Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microchannel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dynamically morphing microchannels in liquid crystal elastomer coatings containing disclinations

Liquid crystal elastomers (LCEs) hold a major promise as a versatile material platform for smart soft coatings, since their orientational order can be predesigned to program a desired dynamic profile. In this work, we introduce temperature-responsive dynamic coatings based on LCEs with arrays of singular defects-disclinations that run parallel to the surface. The disclinations form in response to antagonistic patterns of the molecular orientation at the top and bottom surfaces, imposed by the plasmonic mask photoalignment. Upon heating, an initially flat LCE coating develops linear microchannels located above each disclination. The stimulus that causes a non-flat profile of LCE coatings upon heating is the activation force induced by the gradients of molecular orientation around disclinations. To describe the formation of microchannels and their thermal response, we adopt a Frank-Oseen model of disclinations in patterned director field and propose a linear elasticity theory to connect the complex spatially-varying molecular orientation to the displacements of the LCE. The thermo-responsive surface profiles predicted by the theory and by the finite element modeling are in good agreement with the experimental data; in particular, higher gradients of molecular orientation produce a stronger modulation of the coating profile. The elastic theory and the finite element simulations allow us to estimate the material parameter that characterizes the elastomer coating’s response to the thermal activation. The disclinations containing LCEs show potential as soft dynamic coatings with a predesigned responsive surface profile.

36 MATERIALS SCIENCE↗

Performance of microchannel plate based detectors for <25 keV x rays: Monte Carlo simulations and comparisons with experimental results

We present the results of Monte Carlo simulations of the microchannel plate (MCP) response to x rays in the 250 eV to 25 keV energy range as a function of both x-ray energy and impact angle and their comparisons with the experimental results from the X8A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. Incoming x rays interact with the lead glass of the microchannel plate, producing photoelectrons. Transport of the photoelectrons is neglected in this model, and it is assumed that photoelectrons deposit all their energy at the point they are created. This deposition leads to the generation of many secondary electrons, some fraction of which diffuse to the MCP pore surface where they can initiate secondary electron cascades in the pore under an external voltage bias. X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV, and the effect of this penetration on MCP performance is studied. In agreement with past measurements, we find that the dependence of MCP sensitivity with angle relative to the pore bias changes from a cotangent dependence to angular independence and then proceeds to a secant dependence as the x-ray energy increases. We also find that with the increasing x-ray energy, the MCP gain sensitivity as a function of bias voltage decreases. The simulations also demonstrate that for x rays incident normal to the MCP surface, spatial resolution shows little dependence on the x-ray energy but degrades with the increasing x-ray energy as the angle of incidence relative to the surface normal increases. This agrees with experimental measurements. Simulation studies have also been completed for MCPs gated with a subnanosecond voltage pulse. In this work, we find that the optical gate profile width increases as the x-ray energy is increased above 5 keV, a consequence of increased x-ray penetration at energies >5 keV. Simulations of the pulsed dynamic range show that the dynamic range varies between ~100 and 1000 depending on x-ray energy and peak voltage.

47 OTHER INSTRUMENTATION↗

Spatio-temporal electric field distributions in an atmospheric plasma jet impinging on a microchannel array surface

The electric field distribution in the ionization waves (IWs) propagating over a microchannel array dielectric surface, with the channels either empty or filled with distilled water, is measured by ps electric field induced second harmonic generation. The surface IW is initiated by the atmospheric pressure N 2 –Ar plasma jet impinging on the surface vertically and powered by ns pulse discharge bursts. The results show that the electric field inside the microchannels, specifically its horizontal component, is enhanced by up to a factor of 2. The field enhancement region is localized within the channels. The vertical electric field inside the channels lags in time compared to the field measured at the ridges, indicating the transient reversal of the IW propagation direction across the channels (toward the jet). This is consistent with the phase-locked plasma emission images and confirmed by the kinetic modeling predictions, which show that the IW ‘jumps’ over the empty channels and propagates into the channels only after the jump between the adjacent ridges. When the channels are filled with water, the wave speed increases by up to 50%, due to the higher effective dielectric constant of the surface. No evidence of a significant electric field enhancement near the dielectric surface (ceramic or water) has been detected, within the spatial resolution of the present diagnostic, ~100 μ m.

