Solute rejection by porous glass membranes. II - Pore size distributions and membrane permeabilities.
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The problem of waste management in space is discussed for manned space flight. It is shown that such waste can be accounted for in one of four ways: (1) the waste may be dumped into space; (2) it may be accumulated for return to earth; (3) the waste may be separated into two fractions, one fraction (water) to be dumped into space and the remaining portion to be returned to earth; or (4) the waste components may be beneficially reused.
A new membrane-casting apparatus is developed for studying macrovoid defects in polymeric membranes made by the wet- and dry-casting process in low-gravity. Macrovoids are large (10-50 micron), open cavities interspersed among the smaller pores in the substructure under the gelled skin surface layer of the cast membrane. Although their occurrence is considered endemic to the wet- and dry-casting process since they can lead to compaction or skin rupture in the membrane process, recent studies suggest several useful applications such as transdermal and osmotic drug delivery systems, miniature bioreactors, etc. However, lack of knowledge about the macrovoid formation mechanism is an obstacle to further development of applications using them. An on-going debate is the role of the surface-tension-driven solutocapillary convection during macrovoid formation. The rapid growth of macrovoids within 1-5 seconds and the high polymer concentration in and near macrovoids make it difficult to explain the mechanism of macrovoid growth by diffusion alone, which is the widely accepted hypothesis proposed by Reuvers et al. The hypothesis advanced by our research group can explain this rapid growth via a mechanism that involves diffusion from the casting solution in the meta-stable region to the macrovoid enhanced by solutocapillary convection induced by the steep nonsolvent concentration gradient in the vicinity of the macrovoid. Since macrovoid growth is hypothesized to be the interplay of a solutocapillary-induced driving force counteracted by viscous drag and buoyancy, eliminate the latter provides a means for testing this hypothesis. Moreover, free convection mass transfer in the nonsolvent immersion bath used to cause phase-separation in membrane casting complicates developing a model for both the wet-casting process and macrovoid growth. The low-g environment minimizes gravitationally induced free convection thereby permitting a tractable solution to the ternary diffusion equations that characterize membrane formation. NASA's Parabolic Flight Research Aircraft provides a small window of low-g (approximately 25 s) that can be used to study macrovoid development in both wet- and dry-cast membranes if an appropriate casting apparatus is used. This casting apparatus should be able to cast the membrane in both low- and high-g in a manner so that essential one-dimensional mass transfer conditions are achieved to insure lateral uniformity in the membrane. The apparatus used in previous research on membrane casting in low-gravity was operated with the plunger driven mechanism. The spring-loaded plunger pushes the bottom block containing the polymer casting solution well directly under the absorbent chamber located in the upper stationary block. However, membranes made via this casting apparatus often displayed lateral nonuniformities that precluded obtaining quantitative information on the macrovoid growth process. Thus, it was necessary to determine the reason for these structural irregularities observed in the low-g casting apparatus. Both experimental as well as computer simulation studies of the low-g casting apparatus established that the impulsive action of the plunger caused the undesired structural nonuniformities. The simulation results showed that the width-to-depth aspect ratio of the shallow well that contains the casting solution in this apparatus was not an important factor in minimizing this problem. Even for a 40:1 (width : depth) aspect ratio, any convection induced by the horizontal motion of the interface of the casting solution will be damped out within 6.25x10(exp 4) seconds. However, the experimental studies revealed that the impulsive motion of the plunger caused a 'sloshing' of the casting solution that had to be eliminated. Therefore, the plungerdriven mechanism was changed to a cam-driven mechanism that did not cause any impulsive motion of the casting solution. Other refinements to this new membrane-casting apparatus include provision for removing the membranes from the casting wells in a less destructive manner. This was accomplished by using a slit geometry for the casting well that permitted disassembly for removal of the cast membrane. The materials used in the construction of this casting apparatus were chosen to insure wetting at the side walls and to maintain precise control of the thickness of the polymer solution in the casting well. An additional provision in this new casting apparatus is the ability to carry out both wet- as well as dry-casting. As such, this apparatus permitted the first studies of the wet-casting of polymeric membranes in low-g. Both wet- and dry-casting experiments on NASA's KC-135 research aircraft employing this new membrane-casting apparatus are scheduled in July 2002. The morphology of the resulting membranes will be characterized using an environmental scanning electron microscope (ESEM). The results of these low-g studies will be reported later.
