Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONOCHROMATORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Milli-electronvolt monochromatization of hard X-rays with a sapphire backscattering monochromator

A sapphire backscattering monochromator with 1.1 (1) meV bandwidth for hard X-rays (20–40 keV) is reported. The optical quality of several sapphire crystals has been studied and the best crystal was chosen to work as the monochromator. The small energy bandwidth has been obtained by decreasing the crystal volume impinged upon by the beam and by choosing the crystal part with the best quality. The monochromator was tested at the energies of the nuclear resonances of 121 Sb at 37.13 keV, 125 Te at 35.49 keV, 119 Sn at 23.88 keV, 149 Sm at 22.50 keV and 151 Eu at 21.54 keV. For each energy, specific reflections with sapphire temperatures in the 150–300 K region were chosen. Applications to nuclear inelastic scattering with these isotopes are demonstrated.

47 OTHER INSTRUMENTATION↗

All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source

A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal, with a thickness of ~100 µm, provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. This article reports the design, fabrication and X-ray characterization of the first and second (300 µm-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 × 2 mm with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 × 2 mm working regions of the crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bent Bragg–Laue monochromator for high-energy X-rays

A bent Bragg–Laue monochromator (BLM) is proposed for high-energy X-ray (~25–60 keV) beamlines. The BLM has the unique feature of bi-directional focusing. A sagittally bent Laue crystal can focus the large horizontal fan of a bending magnet or wiggler source. A meridionally bent Bragg crystal focuses the beam vertically and corrects for the anticlastic bending effects of the Laue crystal. This monochromator geometry relies on the crystal orientations being optimized. We show that the focusing condition and Rowland condition can be simultaneously satisfied at a given energy. A detailed ray tracings indicate that a BLM can provide similar energy resolution and higher flux density compared to a sagittally bent double-Laue monochromator configuration. A prototype BLM with a symmetric Bragg crystal and an asymmetric Laue crystal was tested. Matching of the bend radii of the two crystals in the meridional direction was demonstrated. Generally, the horizontal acceptance of the sagittally bent Laue crystal is limited by the large curvature. This horizontal BLM acceptance could be increased by translating the Laue crystal along its sagittal bending axis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarizer-Free Acousto-Optic Monochromators

Monochromators based on a noncollinear acousto-optic filter without external polarizers have been studied. As an element to select an operating diffracted light beam, (1) a spatial filter-telescope and (2) an output plane of a filter crystal rotated in a diffraction plane have been used. In the latter case, dispersion of the acousto-optic filter crystal is compensated using a correcting prism made from the same crystal and placed behind an output filter plane along a path of a filtered light beam. As a result, the transmission coefficient of the monochromator is increased upon an effective compensation of the angular drift of the filtered light beam, the monochromator design is simplified, and its sizes are decreased.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Tunable Resolution Grating Monochromator and the Quest for Transform Limited Pulses

A variable resolution, transform limited monochromator is designed for the Free Electron Laser (FEL) source of LCLS. It provides monochromatic beam in the 250–1500 eV range, delivering the beam on the second floor of the LCLS experimental Hall. One major requirement for this monochromator is to provide, as close as possible, monochromatic transform limited pulses for time-resolved experiments. The theory and the limit of using classical diffraction scheme to monochromatize Soft X-ray beam, while preserving the pulse length, will be presented, together with the optical scheme of this versatile monochromator design.

47 OTHER INSTRUMENTATION↗

Resolution enhancement in transmission electron microscopy with 60-kV monochromated electron source

Transmission electron microscopy (TEM) at low accelerating voltages is useful to obtain images with low irradiation damage. For a low accelerating voltage, linear information transfer, which determines the resolution for observation of single-layered materials, is largely limited by defocus spread, which improves when a narrow energy spread is used in the electron source. In this study, we have evaluated the resolution of images obtained at 60 kV by TEM performed with a monochromated electron source. The defocus spread has been evaluated by comparing diffractogram tableaux from TEM images obtained under nonmonochromated and monochromated illumination. The information limits for different energy spreads were precisely measured by using diffractograms with a large beam tilt. The result shows that the information limit reaches 0.1 nm with an energy width of 0.10 eV. With this monochromated source and a higher-order aberration corrector, we have obtained images of single carbon atoms in a graphene sheet by TEM at 60 kV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spherical analyzers and monochromators for resonant inelastic hard X-ray scattering: a compilation of crystals and reflections

