Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MINIATURIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Low Activation Joining of SiC/SiC Composites for Fusion Applications: Miniature Torsion Specimen Shear Testing

The use of SiC composites in fusion environments likely requires joining of plates using reactive joining or brazing. One promising reactive joining method uses solid-state displacement reactions between Si and TiC to produce Ti3SiC2 + SiC. We continue to explore the processing envelope for this joint for the TITAN collaboration in order to produce optimal joints to undergo irradiation studies in HFIR. The TITAN collaboration has designed miniature torsion joints for preparation, testing, and irradiation in HFIR. PNNL synthesized 40 miniature torsion joints and several were tested for shear strength prior to irradiation testing in HFIR. The resulting tests indicated that (1) joint fixture alignment problems cause joint strengths to be lower than optimal, (2) that non-planar torsion test failures limit the effectiveness of the miniature specimen design, and (3) that several joints that were well aligned had high shear strengths and promising mechanical properties. In summary, we now show conclusively that high joint strengths cause non-planar shear fracture and complicate strength analysis for miniature torsion specimens.

36 MATERIALS SCIENCE↗

Development of a Semi-autonomous Miniature Rover for Inspection of Double Shell Tank Floors - 19575

Leaks in the primary liner of double-shell tank (DST) 241-AY-102 at Hanford have prompted the need for the development of inspection tools that are able to access confined spaces around and underneath the tanks. Last year, Florida International University (FIU) has continued to improve inspection tools that were developed in the previous years, to ensure that the resultant tools are able to overcome the challenges posed by the DSTs. Experimental testing conducted last year at the full-scale sectional mock-up of the DST's refractory slots revealed some shortcomings of the miniature rover, particularly in traversing over weld seams of different heights. The weld seams are the results of welded steel plate-joints for the DST. It was advised by the site engineers that the weld seams height could range from 6.35 mm - 9.525 mm (1/4 to 3/8 inches), and with 12.7 mm (1/2 inches) width. As the rover traverses over a weld seam, the gap between the rover's magnets and tank surface increases, causing the adhesive force to drop. The rover loses its surface contact if this adhesive force drops below its weight, jeopardizing the inspection tasks. In this paper, we present the numerical studies to calculate the minimum magnetic force required for the miniature rover to traverse over weld seams with different heights and the corresponding modifications to the rover design. Initial bench scale tests were conducted using a steel bar with 5 welds of varying heights. The testing validated the results from the simulation studies and established the rover's capability in traversing weld seams. Another challenge for the miniature rover is the use of a joystick or keypad for manual control. Utilizing these controls will likely be difficult for the operators due to the tight channels underneath the tank. Having a semi-autonomous navigational capability would alleviate the complexity of the inspection tasks and allow the operator to focus on the channel inspection. The goal is to implement lane-keeping capability, akin to that of a driverless car, for the inspection tool, so that it will maintain its relative position with respect to the wall of the channels. Am image processing pipeline has been developed using both the Robot Operating System (ROS) and OpenCV to process the image stream coming from the onboard camera, for the purpose of lane identification. Additionally, a PID controller has been implemented to navigate the miniature rover along the central location of the detected lane, while allowing the operator to control the tool's forward and backward motion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of miniature test specimens for post-irradiation thermal diffusivity measurement

Radioactivity levels for conventional thermal diffusivity test specimens are often prohibitively high for examination with candidate metallic materials, such as tungsten and reduced activation steels for fusion energy. Therefore, in the ongoing Japan–US PHENIX project, irradiation in the high flux isotope reactor (HFIR) was performed with the miniature specimen form of diameter (D) 3 mm × thickness (T) 1/2 mm small disk for thermal diffusivity measurement. In this study, the thermal diffusivity measurement of this miniature specimen is validated using a Netzsch LFA-467 ‘Hyper Flash’ thermal analyzer and ‘graphene nanoplatelets containing agent’. Finally, with careful surface treatment and data analysis, the miniature specimens showed almost the same value as the diameter 10 mm standard specimens.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A miniature electron ionization source fabricated using microelectromechanical systems ($\mathrm{MEMS}$) with integrated carbon nanotube ($\mathrm{CNT}$) field emission cathodes and low-temperature co-fired ceramics ($\mathrm{LTCC}$)

The use of microelectromechanical systems (MEMS) components in miniature mass spectrometers is particularly attractive due to their small size and scalable manufacturing capability. Our group has pioneered the development of miniature electron ionization sources combining MEMS fabricated structures with integrated carbon nanotube (CNT) cold-cathode field emitters. However, until now they have been of limited use due to the limited ability to direct the ions into a mass analyzer. In this work, we design a miniature ion source using a microfabricated MEMS device and a low temperature co-fired ceramic (LTCC) carrier that includes electrical connections, ion optics for directing ions out of the device, and a sample inlet. Here we present the design and fabrication of the ion source; simulate the energy and angular dispersion; and experimentally determine the energy and angular dispersion.

