Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROCOMPUTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

MicroComputed Tomography: Methodology and Applications

Due to the availability of commercial laboratory systems and the emergence of user facilities at synchrotron radiation sources, studies of microcomputed tomography or microCT have increased exponentially. MicroComputed Technology provides a complete introduction to the technology, describing how to use it effectively and understand its results. The first part of the book focuses on methodology, covering experimental methods, data analysis, and visualization approaches. The second part addresses various microCT applications, including porous solids, microstructural evolution, soft tissue studies, multimode studies, and indirect analyses. The author presents a sufficient amount of fundamental material so that those new to the field can develop a relative understanding of how to design their own microCT studies. One of the first full-length references dedicated to microCT, this book provides an accessible introduction to field, supplemented with application examples and color images.

43 PARTICLE ACCELERATORS↗

Microcomputed X-Ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

Microstructural characterization of composite high explosives (HEs) has become increasingly important over the last several decades in association with the development of high fidelity mesoscale modeling and an improved understanding of ignition and detonation processes. HE microstructure influences not only typical material properties (e.g., thermal, mechanical) but also reactive behavior (e.g., shock sensitivity, detonation wave shape). A detailed nondestructive 3D examination of the microstructure has generally been limited to custom-engineered samples or surrogates due to poor contrast between the composite constituents. Highly loaded (>90 wt%) HE composites such as plastic-bonded explosives (PBX) are especially difficult. Here, we present efforts to improve measurement quality by using single and dual-energy microcomputed X-ray tomography and state-of-the-art image processing techniques to study a broad set of HE materials. Some materials, such as PBX 9502, exhibit suitable contrast and resolution for an automatic segmentation of the HE from the polymer binder and the voids. Other composite HEs had varying levels of success in segmentation. Post-processing techniques that used commercially available algorithms to improve the segmentation quality of PBX 9501 as well as zero-density defects such as cracks and voids could be easily segmented for all samples. Aspects of the materials that lend themselves well to this type of measurement are discussed.

36 MATERIALS SCIENCE↗

Psychology of computer use: IX. A menu of self-administered microcomputer-based neurotoxicology tests

This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests which may have application in screening for fitness-for-duty or for persons who may be exposed to environmental stress, toxic agents, or disease. 16 subjects self-administered 18 microcomputer-based tests (13 new, 5 "core"), without proctors, over 10 sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the tests from the "core" battery were comparable to those obtained previously under more controlled experimental conditions. Eight of the new tests exceeded minimum criteria for metric and practical requirements and can be recommended as additions to the menu. Although the average retest reliability was high, cross-correlations between tests were low, implying factorial diversity. The menu can be used to form batteries with flexible total testing time which are likely to tap different mental processes and functions.

NASA Discipline Neuroscience↗

Monitoring reinforcement corrosion and corrosion-induced cracking by X-ray microcomputed tomography method

X-ray microcomputed tomography (X-ray μCT) method is proposed to trace steel corrosion and corrosion-induced cracking in cement paste. Experimental results show it can track the time-dependent development of steel corrosion and corrosion products, as well as the subsequent initiation and propagation of corrosion-induced cracks. Furthermore, the information of corrosion pits, corrosion products, and corrosion-induced cracks can be clearly obtained from the whole specimen by this novel method. Additionally, SEM/EDS results agree closely with image analyses by X-ray μCT. This method provides a new angle to investigate the reinforcement corrosion process and can help to improve the numerical analysis of corrosion-induced damage in reinforced concrete structures. - Highlights: • Reinforcement corrosion and corrosion-induced cracking is traced by X-ray μCT method. • The development of corrosion products can be determined as a function of time and space. • Subsequent initiation and propagation of corrosion-induced cracks can be monitored. • The time-dependent corrosion process can be quantitative analyzed by X-ray μCT measurement.

