results were compared with shell-model calculations using the FSU and 𝑉 MU effective interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector

Neutron emission measurement at the HL-2A tokamak device with a liquid scintillation detector is described. The detector was placed at a location with little structure material in the field of view, and equipped with a gain monitoring system which could provide the possibility to evaluate the gain variation as well as to correct for the detector response. Time trace of the neutron emissivity was obtained and it was consistent with the result of a standard {sup 235}U fission chamber. During the plasma discharge the neutron yield could vary by about four orders of magnitude and the fluctuation of the detector gain was up to about 6%. Pulse height spectrum of the liquid scintillation detector was constructed and corrected with the aid of the gain monitoring system, and the correction was found to be essential for the assessment of the neutron energy spectrum. This successful measurement offered experience and confidence for the application of liquid scintillation detectors in the upcoming neutron camera system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intense Pulsed Neutron Emission from a Compact Pyroelectric Driven Accelerator

Intense pulsed D-D neutron emission with rates >10{sup 10} n/s during the pulse, pulse widths of {approx}100's ns, and neutron yields >10 k per pulse are demonstrated in a compact pyroelectric accelerator. The accelerator consists of a small pyroelectric LiTaO{sub 3} crystal which provides the accelerating voltage and an independent compact spark plasma ion source. The crystal voltage versus temperature is characterized and compare well with theory. Results show neutron output per pulse that scales with voltage as V{approx}1.7. These neutron yields match a simple model of the system at low voltages but are lower than predicted at higher voltages due to charge losses not accounted for in the model. Interpretation of the data against modeling provides understanding of the accelerator and in general pyroelectric LiTaO{sub 3} crystals operated as charge limited negative high voltage targets. The findings overall serve as the proof-of-principle and basis for pyroelectric neutron generators that can be pulsed, giving peak neutron rates orders of magnitude greater than previous work, and notably increase the potential applications of pyroelectric based neutron generators.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Intense pulsed neutron emission from a compact pyroelectric driven accelerator

Intense pulsed D-D neutron emission with rates of >10{sup 10} n/s during the pulse, pulse widths of approximately hundreds of nanoseconds and neutron yields of greater than 10 000 per pulse, are demonstrated in a compact pyroelectric accelerator. The accelerator consists of a small pyroelectric LiTaO{sub 3} crystal that provides the accelerating voltage and an independent compact spark plasma ion source. The crystal voltage versus temperature is characterized and compares well with theory. Results show neutron output per pulse that scales with voltage as V{sup {approx}}{sup 1.7}. These neutron yields match a simple model of the system at low voltages but are lower than predicted at higher voltages due to charge losses not accounted for in the model. Interpretation of the data against modeling provides understanding of the accelerator and in general pyroelectric LiTaO{sub 3} crystals operated as charge limited negative high voltage targets. The findings overall serve as the proof of principle and basis for pyroelectric neutron generators that can be pulsed, giving peak neutron rates orders of magnitude greater than previous work and notably increase the potential applications of pyroelectric based neutron generators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Fast Measurement System of Neutron Emission Profile Using a Digital Signal Processing Technique in JT-60U

Neutron emission profiles are routinely measured in JT-60U Tokamak. Stinbene neuron detectors (SNDs), which combine a Stilbene organic crystal scintillation detector (Stilbene detector) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure neutron flux efficiently. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to {approx}1x 10{sup 5} counts/s due to the dead time of the analog PSD circuit. To overcome this issue, a digital signal processing (DSP) system using a Flash-ADC has been developed. In this system, anode signals from the photomultiplier of the Stilbene detector are fed to the Flash ADC and digitized. Then, the PSD between neutrons and gamma-rays are performed using software. The photomultiplier tube is also modified to suppress and correct gain fluctuation of the photomultiplier. The DSP system has been installed in the center channel of the vertical neutron collimator system in JT-60U and applied to measurements of neutron flux in JT-60U experiments. Neutron flux are successfully measured with count rate up to {approx}1x 10{sup 6} counts/s without the effect of pile up of detected pulses. The performance of the DSP system as a neutron detector is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Importance of the (n,gamma) Cm-247 Evaluation on Neutron Emission in Fast Reactor Fuel Cycle Analysis

As part of the GNEP program, it is envisioned to build a fast reactor for the transmutation of minor actinides. The spent nuclear fuel from the current fleet of light water reactors would be recycled, the current baseline is the UREX+1a process, and would act as a feed for the fast reactor. As the fuel is irradiated in a fast reactor a certain quantity of minor actinides would thus build up in the fuel stream creating possible concerns with the neutron emission of these minor actinides for fuel transportation, handling and fabrication. Past neutronic analyses had not tracked minor actinides above Cm-246 in the transmutation chain, because of the small influence on the overall reactor performance and cycle parameters. However, when trying to quantify the neutron emission from the recycled fuel with high minor actinide content, these higher isotopes play an essential role and should be included in the analysis. In this paper, the influence of tracking these minor actinides on the calculated neutron emission is presented. Also presented is the particular influence of choosing a different evaluated cross section data set to represent the minor actinides above Cm-246. The first representation uses the cross-sections provided by MC2-2 for all isotopes, while the second representation uses infinitely diluted ENDF/BVII.0 cross-sections for Cm-247 to Cf-252 and MC2-2 for all other isotopes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Neutron Emission Rates of Commercial 252 Cf Sources

