Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids: Preprint

Increased deployment of Distributed Energy Resources (DERs) and microgrids are significantly changing the operation of distribution grid. Increasing penetration of power electronics based DERs also raise several operational problems such as protection coordination issues, voltage raise, recloser synchronization, stability, and frequency control. Legacy systems are designed for unidirectional power flow. Bidirectional power flows, and varying short circuit levels are some of the major challenges in implementing these legacy protection schemes for future power grid with high penetration of power electronics based DERs. Inverter based DER’s can contribute to a maximum of 2 p.u. fault current. Interconnection standards might require even lower fault current contribution. If these protection related challenges are not addressed, it will result in limiting the penetration of DERs in distribution feeders. In this paper, the feasibility of high frequency signature generated by transients is evaluated to identify and locate faults in a distribution system. The paper will discuss the need for an accurate line modeling approach to accurately capture the high frequency signatures. These high frequency signatures are naturally occurring electromagnetic transients for events such as switching events in the network, faults events, etc. This is different than that implemented in transmission systems as the proposed approach utilizes advanced signal processing techniques to retrieve valuable information from the high frequency signatures generated during faults and does not just rely on time delay measurements between reflections of the high frequency signals. In the full paper, information of a modified IEEE distribution feeder test system to accurately model the high frequency signatures will be provided. The distribution lines will be modeled using universal line modeling (ULM) technique in an electromagnetic transients program (EMTP) modeling platform. Different test cases will be simulated and these test cases will include different fault types, multiple fault locations, capacitor bank switching, etc. The feeder system modeled for these simulations will also include power electronics based DERs. Additionally, experimental results demonstrating the high frequency signatures generated due to a transient event in a medium voltage (13.8 kV) distribution line will also be presented in the full paper. Furthermore, the analysis combined with simulation and experimental results in the full paper will help demonstrate the feasibility and efficacy of the proposed protection scheme. The developed protection scheme will not just help solve problems generated by bidirectional current flow, varying short-circuit current capacity, but also help in proliferation of DERs in distribution systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

200 MV Record Voltage Of vCM And LCLS-II-HE Cryomodules Production Start At Fermilab

The Linac Coherent Light Source (LCLS) is an X-ray science facility at SLAC National Accelerator Laboratory. The LCLS-II project (an upgrade to LCLS) is in the commissioning phase; the LCLS-II-HE (High Energy) project is another upgrade to the facility, enabling higher energy operation. An electron beam is accelerated using superconducting radio frequency (SRF) cavities built into cryomodules. It is planned to build 24 1.3 GHz standard cryomodules and one 1.3 GHz single-cavity Buncher Capture Cavity (BCC) cryomodule for the LCLS-II-HE project. Fourteen of these standard cryomodules and the BCC are planned to be assembled and tested at Fermilab. Procurements for standard cryomodule components are nearing completion. The first LCLS-II-HE cryomodule, referred to as the verification cryomodule (vCM) was assembled and tested at Fermilab. Fermilab has completed the assembly of the second cryomodule. This paper presents LCLS-II-HE cryomodule production status at Fermilab, emphasizing the changes done based on the successes, challenges, mitigations, and lessons learned from LCLS-II; validation of the changes with the excellent vCM results.

43 PARTICLE ACCELERATORS↗

Loss Analysis and Performance Optimization Pathways of 729-mV VocSi Solar Cells with Poly-Si on Locally-Etched Dielectric Passivating Contacts

In this article, the performance analysis of a 22.5% efficient polysilicon on silicon oxide (poly-Si/SiOx) passivated contact solar cells with deliberately introduced pinholes using metal-assisted chemical etching (MACE) has been performed with the help of optical analysis using Sunsolve and electrical analysis using Quokka3. The power loss is maximum due to recombination and resistive losses in the bulk (~0.76 mW/cm2 ) followed by power loss due to rear contact recombination (~0.35 mW/cm2 ). Recombination at the front surface also contributes to 0.24 mW/cm2. The effect of improving the bulk lifetime and lowering the recombination current density at the rear side on Voc, FF and efficiency has been investigated.

