Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MKIDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

52 records · Page 3

Simulating the Phonon Collection Efficiency in KIPMDs

Kinetic inductance phonon-mediated (KIPM) detectors are superconducting microcalorimeters that use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the device substrate. In order to improve the design of these detectors, we need to understand the effect of various detector design elements on the physical processes that take place within the detector through simulation efforts. One figure of merit for KIPM detectors is the phonon collection efficiency, $\eta_{ph]$, defined as the ratio of phonon energy detected by the sensitive element in the detector and the energy deposited by incident phonons in the substrate. Comparing the phonon collection efficiency obtained in simulation and in experiment for the same detector geometry provides insight to physical processes in the detector, such as phonon absorption at substrate-sensor interfaces and phonon loss to non-sensitive detector elements. This work models the phonon collection efficiency in two KIPM detectors with different geometries, one located at the Fermi National Accelerator Laboraory, the other located at the SLAC National Accelerator Laboratory.

Dang, Stella Q.↗

Mu-Spec - A High Performance Ultra-Compact Photon Counting spectrometer for Space Submillimeter Astronomy

We have designed and are testing elements of a fully integrated submillimeter spectrometer based on superconducting microstrip technology. The instrument can offer resolving power R approximately 1500, and its high frequency cutoff is set by the gap of available high performance superconductors. All functions of the spectrometer are integrated - light is coupled to the microstrip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using planar filter, and detected using photon counting MKID detector. This spectrometer promises to revolutionize submillimeter spectroscopy from space. It replaces instruments with the scale of 1m with a spectrometer on a 10 cm Si wafer. The reduction in mass and volume promises a much higher performance system within available resource in a space mission. We will describe the system and the performance of the components that have been fabricated and tested.

Moseley, H.↗

NASA Tech Briefs, May 2012

Topics covered include: An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently; On-Wafer Measurement of a Multi-Stage MMIC Amplifier with 10 dB of Gain at 475 GHz; Software to Control and Monitor Gas Streams; Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column; Anomaly Detection in Test Equipment via Sliding Mode Observers; Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems; Goldstone Solar System Radar Waveform Generator; Fast and Adaptive Lossless Onboard Hyperspectral Data Compression System; Iridium Interfacial Stack - IrIS; Downsampling Photodetector Array with Windowing; Optical Phase Recovery and Locking in a PPM Laser Communication Link; High-Speed Edge-Detecting Line Scan Smart Camera; Optical Communications Channel Combiner; Development of Thermal Infrared Sensor to Supplement Operational Land Imager; Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Histogrammatic Method for Determining Relative Abundance of Input Gas Pulse; Predictive Sea State Estimation for Automated Ride Control and Handling - PSSEARCH; LEGION: Lightweight Expandable Group of Independently Operating Nodes; Real-Time Projection to Verify Plan Success During Execution; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Web-Based Customizable Viewer for Mars Network Overflight Opportunities; Fabrication of a Cryogenic Terahertz Emitter for Bolometer Focal Plane Calibrations; Fabrication of an Absorber-Coupled MKID Detector; Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays; Method of Bonding Optical Elements with Near-Zero Displacement; Free-Mass and Interface Configurations of Hammering Mechanisms; Wavefront Compensation Segmented Mirror Sensing and Control; Long-Life, Lightweight, Multi-Roller Traction Drives for Planetary Vehicle Surface Exploration; Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications; Electrochemical Ultracapacitors Using Graphitic Nanostacks; Improved Whole-Blood-Staining Device; Monitoring Location and Angular Orientation of a Pill; Molecular Technique to Reduce PCR Bias for Deeper Understanding of Microbial Diversity; Laser Ablation Electrodynamic Ion Funnel for In Situ Mass Spectrometry on Mars; High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle; PRTs and Their Bonding for Long-Duration, Extreme-Temperature Environments; Mid- and Long-IR Broadband Quantum Well Photodetector; 3D Display Using Conjugated Multiband Bandpass Filters; Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow; Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators; Dual-Compartment Inflatable Suitlock; Large-Strain Transparent Magnetoactive Polymer Nanocomposites; Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine; Time Distribution Using SpaceWire in the SCaN Testbed on ISS; and Techniques for Solution- Assisted Optical Contacting.

Source record↗

Mu-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the Mu-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the microstrip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Micro-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the micro-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the micro strip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

Wollack, Edward↗

Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

Far-infrared↗

Properties of Superconducting Mo, Mo2n and Trilayer Mo2n-Mo-Mo2n Thin Films

We present measurements of the properties of thin film superconducting Mo, Mo2N and Mo2N/Mo/Mo2N trilayers of interest for microwave kinetic inductance detector (MKID) applications. Using microwave resonator devices, we investigate the transition temperature, energy gaps, kinetic inductance, and internal quality factors of these materials. We present an Usadel-based interpretation of the trilayer transition temperature as a function of trilayer thicknesses, and a 2-gap interpretation to understand the change in kinetic inductance and internal resonance quality factor (Q) as a function of temperature.

Superconducting↗

The Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument which will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning \exclaimz. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (µ-Spec) coupled to microwave kinetic inductance detectors (MKIDs). Here we present an overview of the EXCLAIM instrument design and status.

Instrumentation and Photography↗

EXCLAIM: A New Balloon Mission to Map the Cosmological History of Galaxies

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (micro-spec) coupled to microwave kinetic inductance detectors (MKIDs). I will present an overview of the EXCLAIM instrument design and status.

