Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

Microscopic entropy of AdS3 black holes revisited

A bstract We revisit the microscopic description of AdS 3 black holes in light of recent progress on their higher dimensional analogues. The grand canonical partition function that follows from the AdS 3 /CFT 2 correspondence describes BPS and nearBPS black hole thermodynamics. We formulate an entropy extremization principle that accounts for both the black hole entropy and a constraint on its charges, in close analogy with asymptotically AdS black holes in higher dimensions. We are led to interpret supersymmetric black holes as ensembles of BPS microstates satisfying a charge constraint that is not respected by individual states. This interpretation provides a microscopic understanding of the hitherto mysterious charge constraints satisfied by all BPS black holes in AdS. We also develop thermodynamics and a nAttractor mechanism of AdS 3 black holes in the nearBPS regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deployment of neural-network-based neutron microscopic cross sections in the Griffin reactor physics application

The capability to utilize neural networks to predict macroscopic and microscopic cross section parametric spaces has been developed for the Griffin reactor physics application. The LibTorch interface enables Griffin's MOOSE-based materials to interact with LibTorch-trained models, allowing for the evaluation of complex macroscopic or microscopic cross section spaces, which are then used to evaluate the neutronic properties of the Griffin finite element model. This study benchmarks traditional ISOXML-formatted tabulation libraries against neural network-based models for 279 nuclides on 20,160 grid points for zero-dimensional and two-dimensional reactor models. Benchmark metrics include the fundamental mode eigenvalue, fission and absorption rates, and various temperature coefficients of reactivity (isothermal, fuel, and moderator). From the perspective of storage space, the complete set of LibTorch models uses 11 MB on disk, compared to the 10 GB for the ISOXML multigroup library that covers the same grid space. For the two-dimensional performance case considered in Griffin, the Torch model uses 97% less RAM than the reference ISOXML dataset while runtime increases by a factor of 3 when using the LibTorch model compared to the ISOXML dataset with multi-linear interpolation. The LibTorch model consistently yields errors within 0.01% for most analyzed quantities except for the temperature coefficients of reactivity where the maximum discrepancies are up to 0.3 $\frac{pcm}{K}$. Due to the neural network attempting to best predict quantities with no regard for a positive or negative bias for any given quantity, predictions may experience random fluctuations, resulting in both positive and negative errors. Future work will entail both depletion and coupled transient analysis to determine the predictive capabilities of Griffin with neural network-based cross sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Macroscopic and microscopic behaviors of Mn(II) (ad)sorption to goethite with the effects of dissolved carbonates under anoxic conditions

Manganese and its compounds have been extensively researched because of their far-reaching roles in a wide range of biogeochemical processes in natural systems. The (ad)sorption behavior of Mn(II), however, is poorly understood despite its important role as the primary reaction step for surface-catalyzed Mn(II) oxidation that is the principal abiotic process forming various Mn (oxyhydr)oxides in nature. Here, we systematically examined Mn(II) (ad)sorption to one of the most common natural sorbents, goethite, in oxygen- and carbonate-free systems. Traditional sorption edge and isotherm experiments were conducted by varying sorbate-to-sorbent ratio (0.027–15 μmol∙m -2 ) and solution pH (pH 5.0–9.0). The effects of dissolved carbonates on Mn(II) sorption were also assessed in a range of naturally prevalent concentrations (0.5–10 mM NaHCO 3 ). The Mn(II) uptake on goethite followed a typical Langmuir isotherm in the absence of dissolved carbonates, with increasing maximum adsorption capacities (Γ max ) from 0.19 at pH 6.5 to 3.4 μmol∙m -2 at pH 9.0. The presence of dissolved carbonates raised the extent of Mn(II) adsorption, which appeared to be directly correspondent to that of the adsorption of dissolved carbonates. Extended X-ray absorption fine structure (EXAFS) analysis indicated that Mn(II) predominantly formed inner-sphere binuclear bidentate surface complexes. Mn(II) uptake became deviated from the Langmuir model and showed a clear indication of surface precipitation when the Mn(II) sorption density (Γ) exceeded a threshold value in a given solution composition. This secondary Mn(II) phase was identified as rhodochrosite using X-ray diffraction (XRD) and transmission electron microscope (TEM). Furthermore, it would be plausible that a minor fraction of adsorbed Mn(II) coexisted with the secondary rhodochrosite according to a linear combination fitting (LCF) of the X-ray absorption near edge structure (XANES) spectra of Mn reference and samples. These systematic investigations of the macroscopic and microscopic behaviors of Mn(II) (ad)sorption to goethite provide a critical avenue for disentangling surface-catalytic Mn(II) oxidation processes, which ultimately lead to the formation of diverse Mn (oxyhydr)oxides in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscopic ejecta measurements from hypervelocity impacts on aluminum and powdered regolith targets

