Hacking Limnology Workshop and DSOS22: Creating a Community of Practice for the Nexus of Data Science, Open Science, and the Aquatic Sciences

The 2nd Aquatic Ecosystem Modeling-Junior (AEMON-J) Hacking Limnology Workshop and 3rd Virtual Summit: Incorporating Data Science and Open Science in the Aquatic Sciences (DSOS) took place on 25–29 July 2022. These virtual events were developed to bring together researchers from diverse backgrounds to share developments in data-intensive research in the aquatic sciences and train participants in cutting-edge data analysis methods related to remote sensing, data pipelines, and modeling of aquatic ecosystems.

54 ENVIRONMENTAL SCIENCES↗

From Theory to Practice: Lessons Learned from an Advanced M&V Commercial Pilot

Advanced measurement & verification (M&V), or M&V 2.0, is an energy data analysis method using advanced metering infrastructure (AMI) data in combination with analytics to quantify energy efficiency project savings. Advanced M&V is viewed as an enabler for underutilized behavioral, retrocommissioning, and holistic multi-measure efficiency efforts, as quantifying savings for these programs with existing methods has typically been very challenging. Despite its promise, there are still several unanswered questions about the use of advanced M&V such as: How accurately can these tools quantify energy savings? How can advanced M&V satisfy regulatory requirements for rigorous savings estimates? Where and how does advanced M&V intersect with traditional impact evaluation and the principles of ‘embedded’ evaluation, measurement & verification (EM&V)? Pilots are being pursued in various regions and program contexts to address these research questions. However, results from these pilots are rarely made public, meaning that lessons may not be widely shared and the scope of analyses varies widely. The paper presents encouraging results from a recent advanced M&V pilot and discusses key process-related aspects such as managing AMI data and refining analysis methodologies. An approach to reviewing and classifying projects based on savings characteristics and magnitude is demonstrated, as a potential risk management tool. The authors also demonstrate how advanced M&V can identify underperforming projects and non-routine events in a timely manner. The paper also outlines lessons learned from this and other recent pilot activity and barriers to be overcome in moving toward the goal of widespread adoption of holistic meter-based programs.

Crowe, Eliot↗

The AMIDAS Website: An Online Tool for Direct Dark Matter Detection Experiments

Following our long-erm work on development of model-independent data analysis methods for reconstructing the one-dimensional velocity distribution function of halo WIMPs as well as for determining their mass and couplings on nucleons by using data from direct Dark Matter detection experiments directly, we combined the simulation programs to a compact system: AMIDAS (A Model-Independent Data Analysis System). For users' convenience an online system has also been established at the same time. AMIDAS has the ability to do full Monte Carlo simulations, faster theoretical estimations, as well as to analyze (real) data sets recorded in direct detection experiments without modifying the source code. In this article, I give an overview of functions of the AMIDAS code based on the use of its website.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sample manipulation and data assembly for robust microcrystal synchrotron crystallography

With the recent developments in microcrystal handling, synchrotron microdiffraction beamline instrumentation and data analysis, microcrystal crystallography with crystal sizes of less than 10 µm is appealing at synchrotrons. However, challenges remain in sample manipulation and data assembly for robust microcrystal synchrotron crystallography. Here, the development of micro-sized polyimide well-mounts for the manipulation of microcrystals of a few micrometres in size and the implementation of a robust data-analysis method for the assembly of rotational microdiffraction data sets from many microcrystals are described. The method demonstrates that microcrystals may be routinely utilized for the acquisition and assembly of complete data sets from synchrotron microdiffraction beamlines.

59 BASIC BIOLOGICAL SCIENCES↗

New MOF based on lithium tetrahydrofuran-2,3,4,5-tetracarboxylate: Its structure and conductivity behavior

