Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MASER RESONATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A hydrogen maser with cavity auto-tuner for timekeeping

A hydrogen maser frequency standard for timekeeping was worked on at the Shanghai Observatory. The maser employs a fast cavity auto-tuner, which can detect and compensate the frequency drift of the high-Q resonant cavity with a short time constant by means of a signal injection method, so that the long term frequency stability of the maser standard is greatly improved. The cavity auto-tuning system and some maser data obtained from the atomic time comparison.

C. F. Lin

Simple waveguide reflection maser with broad tunability

The design and performance of a simple two-stage reflection maser for use between 9 and 10 GHz are described. The maser is used to improve the sensitivity of a transmission electron spin resonance spectrometer. A ruby-filled waveguide structure permits broad tunability and straightforward construction. All microwave components except the ruby section are at room temperature.

Flesner, L. D.

Cryogenic masers

Various factors affecting the frequency stability of hydrogen masers are described and related to maser design parameters. The long-term frequency stability of a hydrogen maser is limited by the mechanical stability of the cavity, and the magnitudes of the wall relaxation, spin exchange, and recombination rates which affect the Q of the line. Magnetic resonance studies of hydrogen atoms at temperatures below 1 K and in containers coated with liquid helium films demonstrated that cryogenic masers may allow substantial improvements in all of these parameters. In particular the thermal expansion coefficients of most materials are negligible at 1 K. Spin exchange broadening is three orders of magnitude smaller at 1 K than at room temperature, and the recombination and wall relaxation rates are negligible at 0.52 K where the frequency shift due to the 4 He-coated walls of the container has a broad minimum as a function of temperature. Other advantages of the helium-cooled maser result from the high purity, homogeneity, and resilence of helium-film-coated walls and the natural compatibility of the apparatus with helium-cooled amplifiers.

Berlinsky, A. J.

Hydrogen masers with cavity frequency switching servos

The stability of the free-running hydrogen maser is limited by pulling of the unperturbed hydrogen transition frequency due to instability of the cavity resonance frequency. While automatic spin-exchange tuning is in principle the more basic and accurate method, the required beam intensity switching and the long servo time constant result in reduced stability for measuring intervals up to 10(exp 6) seconds. More importantly, the spin-exchange tuning method requires a second stable frequency source as a reference, ideally a second hydrogen maser, to get the best results. The cavity frequency switching servo, on the other hand, has very little effect on the maser short term stability, and is fast enough to correct for cavity drift while maintaining the cavity at the spin-exchange tuned offset required to minimize instability due to beam intensity fluctuations. Not only does the cavity frequency switching servo not require a second stable frequency source, but the frequency reference is the atomic hydrogen radiated beam signal, so that no extra RF connections need be made to the cavity, and externally generated signals that would perturb the hydrogen atom need not be transmitted through the cavity. The operation of the cavity frequency switching stabilization method is discussed and the transient response of the servo and certain other aspects of the technique that have potential for achieving improved basic accuracy are illustrated.

Peters, Harry E.

The superconducting cavity stability ruby maser oscillator

Analysis of an application of the rudy maser to a superconducting Cavity Stabilized oscillator shows many attractive features. These derive from the mechancial stability inherent in an all-cryogenic design and from the properties of the ruby maser itself. A multiple-cavity design has been developed to allow physical separation of the high-Q superconducting cavity and the ruby element with its requried applied magnetic field. Mode selection is accomplished in this design by tuning the ruby by means of the applied field. We conclude that such an oscillator would perform well, even with cavity Q's as low as 10 to the 8th power allowing the use of a superconductor-on-sapphire resonator with its greater rigidity and lower thermal expansion. A first test of the Superconducting Cavity Stabilized Maser Oscillator (SCSMO) confirms the efficacy of the multiple-cavity design and the applicability of the ruby maser. Frequency variation less than 4x10 to the minus 11th power was measured in the stabilized mode and is attributed to the reference oscillator and to instabilities in the pump source. Variation of 10 to the minus 10th power was observed in the low-Q unstabilized mode, again attributable to pump fluctuations. Even so, direct scaling to a Q of 10 the 9th power predicts a stability better than 10 to the minus 15th power. Together with results showing the lowest losses to date in sapphire at microwave frequencies, and preliminary experiments on superconductor-on-sapphire resonators, frequency stability, levels as low as 10 to the minus 17th power are indicated.

