Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mechanical Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

TEAMER: Experimental performance characterization of a shrouded axial-flow turbine

Sitkana has developed a shrouded hydrokinetic turbine with a modular, low-cost design that can be scaled to meet the needs of remote communities. With technical support from the University of Washington, Sitkana sought to experimentally characterize the mechanical power and structural loads of various 1:3.3 scale rotor geometries. In all, 11 different rotor geometries were characterized with variations in height-to-diameter ratio, blade number, and blade type (foiled versus flat). All tests were conducted in Reynolds-independent flow conditions in the Alice C. Tyler Flume at the University of Washington. Results allow Sitkana to (1) refine the optimal rotor geometry, (2) validate numerical models, and (3) predict power output for a full-scale system. This project is part of the TEAMER RFTS 8 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Tau and Membranes: Interactions That Promote Folding and Condensation

Tau misfolding and assembly is linked to a number of neurodegenerative diseases collectively described as tauopathies, including Alzheimer’s disease (AD) and Parkinson’s disease. Anionic cellular membranes, such as the cytosolic leaflet of the plasma membrane, are sites that concentrate and neutralize tau, primarily due to electrostatic interactions with tau’s microtubule binding repeat domain (RD). In addition to electrostatic interactions with lipids, tau also has interactions with membrane proteins, which are important for tau’s cellular functions. Tau also interacts with lipid tails to facilitate direct translocation across the membrane and can form stable protein-lipid complexes involved in cell-to-cell transport. Concentrated tau monomers at the membrane surface can form reversible condensates, change secondary structures, and induce oligomers, which may eventually undergo irreversible crosslinking and fibril formation. These β-sheet rich tau structures are capable of disrupting membrane organization and are toxic in cell-based assays. Given the evidence for relevant membrane-based tau assembly, we review the emerging hypothesis that polyanionic membranes may serve as a site for phase-separated tau condensation. Membrane-mediated phase separation may have important implications for regulating tau folding/misfolding, and may be a powerful mechanism to spatially direct tau for native membrane-mediated functions.

59 BASIC BIOLOGICAL SCIENCES↗

Performance and Wake Characterization of a Model Hydrokinetic Turbine: The Reference Model 1 (RM1) Dual Rotor Tidal Energy Converter

The mechanical power and wake flow field of a 1:40 scale model of the US Department of Energy’s Reference Model 1 (RM1) dual rotor tidal energy converter are characterized in an open-channel flume to evaluate power performance and wake flow recovery. The NACA-63(4)-24 hydrofoil profile in the original RM1 design is replaced with a NACA-4415 profile to minimize the Reynolds dependency of lift and drag characteristics at the test chord Reynolds number. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADV) aligned with each rotor centerline and the midpoint between the rotor axes. Flow conditions for each case were controlled to maintain a hub height velocity, uhub= 1.04 ms−1, a flow Reynolds number, ReD= 4.4 × 105, and a blade chord length Reynolds number, Rec= 3.1 × 105. Performance was measured for a range of tip-speed ratios by varying rotor angular velocity. Peak power coefficients, CP= 0.48 (right rotor) and CP= 0.43 (left rotor), were observed at a tip speed ratio, λ= 5.1. Vertical velocity profiles collected in the wake of each rotor between 1 and 10 rotor diameters are used to estimate the turbulent flow recovery in the wake, as well as the interaction of the counter-rotating rotor wakes. The observed performance characteristics of the dual rotor configuration in the present study are found to be similar to those for single rotor investigations in other studies. Similarities between dual and single rotor far-wake characteristics are also observed.

