Measurement of Beam Energy in the Fermilab's Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

Measurement of stability diagrams in the IOTA ring at Fermilab

Nonlinear focusing elements can enhance the stability of particle beams in high-energy colliders through Landau Damping, by means of the tune spread which is introduced. Here we discuss an experiment at Fermilab's Integrable Optics Test Accelerator (IOTA) which investigates the influence of nonlinear focusing elements, such as octupoles, on the beam’s transverse stability. In this experiment, we employ an anti-damper, an active transverse feedback system, as a controlled mechanism to induce coherent beam instability. By utilizing the anti-damper we can examine the impact of a nonlinear focusing element on the beam's transverse stability. The stability diagram, a tool used to determine the system's stability, is measured using a recently demonstrated method at the LHC. The experiment at IOTA adds insight towards this stability diagram measurement method by supplying a reduced machine impedance to investigate the machine impedance’s effect on the stability diagram, as well as by aiming to map out the full stability diagram by using a large phase range of the anti-damper. From this experiment in IOTA, we present the first results of stability diagram analysis with varying octupole currents.

43 PARTICLE ACCELERATORS↗

Development of an accelerated creep testing technique via multi-specimen loading

This report summarizes a research effort undertaken by Argonne National Laboratory to accelerate the development of creep data package for code qualification. The goal is to explore new creep testing techniques to shorten the overall time needed to generate high-quality data to support an ASME code case on laser powder bed fusion 316H stainless steel. Progresses on the design and implementation of a 3-specimen load train and an innovative strain measurement method with direct potential current drop (DCPD) technique are reported.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Flexible Field Mapping System for Accelerator Magnets

Magnetic field mapping is a fundamental magnetic measurement method that typically uses Hall and NMR sensors. In magnet measurement facilities, such systems are likely used in various configurations suitable for a specific task at hand. To address this diversity, the authors developed a flexible field mapping system capable of being configured and tailored to each particular measurement case. The system needs to address the variability introduced by differences in sensors and their readout systems, probe positioning systems, power supply systems and in required mapping geometry (mapping space and grid, measurement steps and sequences). Although the discussed field mapping systems range from a self-propelled, multi-sensor mapper of a large detector magnet to a single 3D Hall sensor system to scan a small permanent magnet, they were all built with the same core mapping system. The variability present in field mapping systems and the measurement system architecture addressing this variability, as well as examples of several field mapping systems built in this architecture are presented.

43 PARTICLE ACCELERATORS↗

Measuring thermal profiles in high explosives using neural networks

We present a new method for calculating the temperature profile of high explosive (HE) material using a Convolutional Neural Network (CNN). To train/test the CNN, we have developed a hybrid experiment/simulation method for collecting acoustic and temperature data. We experimentally heat cylindrical containers of HE material until detonation/deflagration, where we continuously measure the acoustic bursts through the HE using multiple acoustic transducers lined around the exterior container circumference. However, measuring the temperature profile in the HE in an experiment would require inserting a large number of thermal probes, which would disrupt the heating process. Thus, we use two thermal probes, one at the HE center and one at the wall. We then use numerical simulation of the heating process to calculate the temperature distribution and correct the simulated temperatures based on the experimental center and wall temperatures. We calculate temperature errors on the order of 15 °C, which is ~12% of the range of temperatures in the experiment. We also investigate how the algorithm’s accuracy is affected by the number of acoustic receivers used to collect each measurement and the resolution of the temperature prediction. This work provides a means of assessing the safety status of HE material, which cannot be achieved using existing temperature measurement methods. In addition, it has implications for a range of other applications where internal temperature profile measurements would provide critical information. These applications include detecting chemical reactions, observing thermodynamic processes such as combustion, monitoring metal or plastic casting, determining the energy density in thermal storage capsules, and identifying abnormal battery operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Energy Muon Beam Diagnostics - Scintillating Fiber Profile Monitor (SFPM)

The MeV Test Area (MTA) houses the 400 MeV H^− Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.