Meteoroids and space debris pose a two-fold threat to spacecraft due to the risk of both mechanical damage from the impact and electrical damage from the impact-generated plasma, which produces electromagnetic emissions. Analysis of impact products, however, has the potential to provide useful information about planetary rings and small solar system bodies, such as asteroids and comets. Understanding the plasma dynamics and radiation mechanism is essential to addressing the impact threat and extracting science data from impacts. Charge attachment to condensed-phase debris may lead to a dusty plasma under certain conditions, so interpreting hypervelocity impacts requires knowledge of both the nature of the plasma and of the ejecta. We address the latter with measurements of the microscopic ejecta distribution produced by light gas gun impacts on solid aluminum and powdered regolith simulant targets. We examine both the size and shape of the ejecta using thin-film witness plates and find that the size distributions of microscopic ejecta follow power laws. Observations from the powdered regolith simulant match well with disruption experiments of solid basalt, while measurements from the aluminum impacts diverge from extrapolations based on studies of macroscopic debris. Analysis of the ejecta shape shows a transition from smooth to irregularly shaped ejecta at the material grain size, and the shape of debris may provide insight on the phase of the ejected material. Finally, based on our results, we predict a significant number of secondary impacts on plasma sensors due to ejecta, even at considerable distance from the target, supporting the hypothesis that charged dust affects plasma measurements in the ejecta curtain.

42 ENGINEERING↗

Design of a neutron microscope based on Wolter mirrors

The predominant geometry for a neutron imaging experiment is that of a pinhole camera. Here, this is primarily due to the difficulty in focusing neutrons due to the weak refractive index, which is also strongly chromatic. Proof of concept experiments demonstrated that neutron image forming lenses based on reflective Wolter mirrors can produce quantitative, high spatial resolution neutron images while also increasing the time resolution compared to the conventional pinhole camera geometry. Motivated by these results, we report the design of a neutron microscope where two Wolter mirrors replace condensing and objective lenses, in direct analogy with typical visible light microscopes. Ray tracing results indicate that this system will yield 3 µm spatial resolution images with an acquisition time of order <1 s (10 4 faster than currently possible at this spatial resolution) with a field of view of about 5 mm in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an in situ ion irradiation scanning electron microscope

An in situ ion irradiation scanning electron microscope (I 3 SEM) has been developed, installed, and integrated into the Ion Beam Laboratory at Sandia National Laboratories. The I 3 SEM facility combines a field emission, variable pressure, scanning electron microscope, a 6 MV tandem accelerator, high flux low energy ion source, an 808 nm-wavelength laser, and multiple stages to control the thermal and mechanical state of the sample observed. The facility advances real-time understanding of materials evolution under combined environments at the mesoscale. As highlighted in multiple examples, this unique combination of tools is optimized for studying mesoscale material response in overlapping extreme environments, allowing for simultaneous ion irradiation, implantation, laser bombardment, conductive heating, cooling, and mechanical deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrolyte-Dependent, “Microscopically Irreversible” H-Atom Transfer Kinetics of Ce-Based Metal–Organic Framework, Ce-MOF-808

Redox reactions at the interface of metal oxides and protic electrolytes almost always involve protons and electrons in equal amounts. Given the stoichiometry, these proton-coupled electron transfer (PCET) reactions are thermochemically equivalent to net H-atom transfer (HAT) reactions. The correlation between the chemical nature of solid catalysts and HAT kinetics has been employed for decades as the design principle for energy-relevant reactions (e.g., reactions of 2H + /H 2 ). More recently, chemists have experimentally determined that a change in liquid electrolytes that alters the microenvironment at the redox-active sites has an equally profound impact on electrocatalysis involving PCET/HAT. Yet, precise correlations between the chemical nature of electrolytes and the PCET kinetics are, to date, rare in the literature. Herein, we report our findings using the Ce-based metal−organic framework, Ce-MOF-808, as a model system. Each Ce 6 (μ 3 −O) 4 (μ 3 − OH) 4 (OH) 6 (H 2 O) 6 node of this MOF undergoes a 1H + /1e − redox reaction. Using chronoamperometry and the Cottrell analysis, we have determined that the PCET hopping kinetics within the pores of Ce-MOF-808 can change by orders of magnitude by altering the buffer species and the proton activity of the electrolyte. Furthermore, in all buffers, reductive reactions were ∼3−10 times faster in kinetics than the reverse oxidative reaction with the same electrochemical driving force, suggesting that the system, at first glance, violates the principle of microscopic reversibility. Isothermal titration calorimetry (ITC) and computational simulations corroborated that the buffer-node binding thermodynamics are quite distinct, depending on the chemical nature of the buffer and the oxidation state of the node. Together, these results suggest that the substrate and the product during the oxidative vs reductive reaction of Ce-MOF-808 are chemically different species, which explains the apparent ‘microscopic irreversibility.’ Thus, the rational modulation of electrolytes can dramatically enhance PCET kinetics, even though the solid electrodes remain identical. Implications of these findings are contrasted with the electrochemical/electrocatalytic behavior of other redox-active MOFs, heterogeneous catalysts, and enzymatic systems at the solid−liquid interface.

