Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Flight-Test Approach for X-57 Mod II Configuration

The primary objective of the X-57 Mod II test flights is to perform a functional checkout of the research traction battery power and motor systems, perform an airworthiness assessment of the modified vehicle, and to collect baseline performance, stability, and acoustic data for comparisons with later modifications of the X-57 airplane. This paper describes the planned flight operations of the Mod II airplane, the unique considerations and decisions made in operating an electric aircraft, and the development and planning of the research test points necessary to achieve the Mod II flight objectives. Due to the constrained flight time, which resulted from limited capacity of the battery system, careful scripting of flights was required to maximize test time and execute test points efficiently.

James Reynolds

The low frequency edge oscillation in alcator C-Mod and ASDEX upgrade I-mode

The low frequency edge oscillation (LFEO) is a low frequency fluctuation in many plasma quantities in the pedestal region of the I-Mode confinement regime. It is observed on Alcator C-Mod between 10–30 kHz and on ASDEX Upgrade between 5–10 kHz. On both tokamaks it has been previously identified as a geodesic acoustic mode (GAM), however the recent discovery of the edge temperature ring oscillation (ETRO) in a similar frequency and spatial location as the LFEO in I-Modes on EAST has called this identification into question. In this paper we investigate the LFEO on C-Mod and AUG using a variety of different experimental techniques including spectral analysis, magnetic mode number analysis, localization, and direct measurement of the LFEO zonal structure and propagation using a mirror Langmuir probe. This investigation has reconfirmed the identification of the LFEO as a GAM and determined that it has several key differences from the ETRO.

AUG

Mitigation of ICRF—edge plasma interaction in Alcator C-Mod

The parasitic interaction between ion cyclotron range of frequencies (ICRF) waves and the edge plasma has long limited high-power ICRF utilization in magnetically confined fusion plasmas. In this paper, we report on the successful mitigation of this interaction by power tapering a four-strap field-aligned (FA) antenna in the Alcator C-Mod tokamak. With the antenna operated in dipole phasing ($0\pi0\pi$), the ratio of the power coupled by the central two straps ($P_\mathrm {cent}$) to the power coupled by the outer two straps was varied at fixed total coupled ICRF power ($P_\mathrm {tot}$). With $P_\mathrm {cent}$/$P_\mathrm {tot} \approx 0.8-0.9$, no enhancement of the plasma potential was measured despite 1 MW of coupled ICRF power. When the antenna is powered, energy deposition increases on its four corners and on neighboring limiter tiles magnetically connected to some of those corners. The energy deposited on the antenna and limiter is minimized together with near-field plasma potentials. Additionally, we show that deviation from $P_\mathrm {cent}$/$P_\mathrm {tot} \approx 0.8$ enhances wave-plasma interactions in places not magnetically connected to the antenna. These far-field effects are correlated with changes in the antenna spectrum. Hence, on C-Mod, near-field and far-field interactions were minimized for about the same range of $P_\mathrm {cent}$/$P_\mathrm {tot}$. Optimal power tapering was also found to improve ICRF heating efficiency and facilitate H-mode access. Finally, we show that the heat flux pattern on the toroidally aligned antennas reverses with the direction of the RF-induced E×B flow in front of the antenna, a correlation not observed for the FA antenna. We argue that the RF-induced E×B flow, which carries high-density plasma from the near-SOL, is aligned with the FA antenna and does not intercept its corners, where the plasma potential is large. This could explain the previously reported smaller impurity generation by the FA antenna (Wukitch et al 2013 Phys. Plasmas 20 056117).

Alcator C-Mod

Gain stability of Hamamatsu R5912-MOD photomultipliers at low temperature

The Photon Detection System (PDS) is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 PhotoMultiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operating at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu R5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70 °C, although this temperature is rather higher than that of the liquid Argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Enhanced pedestal transport driven by edge collisionality on Alcator C-Mod and its role in regulating H-mode pedestal gradients

Experimental measurements of plasma and neutral profiles across the pedestal are used in conjunction with 2D edge modeling to examine pedestal stiffness in Alcator C-Mod H-mode plasmas. Enhanced D α experiments on Alcator C-Mod observed pedestal degradation and loss in confinement below a critical value of net power crossing the separatrix, P net = $P^{crit}_{net}$ ≈ 2.3 MW, in the absence of any external fueling. New analysis of ionization and particle flux profiles reveal saturation of the pedestal electron density, $n^{ped}_{e}$, despite continuous increases in ionization throughout the pedestal, inversely related to P net . A limi to the pedestal $\nabla$n e emerges as the particle flux, Γ D , continues to grow, implying increases in the effective particle diffusivity, D eff . This is well-correlated with the separatrix collisionality, $v^*_{sep}$ and a turbulence control parameter, α t , implying a possible transition in type of turbulence. The transition is well correlated with the experimentally observed value of $P^{crit}_{net}$. SOLPS-ITER modeling is performed for select discharges from the power scan, constrained with experimental electron and neutral densities, measured at the outer midpane. The modeling confirms general growth in D eff , consistent with experimental findings, and additionally suggests even larger growth in Χ e at the same $P^{crit}_{net}$.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

MOD-1 WTG dynamic analysis

An analysis of the MOD-1 2000 kW horizontal axis wind turbine was given. The MOD-1 design was briefly described, and the analysis used to evaluate the dynamic loads and structural interactions is discussed. The resonant frequency placement, the treatment of unsteady wind loading, and the dynamic load sensitivity to frequency shifts were reviewed for the design.

