X-ray monochromator

An x-ray monochromator is described, wherin a housing supports a plurality of mirrors forming a plurality of opposed mirror faces in parallel with each other and having thereon multilayer coatings, with each of said pairs of mirror faces being provided with identical coatings which are different from the coatings on the other pairs of mirror faces such that each pair of mirror faces has a peak x-ray reflection at a different wavelength regime. The housing is moveable to bring into a polychromatic x-ray beam that pair of mirror faces having the best x-ray reflection for the desired wavelength, with the mirrors being pivotable to move the mirror faces to that angle of incidence at which the peak reflectivity of the desired wavelength x-rays occurs.

Hoover, Richard B.↗

Portable color multimedia training systems based on monochrome laptop computers (CBT-in-a-briefcase), with spinoff implications for video uplink and downlink in spaceflight operations

This report describes efforts to use digital motion video compression technology to develop a highly portable device that would convert 1990-91 era IBM-compatible and/or MacIntosh notebook computers into full-color, motion-video capable multimedia training systems. An architecture was conceived that would permit direct conversion of existing laser-disk-based multimedia courses with little or no reauthoring. The project did not physically demonstrate certain critical video keying techniques, but their implementation should be feasible. This investigation of digital motion video has spawned two significant spaceflight projects at MSFC: one to downlink multiple high-quality video signals from Spacelab, and the other to uplink videoconference-quality video in realtime and high quality video off-line, plus investigate interactive, multimedia-based techniques for enhancing onboard science operations. Other airborne or spaceborne spinoffs are possible.

Scott, D. W.↗

High Precision, Absolute Total Column Ozone Measurements from the Pandora Spectrometer System: Comparisons with Data from a Brewer Double Monochromator and Aura OMI

We present new, high precision, high temporal resolution measurements of total column ozone (TCO) amounts derived from ground-based direct-sun irradiance measurements using our recently deployed Pandora single-grating spectrometers. Pandora's small size and portability allow deployment at multiple sites within an urban air-shed and development of a ground-based monitoring network for studying small-scale atmospheric dynamics, spatial heterogeneities in trace gas distribution, local pollution conditions, photochemical processes and interdependencies of ozone and its major precursors. Results are shown for four mid- to high-latitude sites where different Pandora instruments were used. Comparisons with a well calibrated double-grating Brewer spectrometer over a period of more than a year in Greenbelt MD showed excellent agreement and a small bias of approximately 2 DU (or, 0.6%). This was constant with slant column ozone amount over the full range of observed solar zenith angles (15-80), indicating adequate Pandora stray light correction. A small (1-2%) seasonal difference was found, consistent with sensitivity studies showing that the Pandora spectral fitting TCO retrieval has a temperature dependence of 1% per 3K, with an underestimation in temperature (e.g., during summer) resulting in an underestimation of TCO. Pandora agreed well with Aura-OMI (Ozone Measuring Instrument) satellite data, with average residuals of <1% at the different sites when the OMI view was within 50 km from the Pandora location and OMI-measured cloud fraction was <0.2. The frequent and continuous measurements by Pandora revealed significant short-term (hourly) temporal changes in TCO, not possible to capture by sun-synchronous satellites, such as OMI, alone.

Ozone↗

Polarized vacuum ultraviolet and X-radiation

The most intense source of polarized vacuum UV and X radiation is synchrotron radiation, which exhibits a degree of partially polarized light between about 80-100%. However, the radiation transmitted by vacuum UV monochromators can also be highly polarized. The Seya-Namioka type of monochromator can produce partially polarized radiation between 50-80%. For certain experiments it is necessary to know the degree of polarization of the radiation being used. Also, when synchrotron radiation and a monochromator are combined the polarization characteristic of both should be known in order to make full use of these polarization properties. The polarizing effect of monochromators (i.e., diffraction gratings) have been measured at the Seya angle and at grazing angles for various spectral orders. Experimental evidence is presented which shows that the reciprocity law holds for polarization by reflection where the angle of incidence and diffraction are unequal. These results are reviewed along with the techniques for measuring the degree of polarization.

Samson, J. A. R.↗

Design and Optimization of the Proposed NB2 Guide System in the HFIR Cold Guide Hall

The NB2 Guide Design is used to provide a defined neutron beam flux to at least one monochromator and an end station. The known monochromator configuration will support a sample alignment station and the end station will be able to accommodate either a neutron polarization development instrument or a spin echo neutron spectrometer, as well as the potential for additional monochromators along the guide path. The design proposed will meet the needs specified for those instruments defined by science requirements documents, and will also provide insight into potential opportunities for future instrument developments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The EUV spectrophotometer on Atmosphere Explorer.