MACE↗

Influence of Solutocapillary Convection on Macrovoid Defect Formation in Polymeric Membranes

Macrovoids (MVs) are large (10-50 micrometers) pores often found in polymeric membranes prepared via phase-inversion techniques. They are generally considered undesirable, as they adversely affect the permeability properties and performance of polymeric membranes for microfiltration, ultrafiltration, and reverse osmosis. However, MVs can be useful in certain thin-film applications in which vapor transmission is necessary, or for use as reservoirs for enzymes or liquid membrane material. If more could be learned about the nature and causes of MV formation, it might be possible to devise techniques to control and/or prevent MV formation that are more effective than those currently employed. Two hypotheses for the MV growth mechanism have been advanced. Reuvers proposed that once initiated, MV growth can be attributed to diffusion of (primarily) solvent to the MV nuclei. Because this mechanism does not involve gross movement of the MV, the presence or absence of body forces such as buoyancy should not significantly affect MV growth. On the other hand, Shojaie et al. proposed that solutocapillary convection induced by a steep surface-tension gradient along the MV/bulk solution interface enhances mass transfer to the growing MV. This interfacial convection exerts a force that pulls the growing MV downward into the casting solution. Both buoyancy and viscous drag hinder MV growth by inhibiting this motion. Thus, removing the buoyancy force by casting in microgravity should augment MV growth according to this hypothesis. Whereas neither surface tension nor gravity has a significant effect on MV growth according to the first hypothesis, buoyancy forces should be important if the second hypothesis is correct. The overall goal of this research is to test these two hypotheses in order to improve our understanding of the MV growth processing solvent-cast polymeric membranes. Studying MV growth in low-gravity conditions is pivotal to our ability to discriminate between these two hypotheses.

Pekny, M. R.↗

Influence of Solutocapillary Convection on Macrovoid Defect Formation in Polymeric Membranes

The focus of this research project involved the dry-cast process for polymeric membrane formation, whereby evaporation of solvent from an initially homogeneous polymer/solvent/ nonsolvent solution results in phase separation and the formation of polymer-rich and polymer-lean phases. Under certain conditions the polymer-lean phase gives rise to very large and usually undesirable, tear-drop-shaped pores (size approx. 10 - 50 microns) termed macrovoids (MVs). Although in many cases the presence of MV pores has deleterious effects on membrane performance, there are a number of innovative applications where the presence of such pores is highly desirable. Although researchers have proposed a variety of mechanisms for MV formation over the past three decades, two main hypotheses are currently favored: one asserts that MV growth can be attributed solely to diffusion (the diffusive growth hypothesis), whereas the other states that solutocapillary convection (the SC hypothesis) at the MV interface contributes to growth. The overall goal of this research was to obtain a more comprehensive understanding of the fundamental mechanism of MV growth. This research incorporates a coupled modeling and experimental approach to test a solutocapillary convection hypothesis for the growth of macrovoid pores in polymeric membranes. Specifically, we utilized a modification of the first principles model developed by two of the PIs (ARG and WBK) for dry-cast CA membranes. For the experimental component, two separate and mutually complementary approaches were used to study MV growth. In the first, membranes cast in a zero-g environment aboard the NASA KC-135 aircraft were compared with those cast on the ground to assess the effect of the buoyancy force on membrane morphology and MV size and shape. In the second approach, videomicroscopy flow visualization (VMFV) was utilized to observe MV formation and growth in real time and to assess the effect of surface tension on the MV growth dynamics. As a result of these fundamental studies, our research group advanced a new hypothesis for MV pore development in polymeric membranes.