Membrane-based separations are widely used for wastewater treatment due to their low cost and efficiency. However, membrane fouling, which is the unwanted deposition or attachment of contaminants on membrane surfaces and/or within membrane pores, remains a major challenge as it increases the mass transfer resistance and reduces membrane productivity. Membrane fouling is typically probed by macroscopic performance metrics, such as flux decline, and ex situ characterization. However, this does not capture the membrane and fouling layer evolution under operating conditions, potentially masking important mechanisms and nonequilibrium pathways that impact fouling. Here, we present a remotely controlled crossflow membrane system and a custom membrane cell for operando fouling characterization using transmission small/wide angle x-ray scattering (SAXS/WAXS). This approach allows direct observation of the nanoscale changes occurring at the membrane surface during pressurized water treatment processes, enabling a new way to understand the connections between dynamic fouling behaviors and membrane performance. Nanoparticle fouling of porous membranes during ultrafiltration was investigated using operando SAXS, and mineral scaling of reverse osmosis membranes was investigated using operando WAXS. Furthermore, this system allows for tracking membrane fouling in real time and under realistic conditions, providing fundamental physical insights into how water chemistry and operating conditions affect macroscopic membrane performance. Moreover, this system opens the door for future in situ and operando studies, and it serves as a testbed for evaluating novel materials/processes for membrane-based separations.
The conversion of lignocellulosic biomass into biofuels and bioproducts by microbial biorefineries is central to a sustainable chemical industry. Zymomonas mobilis is one such biorefinery chassis and is resistant to ethanol stress, leading to its use in biomass conversion to biofuels and bioproducts. However, Z. mobilis growth is often inhibited by organic acids, aldehydes, alcohols, ketones, and amides found in biomass hydrolysate. The resulting slow growth inhibits production and as a result drives up the price for the resulting products. One hypothesis is that these molecules interact with or disrupt the bacterial membrane, triggering stress responses and hindering growth. To test this hypothesis at the molecular level, we employ all-atom molecular dynamics (MD) simulations to investigate lignocellulose-derived small molecules and their impact on a biologically relevant Z. mobilis membrane model. Simulations were conducted across a range of inhibitor concentrations from 0 to 2.5 mol %, analyzing key membrane properties such as area per lipid (APL), membrane thickness, lipid-order parameter (−S CH ), lateral diffusion coefficient (D xy ), and permeability coefficient (Pm). From simulation, we observed altered membrane structure and dynamics at these modest small molecule concentrations commonly found in hydrolysates. Generally, the membranes become thinner, with a higher area per lipid and lower-order parameter as the small molecule concentration increases. These trends are stronger for more hydrophobic molecules with greater hydrophobic bulk, as isobutanol, propanol, and propanoic acid showed greater membrane perturbations as the concentration increased compared to other small molecules. Tracking small molecule distributions directly in our equilibrium simulations allows us to determine concentration-dependent free energy profiles for these molecules. While the trends are noisy, generally the barriers to crossing the membrane decrease as the concentration increases, indicating that the membranes become leakier as small molecule concentrations rise. Comparing between native Z. mobilis membranes with hopanoids and membranes sharing the same phospholipid composition but without hopanoids, hopanoids stabilize and order the membrane for smaller molecules to maintain membrane structure but appear insufficient for larger hydrophobic molecules like isobutanol. These findings provide a mechanistic understanding of how small molecules found in biomass degradation streams interact with the Z. mobilis membrane, offering valuable insights for future strain engineering efforts to optimize biofuel and bioproduct synthesis from biomass feedstocks by highlighting limits to small molecule tolerance. This knowledge can guide the modification of membrane composition to develop more robust microbes, thereby improving microbial survival and yields in industrial contexts.
