Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mars data sets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

From Lake to River: Documenting an Environmental Transition Across the Jura/Knockfarril Hill Members Boundary in the Glen Torridon Region of Gale Crater (Mars)

Between January 2019 and January 2021, the Mars Science Laboratory team explored the Glen Torridon (GT) region in Gale crater (Mars), known for its orbital detection of clay minerals. Mastcam, Mars Hand Lens Imager, and ChemCam data are used in an integrated sedimentological and geochemical study to characterize the Jura member of the upper Murray formation and the Knockfarril Hill member of the overlying Carolyn Shoemaker formation in northern GT. The studied strata show a progressive transition represented by interfingering beds of fine–grained, recessive mudstones of the Jura member and coarser–grained, cross–stratified sandstones attributed to the Knockfarril Hill member. Whereas the former are interpreted as lacustrine deposits, the latter are interpreted as predominantly fluvial deposits. The geochemical composition seen by the ChemCam instrument show K 2 O–rich mudstones (~1–2 wt.%) versus MgO–rich sandstones (>6 wt.%), relative to the average composition of the underlying Murray formation. We document consistent sedimentary and geochemical data sets showing that low–energy mudstones of the Jura member are associated with the K–rich endmember, and that high–energy cross–stratified sandstones of the Knockfarril Hill member are associated with the Mg–rich endmember, regardless of stratigraphic position. The Jura to Knockfarril Hill transition therefore marks a significant paleoenvironmental change, where a long–lived and comparatively quiescent lacustrine setting progressively changes into a more energetic fluvial setting, as a consequence of shoreline regression due to either increased sediment supply or lake–level drop.

58 GEOSCIENCES↗

Learning to Count Grave Sites for Cemetery Observation Models With Satellite Imagery

Understanding how people occupy open spaces is important for research in support of population modeling, policy, national security, emergency response, and sustainability. For the past decade, there has been an increase in research toward capturing and reporting population dynamics and patterns of life at the building level and in some open public spaces such as cemeteries and parks. This is done through observation models developed from local sociocultural information acquired at various spatiotemporal scales to inform night, day, and episodic population occupancy estimates (people/1000 sq ft). Sociocultural information for cemeteries and parks is scarcely available and often collected manually. The process is not only marred by inconsistencies but is laborious and time consuming. In this study, we leverage convolutional neural networks (CNNs) and satellite imagery to derive grave site counts as proxy variables to support scalable and accurate sociocultural data required in a population observation model. Through a hybrid workflow (weak localization plus regression model), we characterize a large scale automation process to counting of grave sites. We evaluate and demonstrate the efficacy of proposed workflow using out-of-data set large satellite imagery and establish its broader impact on cemetery observation models.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automated Algorithms for Band Gap Analysis from Optical Absorption Spectra

As high-throughput combinatorial experimental methods become more common, the technical challenge is shifting from producing materials to dealing with increasingly large datasets. One of the most important metrics to determine suitability of semiconductor materials for various applications is the band gap. This paper discusses automated algorithms for determining band gaps from optical absorption spectra. The algorithms are applied to a database of 34,313 optical absorption spectra, and selected results are compared to published theoretical and experimental band gap data from 16 materials sets. The best algorithm determines the band gaps with an accuracy of 0.37 eV for direct- and 0.93 eV for indirect band gaps for >20,000 spectra.

97 MATHEMATICS AND COMPUTING↗

The climate of HD 189733b from fourteen transits and eclipses measured by Spitzer