36 MATERIALS SCIENCE↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

A microcomputed tomography guided fluorescence tomography system for small animal molecular imaging

A prototype small animal imaging system was created for coupling fluorescence tomography (FT) with x-ray microcomputed tomography (microCT). The FT system has the potential to provide synergistic information content resultant from using microCT images as prior spatial information and then allows overlay of the FT image onto the original microCT image. The FT system was designed to use single photon counting to provide maximal sensitivity measurements in a noncontact geometry. Five parallel detector locations are used, each allowing simultaneous sampling of the fluorescence and transmitted excitation signals through the tissue. The calibration and linearity range performance of the system are outlined in a series of basic performance tests and phantom studies. The ability to image protoporphyrin IX in mouse phantoms was assessed and the system is ready for in vivo use to study biological production of this endogenous marker of tumors. This multimodality imaging system will have a wide range of applications in preclinical cancer research ranging from studies of the tumor microenvironment and treatment efficacy for emerging cancer therapeutics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of X-ray microcomputed tomography in the characterization of irradiated nuclear fuel and material specimens

X-ray microcomputed tomography (µCT) was applied in characterizing the internal structures of a number of irradiated materials, including carbon-carbon fibre composites, nuclear-grade graphite and tristructural isotropic-coated fuel particles. Local cracks in carbon-carbon fibre composites associated with their synthesis process were observed with µCT without any destructive sample preparation. Pore analysis of graphite samples was performed quantitatively, and qualitative analysis of pore distribution was accomplished. It was also shown that high-resolution µCT can be used to probe internal layer defects of tristructural isotropic-coated fuel particles to elucidate the resulting high release of radioisotopes. Layer defects of sizes ranging from 1 to 5 µm and up could be isolated by to-mography. As an added advantage, µCT could also be used to identify regions with high densities of radioisotopes to deter-mine the proper plane and orientation of particle mounting for further analytical characterization, such as materialographic sectioning followed by optical and electron microscopy. Lastly, in fully ceramic matrix fuel forms, despite the highly absorbing matrix, characterization of tristructural isotropic-coated particles embedded in a silicon carbide matrix was accomplished usingµCT and related advanced image analysis techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration and evaluation of a needle-positioning robot with volumetric microcomputed tomography image guidance for small animal stereotactic interventions

Purpose: Preclinical research protocols often require insertion of needles to specific targets within small animal brains. To target biologically relevant locations in rodent brains more effectively, a robotic device has been developed that is capable of positioning a needle along oblique trajectories through a single burr hole in the skull under volumetric microcomputed tomography (micro-CT) guidance. Methods: An x-ray compatible stereotactic frame secures the head throughout the procedure using a bite bar, nose clamp, and ear bars. CT-to-robot registration enables structures identified in the image to be mapped to physical coordinates in the brain. Registration is accomplished by injecting a barium sulfate contrast agent as the robot withdraws the needle from predefined points in a phantom. Registration accuracy is affected by the robot-positioning error and is assessed by measuring the surface registration error for the fiducial and target needle tracks (FRE and TRE). This system was demonstrated in situ by injecting 200 {mu}m tungsten beads into rat brains along oblique trajectories through a single burr hole on the top of the skull under micro-CT image guidance. Postintervention micro-CT images of each skull were registered with preintervention high-field magnetic resonance images of the brain to infer the anatomical locations of the beads. Results: Registration using four fiducial needle tracks and one target track produced a FRE and a TRE of 96 and 210 {mu}m, respectively. Evaluation with tissue-mimicking gelatin phantoms showed that locations could be targeted with a mean error of 154{+-}113 {mu}m. Conclusions: The integration of a robotic needle-positioning device with volumetric micro-CT image guidance should increase the accuracy and reduce the invasiveness of stereotactic needle interventions in small animals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved accuracy of cortical bone mineralization measured by polychromatic microcomputed tomography using a novel high mineral density composite calibration phantom