The objective of CAM is to develop, test, and analyze thin film membrane materials for separation and purification of carbon dioxide (CO2) from mixtures of gases, such as those found in the Martian atmosphere. The membranes are targeted toward In Situ Resource Utilization (ISRU) applications that will operate in extraterrestrial environments and support future unmanned and human space missions. A primary application is the Sabatier Electrolysis process that uses Mars atmosphere CO2 as raw material for producing water, oxygen, and methane for rocket fuel and habitat support. Other applications include use as an inlet filter to collect and concentrate Mars atmospheric argon and nitrogen gases for habitat pressurization, and to remove CO2 from breathing gases in Closed Environment Life Support Systems (CELSS). CAM membrane materials include crystalline faujasite (FAU) zeolite and rubbery polymers such as silicone rubber (PDMS) that have been shown in the literature and via molecular simulation to favor adsorption and permeation of CO2 over nitrogen and argon. Pure gas permeation tests using commercial PDMS membranes have shown that both CO2 permeance and the separation factor relative to other gases increase as the temperature decreases, and low (Delta)P(Sub CO2) favors higher separation factors. The ideal CO2/N2 separation factor increases from 7.5 to 17.5 as temperature decreases from 22 C to -30 C. For gas mixtures containing CO2, N2, and Ar, plasticization decreased the separation factors from 4.5 to 6 over the same temperature range. We currently synthesize and test our own Na(+) FAU zeolite membranes using standard formulations and secondary growth methods on porous alumina. Preliminary tests with a Na(+) FAU membrane at 22 C show a He/SF6 ideal separation factor of 62, exceeding the Knudsen diffusion selectivity by an order of magnitude. This shows that the membrane is relatively free from large defects and associated non-selective (viscous flow) transport mechanisms. The Membrane Test Facility (MTF) has been developed to measure membrane permeance over a wide range of temperature and pressure. The facility uses two volume compartments separated by the membrane that are instrumented to measure temperature, delta pressure across the membrane, and gas composition. A thermal shroud supports and encloses the membrane, and provides temperature control. Methods were developed to determine membrane permeance using the first order decay of the pressure difference between the sealed compartments, using the total pressure for pure gases, and partial pressure of each species in gas mixtures. The technique provides an end-to-end measurement of gas permeance that includes concentration polarization effects. Experiments have shown that in addition to membrane permeance properties, the geometry and design of associated structures play an important role in how membrane systems will function on Mars.
The integration of catalysts onto the surface of membranes enables simultaneous physical separation and catalytic transformation of constituents in a feed stream, facilitating improved contaminant removal and fouling mitigation. Distillation membranes are a particularly attractive platform for catalytic membranes because they reject nonvolatile species and exhibit exceptional resistance to oxidative and radical-driven degradation. However, imparting catalytic functionality onto hydrophobic, porous distillation membranes has proven challenging since the membranes used are chemically inert and difficult to modify. Furthermore, catalysts on the membrane surface can decrease hydrophobicity and increase the membrane’s susceptibility to pore wetting and failure. In this work, we create a catalytic distillation membrane by coating a polytetrafluoroethylene membrane surface with titanium dioxide (TiO 2 ) via plasma-assisted atomic layer deposition (ALD). By precisely tuning the ALD parameters, we demonstrate localized growth of TiO 2 near (within approximately 1 μm) the surface of polytetrafluoroethylene membranes, forming a catalytically active interface while preserving the underlying hydrophobic pore structure. Localized growth of TiO 2 is confirmed by electron microscopy and spectroscopy techniques, and membranes coated with 500 cycles of ALD show pressure tolerance up to 12.8 bar and higher than 95% salt rejection in pressure-driven distillation. Photocatalytic activity is demonstrated via the degradation of methylene blue dye under UV irradiation, where increasing TiO2 loading leads to an enhancement in dye degradation. These results establish a general strategy for integrating catalytic functionality into chemically inert, hydrophobic membranes without compromising distillation performance, providing a pathway toward multifunctional membranes that couple advanced oxidation with membrane separation for water treatment.