plasmas and liquids↗

SiC Microchannel Heat Sinks for High Heat Flux Dissipation of 1 kW/cm 2

Thermal management has become a major barrier in the development of high-power micro-devices. Microchannel heat sinks (MCHS) are a promising method to dissipate high heat fluxes from high power density devices. Reducing the thermal resistance will reduce the temperature increase of the electronic device, allowing for higher powers to be achieved while maintaining a safe operating temperature. This paper reports on the use of silicon carbide (Sic) microchannels to dissipate high heat fluxes up to 1 kW/cm 2 over a footprint of 0.25 cm 2 . The use of high aspect ratio and decreased hydraulic diameter channels has allowed for very low thermal resistances to be achieved at higher heat duties compared to previous studies. The experiments performed resulted in heater temperatures of less than 60 °C and thermal resistances as low as 0.024 cm 2 . ° $C$/W between the heater surface and fluid inlet temperature. In conclusion, the demonstrated thermal performance of the SiC MCHS is an encouraging means for dissipating heat from high power density microelectronic devices.

42 ENGINEERING↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Slip velocity boundary conditions for the lattice Boltzmann modeling of microchannel flows

Abstract Slip flows in ducts are important in numerous engineering applications, most notably in microchannel flows. Compared to the standard no‐slip Dirichlet condition, the case of slip formulates as a Robin‐type condition for the fluid tangential velocity. Such an increase in mathematical complexity is accompanied by a more challenging numerical transcription. The present work concerns with this topic, addressing the modeling of the slip velocity boundary condition in the lattice Boltzmann method (LBM) applied to steady slow viscous flows inside ducts of nontrivial shapes. As novelty, we extend the newly revised local second‐order boundary (LSOB) Dirichlet fluid flow method [ Philos. Trans. R. Soc. A 378, 20190404 (2020)] to implement the slip velocity condition within the two‐relaxation‐time (TRT) framework. The LSOB follows an in‐node philosophy where its operation principle seeks to explicitly reconstruct the unknown boundary populations in the form of a third‐order accurate Chapman–Enskog expansion, where the wall slip condition is built‐in as a normal Taylor‐type condition. The key point of this approach is that the required first‐ and second‐order momentum derivatives, rather than computed through nonlocal finite difference approximations, are locally determined through a simple local linear algebra procedure, whose formulation is particularly aided by the TRT symmetry argument. To express the obtained derivatives, two approaches are considered, called and , which operate with node and wall variables, respectively. These two formulations are developed to prescribe the physical slip condition over plane and curved walls, including the corners. Their consistency and accuracy characteristics are examined against alternative linkwise strategies to impose the wall slip velocity, such as the kinetic‐based diffusive bounce‐back scheme, the central linear interpolation slip scheme, and the multireflection slip scheme. The several slip schemes are tested over different 3D microchannel configurations, with walls not conforming with the LBM uniform mesh. Numerical tests confirm the advanced accuracy characteristics of the proposed LSOB slip boundary scheme, revealing the added challenge of the wall slip modeling, and that parabolic accuracy is a necessary requirement to reach second‐order accuracy within this problem class.

Silva, Goncalo↗

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

Using Membranes with Internal Microchannels to Prevent Drying-out during CO 2 Electrolysis

