Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONOCHROMATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The EUV spectrophotometer on Atmosphere Explorer.

An extreme ultraviolet (EUV) spectrophotometer for measurements of solar radiation at wavelengths ranging from 140 to 1850 A will be included in the payload of each of the three Atmosphere-Explorer (AE) missions, AE-C, -D, and -E. The instrument consists of 24 grating monochromators, 12 of which can be telecommanded either to execute 128-step scans each covering a relatively small section of the total spectrophotometer wavelength range or to maintain fixed (command-selected) wavelength positions. The remaining 12 nonscan monochromators operate at permanently fixed wavelengths and view only a small fraction of the solar disk except for one viewing the whole sun in H Lyman alpha. Ten of the 12 scan-capable monochromators also view the entire solar disk since their primary function is to measure the total fluxes independent of the distribution of sources across the solar disk.

Hinteregger, H. E.↗

Fiber-Optic Coupler And Dynamic-Range Enhancer For CARS

Simpler equipment yields higher coupling efficiency with fewer adjustments. In improved scheme for coupling coherent anti-Stokes Raman spectroscopy (CARS) signal from measurement volume to monochromator, optical fiber and two lenses used in place of previous system. Cylindrical lenses focus light from optical fiber into beam of approximately rectangular cross section at input plane of monochromator. Optical wedge diverts part of beam in monochromator to produce less-intense secondary image.

Cutler, Andrew D.↗

Investigation of varying gray scale levels for remote manipulation

A study was conducted to investigate the effects of variant monitor gray scale levels and workplace illumination levels on operators' ability to discriminate between different colors on a monochrome monitor. It was determined that 8-gray scale viewing resulted in significantly worse discrimination performance compared to 16- and 32-gray scale viewing and that there was only a negligible difference found between 16 and 32 shades of gray. Therefore, it is recommended that monitors used while performing remote manipulation tasks have 16 or above shades of gray since this evaluation has found levels lower than this to be unacceptable for color discrimination task. There was no significant performance difference found between a high and a low workplace illumination condition. Further analysis was conducted to determine which specific combinations of colors can be used in conjunction with each other to ensure errorfree color coding/brightness discrimination performance while viewing a monochrome monitor. It was found that 92 three-color combination and 9 four-color combinations could be used with 100 percent accuracy. The results can help to determine which gray scale levels should be provided on monochrome monitors as well as which colors to use to ensure the maximal performance of remotely-viewed color discrimination/coding tasks.

Bierschwale, John M.↗

Reciprocal Space Mapping of Macromolecular Crystals in the Laboratory

The technique of reciprocal space mapping applied to the physical measurement of macromolecular crystals will be described. This technique uses a triple axis diffractometer setup whereby the monochromator is the first crystal, the sample is the second and the third crystal (of the same material as the monochromator) analyzes the diffracted beam. The geometry is such that it is possible to separate mosaic volume effects from lattice strain effects. The deconvolution of the instrument parameters will also be addressed. Results from measurements at Brookhaven National Synchrotron Radiation Source carried out on microgravity and ground-grown crystals will be presented. The required beam characteristics for reciprocal space mapping are also ideal for topographic studies and the first topographs ever recorded from microgravity protein crystal samples will be shown. We are now working on a system which will enable reciprocal space mapping, mosaicity and topography studies to be carried out in the home laboratory. This system uses a rotating anode X-ray source to provide an intense beam then a Bartels double crystal, four reflection monochromator to provide the spectral and geometric beam conditioning necessary such that the instrument characteristics do not mask the measurement. This is coupled to a high precision diffractometer and sensitive detector. Commissioning data and first results from the system will be presented.

Snell, Edward H.↗

Quantum Yield of Gold-Cathode Photomultipliers

Two gold-cathode EMI 6255G tubes have been investigated for their quantum yield between 3100 and 1900 A. The tubes had cathodes of different appearances. One of these, numbered 3012, had a slight bluish tinge and was very transparent to visible light; the other, numbered 3021, had a definite gold coloration. The relative quantum yield of each tube was determined with the aid of a Cary model 14 recording spectrophotometer used as a monochromator. The monochromator relative-energy output was determined from the current output of a sodium-salicylate-coated RCA 1P21 photomultiplier. Each gold-cathode tube was then operated at 3000 v, and the central 1.8 cm cube of the cathode was exposed to the monochromator output.