30 DIRECT ENERGY CONVERSION↗

A Multiwavelength Study of the Cool Core Cluster MACS J1447.4+0827

Clusters of galaxies are outstanding laboratories for understanding the physics of supermassive black hole (SMBH) feedback. Here we present the first Chandra, Karl G. Jansky Very Large Array, and Hubble Space Telescope analysis of MACS J1447.4+0827 (z = 0.3755), one of the strongest cool core clusters known, in which extreme feedback from its central SMBH is needed to prevent the hot intracluster gas from cooling. Using this multiwavelength approach, including 70 ks of Chandra X-ray observations, we detect the presence of collimated jetted outflows that coincide with a southern and a northern X-ray cavity. The total mechanical power associated with these outflows (P {sub cav} ≈ 6 × 10{sup 44} erg s{sup −1}) is roughly consistent with the energy required to prevent catastrophic cooling of the hot intracluster gas (L {sub cool} = 1.71 ± 0.01 × 10{sup 45} erg s{sup −1} for t {sub cool} = 7.7 Gyr), implying that powerful SMBH feedback was in place several Gyr ago in MACS J1447.7+0827. In addition, we detect the presence of a radio minihalo that extends over 300 kpc in diameter (P {sub 1.4GHz} = 3.0 ± 0.3 × 10{sup 24} W Hz{sup −1}). The X-ray observations also reveal an ∼20 kpc plumelike structure that coincides with optical dusty filaments that surround the central galaxy. Overall, this study demonstrates that the various physical phenomena occurring in the most nearby clusters of galaxies are also occurring in their more distant analogs.

79 ASTRONOMY AND ASTROPHYSICS↗

Waste heat recovery system and control

A waste heat recovery (WHR) system that can be utilized in internal combustion engine systems includes at least two circuits, one having a low pressure working fluid and another having a high pressure working fluid. Each circuit can include heat exchangers to allow the working fluid to absorb heat form one or more heat source fluids associated with the engine. The system can also include an expander configured to receive the working fluid from the at least two circuits, and generating mechanical power. The system also can include a condenser, a sub cooler, and at least one working fluid pump to pump the working fluid in the at least two circuits. The cooling system also includes a controller that can receive temperature and pressure values from various locations in the WHR system and control at least the flow rates of the working fluids in the at least two circuits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Entanglement Requirements for Coherent Enhancement in Detectors

Coherent enhancement is a powerful mechanism for improving the sensitivity of a wide range of detectors, but its practical use is often limited by the difficulty of preparing the required quantum states. We show that this difficulty has a fundamental origin: coherent enhancement of a signal interacting with a detector is quantitatively constrained by entanglement. We prove general bounds on how the strength of coherent effects can scale with system size, as a function of the single-mode entanglement entropy of the detector. These bounds smoothly interpolate between the incoherent and fully coherent regimes, and apply both to parameter-estimation problems and to scattering processes. We discuss these results from two complementary perspectives: First, they appear as bounds on the quantum Fisher information of many-body states, which translate directly into limits on parameter sensitivity via the quantum Cramér-Rao bound. Second, they can be interpreted as limits on a class of scattering cross sections, leading to predictions for how minimum detectable interaction strengths scale with target size. Together, these results provide a unified view of coherent enhancement in metrology and scattering experiments, and motivate the development of new techniques for generating entangled detector states.

Bogorad, Zachary [Fermilab] (ORCID:000000019913647↗

Characterization of Recovery Human Action Mechanisms in Nuclear Power Plants

Recovery human action is defined as the action that prevents deviant conditions from producing unwanted effects. Analyzing recovery actions has been a critical part in human reliability analysis (HRA). However, there are a couple of limitations to treat recovery actions only depending on the current HRA methods. Representatively, the existing recovery analysis does not specifically consider recovery actions as are occurred in actual nuclear power plants (NPPs). The overall goal of this study aims to develop a novel recovery analysis method to account for human action recoveries in context of scenarios as well as complement the limitations of existing recovery analysis. In this paper, the recovery analysis in current HRA methods and their challenges are introduced. A strategy to achieve the goal is introduced with a modified recovery definition. Then, how we have researched the approach will be introduced in the paper.

99 GENERAL AND MISCELLANEOUS↗

Comparative Analysis of Pendulum and Flywheel Power Take-Off Mechanisms for Wave Energy Conversion

Here, this study compares three power-take-off (PTO) mechanisms for wave energy converters—a flywheel -type pitch resonator and two pendulum variants (normal and inverted)—all designed to fit within a fixed envelope. Performance is assessed via linear frequency-domain models and bi-conjugate impedance matching under a representative sea state. The inverted-pendulum PTO achieves 27.9% of the incident wave energy, versus 16.5% for the normal pendulum and 4.2% for the flywheel—that is, 6.6 × and 3.9 × improvements, respectively. These gains arise because pendulum-based systems generate higher torque for a given buoy motion and maintain impedance matching across a wider frequency band. Parametric studies of mass, pendulum arm length, spring stiffness, generator friction, and motor constant quantify the impact of key design choices on power output. By locating the pendulum pivot near the buoy's center of gravity and positioning the center of rotation below the COG, surge–pitch coupling is improved and energy transfer is further boosted.