We present observations of six transits and six eclipses of the transiting planet system HD 189733 taken with the Spitzer Space Telescope IRAC camera at 8 microns, as well as a re-analysis of previously published data. We use several novel techniques in our data analysis, the most important of which is a new correction for the detector 'ramp' variation with a double-exponential function which performs better and is a better physical model for this detector variation. Our main scientific findings are: (1) an upper limit on the variability of the day-side planet flux of 2.7% (68% confidence); (2) the most precise set of transit times measured for a transiting planet, with an average accuracy of 3 seconds; (3) a lack of transit-timing variations, excluding the presence of second planets in this system above 20% of the mass of Mars in low-order mean-motion resonance at 95% confidence; (4) a confirmation of the planet's phase variation, finding the night side is 64% as bright as the day side, as well as an upper limit on the night-side variability of 17% (68% confidence); (5) a better correction for stellar variability at 8 micron causing the phase function to peak 3.5 hours before secondary eclipse, confirming that the advection and radiation timescales are comparable at the 8 micron photosphere; (6) variation in the depth of transit, which possibly implies variations in the surface brightness of the portion of the star occulted by the planet, posing a fundamental limit on non-simultaneous multi-wavelength transit absorption measurements of planet atmospheres; (7) a measurement of the infrared limb-darkening of the star, which is in good agreement with stellar atmosphere models; (8) an offset in the times of secondary eclipse of 69 seconds, which is mostly accounted for by a 31 second light travel time delay and 33 second delay due to the shift of ingress and egress by the planet hot spot; this confirms that the phase variation is due to an offset hot spot on the planet; (9) a retraction of the claimed eccentricity of this system due to the offset of secondary eclipse, which is now just an upper limit; and (10) high precision measurements of the parameters of this system. These results were enabled by the exquisite photometric precision of the Spitzer IRAC camera; for repeat observations the scatter is less than 0.35 mmag over the 590 day time scale of our observations after decorrelating with detector parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiclass Classification Using Bayesian Multivariate Adaptive Regression Splines

We present a new Bayesian model for the problem of multiclass classification. In this model, the probabilities of class membership of a given observation are determined by the mean of a latent Gaussian distribution. The mean functions of this latent distribution consist of combinations of highly flexible basis functions of the inputs: multivariate adaptive regression splines (MARS), first developed for multiple regression. We use reversible jump Markov chain Monte Carlo to make inference on the classification model, including the number of basis functions. We compare the probabilistic classification performance of our proposed approach to existing methods on simulated and benchmark data, and compare uncertainty estimates on simulated data. Our proposed method compares favorably with existing Bayesian and frequentist multiclass classification methods in out-of-sample probabilistic classification, and uncertainty estimation of these probabilistic classifications. We examine the fit of the proposed method to a data set of hurricane storm surge levels near Delaware Bay, US, and conclude that sea level rise is a key contributor to damage delivered by storm surge.

97 MATHEMATICS AND COMPUTING↗

Non-Targeted Effects Models Predict Significantly Higher Mars Mission Cancer Risk than Targeted Effects Models

Cancer risk is an important concern for galactic cosmic ray (GCR) exposures, which consist of a wide-energy range of protons, heavy ions and secondary radiation produced in shielding and tissues. Relative biological effectiveness (RBE) factors for surrogate cancer endpoints in cell culture models and tumor induction in mice vary considerable, including significant variations for different tissues and mouse strains. Many studies suggest non-targeted effects (NTE) occur for low doses of high linear energy transfer (LET) radiation, leading to deviation from the linear dose response model used in radiation protection. Using the mouse Harderian gland tumor experiment, the only extensive data-set for dose response modelling with a variety of particle types (>4), for the first-time a particle track structure model of tumor prevalence is used to investigate the effects of NTEs in predictions of chronic GCR exposure risk. The NTE model led to a predicted risk 2-fold higher compared to a targeted effects model. The scarcity of data with animal models for tissues that dominate human radiation cancer risk, including lung, colon, breast, liver, and stomach, suggest that studies of NTEs in other tissues are urgently needed prior to long-term space missions outside the protection of the Earth’s geomagnetic sphere.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

MEGASIM: Lifetimes and Resonances of Earth Trojan Asteroids—The Death of Primordial ETAs?

Abstract We present an analysis of lifetimes and resonances of Earth Trojan Asteroids (ETAs) in the MEGASIM data set. Trojan asteroids co-orbit the Sun with a planet, but remain bound to the Lagrange points, L4 (60° leading the planet) or L5 (60° trailing). In the circular three-body approximation, the stability of a Trojan asteroid depends on the ratio of the host planet mass and the central mass. For the inner planets, the range of stability becomes increasingly small, so perturbations from the planets have made primordial Trojans rare. To date, there have been just two ETAs (2010 TK 7 and 2020 XL 5 ), several Mars Trojans, and a Venus Trojan discovered. The estimated lifetimes of the known inner system Trojans are shorter than a million years, suggesting they are interlopers rather than members of a stable and long-lasting population. With the largest ETA n -body simulation to date, we are able to track their survival across a wide initialized parameter space. We find that the remaining fraction of ETAs over time is well fit with a stretched exponential function that, when extrapolated beyond our simulation run time, predicts zero ETAs by 2.33 Gyr. We also show correlations between ETA ejections and the periods of the Milankovitch cycles. Though Earth’s orbital dynamics dominate the instabilities of ETAs, we provide evidence that ETA ejections are linked to resonances found in the variation of the orbital elements of many if not all of the planets.

