Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MEV RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Lower hybrid resonance acceleration of electrons and ions in solar flares and the associated microwave emission

The particle acceleration processes here studied are driven by the relaxation of unstable ion ring distributions; these produce strong wave activity at the lower hybrid resonance frequency which collapses, and forms energetic electron and ion tails. The results obtained are applied to the problem posed by the production of energetic particles by solar flares. The numerical simulation results thus obtained by a 2 1/2-dimensional particle-in-cell code show a simultaneous acceleration of electrons to 10-500 keV energies, and of ions to as much as the 1 MeV range; the energy of the latter is still insufficient to account for gamma-ray emission in the 4-6 MeV range, but furnish a seed population for further acceleration.

Mcclements, K. G.↗

OSSE observations of the Crab pulsar

We present results of the Compton Gamma-Ray Observatory (CGRO) Oriented Scintillation Spectrometer Experiment (OSSE) observations of the Crab pulsar, made during MJD 48373-48406 (1991 April 27 - 1991 May 30) and MJD 48798-48804 (1992 June 25 - 1992 July 1). Pulsar light curves and spectra over the approximately 0.05 to 10 MeV range are presented. The arrival time of the gamma-ray peak and the radio peak agree to within 30 microsec which is better than the approximately 300 microsec accuracy of the measurements. The overall pulse phase averaged spectrum in the 0.1 - 10 MeV range is well-fit by a power law of the form 0.05 x (E/0.13 MeV)exp(-(1.99 +/- 0.03)) photons/sq cm/s. The outer-gap model (with gap parameter equal to 0.46) provided to us by Ho agrees with the data to better than 20%. The spectra of the bridge and second peak are slightly harder than the first peak as measured by the hardness ratio (approximately 110 - 220 keV)/(approximately 50 - 105 keV): P1 = 0.54 +/- 0.01, P2 = 0.63 +/- 0.01, bridge = 0.68 +/- 0.03. The phase of the two peaks in the light curve is constant over the 50 - 550 keV range to within the accuracy of the measurements (better than 0.02 in phase). No evidence was found for variability of the light curve on timescales from 2 minutes (less than a factor of 1.8) to 1 year (less than a factor of 1.06), where these are 3 sigma upper limits. However, when we examine the historical database, we find, in agreement with Nolan et al. (1993), that there is evidence for a 13 year variation in the ratio of the intensity of peak 2 to peak 1. We show that if this is interpreted as being due to precession (which changes the relative view of the intrinsic gamma-ray pulse as seen on earth), the variation is consistent with models of neutron star structure. The optical data may be in conflict with the interpretation however. We found no statistically significant lines in the 50 - 550 keV range in the spectrum. The average 3 sigma upper limits in 10(exp -3) photons/sq cm/s for lines at 0.073, 0.078, 0.4, 0.44, 0.511, and 0.545 MeV are 0.3, 0.5, 0.6, 0.5, and 0.1.

Ulmer, M. P.↗

A multipurpose fast neutron beam capability at the MASURCA facility

In this paper we investigate the possible future use of the CEA Cadarache MASURCA experimental fast reactor to generate a fairly high-intensity continuous beam of fast neutrons, having energies distributed in the 1 KeV to 5 MeV range. Such an extracted beam of fast neutrons, tailorable in intensity, size and energy, would be rather unique; it would be of interest to neutron-based research and could open a range of new applications at MASURCA. We report the results of numerical simulations which have been performed to evaluate the feasibility of such a beam port and to characterize it spectrally. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-T-126: Microdosimetic Evaluation of Proton Energy Distributions in the Vicinity of Metal Implants

Purpose: To evaluate the impact of titanium and surgical stainless steel implants on the microscopic dose distribution in proton treatment plans Methods: Geant4 Monte Carlo simulations were used to analyze the microdosimetric distribution of proton radiation in the vicinity of 3.1 mm thick CP Grade 4 titanium (Ti) or 316 stainless steel (SS316) plates in a water phantom. Additional simulations were performed using either water, or water with a density equivalent to the respective metals (Tiwater, SS316water) (to reflect common practice in treatment planning). Implants were placed at the COM of SOBPs of 157 MeV (range of ∼15 cm in water) protons with 30 or 60 mm modulation. Primary and secondary particle dose and fluence, frequency-weighted and dose-weighted average lineal energy, average radiation quality factor, dose equivalent and energy deposition histograms in the plate vicinity were compared. Results: Preliminary results show frequency-weighted (yf) and dose-weighted lineal energy (yd) was increased downstream of the Ti plate (yf = 3.1 keV/µm; yd = 5.5 keV/µm) and Tiwater (yf = 4.1 keV/µm; yd = 6.8 keV/µm) compared to that of water (ie, the absence of a plate) (yf = 2.5 keV/µm; yd = 4.5 keV/µm). In addition, downstream proton dose deposition was also elevated due to the presence of the Ti plate or Tiwater. The additional dose deposited at higher lineal energy implies that tissues downstream of the plate will receive a higher dose equivalent. Detailed analyses of the Ti, Tiwater, SS316, and SS316 water simulations will be presented. Conclusion: The presence of high-density materials introduces changes in the spatial distribution of radiation in the vicinity of an implant. Further work quantifying these effects could be incorporated into future treatment planning systems resulting in more accurate treatment plans. This project was sponsored with funding from the Department of Defense (DOD # W81XWH-10-2-0192).