Keow, Alicia Li Jen [Sandia National Laboratories ↗

The relation between accretion rate and jet power in early-type galaxies with thermally unstable hot atmospheres

ABSTRACT We use Chandra X-ray data and Very Large Array radio observations for a sample of 20 nearby, massive, X-ray bright, early-type galaxies to investigate the relation between the Bondi accretion rates and the mechanical jet powers. We find a strong correlation ($\rho = 0.96^{+0.03}_{-0.09}$; BF10 > 100) between the Bondi accretion power, PBondi, and the mechanical jet power, Pjet, for a subsample of 14 galaxies, which also host cool H α+[N ii] line emitting gas and thus likely have thermally unstable atmospheres. The relation between the Bondi accretion power and the mechanical jet power for this subsample is well described by a power-law model $\log \frac{P_{\mathrm{Bondi}}}{{10^{43} \, \mathrm{erg \, s^{-1}}}} = \alpha + \beta \log \frac{P_{\mathrm{jet}}}{{10^{43} \, \mathrm{erg \, s^{-1}}}}$, where α = 1.10 ± 0.25 and β = 1.10 ± 0.24 with an intrinsic scatter $\sigma = 0.08^{+0.14}_{-0.06}$ dex. The results indicate that in all galaxies with thermally unstable atmospheres the cooling atmospheric gas feeds the central black holes at a similar jet-to-Bondi power ratio. For the full sample of 20 galaxies, the correlation is weaker and in a subset of galaxies with no signs of H α+[N ii] emission, we see a hint for a systematically lower jet-to-Bondi power ratio. We also investigate the dependence of jet power on individual quantities in the Bondi formula such as the supermassive black hole mass (M•) and the specific entropy of the gas (K) at the Bondi radius. For the subsample of H α+[N ii] emitting galaxies, we find a very tight correlation of Pjet with M• ($\rho = 0.91^{+0.06}_{-0.11}$; BF10 > 100) and, although poorly constrained, a hint of an anticorrelation for Pjet and K ($\rho = -0.47^{+0.60}_{-0.37}$; BF10 = 1.1).

79 ASTRONOMY AND ASTROPHYSICS↗

Using Demanded Power and RDE Aggressiveness Metrics to Analyze the Impact of CACC Aggressiveness on Heavy Duty Platooning Power Consumption

Presently, a main mobility sector objective is to reduce its impact on the global greenhouse gas emissions. While there are many techniques being explored, a promising approach to improve fuel economy is to reduce the required energy by using slipstream effects. This study analyzes the demanded engine power and mechanical energy used by heavy-duty trucks during platooning and non-platooning operation to determine the aerodynamic benefits of the slipstream. A series of platooning tests utilizing class 8 semi-trucks platooning via Cooperative Adaptive Cruise Control (CACC) are performed. Comparing the demanded engine power and mechanical energy used reveals the benefits of platooning on the aerodynamic drag while disregarding any potential negative side effects on the engine. However, energy savings were lower than expected in some cases. It was hypothesized that the CACC may have amplified transient platooning events relative to the individual truck baseline results, hampering the potential energy savings. Therefore, the impact of the controller on the observed driving style was analyzed in detail. In order to quantify the transient operational characteristics of the experimental trials, metrics from the European Real Driving Emissions (RDE) legislation were modified to serve as metrics of aggressiveness during platooning. The metrics (v · apos)95 and Relative Positive Acceleration (RPA) were calculated for platooning and non-platooning runs. These results indicate that the CACC induces small acceleration events during platooning to retain the commanded longitudinal separation between vehicles. These small acceleration events increase following vehicle aggressiveness during platooning and prevent the following vehicles from obtaining maximum energy savings. Moreover, a correlation between the RDE metric (v · apos)95 and energy savings is developed. Hence, this work establishes the ability of RDE metrics to assess CACC impacts on platoon energy savings.