Purpose: Microcomputed tomography (micro-CT) is increasingly used as a nondestructive alternative to ashing for measuring bone mineral content. Phantoms are utilized to calibrate the measured x-ray attenuation to discrete levels of mineral density, typically including levels up to 1000 mg HA/cm{sup 3}, which encompasses levels of bone mineral density (BMD) observed in trabecular bone. However, levels of BMD observed in cortical bone and levels of tissue mineral density (TMD) in both cortical and trabecular bone typically exceed 1000 mg HA/cm{sup 3}, requiring extrapolation of the calibration regression, which may result in error. Therefore, the objectives of this study were to investigate (1) the relationship between x-ray attenuation and an expanded range of hydroxyapatite (HA) density in a less attenuating polymer matrix and (2) the effects of the calibration on the accuracy of subsequent measurements of mineralization in human cortical bone specimens. Methods: A novel HA-polymer composite phantom was prepared comprising a less attenuating polymer phase (polyethylene) and an expanded range of HA density (0-1860 mg HA/cm{sup 3}) inclusive of characteristic levels of BMD in cortical bone or TMD in cortical and trabecular bone. The BMD and TMD of cortical bone specimens measured using the new HA-polymer calibration phantom were compared to measurements using a conventional HA-polymer phantom comprising 0-800 mg HA/cm{sup 3} and the corresponding ash density measurements on the same specimens. Results: The HA-polymer composite phantom exhibited a nonlinear relationship between x-ray attenuation and HA density, rather than the linear relationship typically employed a priori, and obviated the need for extrapolation, when calibrating the measured x-ray attenuation to high levels of mineral density. The BMD and TMD of cortical bone specimens measured using the conventional phantom was significantly lower than the measured ash density by 19% (p<0.001, ANCOVA) and 33% (p<0.05, Tukey's HSD), on average, respectively. The BMD and TMD of cortical bone specimens measured using the HA-polymer phantom with an expanded range of HA density was significantly lower than the measured ash density by 8% (p<0.001, ANCOVA) and 10% (p<0.05, Tukey's HSD), on average, respectively. Conclusions: The new HA-polymer calibration phantom with a less attenuating polymer and an expanded range of HA density resulted in a more accurate measurement of micro-CT equivalent BMD and TMD in human cortical bone specimens compared to a conventional phantom, as verified by ash density measurements on the same specimens.

07 ISOTOPE AND RADIATION SOURCES↗

A generic, geometric cocalibration method for a combined system of fluorescence molecular tomography and microcomputed tomography with arbitrarily shaped objects

Purpose: A combined system of fluorescence molecular tomography and microcomputed tomography (FMT and mCT) can provide molecular and anatomical information of small animals in a single study with intrinsically coregistered images. The anatomical information provided by the mCT subsystem is commonly used as a reference to locate the fluorophore distribution or as a priori structural information to improve the performance of FMT. Therefore, the transformation between the coordinate systems of the subsystem needs to be determined in advanced. Methods: A cocalibration method for the combined system of FMT and mCT is proposed. First, linear models are adopted to describe the galvano mirrors and the charge-coupled device (CCD) camera in the FMT subsystem. Second, the position and orientation of the galvano mirrors are determined with the input voltages of the galvano mirrors and the markers, whose positions are predetermined. The position, orientation and normalized pixel size of the CCD camera are obtained by analysing the projections of a point-like marker at different positions. Finally, the orientation and position of sources and the corresponding relationship between the detectors and their projections on the image plane are predicted. Because the positions of the markers are acquired with mCT, the registration of the FMT and mCT could be realized by direct image fusion. Results: The accuracy and consistency of this method in the presence of noise is evaluated by computer simulation. Next, a practical implementation for an experimental FMT and mCT system is carried out and validated. The maximum prediction error of the source positions on the surface of a cylindrical phantom is within 0.375 mm and that of the projections of a point-like marker is within 0.629 pixel. Finally, imaging experiments of the fluorophore distribution in a cylindrical phantom and a phantom with a complex shape demonstrate the feasibility of the proposed method. Conclusions: This method is universal in FMT and mCT, which could be performed with no restriction on the system geometry, calibration phantoms or imaging objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Supplementary material for manuscript: Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives

This data contains the supplemental information that will be accessible to the public from the paper “Microcomputed X-ray Tomographic Imaging and Image Processing for Microstructural Characterization of Explosives”. The data set contains the reconstructed slices for the 3D images of three different high explosives including: HMX-HTPB, PBX 9501 and PBX 9502. The data sets are folders of reconstructed tiffs showing the microstructure (crystals, binder, voids) and a segmented data set of each. Finally, a .gif movie is also present that plays the slices sequentially. The folders contain the voxel size information. See the manuscript for more details.

36 MATERIALS SCIENCE↗

A proposed microcomputer implementation of an Omega navigation processor

A microprocessor navigation systems using the Omega process is discussed. Several methods for correcting incoming sky waves are presented along with the hardware design which depends on a microcomputer. The control program is discussed, and block diagrams of the Omega processor and interface systems are presented.

Abel, J. D.↗

A microcomputer-based low-cost Omega navigation system

The application of a low cost, commercially available microcomputer as the navigation processor for a simplified OMEGA navigation system is an area of current research. The interface of a low cost front end OMEGA sensor is described and an example of the phase processing software and navigation routines is given. Emphasis is placed on the description of results obtained with the software version of the OMEGA burst filter known as the memory aided phase locked loop.

Lilley, R. W.↗

Demonstration program for Omega receiver prototype microcomputer data processing

The JOLT (TM) commercial microcomputer, based on the MOS Technology 6502 processor chip, for use in Omega navigation system is evaluated. A computer program was prepared in hand-assembled code to demonstrate receiver operation. The processor provides binary processing with interrupts enabled, a carriage return is given to initialize the teleprinter, and a jump is performed to enter the program loop to wait for an interrupt. The program loop operates continuously testing the interrupt flag. The interrupt routine reads the receiver status word and determines whether the current time-slot is the A slot. If so, the interrupt flag, which is also the data index pointer, is reset to zero. The status word is stored in the status buffer. If the time-slot is not A, the interrupt flag/pointer is incremented by one to index the phase and status to the proper buffer words for later use by the print routine.

Lilley, R. W.↗

A microcomputer-based low-cost Omega sensor processor

The engineering approach used in the design of a low cost Omega sensor processor is discussed. The processor and its operations are described, as well as the system hardware and software. Circuit details of the hardware modules and program listings for the FORTRAN and microcomputer software are included.

Salter, R. J., Jr.↗

A programmable microcomputer for real time speech processing

The implementation of a programmable microprocessor for real time speech processing is described. The design of a fast special-purpose computer operating at 150 nsec per instruction time reduces the problem of speech encoding and decoding to a software problem. Each instruction is a twelve-bit word, and the information conveyed by a word is explained. The microprocessor is controlled by two clocks - the A/D clock, or input sampling clock, which loads the digital input into the input register and presets the counter to a value set by the external switches; and the instruction clock, or system clock, which operates at 6 MHz. At this system clock rate and a sampling clock rate of 30 KHz, 200 instructions can be executed between samples, and for many speech encoding and decoding algorithms, 200 instructions are more than enough. The microcomputer is being used to test various delta modulator encoding algorithms.

Apelewicz, T.↗

Microcomputer helps evaluate skin burns

Microcomputer analysis of multispectral imaging of burn area aids production of display map of field and partial thickness burns making more effective clinical treatment possible.

Anselmo, V. J.↗

The current status of microcomputer arrays

Some research projects on microcomputer arrays are at the stage of constructing hardware, while others are at the design and planning stages. A general overview of the topic is followed by a more detailed discussion of three projects whose purposes are specifically scientific computation.

Knight, J. C.↗