Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Medical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Activator-doped Hg 2 Br 2 as next generation high performance scintillator for high energy physics research and other scientific and imaging applications

Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.

36 MATERIALS SCIENCE↗

An Overview of Emerging Nuclear Sensor Technologies: Challenges, Advancements and Applications

Nuclear sensors are essential for detecting and measuring nuclear radiation in various applications, including nuclear power plants, medical imaging, and environmental monitoring. Traditional nuclear sensors have served these fields for decades, but recent advancements in emerging sensor technologies offer novel improvements in accuracy, sensitivity, and reliability. This review presents an up-to-date overview of recent progress in the advancements of nuclear sensor technologies, their diverse applications, challenges in implementation, and opportunities for future research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metal Halide Scintillators with Fast and Self‐Absorption‐Free Defect‐Bound Excitonic Radioluminescence for Dynamic X‐Ray Imaging

Abstract Scintillators for radiation detection are of great significance in medical imaging, security, and nondestructive inspection. The current challenge for scintillators is to simultaneously achieve high scintillation light yield, fast radioluminescence, simple film fabrication, large X‐ray attenuation efficiency as well as stable and nontoxic compositions; no previous scintillators fulfill all the above requirements. Here, metal halide Rb 2 AgBr 3 , possessing defect‐bound excitonic radioluminescence, is shown as efficient and fast scintillators. This nontoxic and stable scintillator emits from excitons bound to neutral bromine vacancies, enjoying an efficient and spin‐allowed fast emission with minimized self‐absorption. Rb 2 AgBr 3 thus has a high light yield (25 600 photons MeV −1 ), fast scintillation decay time (5.31 ns), and a record value of light yield versus decay time (4821 photons MeV −1 ns −1 ). The close‐space sublimation method is developed for fast and scalable fabrication of oriented Rb 2 AgBr 3 films. The scintillator film is further integrated with commercial flat‐panel imagers, and the spatial resolution reaches 10.2 line pairs per millimeter at the modulation transfer function of 0.2, doubling the resolution of conventional CsI:Tl flat‐panel detectors. The dynamic X‐ray imaging and its use to real‐time monitoring of bone movement without ghosting effect is also demonstrated.

Zhang, Muyi↗

Optimization of selenium in CdZnTeSe quaternary compound for radiation detector applications

X- and gamma-ray detectors are increasingly becoming essential tool for science and technology in various fields include homeland security, nonproliferation, nuclear security, medical imaging, astrophysics, and high energy physics. Cd 1-x Zn x Te 1-y Se y (CZTS) is emerging as a next-generation compound semiconductor for such applications. CZTS was found to possesses a very low concentration of Te inclusions and free from sub-grain boundary networks. Being a quaternary compound with varying alloy composition, optimization of the composition was performed to determine the minimum amount of selenium required to produce CZTS with reduced defects. The optimized composition was found to be x=0.10 and y=0.02, i.e., Cd 0.9 Zn0.1Te 0.98 Se 0.02 , for excellent material properties as a radiation detector. The resulting material was free from sub-grain boundary networks and with a highly reduced concentration of Te inclusions. The bulk dark resistivity obtained was in the range of 1-3x1010 ohm-cm with the highest achieved mobility-lifetime product of ~6.6x10-3 cm2/V for the optimized CZTS composition. Impurity analyses were performed by the Glow Discharge Mass Spectroscopy (GDMS) technique, and the results showed relatively high impurity concentrations compared to commercial detector-grade CdZnTe. Thus, CZTS has room for further improvement with additional purification of the starting materials.

36 MATERIALS SCIENCE↗

Stabilization and control of persistent current magnets using variable inductance

Ultra-stable, tunable magnetic fields are desirable for a wide range of applications in medical imaging, electron microscopy, quantum science, and atomic physics. Superconducting magnets operated in persistent current mode, with device current flowing in a closed superconducting loop disconnected from a power source, are a common approach for applications with the most stringent requirements on temporal field stability. In this work, we present a method for active control of this persistent current by means of dynamic inductance change within the superconducting circuit. For a first realization of this general technique, we consider a variable superconducting inductor placed in series with the main magnet. The inductor acts as a dynamic flux storage device capable of transferring flux to or from the main magnet through inductance change. This allows for fine and fast adjustments of the persistent current without the use of thermal switches that limit the speed and accuracy of many present-day methods. With first experiments employing this technique, we demonstrate stabilization of a 1.95 T Nb–Ti round lens for electron microscopy against decay resulting from residual losses in the superconducting circuit, and more generally show flexibility for precise control over the magnitude and waveform of the persistent current.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi-frequency progressive refinement for learned inverse scattering