European Real Driving Emissions, RDE, greenhouse g↗

Learning model combining convolutional deep neural network with a self-attention mechanism for AC optimal power flow

Alternating current optimal power flow (OPF) analysis is critical for efficient and reliable operation of power systems. For large systems or repetitive computations, the traditional methods such as the direct and gradient methods, or non-traditional methods, such as the genetic algorithm and simulating annealing, are time-consuming and unsuitable for real-time computing. The work in this paper proposes a novel framework to obtain the optimal solution of power flow in real-time using a combination of convolutional neural networks and a self-attention mechanism. All parameters of the power networks are rearranged in an image-like shape of a multi-channel image where each channel is a two-dimensional matrix. The proposed approach is adaptive with every input size of power systems as well as frequent variations of network topologies without intervention to the framework core. The encompassment of all power system contexts in which all parameters of internal elements, generation costs, and topology information are included, contributes to the higher accuracy of inference compared to other current machine-learning-based OPF-solving methods. Besides, the proposed framework established on ubiquitous platforms is effortlessly integrated into current infrastructures of power systems, and the great efficiency along with the computation speed may serve as a critical point for practical implications, such as enabling faster decision-making during real-time operations, predicting system contingencies, and remedial actions based on an offline pre-trained model. Furthermore, this supervised learning process is applied to the dataset of four case studies of meshed power systems: the IEEE 5-bus system (IEEE-5), the IEEE 30-bus system (IEEE-30), the IEEE 39-bus system (IEEE-39), and the IEEE 57-bus system (IEEE-57) to prove the efficacy of the proposed method.

42 ENGINEERING↗

Circuit Modelling of the Mechanical-Motion-Rectifier for Electrical Simulation of Ocean Wave Power Take-off

As is the case with several other mechanical power takeoffs (PTOs), the mechanical-motion-rectifier (MMR) based PTO consists of components such as one-way clutches, gears, a ball screw, mechanical couplings, and a generator. Equivalent circuit models have been created in this paper to describe the dry frictions, viscous damping, and mechanical compliances in these components, so the non-ideal efficiency and nonlinear force of the PTO can be predicted in electrical simulations by integrating these sub-circuit models. The circuit model is simplified, and its parameters are categorized as dc and ac unknowns. The dc and ac tests on the PTO are performed sequentially to extract two sets of parameters through linear regression or nonlinear curve fitting. Then, the model is validated through its prediction capability over 25 test conditions on input forces, output voltages, and efficiencies, with correlation coefficients of 0.9, 0.98, and 0.981, respectively.

42 ENGINEERING↗

Dynamic characterization and performance evaluation of a 10-kW power take-off with mechanical motion rectifier for wave energy conversion

The power take-off (PTO) is a key component for wave energy converters. In this paper, a compact PTO with mechanical motion rectification rated at 10 kW is designed and prototyped, and characterized. A piecewise nonlinear dynamic model is established to describe its unique dynamic property. A linear hydraulic actuator is adopted in lab testing to drive the prototype and the unknown parameters of the dynamic model are identified. Further verification shows that the model can predict the dynamic performance of the PTO well. The test results show that the mechanical motion rectifier-based PTO can achieve overall energy transfer efficiency as high as 65% in regular waves even when the generator is working below the rated electric load and speed. In the irregular wave test, the PTO achieved the overall energy transfer efficiency of 54%, and the peak-to-average ratio acquired during the test is 12.5.

16 TIDAL AND WAVE POWER↗

Dynamic Characterization and Performance Evaluation of a 10-kw Power Take-Off with Mechanical Motion Rectifier for Wave Energy Conversion

The power take-off (PTO) is a key component for wave energy converters (WECs). The dynamic properties of the PTO influence the response of the WEC and should be considered when designing the WEC and not oversimplified. In addition, the efficiency as well as the reliability can play an important role on whether the PTO can be suitable for real-world applications. In this paper, a novel compact PTO rated at 10 kW is designed and prototyped, and a comprehensive nonlinear dynamic model is established for the PTO. Through bench testing, the unknown parameters of the dynamic model are characterized and determined. Further verification shows that the model can predict the dynamic performance of the PTO well. In addition, the test results show that the mechanical motion rectifier PTO can achieve good energy transfer efficiency, especially for low-load and low-speed conditions.