47 OTHER INSTRUMENTATION↗

Flight experience with lightweight, low-power miniaturized instrumentation systems

Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. The purpose of this article is to report NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs. This article will describe the data loggers, the sensors, and the hardware and software developed to complete the systems. It also describes how the systems were used and covers the challenges encountered to make them work. Examples of raw data and derived results will be shown as well. For some flight research applications where miniaturized instrumentation is a requirement, the authors conclude that commercially available data loggers and sensors are viable alternatives. In fact, the data loggers and sensors make it possible to gather research-quality data in a timely and cost-effective manner.

LOW POWER MINIATURIZED INSTRUM↗

Development of thermoelectric fibers for miniature thermoelectric devices

Miniature thermoelectric (TE) devices may be used in a variety of applications such as power sources of small sensors, temperature regulation of precision electronics, etc. Reducing the size of TE elements may also enable design of novel devices with unique form factor and higher device efficiency. Current industrial practice of fabricating TE devices usually involves mechanical removal processes that not only lead to material loss but also limit the geometry of the TE elements. In this project, we explored a powder-processing method for the fabrication of TE fibers with large length-to-area ratio, which could be potentially used for miniature TE devices. Powders were milled from Bi2Te3-based bulk materials and then mixed with a thermoplastic resin dissolved in an organic solvent. Through an extrusion process, flexible, continuous fibers with sub-millimeter diameters were formed. The polymer phase was then removed by sintering. Sintered fibers exhibited similar Seebeck coefficients to the bulk materials. Moreover, their electrical resistivity was much higher, which might be related to the residual porosity and grain boundary contamination. Prototype miniature uni-couples fabricated from these fibers showed a linear I-V behavior and could generate millivolt voltages and output power in the nano-watt range. Further development of these TE fibers requires improvement in their electrical conductivities, which needs a better understanding of the causes that lead to the low conductivity in the sintered fibers.

36 MATERIALS SCIENCE↗

A progressive electrochemical sensor for food quality control: Reliable determination of theobromine in chocolate products using a miniaturized boron-doped diamond electrode

In the present paper, a miniaturized boron-doped diamond electrode (BDDE) is proposed as a progressive electrochemical sensor for simple, fast and reliable quantification of dimethylxanthine alkaloid, theobromine (TB). Using cyclic voltammetry, the studied xanthine provided one well-shaped, irreversible and diffusion-controlled oxidation peak at relatively high potentials (+1.2 V vs. Ag/AgCl/3 M KCl reference electrode) in the presence of 0.1 M H2SO4. After selection of suitable experimental conditions, the linear calibration curves for TB were obtained in the concentration range from 0.99 up to 54.5 μM with the sensitivity of 0.07 μA/μM providing both differential pulse (DPV) and square-wave voltammetric (SWV) techniques, respectively. The elaborated voltammetric protocol yielded low detection limits of 0.42 and 0.51 μM accompanied by adequate intra-day repeatability (relative standard deviation of 2.5 and 1.7%) using DPV and SWV procedure, respectively. The interference study revealed the reasonable selectivity when taking the target food samples into account. The practical applicability of the voltammetric protocol using a miniaturized BDDE was verified in the analysis of six commercially available brands of chocolate products with the determined mass percentages of TB ranging from 0.75 to 2.24% and from 0.69 to 2.15% using DPV and SWV procedure, respectively. The obtained results were also in a good agreement with those achieved by reference titration method with potentiometric indication. The progressive electrochemical sensor based on a miniaturized BDDE has appeared to be an attractive candidate for practical applications in food quality control. Besides, the proposed voltammetric protocol presents advantages when compared to others techniques (e.g. chromatography), concerning simplicity, cost, speed of analysis, waste generation (environmentally friendly) and samples pretreatment (only dilution in electrolyte solution prior to analysis). © 2018 Elsevier B.V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of miniaturized, spectroscopically assisted Penning gauges for fractional helium and hydrogen neutral pressure measurements