The goal of achieving energy-efficient, precise molecular separations has motivated interest in developing and employing porous crystalline frameworks as membrane materials. Covalent organic frameworks (COFs) are ordered crystalline matrices composed of covalently bonded organic monomers and are synthesized via reversible reticular chemistry. COFs possess high porosity, structural tunability, and chemical and thermal stability, making them ideally suited for emerging, high-value membrane separation processes, such as ion separations, organic solvent nanofiltration, and gas separations. Although a range of COF membranes have been fabricated and tested in the past decade, these membranes are primarily polycrystalline, weakly crystalline, and/or discontinuous, resulting in suboptimal performance. In this review, we identify the properties that make COFs well-suited as membrane materials, while critically outlining the shortcomings of existing disordered COF membranes. We then highlight the recent emergence of highly crystalline, continuous, oriented two-dimensional COF membranes as a promising path forward for highly selective molecular separations. These continuous, oriented COF membranes exhibit tunable one-dimensional nanochannels, allowing for ultrafast molecular transport and precise species selectivity, thereby expanding the set of separations that can be practically achieved with membrane systems. We discuss synthesis and modification techniques that result in continuous, oriented COF membranes and evaluate the performance of such membranes for a variety of molecular separations. We conclude by identifying ongoing challenges in the development of COF membranes and outlining the future of their applications in molecular separations, which will necessarily rely on advancements in the synthesis of continuous, oriented membranes.
Graphene-based materials, such as graphene and graphene oxide (GO), have been considered as next-generation membrane materials. GTI Energy and The State University of New York at Buffalo (UB) have been developing a transformational GO-based membrane process (designated as GO2) that integrates a high CO 2 /N 2 selectivity membrane (GO-1) and a high CO 2 flux membrane (GO-2) for post-combustion CO 2 capture. An innovative membrane structure, consisting of GO nanochannels intercalated by single-walled carbon nanotube (SWCNT), was developed. The membrane prepared on hollow fiber substrate showed CO 2 permeance as high as 1,300 GPU with CO 2 /N 2 selectivity >200. The membranes were successfully scaled up to effective area of 50-100 cm 2 . The 50-100 cm 2 membranes showed CO 2 /N 2 selectivity ≥200 and CO 2 permeance ≥1,000 GPU for the GO-1 type, and CO 2 /N 2 selectivity ≥20 and CO 2 permeance ≥2,500 GPU for the GO-2 type. The CO 2 capture performance of the GO-based membranes was tested using a simulated flue gas. The testing results indicate that the GO-based membranes are stable in the presence of flue gas contaminants. The GO-based membranes were then further scaled up to a surface area of 1,000 cm 2 . Good stability was achieved during an integrated testing with GO-1 and GO-2 membranes using simulated flue gas. A bench-scale system was designed, constructed, and tested at the National Carbon Capture Center (NCCC). Good stability was achieved during testing of a single-stage process with >10 shutdowns/startups at NCCC. During the integrated testing, the membranes showed good stability at 50°C and 57°C. 70-90% CO 2 removal efficiencies and ≥95% CO 2 purity were validated during the steady state operation at NCCC. Techno-economic analysis indicates the GO2 membrane-based process technology provides a reduction in both the levelized cost of electricity (LCOE) and cost of capture when compared to the reference B12B case presented in the Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity study prepared by the National Energy Technology Laboratory (NETL), before considering any system optimization or improvement opportunities. The benefits are primarily driven by a reduction in the equipment costs of the CO 2 capture process vs. the solvent-based reference process in NETL Case B12B as well as a decrease in the base plant size.