Greenberg, Alan R.↗

Multi-Electron Transfer at H-Terminated p-Si Electrolyte Interfaces: Large Photovoltages under Inversion Conditions

Here, photovoltages for hydrogen terminated p-Si(111) in an acetonitrile electrolyte were quantified with methyl viologen [1,1'-(CH 3 ) 2 -4,4'-bipyridinium](PF 6 ) 2 , abbreviated MV 2+ , and [Ru(bpy) 3 ](PF 6 ) 2 , where bpy is 2,2'-bipyridine, that respectively undergo two and three one-electron transfer reductions. The reduction potentials, E°, of the two MV 2+ reductions occurred at energies within the forbidden bandgap, while the three [Ru(bpy) 3 ] 2+ reductions occurred within the continuum of conduction band states. Bandgap illumination resulted in reduction that were more positive than that measured with a degenerately doped n + -Si demonstrative of a photovoltage, Vph, that increased in the order: MV 2+/+ (260 mV) < MV +/0 (400 mV) < Ru 2+/+ (530 mV) ~ Ru +/0 (540 mV) ~ Ru 0/– (550 mV). Pulsed 532 nm excitation generated electron-hole pairs whose dynamics were nearly constant under depletion conditions and increased markedly as the potential was raised or lowered. A long wavelength absorption feature assigned to conduction band electrons provided additional evidence for the presence of an inversion layer. Collectively, the data reveal that the most optimal photovoltage, as well at the longest electron-hole pair lifetime and the highest surface electron concentration, occur when E° lies energetically within the unfilled conduction band states where an inversion layer is present. The bell-shaped dependence for electron-hole pair recombination with the surface potential was predicted by the time-honored SRH model providing a clear indication that this interface provides access to all four bias conditions, i.e., accumulation, flat band, depletion, and inversion. The implications of these findings for photocatalysis applications and solar energy conversion are discussed.

14 SOLAR ENERGY↗

A distinct subpopulation of membrane vesicles in Pseudomonas putida is enriched in enzymes for lignin catabolism

Bacterial membrane vesicles (MVs) mediate diverse microbial processes and are emerging as powerful biomedical tools, but MV population heterogeneity remains an open question. Here, we separate, enumerate, and characterize two MV populations from the soil bacterium Pseudomonas putida during growth with or without lignin-derived carbon, a major carbon source from plant cells in the rhizosphere. Small MVs (MV-S, diameter ~100 nm) were produced from all cultures, whereas large MVs (MV-L, diameter ~300 nm) were observed during the late stationary phase of lignin cultivations. MV-S contained selectively packaged proteins with diverse physiological functions, whereas the MV-L proteome was smaller and largely enriched in outer membrane proteins. Interestingly, enzymes known to mediate the catabolism of lignin-derived aromatic compounds were enriched in MV-S. Overall, this study highlights the need for careful consideration of MV populations in microbial systems.

59 BASIC BIOLOGICAL SCIENCES↗

Macrovoid Defect Growth during Evaporative Casting of Polymeric Membranes

Macrovoid (MV) formation is a significant problem in evaporatively cast polymeric membranes. MVs are large, elongated or teardrop-shaped pores (~10-50 micron) that can impair membrane structural integrity. Although MVs have been extensively studied, there is no general agreement on the mechanisms governing MV growth. Recently, our research group has formulated the solutocapillary convection (SC) hypothesis, which contends that MV growth involves three principal forces: a Marangoni force generated by surface tension gradients within the MV interface, a viscous drag force, and a gravitationally induced body force. Two sets of complementary experiments were conducted to test the SC hypothesis. Ground-based videomicroscopy flow-visualization (VMFV) was utilized to measure the flow velocities at the MV-casting solution interface and deep within the casting solution. The measurements were performed with casting solutions containing 10 wt% cellulose acetate (CA), 30 wt% H2O, 60 wt% acetone, and 200- ppm TiO2 particles for flow visualization, and the surface tension was controlled by surfactant addition. Qualitatively, the experiments indicated that MV growth occurs in three distinct phases: (1) a very rapid initial growth period, (2) a much slower growth phase, and (3) absorption of selected MVs into the expanding demixed region. The presence of tracer particles inside the MVs suggests the presence of a convective flow, which transfers the particles from the bulk solution to the MV interior. Although the VMFV experiments did not establish any surfactant effect on the interfacial velocities, a statistically significant effect on the MV number density was observed. In the second set of experiments, membranes were cast aboard a KC-135 aircraft under 0-g and 2-g conditions. Despite careful attention to the design and fabrication of the membrane casting apparatus (MCA), several problems were encountered, the most significant of which was the contamination of the casting solution by the activated carbon particles used for solvent absorption.