Resonant inelastic X-ray scattering (RIXS) experiments require special sets of near-backscattering spherical diced analyzers and high-resolution monochromators for every distinct absorption-edge energy and emission line. For the purpose of aiding the design and planning of efficient RIXS experiments, comprehensive lists of suitable analyzer reflections for silicon, germanium, α-quartz, sapphire and lithium niobate crystals were compiled for a multitude of absorption edges and emission lines. Analyzers made from lithium niobate, sapphire or α-quartz offer many choices of reflections with intrinsic resolutions currently unattainable from silicon or germanium. In some cases these materials offer higher intensities at comparable resolutions. While lithium niobate, sapphire or α-quartz analyzers are still in an early stage of development, the present compilation can serve as a computational basis for assessing expected and actual performance. With regard to high-resolution monochromators, bandpass and throughput calculations for combinations of double-crystal, high-heat-load and near-backscattering high-resolution channel-cuts were assembled. The compilation of these analyzer and monochromator data is publicly available on a website.

47 OTHER INSTRUMENTATION↗

Diamond channel-cut crystals for high-heat-load beam-multiplexing narrow-band X-ray monochromators

Next-generation high-brilliance X-ray photon sources call for new X-ray optics. Here we demonstrate the possibility of using monolithic diamond channel-cut crystals as high-heat-load beam-multiplexing narrow-band mechanically stable X-ray monochromators with high-power X-ray beams at cutting-edge high-repetition-rate X-ray free-electron laser (XFEL) facilities. The diamond channel-cut crystals fabricated and characterized in these studies are designed as two-bounce Bragg reflection monochromators directing 14.4 or 12.4 keV X-rays within a 15 meV bandwidth to 57 Fe or 45 Sc nuclear resonant scattering experiments, respectively. The crystal design allows out-of-band X-rays transmitted with minimal losses to alternative simultaneous experiments. Only ≲2% of the incident ∼100 W X-ray beam is absorbed in the 50 µm-thick first diamond crystal reflector, ensuring that the monochromator crystal is highly stable. Other X-ray optics applications of diamond channel-cut crystals are anticipated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A monochromator based on W/C multilayers of 40 A layer spacing

The design and preliminary performance data are presented for a monochromator based on two multilayer X-ray mirrors. The monochromator is based on mirrors with a d-spacing of 40 A and is designed to operate in the 5-75 A wavelength regime which can be varied by interchanging the mirrors with ones of different d-spacing. The multilayer mirrors are fabricated using sputter deposition and typically consist of 40 layer pairs of W and C. Except for W/Si, which shows 1-2 percent better reflectivities over the 7-40 A range but 4-10 percent poorer reflectivities for wavelengths longer than 40 A and shorter than 7 A, calculations performed using other combinations of materials generally show poorer reflectivities over the wavelength range of interest. Plans for a four-mirror version of the monochromator that will have increased resolution are also presented.

Smith, A.↗

Four-Mirror X-Ray And Extreme-Ultraviolet Monochromator

More mirrors provide additional wavelength selectivity. Four-mirror x-ray and extreme-ultraviolet monochromator provides narrower wavelength passband than devices described in "Compact X-Ray and Extreme Ultraviolet Monochromator" (MFS-28499) and "Scanning X-Ray or Extreme Ultraviolet Monochromator" (MFS-28492). Relies on Bragg reflection from two identical parallel multilayer mirrors to extract narrow-spectrum x-ray or extreme-ultraviolet beam from broad-spectrum input beam.

Hoover, Richard B.↗

Thermal loading on self-seeding monochromators in x-ray free electron lasers

One approach to achieve longitudinally coherent hard X-ray free electron laser (XFEL) radiation is to introduce a single-crystal monochromator in the beam path to generate a co-propagating, time-synchronized self-seeding radiation pulse. For modern high-repetition rate XFELs, however, thermal loading on the crystal can degrade the quality of the seed pulse. To assess limitations on the maximum XFEL pulse repetition rate imposed by the seeding crystal, a comprehensive study of thermomechanical, and X-ray diffraction effects within the crystal is presented in this paper for two consecutive self-amplified spontaneous emission pulses incident on both reflective and transmissive crystal monochromators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

Isotope-Resolved Electron Energy Loss Spectroscopy in a Monochromated Scanning Transmission Electron Microscope

The development and implementation of high-stability monochromators in state-of-the-art aberration-corrected scanning transmission electron microscopes has enabled materials characterization with an energy resolution as good as 3 meV. This allows the vibrational modes, which would otherwise be obscured by the energy spread of the electron beam, to be probed with very high precision in molecular materials. Since the vibrational energies depend on the weight of the atomic nuclei, vibrational spectroscopy can distinguish isotopes whose only difference lies in their neutron content. This opens up isotopic analysis and mapping in transmission electron microscopy as two important new research areas. In this paper, we review the monochromated electron energy loss spectroscopy (EELS) instrumentation, discuss optimal methods for probing beam-sensitive materials without destroying them, and review key nanoscale isotope-resolved results.