bench test↗

Effects of Encapsulant Properties on the Thermo-Mechanical Reliability of Double-Side Cooled Power Modules for Traction Inverters

Double-side cooled power modules are being developed for next-generation traction inverters due to their better heat extraction, lower profile, and lower parasitic inductances. However, due to their rigid structure, they cause reliability concerns arising from high thermo-mechanical stresses at the interconnection joints in the module. In this work, a materials-based approach using rigid encapsulants is presented for reducing thermo-mechanical fatigue. Finite-element thermo- mechanical simulations were performed to examine the effects of the elastic modulus and coefficient of thermal expansion of epoxy- based encapsulants on the bond deformation inside a double-side cooled power module. It was found that a rigid encapsulant with a high modulus of 6.0 GPa or above and a coefficient of thermal expansion around 20 ppm/oC would improve the thermo- mechanical reliability of double-side cooled power modules by decreasing the permanent bond deformation inside the modules by 50-60%.

ADVANCED PROPULSION SYSTEMS↗

Electro-Thermo-Mechanical (ETM) Study on Submarine Dynamic Power Cables (SDPC) for Offshore Wind Transmission

Understanding the failure mechanisms of submarine dynamic power cables (SDPC) is critical for innovative design to meet the 2035 cost reduction target of U.S. DOE Floating Offshore Wind Shot. This is important because the current design suffers a significant failure rate in the field. This project conducted a systematic electro-thermo-mechanical (ETM) experimental study on the power cores extracted from a 15kV power cable with three cores of copper conductor, ethylene propylene rubber (EPR) insulation, and continuously corrugated welded aluminum armor (CCWA). An ETM testing system was developed by integrating a high voltage (HV) amplifier, two ceramic heaters, and a rod-plate transverse compression setup into a mechanical testing machine. Increasing temperature from room temperature (RT, 22 degree C) to 90 degree C resulted in the 67% decrease in the failure mechanical load as defined by the dielectric breakdown. Under creep mechanical loading, the dielectric breakdown time was decreased by 70% for a given mechanical load when the specimen temperature increased from RT to 90oC. The failure strain in both monotonic and creep mechanical loading modes was related to the maximum mechanical load applied. Although the dielectric breakdown occurred in the ETM test, the post-test measurement revealed an impressive recovery of electric resistance. The failure analysis on cross section of tested specimens indicated a sizable gap across insulation layer near the area between copper conductor and loading rod, which apparently resulted from online dielectric failure and offline elastic recovery of components including conductor and insulation layer.

17 WIND ENERGY↗

Undulating transducer for energy harnessing and propulsion apparatuses, methods and systems

Embodiments disclosed may serve the function of a pump, a generator, or a propulsion system. Two flexible fins are coupled via their longitudinal inner edges to fin coupling modules. An external fluid flow causes traveling fin undulations. The angle of the fins relative to each other changes as undulations travel along the fins which can be translated through the fin coupling modules into mechanical work, powered by the external fluid flow. The mechanical work of the fin coupling modules may be the cyclical extension and contraction of pistons or bellows incorporated into the fin coupling modules, which may draw ambient fluid during their extension cycles and compress fluid during their contraction cycles to create a pump. The pistons or bellows may also be sealed from ambient fluid but connected through conduits through which contained fluid is exchanged in a continuous circulation of fluid to power a pump or a turbine.

Filardo, Benjamin Pietro↗

Thermal and Mechanical Design of a High-Voltage Power Electronics Package: Preprint

Thermal and mechanical design aspects of a power electronic package with 5-kV GaN devices are presented. Through finite element analyses, the impact of different cooling configurations and device location on the thermal performance and reliability of the package was investigated. It was found that placing the devices closer to the direct-bond-copper substrate as opposed to a centered approach in the proposed double-sided-cooling configuration resulted in improved heat dissipation. This approach also reduced the total number of attachment layers, thereby likely improving the reliability of the package. Furthermore, simulations revealed that the device location had a negligible impact on the thermomechanical behavior of the attachment layers, as they are more prone to the local coefficient of thermal expansion mismatch.

27 ARPA - Advanced Research Projects Agency-Energy↗