Greenberg, A. R.↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

H-cluster Intermediates and Catalytic Properties of Clostridium pasteurianum [FeFe]-Hydrogenase III

[FeFe]-Hydrogenases are structurally diverse enzymes that catalyze reversible H2 activation at a catalytic cofactor or H-cluster. The H-cluster is a [4Fe-4S] cubane linked by a cysteine thiolate to a diiron subsite containing unique CO, CN-, and dithiomethylamine ligands. The established H-cluster resting state of [4Fe-4S]2+-[FeII-FeI], or Hox, functions in H2 binding and oxidation, or by proton-coupled reduction initiates H2 evolution. In contrast, in Clostridium pasteurianum [FeFe]-hydrogenase III (CpIII) the resting state of the H-cluster is fully oxidized, [4Fe-4S]2+-[FeII-FeII], or Hox+1. To begin to understand if Hox+1 has a role in the mechanism of CpIII, we determined the spectroscopic and redox properties of CpIII H-cluster states under catalytic conditions. CpIII poised in Hox+1 and either equilibrated under 1 atm of H2 or reduced with sodium dithionite, resulted in a mixture of reduced states including Hox (Em8 = -407 mV), Htrans-like [4Fe-4S]+-[FeII-FeII] (Em8 = -418 mV), Hred [4Fe-4S]+-[FeII-FeI], and HredH+ [4Fe-4S]2+-[FeI-FeI] (Em8 = -455-480 mV). Under H2 the population of the Htrans-like state was >20-fold higher than Hox, implicating a role in CpIII catalysis. Unlike other enzymes, there was no spectral evidence of fully reduced states, such as HsredH+ ([4Fe-4S]+-[FeI-FeI]) or Hhyd ([4Fe-4S]+-[FeII-FeII]-H-). Thus, while the H-cluster states of CpIII encompass most of the catalytic intermediates, it is either unable to form HsredH+ and Hhyd, or these states are highly destabilized in CpIII. Thus, these results demonstrate that catalytic intermediates of reduced CpIII differ from the typical intermediates of other catalytic [FeFe]-hydrogenases and may explain the catalytic preference for H2 production.

08 HYDROGEN↗

In Situ Imaging Reveals Efficient Charge Separation in Monolayer MoS 2 –WS 2 Type-II Heterojunctions

Covalently bonded in-plane two-dimensional (2D) transition metal dichalcogenide (TMD) heterojunctions with atomically sharp interfaces hold great promise for photocatalytic applications in solar energy conversion and environmental remediation; however, their spatially resolved charge distribution and transport, particularly under operando conditions, remain poorly understood. Here, we employ photoscanning electrochemical microscopy (photo-SECM) to directly visualize photoinduced charge separation in monolayer MoS 2 –WS 2 in-plane heterojunctions. Spatial separation of photogenerated carriers is observed, with electrons accumulating in MoS 2 and holes in WS 2 , leading to strongly asymmetric interfacial kinetics: Fc + reduction proceeds rapidly on MoS 2 (0.6 cm s –1 ), whereas Fc oxidation on WS 2 is significantly slower (0.008 cm s –1 ). High-resolution surface photovoltage microscopy (SPVM) enables a quantitative comparison of charge-separation capacity across architectures. The in-plane MoS 2 –WS 2 heterojunction shows the largest photovoltage contrast (−35 mV in MoS 2 , 20 mV in WS 2 ), exceeding the vertical heterojunction (−18 mV in MoS 2 , 11 mV in WS 2 ) and the individual monolayers (−12 mV for MoS 2 , – 1 mV for WS 2 ), establishing the following trend: in-plane > vertical > monolayers. Ultraviolet photoelectron spectroscopy (UPS) indicates that this directional charge separation is driven by intrinsic type-II band alignment, while photoluminescence (PL) imaging shows that the interface acts as a recombination center that limits efficient carrier extraction. These results provide direct experimental evidence of type-II-driven charge separation in in-plane heterojunctions and offer critical insights for interface design in high-efficiency photocatalytic and optoelectronic systems.