Accurate knowledge of 252 Cf neutron emission rates is critical for modeling and fast-neutron experiments, yet commercial sources are often supplied without traceable calibration or uncertainty estimates. This report describes a method to characterize 252 Cf sources using a pulse-shape-discrimination (PSD) scintillator. The scintillator was efficiency-calibrated against a time-tagged 252 Cf fission chamber manufactured at ORNL over 40 years ago. Isotopic evolution of the calibration source was modeled using Bateman equations to account for changes in the effective average neutrons per fission at the time of measurement. The calibrated scintillator was then used to measure absolute emission rates of several commercial 252 Cf sources, revealing deviations of up to 12% from nominal manufacturer values. This methodology provides a practical approach for establishing uncertainty-quantified 252 Cf neutron emission rates, improving fidelity in simulations and supporting the accurate interpretation of measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

β -delayed neutron emission of Mn 64 , Cr 62 , and Fe 65

The β-decay properties of nuclei near the second nuclear “island of inversion” around neutron rich nuclei with neutron number 40 are important tests of nuclear structure models and interactions. In particular, the β-delayed neutron emission branch (Ρ n ), is useful for investigating β-strength and neutron-γ competition above the neutron separation energies of the daughter nuclei. We report new constraints for Ρ n values for three nuclei in the region: 62 Cr (Ρ n <1%), 64 Mn (Ρ n = 1.5⁢(6)%), and 65 Fe (Ρ n < 1%), measured with the Neutron Emission Ratio Observer (NERO) neutron long counter system and the Beta Counting Station (BCS) at the National Superconducting Cyclotron Laboratory (NSCL). Our results resolve the large discrepancy between previous direct and indirect measurements for 64 Mn and confirm the predictions of global theoretical models when a statistical treatment of the γ and neutron decays of the daughter states is included. Here we also obtain improved half-lives for 62 Cr [206(5) ms] and the short-lived isomer in the 62 Fe daughter [112(7) ms] from β-delayed γ emission data obtained in the same experiment with the Summing NaI (SuN) total absorption spectrometer. Finally, we use γ emission data to obtain a new upper limit for the 62 Cr β-decay population of the long-lived isomeric state in 62 Mn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self-consistent approach to β-decay and delayed multi-neutron emission

The beta-decay half-lives and delayed multi- neutron emission branchings for the nuclei near the new neutron shell N = 34 are treated within self-consistent Density Functional + Continuum QRPA model (DF + CQRPA). A comparison with the recent self-consistent calculations from relativistic QRPA and standard (semi-microscopic) FRDM is performed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

β -delayed neutron emission from Ga 85

Here, decay of 85 Ga was studied by means of β-neutron-γ spectroscopy. A pure beam of 85 Ga was produced at the Holifield Radioactive Ion Beam Facility using a resonance ionization laser ion source and a high-resolution electromagnetic separator. The β-delayed neutron emission probability was measured for the first time, yielding 70(5)%. An upper limit of 0.1% for β-delayed two-neutron emission was also experimentally established for the first time. A detailed decay scheme including absolute γ-ray intensities was obtained. Lastly, results are compared with theoretical β-delayed emission models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-emission mechanisms in the {sup 115}In({alpha}, xn) reactions

Spectra and angular distributions of neutrons from the {sup 115}In({alpha}, xn) reactions were measured at {alpha}-particle energies of 16, 18, 27, and 45 MeV. The measurements were performed with time-of-flight neutron spectrometers at pulsed accelerators of charged particles. The data obtained in this way were analyzed within the models of equilibrium, preequilibrium, and direct reaction mechanisms. The exact formalism of Hauser-Feshbach statistical theory was used in the calculations, level densities in residual nuclei excited in the reactions under consideration being found from the neutron evaporation spectra in the (p, n) reactions on tin isotopes. Contributions from equilibrium, preequilibrium, and direct neutron emission were studied in a wide range of {alpha}-particle energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

β-decay and β-delayed Neutron Emission Measurements at GSI-FRS Beyond N=126, for r-process Nucleosynthesis

New measurements of very exotic nuclei in the neutron-rich region beyond N=126 have been performed at the GSI facility with the fragment separator (FRS). The aim of the experiment is to determine half-lives and β-delayed neutron emission branching ratios of isotopes of Hg, Tl and Pb in this region. This contribution summarizes final counting statistics for identification and for implantation, as well as the present status of the data analysis of the half-lives. In summary, isotopes of Pt, Au, Hg, Tl, Pb, Bi, Po, At, Rn and Fr were clearly identified and several of them ({sup 208-211}Hg, {sup 211-215}Tl, {sup 214-218}Pb) were implanted with enough statistics to determine their half-lives. About half of them are expected to be neutron emitters, in such cases it will become possible to obtain the neutron emission probabilities, Pn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements and Simulations of Neutron Emission Versus Deuterium Filling Pressure in Plasma Focus Device PF-24

A series of experiments were carried out using the middle energy (dense) plasma focus device PF-24 with deuterium as a working gas under pressure in a range between 2 and 5 mbar for 17 kV of charging voltage. The relationship between these operating deuterium pressures in reference to the total neutron yield (Y{sub n}) was estimated. The 5-phase Lee code was used to simulate the measured discharge current and neutron yield (Y{sub n}) using a phenomenological beam-target neutron generating mechanism, which was incorporated in the model. Comparison of the Y{sub n} versus pressure using fitted model parameters was made at each point of pressure. The good agreement between measured and computed Y{sub n} values was achieved for discharges with lower neutron emission. The measured Y{sub n} (below 2.6 × 10{sup 9} n/discharge—the median value) has been reproducible by the model for 73% of simulated discharges, while above the median value its prediction were incorrect. The kinetic plasma parameters which were measured and computed using the Lee code for different pressures are: the time to a current sheath collapse (t{sub c}), the average axial current sheath velocity (v{sub z}) and the so called velocity factor (RF). Good agreement was found in the whole range of deuterium pressures between the computed and measured results for these kinematic quantities. Presented findings in this work suggest that the character of neutron emission is more complex than it would seem from classical interpretation of neutron production based on a beam-target model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