47 OTHER INSTRUMENTATION↗

Periodic magnetic field as a polarized and focusing thermal neutron spectrometer and monochromator

A novel periodic magnetic field (PMF) optic is shown to act as a prism, lens, and polarizer for neutrons and particles with a magnetic dipole moment. The PMF has a two-dimensional field in the axial direction of neutron propagation. The PMF alternating magnetic field polarity provides strong gradients that cause separation of neutrons by wavelength axially and by spin state transversely. The spin-up neutrons exit the PMF with their magnetic spins aligned parallel to the PMF magnetic field, and are deflected upward and line focus at a fixed vertical height, proportional to the PMF period, at a downstream focal distance that increases with neutron energy. The PMF has no attenuation by absorption or scatter, as with material prisms or crystal monochromators. Embodiments of the PMF include neutron spectrometer or monochromator, and applications include neutron small angle scattering, crystallography, residual stress analysis, cross section measurements, and reflectometry. Presented are theory, experimental results, computer simulation, applications of the PMF, and comparison of its performance to Stern-Gerlach gradient devices and compound material and magnetic refractive prisms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptation of UVSOR-Type Plane-Grating Monochromator in Saga

The plane grating monochromator (PGM) is one of the most useful monochromators in the world. The design concept of the PGM originates from the characteristics of synchrotron radiation itself, namely parallel rays and small source size. Since the performance of the PGM depends on the beam emittance of the storage ring, it is expected that even the used PGM may be utilized in recent facility. Therefore, the UVSOR-type PGM that had been used for more than twenty years in UVSOR was adapted to the university's branch beamline in Saga-LS with several modifications. The performance tests were carried out with a photoelectron spectrometer, and the observed values were compared with the ray-tracing calculation. The results show that the adaptation of the UVSOR-type PGM is good enough to study new functional materials.

43 PARTICLE ACCELERATORS↗

Thermal gradient crystals as tuneable monochromator for high energy X-rays

At the high energy synchrotron radiation beamline BW5 at DORIS III at DESY a new monochromator providing broad energy bandwidth and high reflectivity is in use. On a small 10x10x5 mm{sup 3} silicon crystal scattering at the (311) reflection a thermal gradient is applied, which tunes the scattered energy bandwidth. The (311) reflection strongly suppresses the higher harmonics allowing the use of an image plate detector for crystallography. The monochromator can be used at photon energies above 60 keV.

43 PARTICLE ACCELERATORS↗

Analysis of order contamination from toroidal grating monochromator of Indus-1 reflectivity beamline

The synchrotron radiation spectra of toroidal grating monochromators (TGM) often contaminated by significant amounts of higher orders. Quantitative estimation of order contamination is essential in order to perform quantitative spectroscopy measurements. At Indus-1 reflectivity beamline higher order contaminations from TGM monochromator are experimentally determined using a reflection grating analyzer. It is found that the order contamination in wavelength range of 50-200 A is less than 15%. Use of edge filters reduces the order contamination level below 5% in this wavelength range.

43 PARTICLE ACCELERATORS↗

Quick-scanning x-ray absorption spectroscopy system with a servo-motor-driven channel-cut monochromator with a temporal resolution of 10 ms

We have developed a quick-scanning x-ray absorption fine structure (QXAFS) system and installed it at the recently constructed synchrotron radiation beamline BL33XU at the SPring-8. Rapid acquisition of high-quality QXAFS data was realized by combining a servo-motor-driven Si channel-cut monochromator with a tapered undulator. Two tandemly aligned monochromators with channel-cut Si(111) and Si(220) crystals covered energy ranges of 4.0-28.2 keV and 6.6-46.0 keV, respectively. The system allows the users to adjust instantly the energy ranges of scans, the starting angles of oscillations, and the frequencies. The channel-cut crystals are cooled with liquid nitrogen to enable them to withstand the high heat load from the undulator radiation. Deformation of the reflecting planes is reduced by clamping each crystal with two cooling blocks. Performance tests at the Cu K-edge demonstrated sufficiently high data quality for x-ray absorption near-edge structure and extended x-ray absorption fine-structure analyses with temporal resolutions of up to 10 and 25 ms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