The upper part of the figure depicts an aperture-coupled L-band antenna comprising patterned metal conductor films supported on two thin polyimide membranes separated by an air gap. In this antenna, power is coupled from a microstrip line on the lower surface of the lower membrane, through a slot in a metal ground plane on the upper surface of the lower membrane, to a radiating metal patch on the upper surface of the upper membrane. The two-membrane configuration of this antenna stands in contrast to a three-membrane configuration heretofore considered as the basis for developing arrays of dual-polarization, wideband microwave antennas that could be thin and could be, variously, incorporated into, or supported on, thin structures, including inflatable structures. By reducing the number of membranes from three to two, the present design simplifies the problems of designing and fabricating such antennas or arrays of such antennas, including the problems of integrating such antennas or arrays with thin-membrane-mounted transmit/ receive modules. In addition, the use of aperture (slot) coupling eliminates the need for rigid coaxial feed pins and associated solder connections on thin membranes, making this antenna more mechanically reliable, relative to antennas that include coaxial feed pins. This antenna is designed for a nominal frequency of 1.26 GHz. The polyimide membranes are 0.05 mm thick and have a relative permittivity of 3.4. The radiating patch is square, 8.89 cm on each side. This radiating patch lies 1.27 cm above the ground plane. The feeding microstrip line is 0.12 mm wide and has a characteristic impedance of 50 . The aperture-coupling slot, etched in the ground plane, is 0.48 mm wide and 79.5 mm long. In order to maximize coupling, the microstrip line is extended beyond the middle of the slot by a length of 36 mm, which corresponds to a transmission- line electrical length of about a quarter wavelength. The other end of the microstrip line is transformed to a 50-Ohm coplanar waveguide line, which is used for connection to a transmit/receive module. Some plated-through vias are added to the outer conductors of the coplanar waveguide to suppress parallel-plate modes. The measured and calculated 10-dB-return-loss bandwidth of the antenna is 100 MHz. By eliminating the radiating patch and the upper membrane that supports it, and performing two other simple modifications, one can convert the two-membrane antenna described above to a paper-thin single-membrane antenna, shown in the lower part of the figure. One modification is to increase the slot length to 104.95 mm; the other is to extend the microstrip to 36.68 mm past the middle of the slot. With these modifications, the slot now becomes a half-wavelength radiator with a nearly omnidirectional radiation pattern. In one potential use, such a paper-thin antenna could be pasted on an automobile window to enable omnidirectional communication.
Membranes are essential components of photoelectrochemical CO 2 reduction cells (PEC-CRC), as they regulate solute transport and impact device efficiency. These cells are a promising approach for converting carbon dioxide into valuable chemicals. However, electrochemical reactions involve not just a single electrolyte; membrane transport typically includes multiple electrolytes. When a mixture of solutes is present, the presence of one solute in the membrane can impact the diffusion and sorption of other solutes. In complex systems where multiple solutes are diffusing simultaneously through a hydrated, dense polymer membrane, the resulting transport behavior is poorly understood. This study highlights the individual and two solute transport behavior of potassium formate, acetate, and bicarbonate ions in neutral membranes and quaternary ammonium-functionalized anion exchange membranes (AEMs) based on phenyl acrylate polymer backbones. By isolating the effect of water content, we emphasize how fixed charge density and solute-membrane interactions influence transport behavior. In neutral membranes, the diffusivity follows the order of potassium formate > potassium acetate > potassium bicarbonate. However, in AEMs, the order shifts due to changes in ion-membrane interactions, with potassium bicarbonate diffusivity surpassing that of potassium acetate. These results underscore the importance of ion exchange membranes and ion-membrane interaction in modulating transport properties, providing valuable insights for optimizing membranes in electrochemical applications.