Interpreting scattered acoustic and electromagnetic wave patterns is a computational task that enables remote imaging in a number of important applications, including medical imaging, geophysical exploration, sonar and radar detection, and nondestructive testing of materials. However, accurately and stably recovering an inhomogeneous medium from far-field scattered wave measurements is a computationally difficult problem, due to the nonlinear and non-local nature of the forward scattering process. We design a neural network, called Multi-Frequency Inverse Scattering Network (MFISNet), and a training method to approximate the inverse map from far-field scattered wave measurements at multiple frequencies. We consider three variants of MFISNet, with the strongest performing variant inspired by the recursive linearization method — a commonly used technique for stably inverting scattered wavefield data — that progressively refines the estimate with higher frequency content. MFISNet outperforms past methods in regimes with high-contrast, heterogeneous large objects, and inhomogeneous unknown backgrounds.

97 MATHEMATICS AND COMPUTING↗

Breakthrough MEG Technology [Slides]

LANL technology is a disruptive innovation to change market dynamics. For medical imaging experts who want to rapidly diagnose brain disorders, our LANL breakthrough MEG solution delivers faster and easier brain imaging without having to go to major urban medical centers.

59 BASIC BIOLOGICAL SCIENCES↗

Deep learning applications in visual data for benign and malignant hematologic conditions: a systematic review and visual glossary

Deep learning (DL) is a subdomain of artificial intelligence algorithms capable of automatically evaluating subtle graphical features to make highly accurate predictions, which was recently popularized in multiple imaging-related tasks. Because of its capabilities to analyze medical imaging such as radiology scans and digitized pathology specimens, DL has significant clinical potential as a diagnostic or prognostic tool. Coupled with rapidly increasing quantities of digital medical data, numerous novel research questions and clinical applications of DL within medicine have already been explored. Similarly, DL research and applications within hematology are rapidly emerging, although these are still largely in their infancy. Given the exponential rise of DL research for hematologic conditions, it is essential for the practising hematologist to be familiar with the broad concepts and pitfalls related to these new computational techniques. This narrative review provides a visual glossary for key deep learning principles, as well as a systematic review of published investigations within malignant and non-malignant hematologic conditions, organized by the different phases of clinical care. In order to assist the unfamiliar reader, this review highlights key portions of current literature and summarizes important considerations for the critical understanding of deep learning development and implementations in clinical practice.

60 APPLIED LIFE SCIENCES↗

An image-driven machine learning approach to kinetic modeling of a discontinuous precipitation reaction

Micrograph quantification is an essential component of several materials science studies. Machine learning methods, in particular convolutional neural networks, have previously demonstrated performance in image recognition tasks across several disciplines (e.g. materials science, medical imaging, facial recognition). Here, we apply these well-established methods to develop an approach to microstructure quantification for kinetic modeling of a discontinuous precipitation reaction in a case study on the uranium-molybdenum system. Prediction of material processing history based on image data (classification), calculation of area fraction of phases present in the micrographs (segmentation), and kinetic modeling from segmentation results were performed. Results indicate that convolutional neural networks represent microstructure image data well, and segmentation using the k-means clustering algorithm yields results that agree well with manually annotated images. Classification accuracies of original and segmented images are both 94% for a 5-class classification problem. Kinetic modeling results agree well with previously reported data using manual thresholding. The image quantification and kinetic modeling approach developed and presented here aims to reduce researcher bias introduced into the characterization process, and allows for leveraging information in limited image data sets.

36 MATERIALS SCIENCE↗

Performance Study of Virtual Frisch Grid CdZnTeSe Detectors

Nuclear detectors for x-ray and gamma-ray spectroscopy and imaging are a vital tool in many homeland security, medical imaging, astrophysics and other applications. Most of these applications require room-temperature operation due to the operational constraints imposed by a cryogenic cooling system. CdZnTe (CZT) has been the main material with the desired detection properties, and CZT crystals have been used commercially for three decades. However, CdZnTe still suffers from long-standing issues of high densities of performance-limiting intrinsic defects such as Te inclusions and networks of dislocation walls (sub-grain boundaries). A recently invented new quaternary material CdZnTeSe showed excellent material properties for radiation detection. The material was found to be free from dislocation networks, possess reduced Te inclusions, and have better compositional homogeneity. Virtual Frisch grid detectors were fabricated from crystals taken from a CdZnTeSe ingot that was grown by the traveling heater method. The detectors were fabricated from an as-grown ingot, bypassing the post-growth annealing process commonly practiced for industrial-grade CZT. The performances of the detectors were studied with different Frisch grid lengths using an amplifier shaping time ranging from 1–6 µs. The detectors showed high-quality spectroscopic performance with an as-measured energy resolution of ~1.1% at 662 keV for an optimum Frisch grid length of 3 mm. The charge collection was observed to enhance for longer Frisch grids.