Leith, Justin↗

Nuclear Material Control & Accounting for Pebble Bed Reactors (FY 2023 Summary Report)

This report discusses the work done under the US Department of Energy NE-5 Advanced Reactor Safeguards and Security Program during FY 2023. It provides a summary of material control and accounting (MC&A) for pebble bed reactors (PBRs) and addresses some of the main challenges with current PBR MC&A approaches that will inform safeguards and security by design efforts. The efforts to date have focused on tristructural isotropic (TRISO) pebble fuel material accounting and control including working with partners in industry, loss and production of nuclear material as part of reactor operations, burnup modeling and measurements, uncertainty quantifications for such modeling and measurements, statistical approaches needed, and measurement methods. The unique fuel management and utilization in a PBR, where the fuel in spherical form is introduced and circulates through the reactor, poses special challenges for MC&A. This contrasts with traditional water-cooled reactors in which the fuel is contained in large assemblies and can be easily identified and counted. Even online fueled reactors, such as the CANDU reactors (none of which operate in the United States), are significantly different because the fuel is still contained in relatively large assemblies, is uniquely identified, and the number of assemblies that pass through the core on an annual basis is much fewer than the hundreds of thousands that circulate in a PBR, none of which are uniquely identified. Additionally, the nature of the TRISO fuel results in very low heavy metal loading with each pebble containing less than 10 g of uranium and on the order of less than 1 g of fissile material. This low fuel density and the robustness of the TRISO particles are major features of the TRISO fuel from a safety basis as each TRISO particle and pebble acts as a containment for the nuclear material and fission products during normal and accident conditions. This also results in very low plutonium loading per pebble during normal operations, which is on the order of 0.1 g at full burnup. A major feature of PBRs is that they will allow for significantly higher burnup, on the order of 160 GWd/THM compared to the burnup of traditional LWRs, which is on the order of 45 GWd/THM. This is achieved by monitoring the pebbles as they circulate through the reactor and allowing them to be reintroduced into the core until the desired burnup is achieved and they are removed from the reactor and enter the spent fuel storage areas.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Specifications of Cladding Diameter Measurements Conducted at AGHCF

Fuel element diameter data was collected on-site at the Alpha-Gamma Hot Cell Facility (AGHCF) before and after out-of-pile furnace transient tests of fuel elements. Available data records have been collected and preserved in the Out-of-Pile Transient Database (OPTD). This data is used to determine the transient-induced changes in fuel element diameter, or cladding strain, for the Whole Pin Furnace (WPF) tests. Fuel element diameter was measured by contact profilometry along the length of the fuel pin at specified rotational orientations and/or by a manually operated micrometer at several discrete axial locations along the pin. The Alpha-Gamma Hot Cell Facility Operations Manual details the way the facility operated, organizational and oversight responsibilities, and procedures for examination of samples. The working version of the manual at the time of the whole pin furnace tests and the test pin examinations is Doc. No. IPS-2-00-00, dated June 1989. This specification was developed using the operations manual and recovered measurement records in consultation with subject matter experts (SMEs). The measurement methods, format of the available post-test examination (PTE) data, and recommended methods for use and interpretation of that data are summarized. Section 2 describes the available diameter measurement data for the WPF tests with guidance for interpretation and usage, and Section 3 describes the instrument measurement procedures and calibration methods.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Beginner's Guide to Power and Energy Measurement and Estimation for Computing and Machine Learning

Concerns about the environmental footprint of machine learning are increasing. While studies of energy use and emissions of ML models are a growing subfield, most ML researchers and developers still do not incorporate energy measurement as part of their work practices. While measuring energy is a crucial step towards reducing carbon footprint, it is also not straightforward. This paper introduces the main considerations necessary for making sound use of energy measurement tools and interpreting energy estimates, including the use of at-the-wall versus on-device measurements, sampling strategies and best practices, common sources of error, and proxy measures. It also contains practical tips and real-world scenarios that illustrate how these considerations come into play. It concludes with a call to action for improving the state of the art of measurement methods and standards for facilitating robust comparisons between diverse hardware and software environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electronics Free Laser Sensing Technology for Minerals and Technology Elements

This presentation presents an electronics free laser sensing technique and its ongoing and potential applications. A laser-based technique, popularly known as laser-induced breakdown spectroscopy has been prototyped for the determination of high-tech elements including rare earth elements and other elements in solid as well as aqueous sources. All optical unit without any electronics has been designed in such a way that it can be installed in the source environment and connected to other required components for controlling and data acquisition from the workstation. Measurement methods and results obtained for selected elemental species and overall performance of the developed prototype will be presented.