07 ISOTOPE AND RADIATION SOURCES↗

Progress with applications of three-ion ICRF scenarios for fusion research: A review

The viability of magnetic confinement fusion as an energy source depends on achieving the high ion temperatures required for D-T fusion. Among the available techniques, plasma heating with waves in the ion cyclotron range of frequencies (ICRF) is a prominent method for bulk ion heating in fusion plasmas. Furthermore, a detailed understanding of the non-linear physics of alpha heating and the complex impact of MeV-range fast ions on plasma dynamics becomes progressively more important. This paper provides a comprehensive overview of recent developments with the three-ion ICRF scenarios on Alcator C-Mod, ASDEX Upgrade and JET tokamaks. The results demonstrate the flexibility of these novel scenarios for heating bulk ions in D-T ≈ 50%-50% plasmas and efficient generation of MeV-range fast ions in multi-ion species plasmas. In conclusion, several key results relevant for ITER and future fusion reactors are highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE ROLE OF STOCHASTIC ACCELERATION IN THE PROMPT EMISSION OF GAMMA-RAY BURSTS: APPLICATION TO HADRONIC INJECTION

We study effects of particle re-acceleration (or heating) in the post-shock region via magnetohydrodynamic/plasma turbulence, in the context of a mixed hadronic-leptonic model for the prompt emission of gamma-ray bursts, using both analytical and numerical methods. We show that stochastically accelerated (or heated) leptons, which are injected via pp and p{gamma} reactions and subsequent pair cascades, are plausibly able to reproduce the Band function spectra with {alpha} {approx} 1 and {beta} {approx} 2-3 in the {approx}MeV range. An additional hard component coming from the proton-induced cascade emission is simultaneously expected, which can be compatible with observed extra power-law spectra far above the MeV range. We also discuss the specific implications of hadronic models for ongoing high-energy neutrino observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than ± 1% with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 × 4 array of 6 mm × 6 mm × 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of ≈270 e - rms for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8% FWHM at 238 keV and 0.9% FWHM at 662 keV.

3D↗

Neutron dosimetry in low-earth orbit using passive detectors

This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.

Flight Experiment↗

A viable QCD axion in the MeV mass range

The QCD axion is one of the most compelling solutions of the strong CP problem. There are major current efforts into searching for an ultralight, invisible axion, which is believed to be the only phenomenologically viable realization of the QCD axion. Visible axions with decay constants at or below the electroweak scale are believed to have been long excluded by laboratory searches. Considering the significance of the axion solution to the strong CP problem, we revisit experimental constraints on QCD axions in the O(10 MeV) mass window. In particular, we find a variant axion model that remains compatible with existing constraints. This model predicts new states at the GeV scale coupled hadronically, and a variety of low-energy axion signatures, such as rare meson decays, nuclear de-excitations via axion emission, and production in e + e - annihilation and fixed target experiments. This reopens the possibility of solving the strong CP problem at the GeV scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extension of the neutron scatter camera sensitivity to the ~10–200 MeV neutron energy range

The Neutron Scatter Camera (NSC) is a neutron spectrometer and imager that has been developed and improved by the Sandia National Laboratories for several years. Built for special nuclear material searches, the instrument was configured by the design to reconstruct neutron sources within the fission energy range 1–10 MeV. In this work, we present modifications that attempt to extend the NSC sensitivity to neutron energies in the range ~10–200 MeV and discuss the corresponding consequences for the event processing. We present simulation results that manifest important aspects of the NSC response to those intermediate energy neutrons. The simulation results also evidence that the instrument’s spectroscopic capabilities severely deteriorate at those energies, mainly due to the uncertainties in measuring energy, time, and distance between the two neutron scattering interactions. Furthermore, this work is motivated by the need to characterize neutron fluxes at particle accelerators as they may represent important backgrounds for neutrino experiments.