Eric Switzer↗

Low-Loss Thin-Film Al-On-Si Microwave Resonators for Astronomy Applications Designing and Characterizing the Next Generation of Microwave Detectors

We present measurements of prototype thin film Al microwave kinetic inductance detectors (MKIDs) intended for application in the sub-mm astronomy balloon experiment EXCLAIM. The device we show is dark, or non-optically coupled, and contains 16 coplanar waveguide (CPW) resonators etched into a 261 nm sputter deposited Al layer on a Si wafer. The resonators span the f0 = 3.5 - 4 GHz range, and include both lambda=2 and lambda=4 resonators. Each resonator is coupled to the feedline using one of three alternating coupling designs. We performed transmission line measurements of the device for a series of excitation powers ranging from -90 dBm to -30 dBm, and at a series of base temperatures ranging from 73 mK to 400 mK. We observed quality factors of up to Qi  107 at a base temperature of 73 mK. The lambda=2 and lambda=4 resonators performed similarly, achieving comparable Qi values. The results of these measurements are actively informing the fi nal design of the EXCLAIM instrument. EXCLAIM will incorporate six spectrometers, each containing an array of over 300 resonators in the 420-540 GHz range.

Carrie Volpert↗

Overview and Status of EXCLAIM, the Experiment for Cryogenic Large-Aperture Intensity Mapping

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne far-infrared telescope that will survey star formation history over cosmological time scales to improve our un-derstanding of why the star formation rate declined at redshiftz <2, despite continued clustering of darkmatter. Specifically, EXCLAIM will map the emission of redshifted carbon monoxide and singly ionized carbon lines in windows over a redshift range0< z <3.5, following an innovative approach known asintensity mapping. Intensity mapping measures the statistics of brightness fluctuations of cumulative lineemissions, as opposed to detecting individual galaxies, thus enabling a blind, complete census of the emittinggas. To detect this emission unambiguously, EXCLAIM will cross-correlate with a rich spectroscopic galaxycatalog. The EXCLAIM mission will use a cryogenic design to cool the telescope optics to approximately1.7K. The telescope will feature a90-cm primary mirror to probe spatial scales on the sky from the linearregime up to shot-noise-dominated scales. The telescope optical elements will couple to six μ-Spec spectrom-eter modules, operating over a420–540-GHz frequency band with a spectral resolution of512and featuringMicrowave Kinetic Inductance Detectors (MKIDs). In the baseline design, the detectors will be read out witha Radio Frequency System-on-Chip (RFSoC). The cryogenic telescope and the sensitive detectors will allowEXCLAIM to reach high sensitivity in spectral windows of low emission in the upper atmosphere. Here, anoverview of the mission design and development status since the start of the EXCLAIM project in early 2019 is presented.

Giuseppe Cataldo↗

Second-generation Micro-Spec: Spectrometer Design for the Experiment for Cryogenic Large-Aperture Intensity Mapping

Micro-Spec (μ-Spec) is a direct-detection spectrometer that integrates all the components of a diffraction-grating spectrometer onto a ∼10-cm2 chip using superconducting microstrip transmission lines on a single-crystal silicon substrate. The second-generation μ-Spec has been designed to operate with a spectral resolution of ∼512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA’s EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). EXCLAIM will be a high-altitude balloon mission that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5. EXCLAIM will be the first demonstration of the μ-Spec technology in a space-like environment. This work reviews the status of the μ-Spec design for the EXCLAIM instrument, with emphasis on the spectrometer’s two-dimensional diffractive region, through which light of different wavelengths is focused on microwave kinetic inductance detectors (MKIDs) along the spectrometer focal plane. An optimization process generates a geometrical configuration of the diffractive region that satisfies specific requirements on size, operating spectral range and performance. An initial optical design optimized for EXCLAIM is presented in terms of geometric layout, spectral purity and efficiency.

Giuseppe Cataldo↗

Simulating the Phonon Collection Efficiency in KIPMDs

Kinetic inductance phonon-mediated (KIPM) detectors use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the substrate. They are a promising class of detectors to be used in light dark matter (DM) searches due to their potential eV-scale sensitivity and native frequency-domain multiplexability. In order to improve upon the design of these detectors, simulations are needed to understand the effects of detector design on measurable physical parameters including the phonon collection efficiency, $\eta_{ph}$, which is defined as the ratio of phonon energy detected by the sensitive target element to the incident energy deposited in the substrate. This work simulates the phonon collection efficiency for a KIPMD currently operated at the Northwestern EXperimental Underground Site (NEXUS).

Dang, Stella Q.↗

Simulating the Phonon Collection Efficiency in Kinetic Inductance Phonon-Mediated Detectors

Kinetic inductance phonon-mediated (KIPM) detectors use microwave kinetic inductance detectors (MKIDs) to read out phonon signals in the substrate. They are a promising class of detectors to be used in light dark matter (DM) searches due to their potential eV-scale sensitivity and native frequency-domain multiplexability. In order to improve upon the design of these detectors, simulations are needed to understand the effects of detector design on measurable physical parameters including the phonon collection efficiency, $\eta_{ph}$, which is defined as the ratio of phonon energy detected by the sensitive target element to the incident energy deposited in the substrate. This work simulates the phonon collection efficiency for two existing detector architectures to study phonon absorption at substrate-sensor interfaces and phonon loss to non-sensitive detector elements.

Dang, Stella Q.↗