electrical properties↗

Targeted synthesis and reaction mechanism discussion of Mo 2 C based insertion-type electrodes for advanced pseudocapacitors

Mo 2 C is one of the few compounds that possess good electronic conductivity. Meanwhile, it possesses a natural 1D zigzag tunnel structure that is ideally suited for fast ion diffusion. Here, an effective approach is demonstrated for fabrication of structurally stable N-doped Mo 2 C/C nanobelts. They demonstrate high and fast energy storage ability with initial capacitances of 1139 C g -1 at 1 mV s-1, 151 C g -1 at an extremely high scan rate of 2000 mV s -1 and 208 C g -1 at a discharge current density of 200 A g -1 . After electrochemical activation of cycling, the capacity is continuously enhanced and much higher capacitances of 2523 C g -1 at 1 mV s -1 and 1403 C g -1 at 50 A g -1 are achieved after 15,000 cycles at 50 mV s -1 . Using the power law, it is evaluated that a surface-controlled capacitive process makes the main contribution to the capacity, which is over 90% when the scan rates are higher than 10 mV s -1 and still high as 73% at 1 mV s -1 . From in situ synchrotron XRD, it is found that there is a negligible change in the crystal structure and volume during charging/discharging, reflecting an insertion-type charge storage mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Design, Control, and Protection of a 13.2 kV, 1 MVA Solid State Transformer for Electric Vehicle Extreme Fast Charging Station

In this article, a medium-voltage (MV) ac-dc solid state transformer (SST) for electric vehicle (EV) extreme fast charging (XFC) station is proposed. The SST adopts a cascaded H-bridge (CHB)-based structure where the active front end (AFE) power stages are connected in input-series followed by dual active bridge (DAB) converters connected in an output-parallel configuration providing galvanic isolation through a high-frequency transformer (HFT). The SST is rated for 1 MVA and connects directly to a three-phase 13.2 kV MV ac grid through ac switchgear and outputs 750-V dc. At the dc bus, several dc/dc converters are connected, each of which can charge an EV based on its battery capacity. A novel decentralized control architecture of the SST is adopted in this work which simplifies the MV dc link voltage and module-level power balancing. In addition, the local and central protection designs of the SST are presented which identify and respond to the internal fault of the system. Finally, the experimental validations of the SST hardware prototype are presented up to the rated voltage. Furthermore, this article details the design and implementation of the MV SST addressing the challenges of an isolated MV class power converter for connecting directly to the MV ac grid with unique controller architecture, distributed protection framework, and SST constructional features.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multithreaded copy ('cp')

This is a modification to 'cp' and 'mv' commands to make them multi-threaded. Simple benchmarks showed that multi-threading could reduce the time to copy a large Linux source directory by over 2x. The 'cp' and 'mv' utilities are part of the existing Coreutils (https://www.gnu.org/software/coreutils/) software package that get installed on all Linux distros. Changes: * Add '-j|--parallel ' flags to 'cp' and 'mv'. This allows the utilities to recursively copy regular files in directories in parallel. This does NOT parallelize multiple single file copies to a destination (like 'cp file2 file2 file3 dst/'). Along with this, add in new 'CP_NUM_THREADS' and 'MV_NUM_THREADS' environment variables to set the number of threads. This can be useful when you want to enable parallelism by default in /etc/profile. The maximum number of threads is internally capped to the number of CPUs. * Add a '-j' flag to 'sort' to complement its existing '--parallel' flag. This is only done for consistency with 'cp' and 'mv'. * Add test cases for the new flags. Also, run each 'cp' and 'mv' test both in single-threaded and multithreaded modes for extra coverage.