A novel metal–organic framework, [Li{sub 6}(HTFTA){sub 2}(H{sub 2}O){sub 3}]·3H{sub 2}O (LiTFTA, H{sub 4}TFTA is tetrahydrofuran-2,3,4,5-tetracarboxylic acid), has been synthesized under solvothermal conditions and its structure was determined by single-crystal X-ray diffraction studies. It has six different LiO{sub 4} tetrahedra which forms two kinds of tetranuclear clusters that are coordinated to the ligands and form an overall three-dimensional structure with channels running along the crystallographic a axis. Some of the carboxylate groups of the ligand moiety jut out into the channels and the channels are occupied by water molecules. The proton conductivity behavior of LiTFTA with respect to temperature and relative humidity was analyzed by our newly developed impedance data analysis method called a random-walk approach. The results were compared with the data obtained by an analysis using an equivalent electric circuit model. Based on the physical parameters obtained by the random-walk method and the known structure we suggested the mechanism of the proton conductivity in this material. The proton conduction proceeds most probably by a vehicle conduction mechanism which employs mainly water molecules of crystallization present in the channels of LiTFTA. The value of the diffusion coefficient increases with temperature whereas the number of charge carriers remains constant. On the other hand, both the number of charge carriers and diffusion coefficient increase with increasing relative humidity. - Graphical abstract: Structure of a new metal organic framework was determined and its ionic conductivity was evaluated using a random-walk approach. - Highlights: • Lithium tetrahydrofuran-2,3,4,5-tetracarboxylate is a MOF with water-filled pores. • The impedance spectra indicate that this material is ion conductive. • Conductivity was evaluated using a random walk approach. • The number of charge carriers and diffusion coefficient was determined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

For your consideration: Distance Analysis for PDV Data

An analytical study that discusses photonic Doppler velocimetry data analysis methods. The author intends to share this study with experts in this field at National Laboratory partners, e.g., LLNL, LANL, and Sandia. There is no plan to submit this work to a professional (public) conference or a journal publisher.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mock LISA data challenge for the Galactic white dwarf binaries

We present data analysis methods used in the detection and estimation of parameters of gravitational-wave signals from the white dwarf binaries in the mock LISA data challenge. Our main focus is on the analysis of challenge 3.1, where the gravitational-wave signals from more than 6x10{sup 7} Galactic binaries were added to the simulated Gaussian instrumental noise. The majority of the signals at low frequencies are not resolved individually. The confusion between the signals is strongly reduced at frequencies above 5 mHz. Our basic data analysis procedure is the maximum likelihood detection method. We filter the data through the template bank at the first step of the search, then we refine parameters using the Nelder-Mead algorithm, we remove the strongest signal found and we repeat the procedure. We detect reliably and estimate parameters accurately of more than ten thousand signals from white dwarf binaries.

79 ASTRONOMY AND ASTROPHYSICS↗

Simplified Processing Method for Meter Data Analysis

Simple/Quick metered data processing method that can be used for Army Metered Data Management System (MDMS) and Logistics Innovation Agency data, but may also be useful for other large data sets. Intended for large data sets when analyst has little information about the buildings.

97 MATHEMATICS AND COMPUTING↗

Effectiveness of CID, HCD, and ETD with FT MS/MS for Degradomic-Peptidomic Analysis: Comparison of Peptide Identification Methods

We report on use of an Orbitrap Velos mass spectrometer for comparison of fragmentation methods namely CID-, HCD-, and ETD for FT MS/MS analysis of human blood plasma peptidomic peptides. The peptidomic peptides were able to be identified from CID, HCD, and ETD spectra on specific confidence levels (e.g., 1% false discovery rate) with use of conventional SEQUEST database search software, and the number of identified peptides was increased by ~50% using accurate fragments (e.g., with mass tolerance of 0.05Da) in comparison with traditional moderate accuracy fragments (e.g., with 1 Da mass tolerance) for database search. However, the peptide datasets identified with such decoy search strategy were found to be varied by ~25% in the dataset size and ~20% in the dataset content with type of decoy database and precursor mass tolerances used for database search. CID was evaluated as the largest contributor to the identified peptide datasets, and HCD, and ETD provided ~20% and ~22% respectively additional peptides with accurate fragments for peptide identification, in contrast to ~25% and ~13% respectively with use of moderate accuracy fragments. When long (typically ≥7 amino acids) sequences were used for identification of peptides from the previously published UStags and de novo sequencing methods, HCD was evaluated as the largest contributor, and CID and ETD provided ~26% and ~8% respectively additional peptides from the UStags method and ~26% and ~6% respectively additional peptides from the de novo sequencing method. The peptide datasets identified with the UStags method were little influenced by the decoy database and mass tolerance and 98-99% peptide overlaps could be achieved between these datasets. CID, HCD, and ETD contributed their identifications of various charge state peptides in the m/z range highly overlapped and complementary implementation of CID, HCD, and ETD should be applied to maximize the number of peptides identified. Finally, the investigation presented in this work suggests that selection of fragmentation methods benefits significantly from a careful match with data analysis method applied for identification of peptides and the analysis throughput desired for various purposes of peptidomic-degradomic analysis.