79 ASTRONOMY AND ASTROPHYSICS↗

Globally Averaged Atmospheric CFC-11 Concentrations: Monthly and Annual Data for the Period 1975-1992 (DB1010)

This data set presents globally averaged atmospheric concentrations of chlorofluorocarbon 11, known also as CFC-11 or F-11 (chemical name: trichlorofluoromethane; formula: CCl3F). The monthly global average data are derived from flask air samples collected at eight sites in six locations over the period August 1980-July 1992. The sites are Barrow (Alaska), Cape Meares (Oregon), Cape Kumukahi and Mauna Loa (Hawaii), Cape Matatula (American Samoa), Cape Grim (Tasmania), Palmer Station, and the South Pole (Antarctica). At each collection site, monthly averages were obtained from three flask samples collected every week. In addition to the monthly global averages available for 1980-992, this data set also contains annual global average data for 1975-1985. These annual global averages were derived from January measurements at the South Pole and in the Pacific Northwest of the United States (specifically, Washington state and the Oregon coast).For access to the data files, click this link to the CDIAC data transition website: http://cdiac.ess-dive.lbl.gov/ndps/db1010.html

54 ENVIRONMENTAL SCIENCES↗

In-House Alternative for Chemical Analyses of Rhenium and Sulfur in Glass

Accurate measurements of rhenium (Re) and sulfur (S) concentrations in solid samples are of critical importance for the key research activities at the Pacific Northwest National Laboratory (PNNL) Waste Form Development Laboratory (WFDL) related to Re behavior during waste glass melting process and solubility of S in glass. Southwest Research Institute (SwRI) has provided reliable services for chemical analysis needs at WFDL; however, its long turnaround time, occasionally up to 5 months, has caused some difficulties. An in-house method was developed for dissolving and fusing glass and feed samples in preparation for analyses by inductively coupled plasma-optical emission spectrometry and -mass spectrometry at a PNNL facility. Using a previously developed sodium hydroxide fusion method as a basis, four groups of samples from Hanford waste glass research were digested and fused at WFDL. The samples included 1) Enhanced low-activity waste glass correlation phase 2/3 melter glasses from the Vitreous State Laboratory at the Catholic University of America, 2) AN-102 dried feeds and glasses, 3) SS-AN-102 dried feeds and glasses, and 4) Integrated Research Project S solubility study glasses. We evaluated three different sets of solution preparation and analysis combinations, which included 1) a WFDL-prepared solution analyzed at SwRI, 2) a PNNLprepared solution analyzed at a laboratory in the Building-331at PNNL, and 3) an SwRIprepared solution analyzed at SwRI. We concluded that the PNNL in-house Re results can be used in parallel with the SwRI data based on the relative standard deviation values less than 6% from three different sets of solution preparation and analysis for all three groups of rhenium-containing samples tested. However, it was proposed that the in-house S data be used for the barium oxide-free glasses only because of the issue of barium sulfate precipitation in digestion/fusion solutions prepared from glasses containing barium oxide. In addition, higher analytical biases between the PNNL and SwRI S results are expected compared to the Re results, based on the relative standard deviation values of less than 10% from three different sets of solution preparation and analysis for two groups of S-containing samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydra: Computer Vision for Data Quality Monitoring

Hydra: Computer Vision for Data Quality Monitoring Mar 13, 2024, 4:15 PM 30m Charles B. Wang Center, Stony Brook University Poster Track 1: Computing Technology for Physics Research Poster session with coffee break Speaker Ayan Roy Description Hydra is an extensible framework for training, managing, and deploying machine learning models for near real-time data quality monitoring. It is designed to take some of the burden off of shift crews by providing ‘round-the-clock’ monitoring of plots representing the data being collected. The Hydra system is backed by a database which is leveraged for near push button training and is primarily controlled and viewed through a set of web interfaces. This web interface contains a simple-to-use web based GUI for labeling of the datasets used in training; making it possible to label thousands of images quickly and efficiently. To aid in the analysis of Hydra inferences gradCAM, a method of interpretability, is performed and overlaid on the target image, highlighting regions of interest, making diagnosis of problems much faster. Development began in 2019 for the GlueX Experiment in Hall-D, the Hydra system has grown to encompass all of the experimental halls at Jefferson Laboratory. This talk will focus on the features of Hydra as well as provide details of the challenges present with deploying to disparate experimental halls. With a roadmap of development established, Hydra aims to continue to grow in richness of feature set and expand to encompass other monitoring tasks in differing communities.