Stahle, C. V., Jr.

Mod-1 Wind Turbine Generator Analysis

A general summary of the MOD-1 wind turbine generator control system and simulation is presented. Mechanical and speed stabilization control means to add drive train damping were mentioned and MOD-1 simulation results showing the effects of speed stabilization are displayed.

Barton, R. S.

Utility operational experience on the NASA/DOE MOD-0A 200-kW wind turbine

The Mod-0A 200 wind turbine was designed and fabricated as part of the Federal Wind Energy Program. Early wind turbine operation and performance data were obtained while gaining initial experience in the operation of large, horizontal axis wind turbines in typical utility environments. The Mod-0A wind turbine was turned over to the Town of Clayton Light and Water Plant, Clayton, NM, for utility operation and on December 31, 1978, the machine had completed ten months of utility operation. The machine is described and the recent operational experience at Clayton, NMis documented.

Glasgow, J. C.

Design and operating experience on the U.S. Department of Energy Experimental Mod-O 100 kW Wind Turbine

The Mod-O 100 kW Experimental Wind Turbine was designed and fabricated by NASA, as part of the Federal Wind Energy Program, to assess technology requirements and engineering problems of large wind turbines. The machine became operational in October 1975 and has demonstrated successful operation in all of its design modes. During the course of its operations the machine has generated a wealth of experimental data and has served as a prototype developmental test bed for the Mod-OA operational wind turbines which are currently used on utility networks. This paper describes the mechanical and control systems as they evolved in operational tests and describes some of the experience with various systems in the downwind rotor configuration.

Glasgow, J. C.

DOE/NASA Mod-OA wind turbine performance

The NASA Lewis Research Center has designed, built, and is operating a 200-kW wind turbine (designated the Mod-OA-1) at Clayton, New Mexico. This paper compares the measured power-vs-speed performance of the Mod-OA-1 with predictions made using the PROP code. It is found that the actual performance closely matches predictions.

Richards, T. R.

Background and system description of the Mod 1 wind turbine generator

The Mod-1 wind turbine considered is a large utility-class machine, operating in the high wind regime, which has the potential for generation of utility grade power at costs competitive with other alternative energy sources. A Mod-1 wind turbine generator (WTG) description is presented, taking into account the two variable-pitch steel blades of the rotor, the drive train, power generation/control, the Nacelle structure, and the yaw drive. The major surface elements of the WTG are the ground enclosure, the back-up battery system, the step-up transformer, elements of the data system, cabling, area lighting, and tower foundation. The final system weight (rotor, Nacelle, and tower) is expected to be about 650,000 pounds. The WTG will be capable of delivering 1800 kW to the utility grid in a wind-speed above 25 mph.

Ernst, E. H.

Utility operational experience on the NASA/DOE Mod-OA 200 kW Wind Turbine

The Mod-OA 200 kW Wind Turbine was designed and fabricated by the Lewis Research Center of the NASA under the direction of the U.S. Department of Energy. The project is a part of the Federal Wind Energy Program and is designed to obtain early wind turbine operation and performance data while gaining initial experience in the operation of large, horizontal axis wind turbines in typical utility environments. On March 6, 1978, the Mod-OA wind turbine was turned over to the Town of Clayton Light and Water Plant, Clayton, NM, for utility operation and on December 31, 1978 the machine had completed ten months of utility operation. This paper describes the machine and documents the recent operational experience at Clayton, NM.

Glasgow, J. C.

The MOD-1 steel blade

The design, development, fabrication, testing, and transport of two 100 foot metal blades for the MOD-1 WTS are summarized. Because the metal blade design was started late in the MOD-1 system development, many of the design requirements (allocations) were restrictive for the metal blade concept, particularly the maximum weight requirement. The design solutions required to achieve the weight goal resulted in a labor intensive (expensive) fabrication, particularly for a quantity of only two blades manufactured using minimal tooling.

Vanbronkhorst, J.

Preliminary analysis of performance and loads data from the 2-megawatt mod-1 wind turbine generator

Preliminary test data on output power versus wind speed, rotor blade loads, system dynamic behavior, and start-stop characteristics on the Mod-1 wind turbine generator are presented. These data were analyzed statistically and are compared with design predictions of system performance and loads. To date, the Mod-1 wind turbine generator has produced up to 1.5 MW of power, with a measured power versus wind speed curve which agrees closely with design. Blade loads were measured at wind speeds up to 14 m/s and also during rapid shutdowns. Peak transient loads during the most severe shutdowns are less than the design limit loads. On the inboard blade sections, fatigue loads are approximately equal to the design cyclic loads. On the outboard blade sections, however, measured cyclic loads are significantly larger than design values, but they do not appear to exceed fatigue allowable loads as yet.

Spera, D. A.

Installation and checkout of the DOE/NASA Mod-1 2000-kW wind turbine generator

The paper describes the DOE/NASA Mod-1 wind turbine generator, its assembly and testing, and its installation at Boone, North Carolina. The paper concludes with performance data taken during the initial tests conducted on the machine. The successful installation and initial operation of the Mod-1 wind turbine generator has had the following results: (1) megawatt-size wind turbines can be operated satisfactorily on utility grids; (2) the structural loads can be predicted by existing codes; (3) assembly of the machine on top of the tower presents no major problem; (4) large blades 100 ft long can be transported long distances and over mountain roads; and (5) operating experience and performance data will contribute substantially to the design of future low-cost wind turbines.

Puthoff, R. L.