Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

Wide range multi-channel analog switch

A ten-channel analog switch has been developed as a sample and shape circuit for signals used as inputs to a logarithmic pulse height recording system. The circuit employs a field effect transistor as the switching element. Switching transients are reduced to approximately 2 mV by adding to the gated signal an inverted transient generated by an identical circuit with no signal applied. The circuit is linear to 2% from 3 mV to 10 V.

Levit, L. B.↗

Epitaxial silicon solar cells

P+/p/n/n+ epitaxial silicon solar-cell structures were fabricated with the n-base region intentionally graded over 2 orders of magnitude in a thickness of 35 microns. Solar cells made from these layers exhibited near-ideal I-V characteristics in the practical operating range, with an open-circuit voltage of 636 mV, fill factor of 0.79, and AM1 efficiency of 12.6%. A similar epitaxial structure containing no gradient in the n-base showed good solar-cell performance but lower open-circuit voltage (603 mV).

Daiello, R. V.↗

Light energy conservation processes in Halobacterium halobium cells

Proton pumping driven by light or by respiration generates an electrochemical potential difference across the membrane in Halobacterium halobium. The pH changes induced by light or by respiration in cell suspensions are complicated by proton flows associated with the functioning of the cellular energy transducers. A proton-per-ATP ratio of about 3 is calculated from simultaneous measurements of phosphorylation and the proton inflow. This value is compatible with the chemiosmotic coupling hypothesis. The time course of the light-induced changes in membrane potential indicates that light-driven pumping increases a dark pre-existing potential of about 130 mV only by a small amount (20 to 30 mV). The complex kinetic features of the membrane potential changes do not closely follow those of the pH changes, which suggests that flows of ions other than protons are involved. A qualitative model consistent with the available data is presented.

Bogomolni, R. A.↗

Analysis and application of minimum variance discrete linear system identification

An on-line minimum variance (MV) parameter identifier is developed which embodies both accuracy and computational efficiency. The formulation results in a linear estimation problem with both additive and multiplicative noise (AMN). The resulting filter which utilizes both the covariance of the parameter vector itself and the covariance of the error in identification is proven to be mean-square convergent and mean-square consistent. The MV parameter identification scheme is then used to construct a stable state and parameter estimation algorithm.

Kotob, S.↗

Electrochemical detection device

A standard pH reference electrode and a platinum cathodic electrode are positioned in a container with suitable nutrient medium for microbial growth plus the sample to be tested. The two electrodes are connected to electronic circuitry including an up/down counter whicn counts up for the first 80 minutes after a test has initiated. Then the potential between the two electrodes is tracked by the electronic circuitry and after there is a change of 10 mv a signal is sent to the up/down counter to cause it to reverse its count. When there is a additional 20 mv change in the potential between the two electrodes another signal is sent to the up/down counter, signalling it to stop. The resulting count on the counter is equal to the length of time for the inoculum to begin the production of measurable amounts of H2 after inoculation.

Young, R. N.↗

The alkaline zinc electrode as a mixed potential system

Cathodic and anodic processes for the alkaline zinc electrode in 0.01 molar zincate electrolyte (9 molar hydroxide) were investigated. Cyclic voltammograms and current-voltage curves were obtained by supplying pulses through a potentiostat to a zinc rotating disk electrode. The data are interpreted by treating the system as one with a mixed potential; the processes are termed The zincate and corrosion reactions. The relative proportions of the two processes vary with the supplied potential. For the cathodic region, the cathodic corrosion process predominates at higher potentials while both processes occur simultaneously at a lower potential (i.e., 50 mV). For the anodic region, the anodic zincate process predominates at higher potentials while the anodic corrosion process is dominant at lower potential (i.e., 50 mV) if H2 is present.

Fielder, W. L.↗

Development of a high efficiency thin silicon solar cell

Significant improvements in open-circuit voltage and conversion efficiency, even on relatively high bulk resistivity silicon, were achieved by using a screen-printed aluminum paste back surface field. A 4 sq cm 50 micron m thick cell was fabricated from textured 10 omega-cm silicon which had an open-circuit voltage of 595 mV and AMO conversion efficiency at 25 C of 14.3%. The best 4 sq cm 50 micron thick cell (2 omega-cm silicon) produced had an open-circuit voltage of 607 mV and an AMO conversion efficiency of 15%. Processing modifications are described which resulted in better front contact integrity and reduced breakage. These modifications were utilized in the thin cell pilot line to fabricate 4 sq cm cells with an average AMO conversion efficiency at 25 C of better than 12.5% and with lot yields as great as 51% of starts; a production rate of 10,000 cells per month was demonstrated. A pilot line was operated which produced large area (25 cm) ultra-thin cells with an average AMO conversion efficiency at 25 deg of better than 11.5% and a lot yield as high as 17%.