Roy, Ayan↗

End-to-End Models for Effects of System Noise on LIMS Analysis of Igneous Rocks

The ChemCam instrument on the Mars Science Laboratory will be the first extraterrestial deployment of laser-induced breakdown spectroscopy (UBS) for remote geochemical analysis. LIBS instruments are also being proposed for future NASA missions. In quantitative LIBS applications using multivariate analysis techniques, it is essential to understand the effects of key instrument parameters and their variability on the elemental predictions. Baseline experiments were run on a laboratory instrument in conditions reproducing ChemCam performance on Mars. These experiments employed Nd:YAG laser producing 17 mJ/pulse on target and an with a 200 {micro}m FWHM spot size on the surface of a sample. The emission is collected by a telescope, imaged on a fiber optic and then interfaced to a demultiplexer capable of >40% transmission into each spectrometer. We report here on an integrated end-to-end system performance model that simulates the effects of output signal degradation that might result from the input signal chain and the impact on multivariate model predictions. There are two approaches to modifying signal to noise (SNR): degrade the signal and/or increase the noise. Ishibashi used a much smaller data set to show that the addition of noise had significant impact while degradation of spectral resolution had much less impact on accuracy and precision. Here, we specifically focus on aspects of remote LIBS instrument performance as they relate to various types of signal degradation. To assess the sensitivity of LIBS analysis to signal-to-noise ratio (SNR) and spectral resolution, the signal in each spectrum from a suite of 50 laboratory spectra of igneous rocks was variably degraded by increasing the peak widths (simulating misalignment) and decreasing the spectral amplitude (simulating decreases in SNR).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recalibration of the Mars Science Laboratory ChemCam instrument with an expanded geochemical database

The ChemCam Laser-Induced Breakdown Spectroscopy (LIBS) instrument onboard the Mars Science Laboratory (MSL) rover Curiosity has obtained > 300,000 spectra of rock and soil analysis targets since landing at Gale Crater in 2012, and the spectra represent perhaps the largest publicly-available LIBS datasets. The compositions of the major elements, reported as oxides, have been re-calibrated using a laboratory LIBS instrument, Mars-like atmospheric conditions, and a much larger set of standards (408) that span a wider compositional range than previously employed. The new calibration uses a combination of partial least squares (PLS1) and Independent Component Analysis (ICA) algorithms, together with a calibration transfer matrix to minimize differences between the conditions under which the standards were analyzed in the laboratory and the conditions on Mars. While the previous model provided good results in the compositional range near the average Mars surface composition, the new model fits the extreme compositions far better. Examples are given for plagioclase feldspars, where silicon was previously significantly over-estimated, and for calcium-sulfate veins, where silicon compositions near zero were inaccurate. Here, the uncertainties of major element abundances are described as a function of the abundances, and are overall significantly lower than the previous model, enabling important new geochemical interpretations of the data.

47 OTHER INSTRUMENTATION↗

Harderian Gland Tumorigenesis: Low-Dose and LET Response

Increased cancer risk remains a primary concern for travel into deep space and may preclude manned missions to Mars due to large uncertainties that currently exist in estimating cancer risk from the spectrum of radiations found in space with the very limited available human epidemiological radiation-induced cancer data. Existing data on human risk of cancer from X-ray and gamma-ray exposure must be scaled to the many types and fluences of radiations found in space using radiation quality factors and dose-rate modification factors, and assuming linearity of response since the shapes of the dose responses at low doses below 100 mSv are unknown. The goal of this work was to reduce uncertainties in the relative biological effect (RBE) and linear energy transfer (LET) relationship for space-relevant doses of charged-particle radiation-induced carcinogenesis. The historical data from the studies of Fry et al. and Alpen et al. for Harderian gland (HG) tumors in the female CB6F1 strain of mouse represent the most complete set of experimental observations, including dose dependence, available on a specific radiation-induced tumor in an experimental animal using heavy ion beams that are found in the cosmic radiation spectrum. However, these data lack complete information on low-dose responses below 0.1 Gy, and for chronic low-dose-rate exposures, and there are gaps in the LET region between 25 and 190 keV/μm. In this study, we used the historical HG tumorigenesis data as reference, and obtained HG tumor data for 260 MeV/u silicon (LET ~70 keV/μm) and 1,000 MeV/u titanium (LET ~100 keV/μm) to fill existing gaps of data in this LET range to improve our understanding of the dose-response curve at low doses, to test for deviations from linearity and to provide RBE estimates. Animals were also exposed to five daily fractions of 0.026 or 0.052 Gy of 1,000 MeV/u titanium ions to simulate chronic exposure, and HG tumorigenesis from this fractionated study were compared to the results from single 0.13 or 0.26 Gy acute titanium exposures. Theoretical modeling of the data show that a nontargeted effect model provides a better fit than the targeted effect model, providing important information at space-relevant doses of heavy ions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Askival: An altered feldspathic cumulate sample in Gale crater