Ce-based MOF↗

Machine learning the microscopic form of nematic order in twisted double-bilayer graphene

Modern scanning probe techniques, such as scanning tunneling microscopy, provide access to a large amount of data encoding the underlying physics of quantum matter. In this work, we show how convolutional neural networks can be used to learn effective theoretical models from scanning tunneling microscopy data on correlated moiré superlattices. Moiré systems are particularly well suited for this task as their increased lattice constant provides access to intra-unit-cell physics, while their tunability allows for the collection of high-dimensional data sets from a single sample. Using electronic nematic order in twisted double-bilayer graphene as an example, we show that incorporating correlations between the local density of states at different energies allows convolutional neural networks not only to learn the microscopic nematic order parameter, but also to distinguish it from heterostrain. These results demonstrate that neural networks are a powerful method for investigating the microscopic details of correlated phenomena in moiré systems and beyond.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microscopic theory, analysis, and interpretation of conductance histograms in molecular junctions

Molecular electronics break-junction experiments are widely used to investigate fundamental physics and chemistry at the nanoscale. Reproducibility in these experiments relies on measuring conductance on thousands of freshly formed molecular junctions, yielding a broad histogram of conductance events. Experiments typically focus on the most probable conductance, while the information content of the conductance histogram has remained unclear. Here we develop a microscopic theory for the conductance histogram by merging the theory of force-spectroscopy with molecular conductance. The procedure yields analytical equations that accurately fit the conductance histogram of a wide range of molecular junctions and augments the information content that can be extracted from them. Our formulation captures contributions to the conductance dispersion due to conductance changes during the mechanical elongation inherent to the experiments. In turn, the histogram shape is determined by the non-equilibrium stochastic features of junction rupture and formation. The microscopic parameters in the theory capture the junction’s electromechanical properties and can be isolated from separate conductance and rupture force (or junction-lifetime) measurements. The predicted behavior can be used to test the range of validity of the theory, understand the conductance histograms, design molecular junction experiments with enhanced resolution and molecular devices with more reproducible conductance properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlating activities and defects in (photo)electrocatalysts using in-situ multi-modal microscopic imaging

Photo(electro)catalysts use sunlight to drive chemical reactions such as water splitting. A major factor limiting photocatalyst development is physicochemical heterogeneity which leads to spatially dependent reactivity. To link structure and function in such systems, simultaneous probing of the electrochemical environment at microscopic length scales and a broad range of timescales (ns to s) is required. Here, we address this challenge by developing and applying in- situ (optical) microscopies to map and correlate local electrochemical activity, with hole lifetimes, oxygen vacancy concentrations and photoelectrode crystal structure. Using this multi-modal approach, we study prototypical hematite (α-Fe 2 O 3 ) photoelectrodes. We demonstrate that regions of α-Fe 2 O 3 , adjacent to microstructural cracks have a better photoelectrochemical response and reduced back electron recombination due to an optimal oxygen vacancy concentration, with the film thickness and extended light exposure also influencing local activity. Our work highlights the importance of microscopic mapping to understand activity, in even seemingly homogeneous photoelectrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extreme ultraviolet microscope characterization using photomask surface roughness

We demonstrate a method for characterizing the field-dependent aberrations of a full-field synchrotron-based extreme ultraviolet microscope. The statistical uniformity of the inherent, atomic-scale roughness of readily-available photomask blanks enables a self-calibrating computational procedure using images acquired under standard operation. We characterize the aberrations across a 30-um field-of-view, demonstrating a minimum aberration magnitude of smaller than λ/21 rms averaged over the center 5-um area, with a measurement accuracy better than λ/180 rms. The measured field variation of aberrations is consistent with system geometry and agrees with prior characterizations of the same system. In certain cases, it may be possible to additionally recover the illumination wavefront from the same images. Our method is general and is easily applied to coherent imaging systems with steerable illumination without requiring invasive hardware or custom test objects; hence, it provides substantial benefits when characterizing microscopes and high-resolution imaging systems in situ.