47 OTHER INSTRUMENTATION↗

A new generation of direct X-ray detectors for medical and synchrotron imaging applications

Abstract Large-area X-ray imaging is one of the most widely used imaging modalities that spans several scientific and technological fields. Currently, the direct X-ray conversion materials that are being commercially used for large-area (> 8 cm × 4 cm without tiling) flat panel applications, such as amorphous selenium (a-Se), have usable sensitivities of up to only 30 keV. Although there have been many promising candidates (such as polycrystalline HgI 2 and CdTe), none of the semiconductors were able to assuage the requirement for high energy (> 40 keV) large-area X-ray imaging applications due to inadequate cost, manufacturability, and long-term performance metrics. In this study, we successfully demonstrate the potential of the hybrid Methylammonium lead iodide (MAPbI 3 ) perovskite-based semiconductor detectors in satisfying all the requirements for its successful commercialization in synchrotron and medical imaging. This new generation of hybrid detectors demonstrates low dark current under electric fields needed for high sensitivity X-ray imaging applications. The detectors have a linear response to X-ray energy and applied bias, no polarization effects at a moderate bias, and signal stability over long usage durations. Also, these detectors have demonstrated a stable detection response under BNL’s National Synchrotron Light Source II (NSLS-II) 70 keV monochromatic synchrotron beamline.

47 OTHER INSTRUMENTATION↗

Machine learning based reconstruction of intracardiac electrical behavior based on electrocardiograms

A computer-based system and process are disclosed for reconstructing the internal electrical behavior of a patient's heart based partly or wholly on the patient's electrocardiogram (ECG). The output of the process may include, for example, a cardiac activation map, and/or a representation of transmembrane potentials over time. The process advantageously does not require any medical imaging of the patient, and does not require any special medical equipment. For example, the patient's activation map and transmembrane potentials may be reconstructed based solely on a preexisting or newly-obtained 12-lead cardiac ECG of the patient. The process makes use of a machine learning model, such as a neural network based model, trained with actual and/or simulated ECGs and intracardiac electrical data (typically transmembrane potentials) of many thousands of patients. Because an insufficient quantity of such data exists for actual patients, model training may be performed using ECGs and intracardiac electrical data obtained through computer simulations.

Blake, Robert↗

Strictly Enforcing Invertibility and Conservation in CNN-Based Super Resolution for Scientific Datasets

Abstract Recently, deep convolutional neural networks (CNNs) have revolutionized image “super resolution” (SR), dramatically outperforming past methods for enhancing image resolution. They could be a boon for the many scientific fields that involve imaging or any regularly gridded datasets: satellite remote sensing, radar meteorology, medical imaging, numerical modeling, and so on. Unfortunately, while SR-CNNs produce visually compelling results, they do not necessarily conserve physical quantities between their low-resolution inputs and high-resolution outputs when applied to scientific datasets. Here, a method for “downsampling enforcement” in SR-CNNs is proposed. A differentiable operator is derived that, when applied as the final transfer function of a CNN, ensures the high-resolution outputs exactly reproduce the low-resolution inputs under 2D-average downsampling while improving performance of the SR schemes. The method is demonstrated across seven modern CNN-based SR schemes on several benchmark image datasets, and applications to weather radar, satellite imager, and climate model data are shown. The approach improves training time and performance while ensuring physical consistency between the super-resolved and low-resolution data. Significance Statement Recent advancements in using deep learning to increase the resolution of images have substantial potential across the many scientific fields that use images and image-like data. Most image super-resolution research has focused on the visual quality of outputs, however, and is not necessarily well suited for use with scientific data where known physics constraints may need to be enforced. Here, we introduce a method to modify existing deep neural network architectures so that they strictly conserve physical quantities in the input field when “super resolving” scientific data and find that the method can improve performance across a wide range of datasets and neural networks. Integration of known physics and adherence to established physical constraints into deep neural networks will be a critical step before their potential can be fully realized in the physical sciences.