Abstract Approximately one-third of global CO 2 assimilation is performed by the pyrenoid, a liquid-like organelle found in most algae and some plants. Specialized pyrenoid-traversing membranes are hypothesized to drive CO 2 assimilation in the pyrenoid by delivering concentrated CO 2 , but how these membranes are made to traverse the pyrenoid matrix remains unknown. Here we show that proteins SAGA1 and MITH1 cause membranes to traverse the pyrenoid matrix in the model alga Chlamydomonas reinhardtii . Mutants deficient in SAGA1 or MITH1 lack matrix-traversing membranes and exhibit growth defects under CO 2 -limiting conditions. Expression of SAGA1 and MITH1 together in a heterologous system, the model plant Arabidopsis thaliana , produces matrix-traversing membranes. Both proteins localize to matrix-traversing membranes. SAGA1 binds to the major matrix component, Rubisco, and is necessary to initiate matrix-traversing membranes. MITH1 binds to SAGA1 and is necessary for extension of membranes through the matrix. Our data suggest that SAGA1 and MITH1 cause membranes to traverse the matrix by creating an adhesive interaction between the membrane and matrix. Our study identifies and characterizes key factors in the biogenesis of pyrenoid matrix-traversing membranes, demonstrates the importance of these membranes to pyrenoid function and marks a key milestone toward pyrenoid engineering into crops for improving yields.
Gas traps are critical for the smooth operation of coolant loops because gas bubbles can cause loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and blockage of passages to remote systems. Coolant loops are ubiquitous in space flight hardware, and thus there is a great need for this technology. Conventional gas traps will not function in micro-gravity due to the absence of buoyancy forces. Therefore, clever designs that make use of adhesion and momentum are required for adequate separation, preferable in a single pass. The gas traps currently used in water coolant loops on the International Space Station are composed of membrane tube sets in a shell. Each tube set is composed of a hydrophilic membrane (used for water transport and capture of bubbles) and a hydrophobic membrane (used for venting of air bubbles). For the hydrophilic membrane, there are two critical pressures, the pressure drop and the bubble pressure. The pressure drop is the decrease in system pressure across the gas trap. The bubble pressure is the pressure required for air bubbles to pass across the water filled membrane. A significant difference between these pressures is needed to ensure complete capture of air bubbles in a single pass. Bubbles trapped by the device adsorb on the hydrophobic membrane in the interior of the hydrophilic membrane tube. After adsorption, the air is vented due to a pressure drop of approximately 1 atmosphere across the membrane. For water systems, the air is vented to the ambient (cabin). Because water vapor can also transport across the hydrophobic membrane, it is critical that a minimum surface area is used to avoid excessive water loss (would like to have a closed loop for the coolant). The currently used gas traps only provide a difference in pressure drop and bubble pressure of 3-4 psid. This makes the gas traps susceptible to failure at high bubble loading and if gas venting is impaired. One mechanism for the latter is when particles adhere to the hydrophobic membrane, promoting formation of a water layer about it that can blind the membrane for gas transport (Figure 1). This mechanism is the most probable cause for observed failures with the existing design. The objective of this project was to devise a strategy for choosing new membrane materials (database development and procedure), redesign of the gas trap to mitigate blinding effects, and to develop a design that can be used in ammonia and Freon-21 coolant loops.
A system was developed in which nutrient flow to plant roots is controlled by a thin (0.98 or 1.18 mm) porous (0.2 or 0.5 microns) stainless steel sheet membrane. The flow of nutrient solution through the membrane is controlled by adjusting the relative negative pressure on the nutrient solution side of the membrane. Thus, the nutrient solution is contained by the membrane and cannot escape from the compartment even under microgravity conditions if the appropriate pressure gradient across the membrane is maintained. Plant roots grow directly on the top surface of the membrane and pull the nutrient solution through this membrane interface. The volume of nutrient solution required by this system for plant growth is relatively small, since the plenum, which contains the nutrient solution in contact with the membrane, needs only to be of sufficient size to provide for uniform flow to all parts of the membrane. Solution not passing through the membrane to the root zone is recirculated through a reservoir where pH and nutrient levels are controlled. The size of the solution reservoir depends on the sophistication of the replenishment system. The roots on the surface of the membrane are covered with a polyethylene film (white on top, black on bottom) to maintain a high relative humidity and also limit light to prevent algal growth. Seeds are sown directly on the stainless steel membrane under the holes in the polyethylene film that allow a pathway for the shoots.
