Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microparticles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

41 records · Page 3

Osmotic and phoretic competition explains chemotaxic assembly and sorting

Microscale objects responding to chemical gradients by migrating toward or away from a preferred species is a simple yet constitutive mechanism by which transport occurs in biological organisms. Synthetic chemotaxis provides key physical descriptions of simplified systems that can be used in biological models, or in the creation of advanced responsive material systems. In this article, we provide a quantitative framework for understanding synthetic chemotaxis of microparticles which involves a competition between phoresis and osmosis. We present separate quantitative measurements of phoresis and osmosis acting on individual taxing particles, finding that phoresis follows the long-predicted v ∼ 1 / r 2 scaling while the osmotic contribution depends on the geometry and details of the system, and must be solved on a case-by-case basis. Through this, we are able to develop a more accurate picture of particle transport at the single particle level. Equipped with this approach, we go on to describe how high concentrations of particles in a symmetric chemical gradient grow close-packed hives that reach a steady-state size tunable through light intensity or particle size. Last, we demonstrate that mixed particles experiencing the same chemical gradient will selectively migrate toward or away depending on the nature of the particle surface, thereby locally sorting out a particular species. We anticipate these results will be important in describing both biological and synthetic chemotaxis in phoretic systems and should bring a wealth of studies that take advantage of competing osmotic flows to illicit unexpected dynamic active behavior.

Science & Technology - Other Topics↗

Collective behavior of “flexicles”

In recent years the functionality of synthetic active microparticles has edged even closer to that of their biological counterparts. However, we still lack the understanding needed to recreate at the microscale key features of autonomous behavior exhibited by microorganisms or swarms of macroscopic robots. In this study, we propose a model for a three-dimensional deformable cellular composite particle consisting of self-propelled rod-shaped colloids confined within a flexible vesicle—representing a superstructure we call a “flexicle” that couples particle deformation to the internal dynamics of the internal active components. Using molecular dynamics simulations, we investigate the collective behavior of dense systems composed of many flexicles. We show that individual flexicles exhibit shape changes upon collisions with other flexicles that lead to rearrangements of the internal active rods, which slows flexicle motion. This shape deformability gives rise to a diverse set of motility-induced phase separation phenomena and the spontaneous flow of flexicles reminiscent of the migration of cells in dense tissues. Our findings establish a foundation for designing responsive, cell-like active particles and developing strategies for controlling swarm migration and other autonomous swarm behaviors at cellular and colloidal scales.

Science & Technology - Other Topics↗

Quadrilateral particle arrangement within shocks in a two-dimensional dusty plasma

The microscopic structure within a two-dimensional shock was studied using data from a dusty plasma experiment. A single layer of charged microparticles, levitated in a glow-discharge plasma, was perturbed by an electrically floating wire that was moved at a steady supersonic speed to excite a compressional shock. A rearrangement of particles was observed, from a hexagonal lattice in the preshock into a quadrilateral microstructure on the front side of the shock. This quadrilateral structure would not be stable in a monolayer of identical repulsive particles, under equilibrium conditions. Glaser-Clark polygon analysis of the microstructure helped in identifying quadrilaterals. Voronoi analysis was used to characterize the defect fraction behind the shock, as an indication of shock-induced melting. Published by the American Physical Society 2025

Kananovich, Anton (ORCID:0000000225374952)↗

Moving toward automated µFTIR spectra matching for microplastic identification: addressing false identifications and improving accuracy

Abstract Infrared spectroscopy is a widely used tool for studying microplastics and identifying microparticles. Researchers rely on spectral libraries to differentiate between synthetic and natural materials. Unfortunately, spectral library matching is not perfect, and best practices require researchers to use time consuming, manual peak matching to assess spectral matches. Moving toward automated matching requires increased confidence in the matching process. Using spectra matching software may increase the efficiency of particle identification, however some matching strategies may confuse natural materials such as cotton, silk, and plant matter with common classes of synthetics such as polyesters and polyamides. In this experiment, we prepared 22 pristine sample materials from natural and synthetic sources and measured micro-Fourier transform infrared (µFTIR) spectra in transmission mode for each sample using a Thermo Nicolet iN10 MX instrument. The collected spectra were then input into two spectral library matching systems (Omnic Picta and Open Specy), using a total of five identification routines. Next, we placed a subset of four pristine microplastic materials in a biologically active river system for two weeks to simulate environmental samples. These simulated environmental samples were processed using 10% hydrogen peroxide for 24 h to remove organic contamination and then identified using the strongest performing library. We found that libraries with fewer sample spectra produced lower correlation matches and that using derivative correction greatly reduced the number of inaccuracies in identifying materials as either natural or synthetic. We also found that environmental fouling reduced the correlation value of library matches when compared to pristine particles, however the effect was not consistent across the four materials tested. Overall, we found that the accuracy of automated library matching in the tested systems and processing routines varied from 64.1 to 98.0% for distinguishing between natural and synthetic materials, and that a high Hit Quality Index (HQI) did not always correlate with accuracy. These results are important for the microplastic field, demonstrating a need to rigorously test spectral libraries and processing routines with known materials to ensure identification accuracy.

Kozloski, Rachel↗

Trace Element Analyses of Micron-Size Particles and Statistical Determination of Minimum Detection Limits

Savannah River National Laboratory (SRNL) has developed expertise in producing homogeneous, ca. 1 m-diameter spherical particles of mixed-element components, wherein dopants can be varied from a trace constituent (ppm) to wt.% concentrations. The samples used for this work are nickel-doped cerium oxide microspheres produced by SRNL. They were initially selected as analogs for plutonium-doped uranium oxide particles and analyzed as part of a larger study to evaluate whether electron probe microanalyzers (EPMA) can be used to characterize nuclear materials as an alternative or complementary method to mass spectrometers. The five samples used in this study contained nominal compositions of 0, 0.004, 0.04, 0.4 and 4 wt.% Ni. They were analyzed by both an Agilent 7900 Q-ICP-MS at SRNL and the JEOL JXA8530F Plus EPMA at the University of Minnesota. In addition to EPMA results (calibrated with high-precision Q-ICP-MS analyses) suggesting that the EPMA could address outstanding nuclear material characterization needs, these samples 1) showcase the ability of the EPMA to quantify not just trace concentrations, but trace concentrations in microparticles (1 m diameter, Fig. 1), and 2) offer a unique opportunity to evaluate the methodology for assessing the minimum detection limits of EPMA analyses.

McSwiggen, Peter [JEOL USA, 11 Dearborn Road, Peab↗