An extreme ultraviolet (EUV) spectrophotometer for measurements of solar radiation at wavelengths ranging from 140 to 1850 A will be included in the payload of each of the three Atmosphere-Explorer (AE) missions, AE-C, -D, and -E. The instrument consists of 24 grating monochromators, 12 of which can be telecommanded either to execute 128-step scans each covering a relatively small section of the total spectrophotometer wavelength range or to maintain fixed (command-selected) wavelength positions. The remaining 12 nonscan monochromators operate at permanently fixed wavelengths and view only a small fraction of the solar disk except for one viewing the whole sun in H Lyman alpha. Ten of the 12 scan-capable monochromators also view the entire solar disk since their primary function is to measure the total fluxes independent of the distribution of sources across the solar disk.

Hinteregger, H. E.↗

Fiber-Optic Coupler And Dynamic-Range Enhancer For CARS

Simpler equipment yields higher coupling efficiency with fewer adjustments. In improved scheme for coupling coherent anti-Stokes Raman spectroscopy (CARS) signal from measurement volume to monochromator, optical fiber and two lenses used in place of previous system. Cylindrical lenses focus light from optical fiber into beam of approximately rectangular cross section at input plane of monochromator. Optical wedge diverts part of beam in monochromator to produce less-intense secondary image.

Cutler, Andrew D.↗

Investigation of varying gray scale levels for remote manipulation

A study was conducted to investigate the effects of variant monitor gray scale levels and workplace illumination levels on operators' ability to discriminate between different colors on a monochrome monitor. It was determined that 8-gray scale viewing resulted in significantly worse discrimination performance compared to 16- and 32-gray scale viewing and that there was only a negligible difference found between 16 and 32 shades of gray. Therefore, it is recommended that monitors used while performing remote manipulation tasks have 16 or above shades of gray since this evaluation has found levels lower than this to be unacceptable for color discrimination task. There was no significant performance difference found between a high and a low workplace illumination condition. Further analysis was conducted to determine which specific combinations of colors can be used in conjunction with each other to ensure errorfree color coding/brightness discrimination performance while viewing a monochrome monitor. It was found that 92 three-color combination and 9 four-color combinations could be used with 100 percent accuracy. The results can help to determine which gray scale levels should be provided on monochrome monitors as well as which colors to use to ensure the maximal performance of remotely-viewed color discrimination/coding tasks.

Bierschwale, John M.↗

Reciprocal Space Mapping of Macromolecular Crystals in the Laboratory

The technique of reciprocal space mapping applied to the physical measurement of macromolecular crystals will be described. This technique uses a triple axis diffractometer setup whereby the monochromator is the first crystal, the sample is the second and the third crystal (of the same material as the monochromator) analyzes the diffracted beam. The geometry is such that it is possible to separate mosaic volume effects from lattice strain effects. The deconvolution of the instrument parameters will also be addressed. Results from measurements at Brookhaven National Synchrotron Radiation Source carried out on microgravity and ground-grown crystals will be presented. The required beam characteristics for reciprocal space mapping are also ideal for topographic studies and the first topographs ever recorded from microgravity protein crystal samples will be shown. We are now working on a system which will enable reciprocal space mapping, mosaicity and topography studies to be carried out in the home laboratory. This system uses a rotating anode X-ray source to provide an intense beam then a Bartels double crystal, four reflection monochromator to provide the spectral and geometric beam conditioning necessary such that the instrument characteristics do not mask the measurement. This is coupled to a high precision diffractometer and sensitive detector. Commissioning data and first results from the system will be presented.

Snell, Edward H.↗

Quantum Yield of Gold-Cathode Photomultipliers

Two gold-cathode EMI 6255G tubes have been investigated for their quantum yield between 3100 and 1900 A. The tubes had cathodes of different appearances. One of these, numbered 3012, had a slight bluish tinge and was very transparent to visible light; the other, numbered 3021, had a definite gold coloration. The relative quantum yield of each tube was determined with the aid of a Cary model 14 recording spectrophotometer used as a monochromator. The monochromator relative-energy output was determined from the current output of a sodium-salicylate-coated RCA 1P21 photomultiplier. Each gold-cathode tube was then operated at 3000 v, and the central 1.8 cm cube of the cathode was exposed to the monochromator output.