Scaling up CO 2 electrolysis is a vital aspect in the transition to manufacturing sustainable fuels and chemical compounds, satisfying the demand for chemicals and demand for storing renewable electricity. Depending on the employed catalyst, different products can be produced, such as carbon monoxide and ethylene, by applying a voltage on a CO 2 and H 2 O fed electrolyzer. CO is a desirable product according to techno-economic analysis, because it can be produced selectively using a silver catalyst and is a precursor for hydrocarbons in the Fischer–Tropsch process. In a state-of-the-art CO 2 electrolyzer, two electrodes are directly pressed against an ion-exchange membrane – this is called a zero-gap configuration. Therefore, the membrane is a crucial component for the system, since it has the role of providing a conductive medium between the electrodes. One of the challenges in CO 2 electrolysis is that water is consumed in the reaction. At high current density, this may cause the membrane's surface near the cathode to dry out, lowering efficiency or perhaps stopping the process entirely, since there is no longer a conductive medium. As a result, water management is critical for this process. In this work, we approach the drying-out challenge by studying the novel concept of a membrane with internal microchannels. These channels allow the circulation of water or an electrolyte inside the membrane, which reduces the water diffusion path and affects the membrane’s conductivity. The effects of channel geometry, location, and concentrations of electrolyte inside on water content, conductivity and overall performance are studied in a 2D COMSOL model. In addition, the effect of internal concentration of electrolyte on the membrane’s resistance, on the process performance and the K + cross-over to cathode side were investigated experimentally. Our modeling results prove that the presence of the channels can keep the membrane hydrated. The highest current densities are observed when the channel is closest to the cathode, and with smaller pores. Smaller pores are advantageous due to the trade-off between enhanced membrane conductivity and the lower conductivity of the liquid itself. If water is circulated in a large channel, it increases the membrane’s ionomer conductivity due to hydration but the overall conductivity is decreased since water is not highly conductive. Nonetheless, the results also show that a higher concentration of electrolyte inside the microchannels can significantly increase the total conductivity of the membrane, and therefore the energy efficiency of the process. These effects are most significant at higher current densities. In the experimental results, we’ve observed similar effects in terms of membrane conductivity and current density of the process – the higher the electrolyte concentration the higher the current density. Furthermore, a low concentration decreases the amount of potassium which crosses over to the cathode side, inhibiting salt deposition. We’ve concluded that a small channel, up to 90 µm wide, close to the pore with an electrolyte with a concentration of up to 10 mM could be very beneficial for the water management and energy efficiency of the process. This helps to keep the membrane hydrated at higher current densities, improves the conductivity of the membrane, and it doesn’t have significant impacts on the salt deposition.

Petrov, Kostadin Veselinov↗

Joule-class THz pulses from microchannel targets

Inference of joule-class THz radiation sources from microchannel targets driven with hundreds of joule, picosecond lasers is reported. Here, THz sources of this magnitude are useful for nonlinear pumping of matter and for charged-particle acceleration and manipulation. Microchannel targets demonstrate increased laser–THz conversion efficiency compared to planar foil targets, with laser energy to THz energy conversion up to ~0.9% in the best cases.

47 OTHER INSTRUMENTATION↗

Progress Report on Model Development for the Transport of Aerosol Through Microchannels

Accuracy of consequence assessments could be improved by accounting for the leak path deposition of aerosol in the source term. Recent experimental measurements from Sandia (2018) provided evidence of partial microchannel plugging due to particulate deposition. This filtration effect is relevant to the source term assessments and it is not unreasonable to anticipate that aerosol deposition in more realistic geometries could even lead to complete plugging of the leak path. This report summarizes current progress (as of end of Q3 FY 2020) on the development of a phenomenological model of aerosol transport, deposition, and plugging through microchannels. The purpose is to introduce a generic, reliable numerical model for the prediction of aerosol transport, deposition, and plugging in leak paths while accounting for potential plugging formation. This report includes (1) an overview of recent additions and improvements on the recently developed numerical model to analyze the various deposition processes in leak paths, to provide quantitative estimates of penetration factors, and to gain an understanding of the variables that affect them and (2) a summary of recent benchmarking results of the model’s validity with recent experimental measurements from Sandia.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications FY24Q4 (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high-temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary. Our goal is to evaluate heat exchanger lifetime and operational limits for the manufacturing and prototype design for next-generation CSP heat exchanger technology through a combination of collecting experimental data and modeling studies.