HCM Sensor↗

Variation in surface properties as error sources in dynamic temperature measurements

Most temperature measurement methods rely upon the assumption of a single uniform source as part of the analysis in inferring an observed temperature T from the surface of a material. This is true for the radiometric and spectroscopic methods we rely upon in shock physics. However, there are obvious cases where this is a poor assumption that can cause large errors in analysis, such as the measurement of emission from a surface composed of more than one material, such as a rusted surface of Fe and Fe 2 O 3 , or a multi-material surface that could be produced through alloying methods (e.g., mokume gane) or 3D printing. Here we perform an initial examination of the effects of varied surface properties upon the analysis using idealized test data to constrain when we may have better confidence in the resulting calculations. We also examine the structures of the fits to test whether, in principle, comparing the fit with ideal gray bodies would reveal such a structure and enable the researcher to identify when a two-temperature fitting model should be used instead of a single- T model or a wavelength-dependent emissivity model.

36 MATERIALS SCIENCE↗

Mechanical Characterization of the NIF Ignition Target TMPSA Bonding Flexure

The Thermo-Mechanical Package Sub-Assembly (TMPSA) provides a critical mechanical, thermal, and electrical interface between a silicon arm and a TMP aluminum can in a NIF ignition target. During assembly, sixteen silicon pads are bonded to the aluminum using a fixture that positions the components and applies a repeatable prescribed displacement through a compliant flexure. The flexure converts fixture interference into displacement and reaction force. Because bondline thickness variation must be maintained within +/-4 µm, consistent flexure behavior is important to the assembly process. With a recent string of TMPSAs exhibiting low bond strength, the flexures were inspected. Despite being manufactured to the same specifications, flexures were found to exhibit variation in measured stiffness. Additionally, the measured stiffness values did not always follow the presumed beam mechanics model. This work addresses two questions: whether the bonding fixture is working as intended, and whether the previously made stiffness measurements are accurate representations of the use case. The flexures are analyzed using Euler-Bernoulli beam theory, measured beam dimensions, finite element analysis, and tolerance stack-up calculations. The analysis shows that the fixed-guided beam mechanics model appropriately represents the flexure during TMPSA bonding, but the chisel-tip stiffness measurement method introduces a deformation to the inner ring of the flexure that is not represented during use. The measured stiffness values should therefore be interpreted as test-condition stiffness values rather than direct measurements of operational flexure stiffness. The discrepancy is therefore attributed primarily to the measurement boundary condition rather than to failure of the fixed-guided beam model. Recommendations are provided for GD&T, dimensional inspection, and a representative stiffness testing method to better control bondline variation.

42 ENGINEERING↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

Methods for Incorporating Model Uncertainty into Exoplanet Atmospheric Analysis

A key goal of exoplanet spectroscopy is to measure atmospheric properties, such as abundances of chemical species, in order to connect them to our understanding of atmospheric physics and planet formation. In this new era of high-quality JWST data, it is paramount that these measurement methods are robust. When comparing atmospheric models to observations, multiple candidate models may produce reasonable fits to the data. Typically, conclusions are reached by selecting the best-performing model according to some metric. This ignores model uncertainty in favor of specific model assumptions, potentially leading to measured atmospheric properties that are overconfident and/or incorrect. In this paper, we compare three ensemble methods for addressing model uncertainty by combining posterior distributions from multiple analyses: Bayesian model averaging, a variant of Bayesian model averaging using leave-one-out predictive densities, and stacking of predictive distributions. We demonstrate these methods by fitting the Hubble Space Telescope (HST) + Spitzer transmission spectrum of the hot Jupiter HD 209458b using models with different cloud and haze prescriptions. All of our ensemble methods lead to uncertainties on retrieved parameters that are larger but more realistic and consistent with physical and chemical expectations. Since they have not typically accounted for model uncertainty, uncertainties of retrieved parameters from HST spectra have likely been underreported. We recommend stacking as the most robust model combination method. Our methods can be used to combine results from independent retrieval codes and from different models within one code. They are also widely applicable to other exoplanet analysis processes, such as combining results from different data reductions.