Childs, Charles B.↗

Spectral measurements by the filter method on Lewis' carbon arc solar simulators

There exists a problem in the measuring of the spectral irradiance of solar simulators. This difficulty has manifested intself in both monochromator and filter measurements. This report is the discussion of the measurements by Eppley Laboratory on the Lewis carbon arc solar Simulators, the further analysis of the method of filter radiometry made by Lewis personnel, and the comparison with the monochromator measurements. Previously when the filter technique was used it was assumed that the a priori knowledge of the source's spectral characteristics must be known. In this report it will be shown that for a carb0n arc source a knowledge of the source is not required after the filters have been properly chosen.

RADIOMETRY↗

Photoionization mass spectrometer

Photoionization source with a vacuum UV monochromator is used in ion reaction kinetics. Monochromator passes only the photon energies near the threshold of the selected ionization process. Absence of electron impact alleviates creation of different type ions that result in ion fragmentation.

Warneck, P.↗

Task 2 of the ultraviolet spectrometer experiment S169

The far ultraviolet spectrometer for the Apollo 17 lunar scientific mission was constructed to meet the specific requirements and technical specifications as directed by the National Aeronautics and Space Administration. The Ebert Scanning Monochromator (UVS) was derived from extensive experience in the development of a variety of Ebert scanning monochromators for experiments aboard rockets and satellites. This equipment has the capability to make quantitative measurements of the composition of the lunar atmosphere as seen from the Apollo 17 CSM in lunar orbit, and to study the spectra of a number of astronomical sources during trans-earth coast.

Goss, M. E.↗

Study of resonance light scattering for remote optical probing

Enhanced scattering and fluorescence processes in the visible and UV were investigated which will enable improved remote measurements of gas properties. The theoretical relationship between scattering and fluorescence from an isolated molecule in the approach to resonance is examined through analysis of the time dependence of re-emitted light following excitation of pulsed incident light. Quantitative estimates are developed for the relative and absolute intensities of fluorescence and resonance scattering. New results are obtained for depolarization of scattering excited by light at wavelengths within a dissociative continuum. The experimental work was performed in two separate facilities. One of these utilizes argon and krypton lasers, single moded by a tilted etalon, and a 3/4 meter double monochromator. This facility was used to determine properties of the re-emission from NO2, I2 and O3 excited by visible light. The second facility involves a narrow-line dye laser, and a 3/4 meter single monochromator. The dye laser produces pulsed light with 5 nsec pulse duration and 0.005 nm spectral width.

Penney, C. M.↗

Model for interpreting Doppler broadened optical line emission measurements on axially symmetric plasma

A plasma model, previously developed to interpret neutral-particle analyzer measurements on E x B heating devices, is adapted to analyze Doppler broadened charge-exchange-neutral lines measured by an optical monochromator. Comparison of theoretical with experimental results indicates that azimuthal drift as well as cyclotron motion are quite influential in determining line shapes and widths, and thus important in temperature determination, even when the monochromator line of sight is intersecting the plasma axis of symmetry. At this central sighting position, however, results are quite insensitive to radial ion density distribution when time lag between the charge-exchange-excitation events and emission is neglected. Line shapes and widths obtained by sighting across chords of plasma at various distances from the plasma axis of symmetry indicate a strong dependence on time lag.

Englert, G. W.↗

Total ozone determination by spectroradiometry in the middle ultraviolet

A method has been developed to determine total ozone from multispectral measurements of the direct solar irradiance. The total ozone is determined by a least squares fit to the spectrum between 290 nm and 380 nm. The aerosol extinction is accounted for by expanding it in a power series in wavelength; use of the linear term proved adequate. A mobile laboratory incorporating a sky scanner has been developed and used to obtain data to verify the method. Sun tracking, wavelength setting of the double monochromator, and data acquisition are under control of a minicomputer. Results obtained at Wallops Island, Virginia, and Palestine, Texas, agree well with simultaneous Dobson and Canterbury spectrometer and balloon ECC ozonesonde values. The wavelength calibration of the monochromator and the values for the normalized ozone absorption are the most important factors in an accurate determination of total ozone.