Dick, G. J.

Electromagnetic particle simulation codes

Electromagnetic particle simulations solve the full set of Maxwell's equations. They thus include the effects of self-consistent electric and magnetic fields, magnetic induction, and electromagnetic radiation. The algorithms for an electromagnetic code which works directly with the electric and magnetic fields are described. The fields and current are separated into transverse and longitudinal components. The transverse E and B fields are integrated in time using a leapfrog scheme applied to the Fourier components. The particle pushing is performed via the relativistic Lorentz force equation for the particle momentum. As an example, simulation results are presented for the electron cyclotron maser instability which illustrate the importance of relativistic effects on the wave-particle resonance condition and on wave dispersion.

Pritchett, P. L.

State of the art and future directions for the atomic hydrogen maser

The present status of technology development for atomic hydrogen masers (H-masers) is reviewed. The limitations to frequency stability and accuracy are discussed with emphasis on the problems associated with cavity resonator instability and the lack of reproducibility and stability of the storage volume wall coating frequency shift. New types of coating developed in the Soviet Union and better, cavity resonator materials, are expected to make possible frequency at the 10(exp -16) level at 10(exp 4) sec. Better control of systematic effects should extend the long-term stability to levels better than 10(exp -15) for intervals beyond one day. Present use of H-masers as flywheel oscillators in timekeeping systems is discussed as is the outlook for the future cryogenic and room temperature H-masers as flywheel oscillators to operate very high resolution frequency discriminators based on the newly evolving technology of trapped and cooled ions and atoms.

Vessot, Robert F. C.

Auroral kilometric radiation - An example of relativistic wave-particle interaction in geoplasma

The earth's auroral kilometric radiation (AKR) is believed to be produced by the electron-cyclotron maser instability. This instability is the result of a wave-particle interaction in which relativistic effects are crucial. An explanation is given as to how these relativistic effects alter the shape of the resonance curve in velocity space and modify the R - X mode wave dispersion near the electron cyclotron frequency compared to the results obtained in the nonrelativistic limit and from cold-plasma theory. The properties of the cyclotron maser instability in a driven system are illustrated using two-dimensional electromagnetic particle simulations which incorporate a continual flow of primary energetic electrons along the magnetic field.

Pritchett, P. L.

Methods to recover the narrow Dicke sub-Doppler feature in evacuated wall-coated cells without restrictions on cell size

The hyperfine resonance observed in evacuated wall-coated cells with dimensions lambda/2 (lambda is the hyperfine resonance wavelength) consists of a narrow Dicke sub-Doppler linewidth feature, the spike, superimposed on a broad pedestal. The hydrogen maser provides a classic example of this lineshape. As cell size is increased, an effect unique to evacuated wall-coated cells occurs. Certain combinations of microwave field distribution and cell size result in a lineshape having a pedestal with a small spike feature or only the broad pedestal with no spike. Such conditions are not appropriate for atomic frequency standard applications. The cause of the evacuated wall-coated cell lineshape is reviewed and methods to recover the narrow spike feature without restrictions on cell size is discussed. One example is a cell with dimensions having equal volumes of exposure to opposite phases of the microwave magnetic field.

Robinson, H. G.

Particle propagation effects on wave growth in a solar flux tube

The evolution of a distribution of electrons is followed after they are injected impulsively at the top of a coronal magnetic loop, with the objective of studying the plasma instabilities which result. At early times the downgoing electrons have beamlike distributions and amplify electrostatic waves via the Cerenkov resonance; the anomalous Doppler resonance is found to be less important. Slightly later, while the electrons are still predominantly downgoing, they are unstable to cyclotron maser generation of z-mode waves with omega(p) much less than Omega, or to second harmonic x-mode waves. The energetics of these instabilities, including saturation effects and heating of the ambient plasma, are discussed. It is suggested that coalescence of two z-mode waves generated by cyclotron maser emission of the downgoing electrons may produce the observed microwave spike bursts.

White, S. M.