Hutter, AnthonyJ [Lawrence Livermore National Labo↗

Refinement of Salt Dissolution Inhibitor Requirements (Final Report)

At Savannah River Site (SRS), High-Level Waste is stored in below-grade carbon steel tanks. This waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for future processing involves dissolution of the salt cake layer. The salt dissolution process can create conditions that leave the carbon steel tanks susceptible to localized corrosion. The salt to be dissolved contains high concentrations of nitrate, that once released, create an environment that may be conducive to pitting corrosion and/or stress corrosion cracking (SCC) of carbon steel. The salt dissolution process also liberates interstitial liquid trapped between the salt crystals. This liquid is initially high in nitrite and hydroxide concentration. High pH and greater ratios of nitrite to nitrate act as inhibitors to minimize corrosion of carbon steel in high nitrate environments. However, as dissolution proceeds, the concentration of nitrate will increase, while the hydroxide and nitrite concentration of the interstitial liquid will deplete and become insufficient to prevent the onset of corrosion attack. Tank blending and addition of inhibitors are used to ensure adequate concentrations of hydroxide and nitrite. However, this is not desirable during salt dissolution as it can reduce process efficiency and increase the amount of waste that needs processing. It has been proposed that these corrosion control limits be revisited to evaluate the corrosion susceptibility of carbon steel in environments that more closely resemble current operating conditions at SRS. An experimental matrix was designed to evaluate the use of the pitting factor for supernate chemistries characteristic to SRS, particularly during the salt dissolution process. Two electrochemical methods were identified to determine the susceptibility of A537 and A285 low-carbon steels to pitting corrosion with this chemistry envelope at temperatures up to 75 °C. The predominant electrochemical test method was Cyclic Potentiodynamic Polarization (CPP) studies. Through CPP, the pitting factor was used, based on Hanford Site corrosion studies, to accurately identify pitting susceptibility within the compositional range studied with some conservatism. Additionally, sulfate was determined to have no statistically significant influence, at concentrations up to 0.6 M, on pitting behavior in more concentrated solutions where other aggressive species govern pitting susceptibility. Where CPP was inconclusive, Modified ASTM G192 was successfully used to evaluate pitting susceptibility conditions and allowed for a pass/fail result to be determined. In all cases, the pitting factor was determined to be applicable to the simulants tested, with this metric accurately predicting incidences in which pitting occurred. Based upon the findings in this work, a pitting factor of 1.2 is being proposed to build in a safety factor and remain consistent with the Hanford Site approach. Additionally, a minimum pH limit of 12 is proposed to ensure carbon steel passivity and localized corrosion the primary degradation mechanism. Susceptibility to SCC was evaluated using a reduced matrix of tests at 75 °C. No failures due SCC were observed at open circuit. In addition, tests polarized anodically by 200 mV only resulted in failures for trials with pitting factors less than 0.86. However, a test with a passing condition based upon the pitting factor metric (pitting factor = 1.40) did exhibit a failure with an applied potential of +300 mV vs. OCP. This result is contrary to the prediction based upon the pitting factor, however, a polarization of 300 mV, or even 200 mV, from open circuit is substantial. The relationship between these testing parameters and service environment/conditions and the desired level of conservatism in the metric should be further evaluated in the determination of the significance of this result. While the pitting factor accurately predicted susceptibility to SCC at temperatures up to 75 °C and with positive overpotentials up to 200 mV, the relatively small sample matrix and failure of a passing pitting factor with a 300 mV polarization resulted in an inconclusive determination of whether the pitting factor may be used for predicting susceptibility to SCC at temperatures between 50 °C and 75 °C. As such, additional testing is recommended to evaluate the validity of the pitting factor for SCC susceptibility prediction at temperatures between 50 °C and 75 °C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