14 SOLAR ENERGY↗

Evaluating Microchannel Heat Exchanger Lifetime for Concentrating Solar Power Applications Research Performance Progress Report (RPPR-1)

Microchannel heat exchanger technology is being pursued for next generation CSP concepts for primary power cycle heat addition and power cycle heat recuperation due to the high heat transfer coefficients and pressure containment advantages of small sCO 2 channels. The economics of future CSP plants as dictated by the SETO 2020 or 2030 targets depend on a heat exchanger with a 30-year lifetime (resisting creep, fatigue, corrosion, erosion) and operational characteristics such as fast ramping and the ability to withstand thermal shock. However, the lifetime and operational limits of microchannel heat exchangers operating at high temperatures, particularly those constructed from high-nickel alloys, are not well known. This uncertainty has resulted in heat exchanger vendors not being able to accurately forecast heat exchanger lifetime as required by customers, specify operational limits as required by process engineers to prevent premature heat exchanger failure, or overdesign heat exchanger which leads to higher cost than necessary.

14 SOLAR ENERGY↗

Ultraviolet spectrograph using microchannel plates

An ultraviolet spectrograph was constructed using double microchannel plates as detectors at the focal plane. The photoelectron pulses were located one at a time by measuring the charge division to the ends of a resistor strip behind the microchannel plates. The system worked to 20,000 counts/sec and gave resolution exceeding 100 elements.

Lawrence, G. M.↗

Optimization of the performance of a tandem microchannel plate detector as a function of interplate spacing and voltage

The effect of varying the size of the gap voltage and spacing on the performance of a tandem pair of microchannel plates (MCP) is investigated. Results show that increasing the voltage in the gap increases the gain of the pair and also produces a narrower Gaussian pulse-height distribution, although beyond a critical voltage the gain of the channel plate pair is found to plateau. A model is developed which explains the nonlinear gain behavior of individual microchannels and the behavior of the electron cloud emitted from the first MCP as it spreads out between the two MCPs and hits the surface of the second. The model calculates the plateau voltage as a function of the gap size, the gain of each MCP, and the diameter of the channels, and is found to show good agreement with the observed results. It is concluded that interplate gaps of up to several millimeters can be accommodated without a significant degradation in pulse-height distribution.

Rogers, D.↗

Microchannel intensified electrography

Although electrography is an attractive electronic imaging technique, it suffers at low light levels from limitations imposed by microphotometer and emulsion grain noise. The use of microchannel intensification allows individual photoelectron events to be unambiguously detected and measured, with little loss of achievable resolution. A series of quantitative studies have been conducted to determine the gains in detectivity and SNR yielded by the use of this technique, through microphotometry and computer analysis of images identical or similar to laboratory light sources, by means of both unintensified and microchannel-intensified electromagnetic Schmidt cameras. Applications of the technique to far-UV wide field imaging and nebular spectrograph experiments are described.

Heckathorn, H. M.↗

Electronic readout systems for microchannel plates

The modes of operation of position-sensitive electronic readout systems which use high-gain microchannel plate (MCP) electron multipliers are described, and their performance characteristics, along with those of the MCP, are compared. Among the structures presented are the wedge-and-strip, Codacon, and multilayer coincidence-anode MAMA (Multimode Microchannel Array) arrays. Spatial resolution of 25 x 25 sq microns (coincidence anode arrays) is achieved with an array format of 256 x 1024 pixels. On the basis of the performance data it is concluded that the readout systems using only conducting electrodes offer the best performance characteristics.

Timothy, J. G.↗

A position sensitive microchannel photomultiplier for ultraviolet space astronomy

The 25-mm microchannel-plate, position-sensitive UV astronomy photomultiplier tube presented is intended for the EOM-1 Spacelab Mission's FAUST payload and conducts wide-field imaging surveys in the VUV over the 1400-1800-A range. The sealed detector encompasses a CsI photocathode deposited on the inner surface of a MgF2 window, a stack of microchannel plates, and a wedge-and-strip two-dimensional position-sensing anode. Since the wedge-and-strip principle requires only three anode signals, flight electronics can be reduced to three charge amplifiers and three analog-to-digital converters.

Lampton, M.↗