Storti, G.↗

Comparative energy spectra of z equals 3-8 nuclei in the energy range 200 MeV/nuc to 3 GeV/nuc

The energy spectra and charge ratios of Li, Be, B, C, N, and O nuclei in the energy range 200 MeV/nuc to 3 GeV/nuc are examined with measurements obtained during a 50 hour balloon flight in 1977 from a telescope containing several scintillation and Cerenkov counters. The ratios Li/C, Be/C, and B/C are compared with predictions based on the leaky box interstellar propagation model showing that the ratios steadily increase in the apparent interstellar matter path length down to energies of about 400 to 600 MeV/nuc, where it is between 6.5 and 7.5 g/square cm. The effects of solar modulation upon the ratios are considered for energies less than about 1 GeV/nuc as well as for a modulation parameters of phi not less than 400 MV. By examining the ratios Li/Be, Li/B, and Be/B as a function of energy, it is shown that the Li/Be ratio is most sensitive to the solar modulation effects, and that the observed changes in this ratio with energy can be explained by a relatively large modulation consistent with a phi equal to 400 MV in 1977.

Webber, W. R.↗

Signal analysis of voltage noise in welding arcs

Gas tungsten arc welds were made on low alloy steel plates to which intentional defects (discontinuities) were imposed. Disruption of shielding gas, welding over surface films, and tack welds produce changes in what is otherwise a relatively uniform voltage signal. The arc voltage was 15 volts + or - 2 volts with 300 mV ripple noise from the power supply. Changes in this steady noise voltage varied from 50 mV to less than one millivolt depending on the severity and the type of change experienced. In some instances the changes were easily detected by analysis of the signal in real time, while in other cases the signal had to transformed to the frequency domain in order to detect the changes. Discontinuities as small as 1.5 mm in length were detected. The ultimate sensitivity and reproducibility of the technique is still being investigated.

Elis, E.↗

Diagnostic study of BSF silicon solar cells

Solar cells equipped with back surface fields (BSF) were fabricated by means of an aluminum alloy, boron diffusion, and boron ion implantation. The importance of initial thickness, resistivity, orientation, and the crystal growth method were examined. Aluminum in paste form was screen printed on the cell, followed by alloy formation at 800 C for a minute. Application of the BSFs resulted in open circuit voltage improvements dependent on the substrate resistivity, ranging from 10 mV at 0.3 ohm-cm to 50 mV at 15 ohm-cm. The gains in performance were attributed to a longer penetration depth, a heightened concentration profile at the interface, and higher concentrations in the p+ layer.

Yoo, H.↗

Advances in high output voltage silicon solar cells

Solar cells have been fabricated from 0.1 ohm-cm, p-type silicon by means of a two-step diffusion process of emitter formation in order to delineate the factors limiting V(oc) in conventionally structured cells with the goal of achieving 700 mV. The cells are 200 microns thick and 2 x 2 cm in area with a planar front surface that has an anti-reflection coating of tantalum oxide, as well as Cr-Au-Ag contact metallization on both sides of the cell. The Cr-Au-Ag is applied over an aluminum diffused layer on the back, while it is applied through small holes in the anti-reflection coating on the front. Results show that the best of these cells exhibits an open-circuit voltage of 654 mV under AMO illumination.

Arndt, R. A.↗

Reduction of solar cell efficiency by edge defects across the back-surface-field junction - A developed perimeter model

Material imperfections, impurity clusters and fabrication defects across the back-surface-field junction can degrade the performance of high-efficiency solar cells. The degradation from defects appearing on the circumference of a solar cell is analyzed using a two-region developed perimeter device model. The width of the defective perimeter region is characterized by the range or the distance-of-influence of the defective edge and this width is about two diffusion lengths. The defective edge is characterized by a surface recombination velocity. Family of theoretical curves and numerical examples are presented to show that significant reduction of open-circuit voltage can occur in high-efficiency cells which are thin compared with the diffusion length. In one example, the degradation is decreased from 135 mV to 75 mV when the cell size is increased from 10 to 100 times the diffusion length in a thin cell whose thickness is 1% of the diffusion length.