79 ASTRONOMY AND ASTROPHYSICS↗

Summertime methane and carbon dioxide emission rates and associated variables from a national-scale survey of 146 reservoirs in the United States, 2016-2023

Reservoirs are globally important sources of greenhouse gases, but the magnitude of their emissions is highly uncertain. Here we present data for 146 reservoirs from two surveys of reservoir methane and carbon dioxide emissions, one at the regional scale in the midwestern United States and one at the national scale in the conterminous United States, plus data from one reservoir in Washington and another in Puerto Rico. At all reservoirs, ebullitive and diffusive emissions and basic physiochemistry were measured at 15-70 locations during one 22 to 64-hour period during the summers of 2016-2023, with four reservoirs revisited a second time. Concomitant water chemistry measurements were also made at an index site. The dataset is comprised of two geospatial files and seven .csv files containing greenhouse gas emissions, water chemistry, morphology, and other relevant data. These data comprise the largest multi-reservoir emissions dataset ever assembled using consistent measurement methods.

Beaulieu, Jake [University of Notre Dame, IN]↗

Systems and methods for dual comb spectroscopy

A frequency-measurement method uses a dual frequency-comb spectrometer as an optical wavemeter to measure the frequency of a reference laser that is used to frequency-stabilize the spectrometer. The method includes measuring a walking rate of center bursts in a sequence of interferograms recorded by the spectrometer, determining a number of teeth in each of a plurality of Nyquist windows formed by the dual frequency-comb spectrometer, and determining a Nyquist number of the one Nyquist window covering the laser frequency. The reference laser frequency can then be determined from the number of teeth in each Nyquist window, the Nyquist number, and the comb spacing of either one of the two frequency combs of the dual frequency-comb spectrometer. The reference laser frequency does not need to be measured with a separate wavemeter, or calibrated with respect to a known atomic or molecular transition.

Rieker, Gregory B.↗

Quantifying Burst Repeatability for Godiva IV

The minimum resolvable relative change in the neutron source emission of Godiva IV between bursts, i.e., burst repeatability, was quantified using a combination of activation monitors and a resistance temperature detector (RTD). Measurements support changes in the neutron source emission between bursts can be determined with a precision of 2.7%. The measurements were performed during a series of twelve Godiva IV bursts and were a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratories, and Pacific Northwest National Laboratory. Gold, iron, nickel, and sulfur activation monitors were positioned in a sample holder in the central cavity of Godiva IV for each burst. The RTD is part of the Godiva burst diagnostic system and is in a fixed location in the safety block of Godiva IV. It is used to determine the temperature rise of the burst, i.e., the difference between the maximum temperature recorded during the burst and the initial temperature prior to the burst. Differences in either the specific activity of the activation monitor reactions, or the temperature rise can be used to determine the relative change in the neutron source emission for separate bursts, but historic results have proven that each method is susceptible to various sources of biases which generally cannot be isolated using a single method. We address this issue by applying both measurement methods and analyzing the correlation between them. The results presented in this work will be used to support future experiments with Godiva IV at the National Criticality Experiments Research Center (NCERC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low Energy Muon Beam Diagnostics: Scintillating Fiber Profile Monitor

The MeV Test Area (MTA) houses the 400 MeV H- Beam at the end of the Linac and a secondary beamline of muons and pions created from hitting a Tungsten target. The MTA is in the Irradiation Test Area (ITA), where experiments involve studying the effects of radiation on materials in the MTA beam. There is a need for a retractable detector to monitor the secondary beam’s intensity and coarse profile. The SFPM was chosen when considering factors like ability to measure low rates and handle high intensities. The plan was to test different scintillating fibers & Silicon Photomultiplier (SiPM) models to figure out which combination gives the best signals, and gain familiarity with the detector assembly, operation, and data acquisition software before using with final detectors in beamline. The SiPM circuit has been tested with a LED pulser successfully. The immediate steps that follow will be to set the SiPM up on the monitor with three different types of optical fibers, use the Caen software to configure the best mode of data acquisition, and proceed with an offline source test using Strontium-90. Once the most efficient measurement method is clear, they will be ready for use in the beamline.