Driven by environmental and health concerns related to per- and polyfluoroalkyl substances (PFAS), there has been growing interest in developing fluorine-free proton (H + ) exchange membrane (PEM) materials for fuel cells and water electrolyzers. In this study, we present a side-by-side comparison of the key transport properties of submicron thick, PFAS-free amorphous silicon dioxide (SiO 2 ) membranes to Nafion, a fluorinated polymer electrolyte membrane that represents the industry standard for PEM fuel cells and electrolyzers. Here, measurements of proton (H + ) conductivity (σ H + ), hydrogen (H 2 ) permeability (P H 2 ), and electrical resistivity (ρ e – ) were conducted using model thin films comprised of SiO 2 membranes deposited by atomic layer deposition (ALD). Although the H + conductivity of the SiO 2 membranes is 2–3 orders of magnitude lower than Nafion, the addition of phosphorus dopants (PO x ) improves H + conductivity such that the area specific membrane resistance of thin (<50 nm) PO x -doped SiO 2 membranes is more than an order of magnitude lower than Nafion-117. Importantly, the safe operation of such nanoscale membranes within a PEM electrolyzer is feasible thanks to the low H 2 permeability of dense SiO 2 -based membranes, which are predicted to limit H 2 crossover rates to acceptable levels for pressures up to ≈ 100 bar. As a proof-of-principle demonstration, a chip-scale water electrolyzer based on 100 nm thick PO x -SiO 2 membrane is shown to achieve a current density of 2 A cm –2 at a potential of 2.5 V. If this technology can be successfully scaled up, H + conducting oxide membranes offer an attractive PFAS-free alternative to Nafion for efficient and durable water electrolysis and fuel cell technologies.
Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.
Bipolar membranes (BPMs) used for water treatment suffer from interface instabilities, causing premature failure and decreased performance. Recent research has highlighted the impacts of membrane morphology on mechanical behavior and performance. Improved material performance of thin film membranes requires enhanced transport properties coupled with better control of the mechanical characteristics to avoid premature failure of the film. Thus, morphology is a key parameter when developing and evaluating novel membrane materials. Microscopy offers unique advantages for nano-scale characterization of thin film membrane interfaces and morphologies. In this study, the interface junction of BPMs was evaluated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). BPMs were fabricated using (1) hot pressing lamination, (2) bench-scale solution casting, and (3) roll-to-roll sequential casting (R2R). Both commercial and in-house fabricated ion exchange membranes were used in the BPMs. The BPMs were comprised of a cation exchange membrane and an anion exchange membrane with a catalyst layer sandwiched in between. Cross sectional SEM and EDX images of the membrane interface junction were compared among the different fabrication techniques and materials. The bench cast catalyst layers were nonuniform compared to the R2R and hot pressed membranes, demonstrating the importance of precise catalyst application conditions. Different thicknesses of the BPMs and individual membrane layers revealed that polymer solution concentration needs to be optimized during manufacturing. This work shows that microscopy can identify key processing parameters that affect BPM interface junction quality at the microscale to enable manufacturing of high performance BPMs.
Wastewater treatment through Forward Osmosis (FO) membranes is a process that has been evaluated in the past years as an innovative technology for the Next Generation Life Support Systems. FO technologies are cost effective, and require very low energy consumption, but are subject to membrane fouling. Membrane fouling occurs when unwanted materials accumulate on the active side of the membrane during the wastewater treatment process, which leads to a decrease in membrane flow rates. Membrane fouling can be reversed with the use of antifoulant solutions. The aim of this study is to identify the materials that cause flow rate reduction due to membrane fouling, as well as to evaluate the flux recovery after membrane treatment using commercially available antifoulants. 3D Laser Scanning Microscope images were taken to observe the surface of the membrane. Fourier Transform Infrared (FTIR) spectrometry results identified possible compounds that cause membrane fouling and FO testing results demonstrated flow rate recovery after membrane treatment using antifoulants.