Garrison, L. M.↗

Shuttle Orbiter solid-state television camera

The Shuttle closed-circuit TV system incorporates a mix of monochrome TV cameras (in the payload bay for operations support purposes) and color cameras (in the crew cabin for crew activity monitoring purposes). These cameras currently employ glass enclosed, vacuum processed image sensors. A camera that uses a solid-state image sensor offers many extremely attractive advantages. This paper presents the current status of development of solid-state television cameras - monochrome and NTSC color - for use in various aspects of the Space Shuttle program. Results of in depth design and testing programs are discussed as well as the plans for employing these cameras in the Shuttle program.

Embrey, B. C., Jr.↗

Laser measurement of the spectral extinction coefficients of fluorescent, highly absorbing liquids

A conceptual method is developed to deduce rapidly the spectral extinction coefficient of fluorescent, highly absorbing liquids, such as crude or refined petroleum oils. The technique offers the advantage of only requiring one laser wavelength and a single experimental assembly and execution for any specific fluorescent liquid. The liquid is inserted into an extremely thin wedge-shaped cavity for stimulation by a laser from one side and flurescence measurement on the other side by a monochromator system. For each arbitrarily selected extinction wavelength, the wedge is driven slowly to increasing thicknesses until the fluorescence extinguishes. The fluorescence as a function of wedge thickness permits a determination of the extinction coefficient using an included theoretical model. When the monochromator is set to the laser emission wavelength, the extinction coefficient is determined using the usual on-wavelength signal extinction procedure.

Hoge, F. E.↗

Imaging Spectrometer for Geophysical Surveys

Airborne spectrometer combines technologies of television imaging and spectroscopy to produce data for geophysical surveys, agricultural assessments, forest and land management, and exploration for oil and minerals. Designed for Small Size, infrared imaging spectrometer uses folded telescope and passes input and output of its monochromator through hole in monochromator grating. Instrument permits analysis of terrain at many infrared wavelengths.

Labaw, C. C.↗

Optical Integrating Sphere for Vacuum Ultraviolet

Optical integrating sphere with integral sliding sample holder saves time by allowing radiometric measurements made on each of four samples without breaking vacuum. Designed to operate with interior evacuated so dye samples illuminated with short-wavelength ultraviolet strongly absorbed by air; need not be evacuated when using longer wavelengths. Device mounts on monochromator and evacuated through port that admits light from monochromator.

Butner, C. L.↗

Vertical ozone profile determination from Nimbus-7 SBUV measurements

An inversion algorithm is presented, which is used to process Nimbus-7 solar backscattered UV (SBUV) data collected between November 1978 and October 1980. The SBUV experiment utilizes a double monochromator in the nadir position which measures the backscattered solar radiation in twelve 1-nm bands; a separate photometer measures the radiance at 343.0 nm in the field of view coincident with the monochromator. The primary output of the inversion is the total ozone content in umkehr layers in units of m atm cm. In addition, the diagonal elements of the covariance matrix are reported; they represent the uncertainty in the derived ozone content in each layer. The solution covariance is noted to be independent of the measurements.

Klenk, K. F.↗

The detection and interpretation of long-term changes in ozone from space

Long-term measurements of backscattered ultraviolet radiances, now being acquired by orbiting monochromators, will provide the basis for seeking trends in atmospheric ozone. The unambiguous detection of ozone trends on decadal time scales demands a data set that is essentially free of instrument drifts. Periodic flights of an ultraviolet monochromator on the space shuttle will provide an independent means of evaluating the long-term stability of identical instruments operating on free-flying satellites. A successful calibration of the free-flying sensors using the shuttle instrument places strict demands on calibration repeatability from one flight to the next. In addition, spatial and temporal variability in cloud cover could pose further complications in carrying out these in-flight calibrations.

Frederick, John E.↗

The detection and interpretation of long-term changes in ozone from space

Long-term measurements of backscattered ultraviolet radiances, now being acquired by orbiting monochromators, will provide the basis for seeking trends in atmospheric ozone. The unambiguous detection of ozone trends on decadal time scales demands a data set that is essentially free of instrument drifts. Periodic flights of an ultraviolet monochromator on the space shuttle will provide an independent means of evaluating the long-term stability of identical instruments operating on free-flying satellites. A successful calibration of the free-flying sensors using the shuttle instrument places strict demands on calibration repeatability from one flight to the next. In addition, spatial and temporal variability in cloud cover could pose further complications in carrying out these in-flight calibrations.

Frederick, John E.↗