Direct measurements of the helium (He) fractional neutral pressure in the neutral gas around fusion devices is challenging because of the small mass difference between the abundant D2 molecules and the He atoms which will be produced by D-T fusion. To study He exhaust, Penning gauges were used to measure total neutral pressure assisted by spectroscopy to resolve the D and He partial pressures. In this contribution, initial results are shown from developing this technique into a miniaturized configuration for direct in-situ measurements in the divertor of fusion devices. The configuration is based off a gauge originally designed for the National Spherical Tokamak Experiment-Upgrade (NSTX-U). The goal of this new miniaturized design it to reduce the space required by the gauge on the device and use of the inherent magnetic field of the machine rather than permanent magnets inside the gauge, enabling it to be adapted into a system that can be extended directly into the divertor region. The feasibility test of the method for NSTX-U and the Wendelstein 7-X (W7-X) stellarator are surveyed. For W7-X, a commercial Penning Gauge has been installed on an outboard vacuum flange as a generic feasibility test in the neutral gas environment of a stellarator. At an integration time of 25s, helium lines can be seen down to 10^-5 mbar and H-alpha lines down to 10^-6 mbar. Successful measurement of the total as well as the fractional neutral pressures of He and H has been shown. A first prototype of the miniature Penning gauge has been tested in Madison and shows a near linear power law scaling between current and pressure: I = C*P^n with n = 1.0 - 1.2. Pressure measurements were achieved starting at 10^-3 mbar and down to 10^-6 mbar. A modular gauge is being assembled, which allows easy interchangeability of the anode to test new anode geometries, in order to improve optical access and increase spectroscopic sensitivity. This shall enable an increase of the time resolution of the spectroscopically assisted fractional neutral pressure measurements to up to 1kHz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Highly Miniaturized Cloud and Aerosol Instrument Package for Small UAS's

Unmanned Aerial Systems (UAS’s), which include Unmanned Aerial Vehicles (UAV’s) and tethered balloon systems (TBS) offer significant advantages over conventional research aircraft. They are capable of long-duration measurements of cloud properties in regions where piloted aircraft are unsafe, e.g., at very low altitudes over remote regions, such as tundra and open ocean. TBS and UAV’s are now widely recognized as a technology that can provide unprecedented insights into cloud and radiation processes, but development of miniature sensors capable of providing sophisticated measurements of cloud, aerosol and radiative properties lag behind. In Phase II of this SBIR research, Stratton Park Engineering Company, Inc. (SPEC) designed and fabricated a miniature combination optical particle probe (micro-COPP) that is capable of being flown on small UAV’s and TBS. The micro-COPP measures the size distribution of cloud particles from 2 microns to several millimeters and records high-definition images that distinguish ice particle from water drops, which is essential in mixed-phase clouds. The micro-COPP was installed along with miniature instruments to measure aerosols, cloud condensation nuclei, position and atmospheric state parameters on a small UAV and TBS that were deployed in the Arctic at the Ny-Ålesund, Svalbard (78° N. latitude).

54 ENVIRONMENTAL SCIENCES↗

Miniature Beryllium Split-Hopkinson Pressure Bars for Extending the Range of Achievable Strain-Rates

Conventional Split Hopkinson Pressure Bars (SHPB) or “Kolsky” bars are often used for determining the high-rate compressive yield and failure strength of materials. However, for experiments generating very high strain-rates (>10 3 /s) miniaturization of the setup is often required for minimizing the effects of elastic wave dispersion in order to enable the inference of decreasingly short loading events from the data. Miniature aluminum and steel bars are often sufficient for meeting these requirements. However, for high enough strain-rates, miniaturization of steel or aluminum Kolsky bars may require prohibitively small diameter bars and test specimens that could become inappropriate for inferring representative properties of materials with large grain size relative to the test specimen size. The use of a beryllium Kolsky bar setup is expected to enable high rates to be accessible with larger diameter bars/specimen combinations due to the inherent physical properties of beryllium, which are expected to minimize the effects of elastic wave dispersion. For this reason, a series of beryllium Kolsky bars have been developed, and, in this paper, the dispersion characteristics of these bars are measured and compare the data with those of similarly sized 7075-T6 aluminum and C350 maraging steel. The results, which agree well with the theory, show no appreciable frequency dependence of the elastic wavespeed in the data from the beryllium bars, demonstrating its advantage over aluminum and steel in application to Kolsky bars.

36 MATERIALS SCIENCE↗

Miniaturized pointing mount performance analysis

Analytical analysis and computer simulation results of the miniaturized pointing mount as an instrument pointing system are presented. Miniaturized mount performance results include inertial pointing, slewing, tracking, and rastering. Typical instrument characteristics are used as well as some parameter variations of instrument and miniaturized pointing mount characteristics.