54 ENVIRONMENTAL SCIENCES↗

Fast GPU 3D diffeomorphic image registration

3D image registration is one of the most fundamental and computationally expensive operations in medical image analysis. Here, we present a mixed-precision, Gauss–Newton–Krylov solver for diffeomorphic registration of two images. Our work extends the publicly available CLAIRE library to GPU architectures. Despite the importance of image registration, only a few implementations of large deformation diffeomorphic registration packages support GPUs. Our contributions are new algorithms to significantly reduce the run time of the two main computational kernels in CLAIRE: calculation of derivatives and scattered-data interpolation. Additionally, we deploy (i) highly-optimized, mixed-precision GPU-kernels for the evaluation of scattered-data interpolation, (ii) replace Fast-Fourier-Transform (FFT)-based first-order derivatives with optimized 8th-order finite differences, and (iii) compare with state-of-the-art CPU and GPU implementations. As a highlight, we demonstrate that we can register clinical images in less than 6 s on a single NVIDIA Tesla V100. This amounts to over 20 speed-up over the current version of CLAIRE and over 30 speed-up over existing GPU implementations.

97 MATHEMATICS AND COMPUTING↗

Toward Large-Scale Image Segmentation on Summit

Semantic segmentation of images is an important computer vision task that emerges in a variety of application domains such as medical imaging, robotic vision and autonomous vehicles to name a few. While these domain-specific image analysis tasks involve relatively small image sizes (~ 10 2 × 10 2 ), there are many applications that need to train machine learning models on image data with extents that are orders of magnitude larger (~10 4 × 10 4 ). Training deep neural network (DNN) models on large extent images is extremely memory-intensive and often exceeds the memory limitations of a single graphical processing unit, a hardware accelerator of choice for computer vision workloads. Here, an efficient, sample parallel approach to train U-Net models on large extent image data sets is presented. Its advantages and limitations are analyzed and near-linear strong-scaling speedup demonstrated on 256 nodes (1536 GPUs) of the Summit supercomputer. Using a single node of the Summit supercomputer, an early evaluation of a recently released model parallel framework called GPipe is demonstrated to deliver ~ 2X speedup in executing a U-Net model with an order of magnitude larger number of trainable parameters than reported before. Performance bottlenecks for pipelined training of U-Net models are identified and mitigation strategies to improve the speedups are discussed. Together, these results open up the possibility of combining both approaches into a unified scalable pipelined and data parallel algorithm to efficiently train U-Net models with very large receptive fields on data sets of ultra-large extent images.

Seal, Sudip↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustics at the nanoscale (nanoacoustics): A comprehensive literature review. Part II: Nanoacoustics for biomedical imaging and therapy

We report in the past decade, acoustics at the nanoscale (i.e., nanoacoustics) has evolved rapidly with continuous and substantial expansion of capabilities and refinement of techniques. Motivated by research innovations in the last decade, for the first time, recent advancements of acoustics-associated nanomaterials/nanostructures and nanodevices for different applications are outlined in this comprehensive review, which is written in two parts. As part II of this two-part review, this paper concentrates on nanoacoustics in biomedical imaging and therapy applications, including molecular ultrasound imaging, photoacoustic imaging, ultrasound-mediated drug delivery and therapy, and photoacoustic drug delivery and therapy. Firstly, the recent developments of nanosized ultrasound and photoacoustic contrast agents as well as their various imaging applications are examined. Secondly, different types of nanomaterials/nanostructures as nanocarriers for ultrasound and photoacoustic therapies are discussed. Finally, a discussion of challenges and future research directions are provided for nanoacoustics in medical imaging and therapy.

47 OTHER INSTRUMENTATION↗

Breast Cancer Imaging and Characterization

Researchers at Los Alamos National Laboratory are developing a suite of ultrasound-waveform tomography and super-resolution ultrasound imaging technology that, while investigational at this time, may be able to provide significantly improved image resolution and characterization of early-stage cancers in a non-invasive and cost-effective manner. Breast cancer is the most frequently diagnosed cancer in U.S. women. Although current medical imaging technologies have improved, false positive rates for mammograms still range 50-60% after 10 yearly mammograms. This innovative ultrasound-imaging technology is patented and copyright protected. It has great potential to differentiate between cancerous and healthy tissue without the negative side effects of mammography. We are seeking a commercialization partner to license these technologies or participate in a Cooperative Research and Development Agreement (CRADA) to further develop a practical suite of products for commercial purposes, and where applicable seek any necessary FDA authorization of the technology.

59 BASIC BIOLOGICAL SCIENCES↗