Askival is a light-toned, coarsely crystalline float rock, which was identified near the base of Vera Rubin Ridge in Gale crater. We have studied Askival, principally with the ChemCam instrument but also using APXS compositional data and MAHLI images. Askival and an earlier identified sample, Bindi, represent two rare examples of feldspathic cumulate float rocks in Gale crater with >65% relict plagioclase. Bindi appears unaltered whereas Askival shows textural and compositional signatures of silicification, along with alkali remobilization and hydration. Askival likely experienced multiple stages of alteration, occurring first through acidic hydrolysis of metal cations, followed by deposition of silica and possible phyllosilicates at low T and neutral-alkaline pH. Through laser-induced breakdown spectroscopy compositional analyses and normative calculations, we suggest that an assemblage of Fe-Mg silicates including amphibole and pyroxene, Fe phases, and possibly Mg-rich phyllosilicate are present. Thermodynamic modeling of the more pristine Bindi composition predicts that amphibole and feldspar are stable within an upper crustal setting. This is consistent with the presence of amphibole in the parent igneous rocks of Askival and suggests that the paucity of amphiboles in other known Martian samples reflects the lack of representative samples of the Martian crust rather than their absence on Mars.

58 GEOSCIENCES↗

Surrogate models for plasma displacement and current in 3D perturbed magnetohydrodynamic equilibria in tokamaks

Abstract A numerical database of over one thousand perturbed three-dimensional (3D) equilibria has been generated, constructed based on the MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) computed plasma response to the externally applied 3D field sources in multiple tokamak devices. Perturbed 3D equilibria with the n = 1–4 ( n is the toroidal mode number) toroidal periodicity are computed. Surrogate models are created for the computed perturbed 3D equilibrium utilizing model order reduction (MOR) techniques. In particular, retaining the first few eigenstates from the singular value decomposition (SVD) of the data is found to produce reasonably accurate MOR-representations for the key perturbed quantities, such as the perturbed parallel plasma current density and the plasma radial displacement. SVD also helps to reveal the core versus edge plasma response to the applied 3D field. For the database covering the conventional aspect ratio devices, about 95% of data can be represented by the truncated SVD-series with inclusion of only the first five eigenstates, achieving a relative error (RE) below 20%. The MOR-data is further utilized to train neural networks (NNs) to enable fast reconstruction of perturbed 3D equilibria, based on the two-dimensional equilibrium input and the 3D source field. The best NN-training is achieved for the MOR-data obtained with a global SVD approach, where the full set of samples used for NN training and testing are stretched and form a large matrix which is then subject to SVD. The fully connected multi-layer perceptron, with one or two hidden layers, can be trained to predict the MOR-data with less than 10% RE. As a key insight, a better strategy is to train separate NNs for the plasma response fields with different toroidal mode numbers. It is also better to apply MOR and to subsequently train NNs separately for conventional and low aspect ratio devices, due to enhanced toroidal coupling of Fourier spectra in the plasma response in the latter case.

3D equilibrium↗

Results from a multi-laboratory ocean metaproteomic intercomparison: effects of LC-MS acquisition and data analysis procedures