47 OTHER INSTRUMENTATION↗

Reducing experimental uncertainty in the calculation of cavity swelling in a transmission electron microscope through crystallographically aided void volume tracking

Accurate measurement of cavity swelling in a transmission electron microscope is essential to define material performance under irradiation, and the conventionally applied spherical assumption for the calculation of cavity volumes in irradiated materials can result in errors ranging between a 25% underestimation and 72% overestimation of volume purely based on the assumption of shape. This assumption is undeniably expedient for calculation but does not sufficiently account for the 3D nature of polyhedral cavities and their shape projection in the transmission electron microscope, and therefore presents too large of an associated uncertainty in swelling determination for faceted cavities. This uncertainty has been defined for many common cavity shapes in FCC and BCC crystal systems, and has been tabulated across the cubic fundamental region. A revised methodology for crystallographically aided void volume tracking, or CAVV-T, is presented and demonstrated on a specimen of neutron irradiated Ni. In-depth discussion on the application of this technique is provided along with resources to allow for conversion between the spherical assumption and this revised method. This work seeks to increase experimental confidence in the characterization and quantification of critical aspects of irradiation damage in materials by applying a crystallographically-resolved approach for cavity swelling calculation.

Haag IV, James V. [Pacific Northwest National Labo↗

Laser-free GHz stroboscopic transmission electron microscope: Components, system integration, and practical considerations for pump–probe measurements

In this work a 300 keV transmission electron microscope was modified to produce broadband pulsed beams that can be, in principle, between 40 MHz and 12 GHz, corresponding to temporal resolution in the nanosecond to picosecond range without an excitation laser. The key enabling technology is a pair of phase-matched modulating and de-modulating traveling wave metallic comb striplines (pulsers). An initial temporal resolution of 30 ps was achieved with a strobe frequency of 6.0 GHz. The placement of the pulsers, mounted immediately below the gun, allows for preservation of all optical configurations, otherwise available to the unmodified instrument, and therefore makes such a post-modified instrument for dual-use, i.e., both pulsed-beam mode (i.e., stroboscopic time-resolved) and conventional continuous waveform mode. In this article, we describe the elements inserted into the beam path, challenges encountered during integration with an in-service microscope, and early results from an electric-field-driven pump–probe experiment. We conclude with ideas for making this class of instruments broadly applicable for examining cyclical and repeatable phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reconstruction and uncertainty quantification of lattice Hamiltonian model parameters from observations of microscopic degrees of freedom

The emergence of scanning probe and electron beam imaging techniques has allowed quantitative studies of atomic structure and minute details of electronic and vibrational structure on the level of individual atomic units. These microscopic descriptors, in turn, can be associated with local symmetry breaking phenomena, representing the stochastic manifestation of the underpinning generative physical model. In this work, we explore the reconstruction of exchange integrals in the Hamiltonian for a lattice model with two competing interactions from observations of microscopic degrees of freedom and establish the uncertainties and reliability of such analysis in a broad parameter-temperature space. In contrast to other approaches, we specifically specify a loss function inherent to thermodynamic systems and utilize it to estimate uncertainty in simulated realizations of different models. As an ancillary task, we develop a machine learning approach based on histogram clustering to predict phase diagrams efficiently using a reduced descriptor space. We further demonstrate that reconstruction is possible well above the phase transition and in the regions of parameter space when the macroscopic ground state of the system is poorly defined due to frustrated interactions. This suggests that this approach can be applied to the traditionally complex problems of condensed matter physics such as ferroelectric relaxors and morphotropic phase boundary systems, spin and cluster glasses, and quantum systems once the local descriptors linked to the relevant physical behaviors are known.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward the fabrication of a 5- μm -resolution Wolter microscope for the National Ignition Facility (invited)

Advancements in computer-controlled polishing, metrology, and replication have led to an x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. Here, we present the fabrication and test of a nickel–cobalt replicated full-shell x-ray mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed for an 8-m source-to-detector-distance microscope, with 10× magnification, and was optimized to reduce shell distortions that occur within 20 mm of the shell ends. This, in combination with an improved replication tooling design and refined bath parameters informed by a detailed COMSOL Multiphysics® model, has led to reductions in replication errors in the mirrors. Mandrel surface fabrication was improved by implementing a computer-controlled polishing process that corrected the low-frequency mandrel figure error and achieved <2.0 nm RMS convergence error. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated <10 μm full-width at half-maximum (FWHM) spatial resolution. Here, we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving a program goal of 5 μm FWHM resolution.

47 OTHER INSTRUMENTATION↗

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.

36 MATERIALS SCIENCE↗