47 OTHER INSTRUMENTATION↗

Low energy muon neutrino reconstruction in MicroBooNE

MicroBooNE is a Liquid Argon Time Projection Chamber (LArTPC) neutrino experiment on the Booster Neutrino Beamline at the Fermi National Accelerator Laboratory, with an 85-tonne active mass. One of MicroBooNE’s primary physics goals is to investigate the excess of electron neutrino events seen by MiniBooNE in the [200-600] MeV range. MicroBooNE will constrain the intrinsic electron neutrino component of the beam by measuring the muon neutrino spectrum. Several low-energy excess analyses are taking place in parallel, using independent reconstructions and selection schemes. This paper will focus on a low-energy excess analysis that makes use of deep learning algorithms applied to the high-resolution images provided by the MicroBooNE LArTPC. We present a novel 3D event reconstruction based on computer vision tools and a stochastic search algorithm, yielding a 2.2% energy resolution for 1μ1p muon neutrino interactions in the [200-1500] MeV range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEM Grid Testing at NLCTA in BeamNetUS Program

We report on the performance of a secondary electron monitor (SEM) grid used to measure the transverse profile of an MeV range electron beam at SLAC National Accelerator Laboratory’s Next Linear Collider Test Accelerator (NLCTA) facility. When inserted into the path of the electron beam, secondary electron emission results in a measurable current on the wires that make up the grid. We present measurements using this technique to reconstruct the beam profile. The SEM grid was designed and manufactured by a team of undergraduate students at Harvey Mudd College (HMC) and was tested at SLAC’s NLCTA facility in collaboration with NCLTA staff as part of the BeamNetUS program. Developed for real-time diagnostics of MeV-range electron beams, this SEM grid has potential applications in both industrial and medical contexts.

43 PARTICLE ACCELERATORS↗

Simulation of Prompt Emission from GRBs with a Photospheric Component and its Detectability By GLAST

The prompt emission from gamma-ray bursts (GRBs) still requires a physical explanation. Studies of time-resolved GRB spectra, observed in the keV-MeV range, show that a hybrid model consisting of two components, a photospheric and a non-thermal component, in many cases fits bright, single-pulsed bursts as well as, and in some instances even better than, the Band function. With an energy coverage from 8 keV up to 300 GeV, GLAST will give us an unprecedented opportunity to further investigate the nature of the prompt emission. In particular, it will give us the possibility to determine whether a photospheric component is the determining feature of the spectrum or not. Here we present a short study of the ability of GLAST to detect such a photospheric component in the sub-MeV range for typical bursts, using simulation tools developed within the GLAST science collaboration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron-induced fission cross section measurement of 233 U, 241 Am and 243 Am in the energy range 0.5 MeV En 20 MeV at n TOF at CERN

Neutron-induced fission cross section measurements of 233U, 243Am and 241Am relative to 235U have been carried out at the neutron time-of-flight facility n TOF at CERN. A fast ionization chamber has been employed. All samples were located in the same detector; therefore the studied elements and the reference 235U target are subject to the same neutron beam.

Belloni, F.↗

Importance of Thomas single-electron transfer in fast p-He collisions

We report experimental angular differential cross sections for nonradiative single-electron capture in p-He collisions (p+ He -> H + He{sup +}) with a separate peak at the 0.47 mrad Thomas scattering angle for energies in the 1.3-12.5 MeV range. We find that the intensity of this peak scales with the projectile velocity as v{sub P}{sup -11}. This constitutes the first experimental test of the prediction from 1927 by L. H. Thomas [Proc. R. Soc. 114, 561 (1927)]. At our highest energy, the peak at the Thomas angle contributes with 13.5% to the total integrated nonradiative single-electron capture cross section.

74 ATOMIC AND MOLECULAR PHYSICS↗

Data analysis for Skylab proton spectrometer

The data from a proton spectrometer flown aboard Skylab is examined. The instrument is sensitive to protons in the energy range 18 to 400 MeV. A partial failure of the spectrometer restricted spectral analysis to two energy bands, 18 to 27 MeV and 27 to 400 MeV. The directional data showed that a Gaussian angular distribution parameter of at least 70 degrees is required for the low energy band and at least 40 degrees for the high energy band. The data, integrated over angle, indicate that the AP3 model extrapolated down to 18-27 MeV is high by factors of 2 to 5 over most of the B-L space mapped. In the 27 to 400 MeV range, the AP3 model is 20 to 100 percent low at low and high values of L, and is high at medium L values in the B-L space mapped.

Hill, C. W.↗