Metaproteomics is an increasingly popular methodology that provides information regarding the metabolic functions of specific microbial taxa and has potential for contributing to ocean ecology and biogeochemical studies. A blinded multi-laboratory intercomparison was conducted to assess comparability and reproducibility of taxonomic and functional results and their sensitivity to methodological variables. Euphotic zone samples from the Bermuda Atlantic Time-series Study (BATS) in the North Atlantic Ocean collected by in situ pumps and the autonomous underwater vehicle (AUV) Clio were distributed with a paired metagenome, and one-dimensional (1D) liquid chromatographic data-dependent acquisition mass spectrometry analysis was stipulated. Analysis of mass spectra from seven laboratories through a common bioinformatic pipeline identified a shared set of 1056 proteins from 1395 shared peptide constituents. Quantitative analyses showed good reproducibility: pairwise regressions of spectral counts between laboratories yielded R 2 values averaged 0.62±0.11, and a Sørensen similarity analysis of the top 1000 proteins revealed 70 %–80 % similarity between laboratory groups. Taxonomic and functional assignments showed good coherence between technical replicates and different laboratories. A bioinformatic intercomparison study, involving 10 laboratories using eight software packages, successfully identified thousands of peptides within the complex metaproteomic datasets, demonstrating the utility of these software tools for ocean metaproteomic research. Lessons learned and potential improvements in methods were described. Future efforts could examine reproducibility in deeper metaproteomes, examine accuracy in targeted absolute quantitation analyses, and develop standards for data output formats to improve data interoperability. Together, these results demonstrate the reproducibility of metaproteomic analyses and their suitability for microbial oceanography research, including integration into global-scale ocean surveys and ocean biogeochemical models.

59 BASIC BIOLOGICAL SCIENCES↗

COMBLE-ISLAS water isotopes in precipitation (COMBLEISLASISO)

During the measurement period, precipitation was sampled on daily to sub-daily basis with a sampling kit consiting of a clear plastic box (60x40x40 cm) mounted to a ground structure. Daily sampling lasted from 22 Feb to 24 Mar 2020. At a fixed time of day (10 UTC), samples were collected and the sampling box cleaned for the next sample. Additionally, during intense observations periods (IOPs) announced by ISLAS, ARMS scientists increased sampling frequency to sub-daily sampling. During the campaign period, 2 IOPs were conducted, with in total 12 samples taken. IOP1 lasted from 27 Feb 10 to 02 Mar 2020, and IOP2 lasted from 12 Mar to 14 Mar 2020. Solid precipitation in the box was then melted, transferred to an 8 ml glass vial, sealed and shipped to FARLAB (University of Bergen, Norway) for stable water isotope analysis. Measured stable isotope composition of precipitation samples will be related to conditions at other sampling locations, and at the evaporation site to inform about conservation of water isotope quantities. In the period from 22 Feb to 24 Mar, 23 daily samples were collected at 10 UTC for stable water isotope analysis. During the entire sampling period, a high variability of precipitation phase was encountered. Most samples were recovered in the form of graupel/snow (12 samples), as rain (7 samples), and the remaining samples fell as graupel, snow, rain or frozen rain. Precipitation amounts varied between <1 mm (26 Feb) and 140 mm (25 Feb) within the sampling box. Furthermore, higher-resolution sampling was conducted during 2 intense observation periods (IOPs). During IOP1, lasting from 27 Feb 10 UTC to 02 Mar 10 UTC, 7 samples were collected, all of them as solid phase precipitation. IOP2 lasted from 12 Mar 10 UTC to 14 Mar 09 UTC, and 5 samples (all as graupel/snow) were collected. Samples were processed according to FARLAB standard measurement procedures. In short, samples were transferred to 1.5 ml glass vials with rubber/PTFE septa (part #548-0907, VWR, USA). An autosampler (A0325, Picarro Inc) transferred ca. 2&micro;l per injection into a high-precision vapourizer (A0211, Picarro Inc, USA) heated to 110&deg;C. After blending with dry N2 (< 5 ppm H2O) the gas mixture was directed into the measurement cavity of a Cavity-Ring Down Spectrometer (L2140-i, Picarro Inc) for about 7 min with a typical water concentration of 20 000 ppm. Memory effects were reduced by two times measuring a vapour mixture at a mixing ratio of 50 000 ppm, obtained from 2 injections of 2 &micro;l for 5 min at the beginning of each new sample vial. Thereafter, another 6 injections of 2 &micro;l per sample were measured individually as described above, and averages of the last 5 injections were used for further processing. Three standards were measured at the beginning and end of each batch, including a drift standard DI2 (&delta;D: -50.72&plusmn;0.73 permil, &delta;18O: -7.63&plusmn;0.10 permil), and for calibration the laboratory standards GLW (&delta;D: -307.79&plusmn;0.75 permil, &delta;18O: -40.02&plusmn;0.07 permil) and EVAP2 (&delta;D: 9.52&plusmn;0.65 permil, &delta;18O: 1.81&plusmn;0.13 permil). A detailed calibration report is included with the final uploaded data set.

54 ENVIRONMENTAL SCIENCES↗