Howell, G. T., Jr.↗

Miniaturized Cassegrainian concentrator concept demonstration

High concentration ratio photovoltaic systems for space applications have generally been considered impractical because of perceived difficulties in controlling solar cell temperatures to reasonably low values. A miniaturized concentrator system is now under development which surmounts this objection by providing acceptable solar cell temperatures using purely passive cell cooling methods. An array of identical miniaturized, rigid Cassegrainian optical systems having a low f-number with resulting short dimensions along their optical axes are rigidly mounted into a frame to form a relatively thin concentrator solar array panel. A number of such panels, approximately 1.5 centimeters thick, are wired as an array and are folded against one another for launch in a stowed configuration. Deployment on orbit is similar to the deployment of conventional planar honeycomb panel arrays or flexible blanket arrays. The miniaturized concept was conceived and studied in the 1978-80 time frame. Progress in the feasibility demonstration to date is reported.

Patterson, R. E.↗

Miniature metastable ionization detectors for exobiology flight experiments

The Metastable Ionization Detector (MID) is three orders of magnitude more sensitive than the thermal conductivity detectors used on previous flight instruments. The miniature MID provides scientists with a much smaller and highly sensitive detector for flight gas chromatographs. A miniature MID featuring an unconventional triaxial electrode configuration was developed and used routinely in the laboratory. Although much smaller and lighter than the commercial MID, its performance characteristics parallel those of the traditional design. The detector is compatible with the modulated voltage circuitry, also developed here, and thus can perform over an expanded response range of more than 7 orders magnitude. A micro volume version of a miniature MID, with an internal volume of less than 8 microliter, was recently designed is now being tested. The micro volume MID uses carrier gas flow rates of approx. 2cc/min thus eliminating the need for makeup gas when capillary columns are used.

Woeller, F. H.↗

Miniaturization of flight deflection measurement system

A flight deflection measurement system is disclosed including a hybrid microchip of a receiver/decoder. The hybrid microchip decoder is mounted piggy back on the miniaturized receiver and forms an integral unit therewith. The flight deflection measurement system employing the miniaturized receiver/decoder can be used in a wind tunnel. In particular, the miniaturized receiver/decoder can be employed in a spin measurement system due to its small size and can retain already established control surface actuation functions.

Fodale, Robert↗

Comprehensive helicopter rotor instrumentation - A retrofit approach using miniature transducers

This paper reports an approach used to retrofit a set of full-scale main rotor blades with 290 miniature pressure transducers, 46 strain gages, and 24 miniature accelerometers. Normally, in order to avoid disturbing the aerodynamics of the rotor flow field, the pressure instrumentation must be integrally built into the body of the rotor blades. However, using a method developed with NASA, miniature pressure transducers are mounted to the blade exterior surface without degrading the quality of the blade aerodynamics. Moreover, it is estimated that this approach reduced costs by more than 50 percent over building a set of pressure instrumented blades. The aerodynamic measurement objectives are presented as are instrumentation design considerations, type of instrumentation used, assembly process, and the installed instrumentation characteristics.

Jacklin, Stephen A.↗

Flight experience with lightweight, low-power miniaturized instrumentation systems

Engineers at the NASA Dryden Flight Research Facility (NASA-Dryden) have conducted two flight research programs with lightweight, low-power miniaturized instrumentation systems built around commercial data loggers. One program quantified the performance of a radio-controlled model airplane. The other program was a laminar boundary-layer transition experiment on a manned sailplane. NASA-Dryden personnel's flight experience with the miniaturized instrumentation systems used on these two programs is reported. The data loggers, the sensors, and the hardware and software developed to complete the systems are described. How the systems were used is described and the challenges encountered to make them work are covered. Examples of raw data and derived results are shown as well. Finally, future plans for these systems are discussed. For some flight research applications where miniaturized instrumentation is a requirement, the authors conclude that commercially available data loggers and sensors are viable alternatives. In fact, the data loggers and sensors make it possible to gather research-quality data in a timely and cost-effective manner.

Hamory, Philip J.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

Miniature Long-life Space Cryocoolers

TRW has designed, built, and tested a miniature integral Stirling cooler and a miniature pulse tube cooler intended for long-life space application. Both efficient, low-vibration coolers were developed for cooling IR sensors to temperatures as low as 50 K on lightsats. The vibrationally balanced nonwearing design Stirling cooler incorporates clearance seals maintained by flexure springs for both the compressor and the drive displacer. The design achieved its performance goal of 0.25 W at 65 K for an input power to the compressor of 12 W. The cooler recently passed launch vibration tests prior to its entry into an extended life test and its first scheduled flight in 1995. The vibrationally balanced, miniature pulse tube cooler intended for a 10-year long-life space application incorporates a flexure bearing compressor vibrationally balanced by a motor-controlled balancer and a completely passive pulse tube cold head.

Tward, E.↗