Childs, Charles B.↗

DXRD : a user-friendly suite of two- and multiple-beam dynamical X-ray diffraction programs

The DXRD program suite consisting of a series of dynamical theory programs is introduced for computing dynamical X-ray diffraction from single crystals. Its interactive graphical user interfaces (GUIs) allow general users to make complicated calculations with minimal effort. It can calculate plane-wave Darwin curves of single crystals (or multiple crystals) for both the Bragg and Laue cases, including grazing-incidence diffraction and backward diffraction (with Bragg angles approaching 90°). It is also capable of simulating rocking curves for divergent incident X-ray beams with finite bandwidths. A unique feature of DXRD is that it provides a convenient GUI-based multiple-beam diffraction program that can accurately compute arbitrary N-beam diffraction of any geometry using a universal 4N × 4N matrix method. DXRD also provides a mapping program for plotting all the multiple-beam diffraction lines (monochromator glitches) in the azimuth–energy coordinate system. All these functions make DXRD a convenient and powerful software tool for designing crystal-based synchrotron/X-ray optics (monochromators, analyzers, polarizers, phase plates etc.) and for crystal characterization, X-ray spectroscopy and X-ray diffraction teaching.

Bragg reflection↗

Calibrating cryogenic temperature of TEM specimens using EELS

Cryogenic Scanning/Transmission Electron Microscopy has been established as a leading method to image sensitive biological samples and is now becoming a powerful tool to understand materials' behavior at low temperatures. However, achieving precise local temperature calibration at low temperatures remains a challenge, which is especially crucial for studying phase transitions and emergent physical properties in quantum materials. In this study, we employ electron energy loss spectroscopy (EELS) to measure local cryogenic specimen temperatures. Here we use the temperature-dependent characteristics of aluminum's bulk plasmon peak in EEL spectra, which shifts due to changes in electron density caused by thermal expansion and contraction. We successfully demonstrate the versatility of this method by calibrating different liquid nitrogen cooling holders in various microscopes, regardless of whether a monochromated or non-monochromated electron beam is used. Temperature discrepancies between the actual temperature and the setpoint temperatures are identified across a range from room temperature to 100 K. This work demonstrates the importance of temperature calibrations at intermediate temperatures and presents a straightforward, robust method for calibrating local temperatures of cryogenically-cooled specimens in electron microscopes.

36 MATERIALS SCIENCE↗

Spectral measurements by the filter method on Lewis' carbon arc solar simulators

There exists a problem in the measuring of the spectral irradiance of solar simulators. This difficulty has manifested intself in both monochromator and filter measurements. This report is the discussion of the measurements by Eppley Laboratory on the Lewis carbon arc solar Simulators, the further analysis of the method of filter radiometry made by Lewis personnel, and the comparison with the monochromator measurements. Previously when the filter technique was used it was assumed that the a priori knowledge of the source's spectral characteristics must be known. In this report it will be shown that for a carb0n arc source a knowledge of the source is not required after the filters have been properly chosen.

RADIOMETRY↗

Photoionization mass spectrometer

Photoionization source with a vacuum UV monochromator is used in ion reaction kinetics. Monochromator passes only the photon energies near the threshold of the selected ionization process. Absence of electron impact alleviates creation of different type ions that result in ion fragmentation.

Warneck, P.↗

Task 2 of the ultraviolet spectrometer experiment S169

The far ultraviolet spectrometer for the Apollo 17 lunar scientific mission was constructed to meet the specific requirements and technical specifications as directed by the National Aeronautics and Space Administration. The Ebert Scanning Monochromator (UVS) was derived from extensive experience in the development of a variety of Ebert scanning monochromators for experiments aboard rockets and satellites. This equipment has the capability to make quantitative measurements of the composition of the lunar atmosphere as seen from the Apollo 17 CSM in lunar orbit, and to study the spectra of a number of astronomical sources during trans-earth coast.

Goss, M. E.↗

Study of resonance light scattering for remote optical probing

Enhanced scattering and fluorescence processes in the visible and UV were investigated which will enable improved remote measurements of gas properties. The theoretical relationship between scattering and fluorescence from an isolated molecule in the approach to resonance is examined through analysis of the time dependence of re-emitted light following excitation of pulsed incident light. Quantitative estimates are developed for the relative and absolute intensities of fluorescence and resonance scattering. New results are obtained for depolarization of scattering excited by light at wavelengths within a dissociative continuum. The experimental work was performed in two separate facilities. One of these utilizes argon and krypton lasers, single moded by a tilted etalon, and a 3/4 meter double monochromator. This facility was used to determine properties of the re-emission from NO2, I2 and O3 excited by visible light. The second facility involves a narrow-line dye laser, and a 3/4 meter single monochromator. The dye laser produces pulsed light with 5 nsec pulse duration and 0.005 nm spectral width.