Sah, C. T.↗

Developments toward an 18% efficient silicon solar cell

Limitations to increased open-circuit voltage were identified and experimentally verified for 0.1 ohm-cm solar cells with heavily doped emitters. After major reduction in the dark current contribution from the metal-silicon interface of the grid contacts, the surface recombination velocity of the oxide-silicon interface of shallow junction solar cells is the limiting factor. In deep junction solar cells, where the junction field does not aid surface collection, the emitter bulk is the limiting factor. Singly-diffused, shallow junction cells have been fabricated with open circuit voltages in excess of 645 mV. Double-diffusion shallow and deep junctions cells have displayed voltages above 650 mV. MIS solar cells formed on 0.1 ohm-cm substrates have exibited the lowest dark currents produced in the course of the contract work.

Meulenberg, A., Jr.↗

Process Research on Polycrystalline Silicon Material (PROPSM)

The performance limiting mechanisms in large grain (greater than 1-2 mm in diameter) polycrystalline silicon was investigated by measuring the illuminated current voltage (I-V) characteristics of the minicell wafer set. The average short circuit current on different wafers is 3 to 14 percent lower than that of single crystal Czochralski silicon. The scatter was typically less than 3 percent. The average open circuit voltage is 20 to 60 mV less than that of single crystal silicon. The scatter in the open circuit voltage of most of the polycrystalline silicon wafers was 15 to 20 mV, although two wafers had significantly greater scatter than this value. The fill factor of both polycrystalline and single crystal silicon cells was typically in the range of 60 to 70 percent; however several polycrystalline silicon wafers have fill factor averages which are somewhat lower and have a significantly larger degree of scatter.

Culik, J. S.↗

Layered transition metal thiophosphates /MPX3/ as photoelectrodes in photoelectrochemical cells

Layered crystals of the transition metal thiophosphates were synthesized and characterized for use as photoelectrodes in photoelectrochemical cells. Crystals incorporating tin and manganese show n-type response while those with iron and nickel show p-type response. These materials have a measured indirect bandgap of about 2.1 eV. They show ability to photoelectrolyze water in acid solutions with onset potentials which change in a Nernstian way as the PH of the solution changes. The onset potential is near zero volts versus a saturated calomel electrode at pH 2. At n-type crystals, oxygen could be evolved upon irradiation at underpotentials of 850 mV and at p-type crystals, hydrogen could be evolved at underpotentials of 400 mV, indicating a net gain in energy conversion. All crystals were unstable in basic solution. Liquid junction photovoltaic cells in iodide-triiodide acid solution using these layered materials were also constructed and found to have low efficiences.

Byvik, C. E.↗

Extragalactic 1 millimeter sources - Simultaneous observations at centimeter, millimeter, and visual wavelengths

Observations simultaneously made at visual (B, V, and R) wavelengths, at 1, 1.4, and 3.4 mm and at 1.3, 2, 6, and 20 cm of 9 QSOs and BL Lac objects are reported. The range of the millimeter-visual spectral index alpha sub mv was only 0.65-0.82, typical of optically thin synchrotron emission. This may indicate that the electrons radiating synchrotron emission in this portion of the spectrum are not subjected to large radiation losses, and therefore relativistic bulk motion with Doppler factors of about 10 are required. The visual spectral index is much more broadly distributed and typically larger than alpha sub mv. The spectral energy distributions have not changed much in the last two to five years except for 2251+15 and perhaps 0235+164. Only 1749+09 shows a sharp spectral break shortward of 1 mm. Sixteen other sources were observed at 1 mm, of which seven were detected.

Landau, R.↗

Cepheid distances from blue main-sequence companions

The absolute visual magnitudes of main-sequence Cepheid companions are here determined from their effective temperatures. The latter are obtained by comparing the measured relative energy distributions with model atmosphere energy distributions. Assuming an average Galactic extinction law, it is found that the distance moduli for the Cepheids should be smaller by Delta (mv-Mv) = -0.5 as compared to the Sandage-Tammann relation.

Bohm-Vitense, E.↗