59 BASIC BIOLOGICAL SCIENCES↗

A dark matter search using the final CDMS-II data and 100 mm SuperCDMS germanium detector ionization test

Astrophysical observations indicate that approximately 85% of the matter in the universe is nonluminous, nonbaryonic, and nonrelativistic (cold) dark matter. Weakly Interacting Massive Particles (WIMPs) are a particularly well motivated dark matter particle candidate. They would be thermally produced in the early universe and their relics account for the current dark matter abundance. WIMP candidate particles are naturally provided by extensions to the Standard Model of particle physics, such as supersymmetry. The Cryogenic Dark Matter Search (CDMS) experiment operates cryogenic germanium and silicon particle detectors in the low-background environment of the Soudan Underground Laboratory in northern Minnesota to search for WIMP-nucleus scatters while rejecting electron-recoil background. The detectors simultaneously measure the ionization and phonon energies of each scattering event. The difference in ionization yield (ratio of ionization energy to recoil energy) discriminates nuclear recoils from the electron-recoil background efficiently.More sensitive detectors are required to probe the WIMP parameter space with lower WIMP-nucleon scattering cross sections. To support the R&D effort especially the detector R&D and characterization of the SuperCDMS experiment, a new CDMS test facility has been developed on the University of Minnesota campus. This thesis documents the test facility and the work involved in its development. In the test facility, we performed the first ionization collection efficiency measurements of the ionization test devices. The test devices are fabricated with detector-grade germanium crystals that are 100 mm in diameter, which is the largest available, and 33 mm in thickness. The measured efficiencies are consistent with the earlier measurements conducted with smaller Ge crystals, demonstrating that these 100 mm crystals can be used for development of the next generation dark matter detectors.Improvements of data analysis methods can also potentially improve the sensitivity of an experiment. The data taken during the last four runs of CDMS II with total raw exposure 612 kg-day were reprocessed with improved ionization pulse reconstruction algorithm. We present the classic timing analysis with the reprocessed data in this thesis. For the four runs combined, this analysis resulted in a new WIMP-nucleon cross section 4.4×10 -44 cm 2 for a WIMP mass of 70 GeV, which is a factor of 1.6 improvement compared to the original c58 classic timing analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (?1 GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a high radiation environment and it has enabled us to achieve the desired precision in the measurement of the electron beam polarization which in turn has allowed the most precise determination of the weak charge of the proton.

43 PARTICLE ACCELERATORS↗

Influence of the line-shape model on the spectroscopic determination of the Boltzmann constant

Recent high-resolution spectroscopic experiments demonstrated the possibility of measuring the Boltzmann constant directly from the Doppler width of atomic or molecular lines; however, both experimental setups and data analysis methods still need to be improved to compete with the best acoustic methods. In this paper, the influence of choice of spectral line-shape model for data analysis on systematical error of the Doppler-width determination is analyzed on the example of the oxygen line near {lambda}=687 nm. Profile simulations were performed for many different models at pressures ranging from 0.012 Pa to 120 kPa, taking into account such line-shape effects as the speed dependence of collisional broadening and Dicke narrowing. We discuss limitations of an applicability of the Voigt profile for purposes of the Boltzmann constant determination. The influence of the model line-shape profile and the gas pressure range on the Doppler width extrapolated to the zero-pressure value is investigated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Small-angle X-ray and neutron scattering

Small-angle scattering (SAS) is a technique that is able to probe the structural organization of matter and quantify its response to changes in external conditions. X-ray and neutron scattering profiles measured from bulk materials or materials deposited at surfaces arise from nanostructural inhomogeneities of electron or nuclear density. Furthermore, the analysis of SAS data from coherent scattering events provides information about the length scale distributions of material components. Samples for SAS studies may be prepared in situ or under near-native conditions and the measurements performed at various temperatures, pressures, flows, shears or stresses, and in a time-resolved fashion. In this Primer, we provide an overview of SAS, summarizing the types of instrument used, approaches for data collection and calibration, available data analysis methods, structural information that can be obtained using the method, and data depositories, standards and formats. Recent applications of SAS in structural biology and the soft-matter and hard-matter sciences are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Density of States and the Ground State Structure in the Ising Model on a Kagome Lattice with Consideration for Next-Nearest-Neighbor Interaction

Phase transitions and thermodynamic properties have been studied in the two-dimensional antiferromagnetic Ising model on a Kagome lattice by the Monte Carlo method with consideration for both nearest- and next-nearest-neighbor interaction. Using the histogram data analysis method, it has been shown that the studied model is characterized by a second-order phase transition. The temperature dependence of thermodynamic parameters has been revealed to exhibit abnormal behavior.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Application of maximum likelihood methods to laser Thomson scattering measurements of low density plasmas

Laser Thomson scattering (LTS) is an established plasma diagnostic technique that has seen recent application to low density plasmas. It is difficult to perform LTS measurements when the scattered signal is weak as a result of low electron number density, poor optical access to the plasma, or both. Photon counting methods are often implemented in order to perform measurements in these low signal conditions. However, photon counting measurements performed with photo-multiplier tubes are time consuming and multi-photon arrivals are incorrectly recorded. In order to overcome these shortcomings a new data analysis method based on maximum likelihood estimation was developed. The key feature of this new data processing method is the inclusion of non-arrival events in determining the scattered Thomson signal. Maximum likelihood estimation and its application to Thomson scattering at low signal levels is presented and application of the new processing method to LTS measurements performed in the plume of a 2-kW Hall-effect thruster is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and Generalization of a Method for Precise Size Measurements of Metal Nanoclusters on Supports

We recently described a data analysis method for precise ({approx}0.1 {angstrom} random error in the mean for a 200 kV instrument with a 3 {angstrom} FWHM probe size) size measurements of small clusters of heavy metal atoms on supports as imaged in a scanning transmission electron microscope, including an experimental demonstration using clusters that were primarily triosmium or decaosmium. The method is intended for low signal-to-noise ratio images of radiation-sensitive samples. We now present a detailed analysis, including a generalization to address issues of particle anisotropy and biased orientation distributions. In the future, this analysis should enable extraction of shape as well as size information, up to the noise-defined limit of information present in the image. We also present results from an extensive series of simulations designed to determine the method's range of applicability and expected performance in realistic situations. The simulations reproduce the experiments quite accurately, enabling a correction of systematic errors so that only the {approx}0.1 {angstrom} random error remains. The results are very stable over a wide range of parameters. We introduce a variation on the method with improved precision and stability relative to the original version, while also showing how simple diagnostics can test whether the results are reliable in any particular instance.

36 MATERIALS SCIENCE↗

Identifying preferential flow from soil moisture time series: Review of methodologies

Abstract Identifying and quantifying preferential flow (PF) through soil—the rapid movement of water through spatially distinct pathways in the subsurface—is vital to understanding how the hydrologic cycle responds to climate, land cover, and anthropogenic changes. In recent decades, methods have been developed that use measured soil moisture time series to identify PF. Because they allow for continuous monitoring and are relatively easy to implement, these methods have become an important tool for recognizing when, where, and under what conditions PF occurs. The methods seek to identify a pattern or quantification that indicates the occurrence of PF. Most commonly, the chosen signature is either (1) a nonsequential response to infiltrated water, in which soil moisture responses do not occur in order of shallowest to deepest, or (2) a velocity criterion, in which newly infiltrated water is detected at depth earlier than is possible by nonpreferential flow processes. Alternative signatures have also been developed that have certain advantages but are less commonly utilized. Choosing among these possible signatures requires attention to their pertinent characteristics, including susceptibility to errors, possible bias toward false negatives or false positives, reliance on subjective judgments, and possible requirements for additional types of data. We review 77 studies that have applied such methods to highlight important information for readers who want to identify PF from soil moisture data and to inform those who aim to develop new methods or improve existing ones. Core Ideas Soil moisture data can be used to identify the occurrence of preferential flow (PF) and its initiating conditions. Various data‐analysis methods to identify PF differ in susceptibility to error, bias, and subjectivity. These methods can utilize vast amounts of data from soil moisture monitoring networks to develop understanding of when, where, and under what conditions PF occurs. Newly developed methods may lead to better accuracy and reliability, and reduce the need for subjective judgments. Plain Language Summary Preferential flow through soil occurs when a large amount of water is suddenly available, as during an intense storm. This type of flow moves rapidly through the soil in distinct narrow pathways rather than moving evenly throughout the body of soil, with major consequences for groundwater resources, ecosystems, spreading of contaminants, and other vital concerns. Methods of detecting preferential flow have been developed that utilize measurements of soil water content made by sensors installed at various depths. This measurement technology has been widely implemented, many locations now having datasets years in length, and various methods have been developed for using these to identify preferential flow. The various methods are based on different features in the soil moisture records and vary in their advantages and shortcomings. In this review, we explain and evaluate these methods, highlighting important information for their implementation to identify preferential flow from soil moisture data and for efforts to develop new methods or improve existing ones.

Nimmo, John R↗