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The cryogenic hydrogen maser (CHM) developed at the Smithsonian Astrophysical Observatory (SAO) was designed to be functionally similar to SAO room temperature hydrogen masers with appropriate modifications made for operation at cryogenic temperatures. A schematic of the SAO CHM is shown in Figure 1, and a description of this device and its operation follows. A beam of molecular hydrogen is dissociated into atoms at room temperature. The resultant beam of atomic hydrogen is then cooled, magnetically state selected, and focused into a quartz storage bulb centered inside of a microwave cavity resonant with the hydrogen hyperfine transition at 1420 MHz. The quartz storage bulb is coated with a superfluid He-4 film, and both the bulb and cavity are maintained near 0.5 K. The maser signal is coupled out inductively and carried to room temperature via semi-rigid coaxial cable. After passing through a room temperature isolator and preamp, the maser signal is detected with a low-noise heterodyne receiver as used in the room temperature SAO hydrogen masers. The maser temperature is lowered to 0.5 K using a recirculating He-3 refrigerator. This refrigerator consists of several cooling stages: a liquid nitrogen stage at 77 K, a liquid 4He bath at 4.2 K, a pumped He-4 pot at approximately 1.7 K, and the pumped, recirculating He-3 stage at 0.5 K. The atomic hydrogen beam, state selector, storage bulb and cavity are all connected inside a single, maser vacuum chamber (MVC). This space is pumped out from below by a turbo pump. Above the MVC, an inlet to the space allows for the input of flowing superfluid 4He film. External to the MVC is a second, outer vacuum chamber (OVC), maintained for operation of the cryostat and also pumped by a turbo pump. Inside the OVC, there is radiation shielding at 77 K and 1.7 K.

Walsworth, Ronald L.

Electron cyclotron maser emission at oblique angles

Possible causes of observations of electron cyclotron maser emissions (ECMEs) at oblique angle (about 60 deg) to the magnetic field are investigated. The paper discusses general concepts of ECME in terms of resonant ellipses and considers electron distributions required to produce ECME at oblique angles, as well as the ways in which the most favorable of these distributions may be produced. A mechanism is proposed that might produce an appropriate 'spiraling beam' distribution, with a peak in velocity space at speed v - v(0) and pitch angle alpha = alpha(0) not equal to 0.

Melrose, D. B.

Optical and infrared masers

Ongoing research progress in the following areas is described: (1) tunable infrared light sources and applications; (2) precision frequency and wavelength measurements in the infrared with applications to atomic clocks; (3) zero-degree pulse propagation in resonant medium; (4) observation of Dicke superradiance in optically pumped HF gas; (5) unidirectional laser amplifier with built-in isolator; and (6) progress in infrared metal-to-metal point contact tunneling diodes.

Source record

Hydrogen as an atomic beam standard

After a preliminary discussion of feasibility, new experimental work with a hydrogen beam is described. A space focused magnetic resonance technique with separated oscillatory fields is used with a monochromatic beam of cold hydrogen atoms which are selected from a higher temperature source. The first resonance curves and other experimental results are presented. These results are interpreted from the point of view of accuracy potential and frequency stability, and are compared with hydrogen maser and cesium beam capabilities.

Peters, H. E.

Continuum radiation in planetary magnetospheres

With the completion of the Voyager tour of the outer planets, radio and plasma wave instruments have executed the first survey of the wave spectra of Earth, Jupiter, Saturn, Uranus, and Neptune. One of the most notable conclusions of this survey is that there is a great deal of qualitative similarity in both the plasma wave and radio wave spectra from one magnetosphere to the next. In particular, in spite of detailed differences, most of the radio emissions at each of the planets have been tentatively classified into two primary categories. First, the most intense emissions are generally associated with the cyclotron maser instability. Second, a class of weaker emissions can be found at each of the magnetospheres which appears to be the result of conversion from intense electrostatic emissions at the upper hybrid resonance frequency into (primarily) ordinary mode radio emission. It is this second category, often referred to as nonthermal continuum radiation, which we will discuss in this review. We review the characteristics of the continuum spectrum at each of the planets, discuss the source region and direct observations of the generation of the emissions where available, and briefly describe the theories for the generation of the emissions. Over the past few years evidence has increased that the linear mode conversion of electrostatic waves into the ordinary mode can account for at least some of the continuum radiation observed. There is no definitive evidence which precludes the possibility that a nonlinear mechanism may also be important.

Kurth, W. S.

External bulb variable volume maser

A maser functioning as a frequency standard stable to one part in 10 to the 14th power includes a variable volume, constant surface area storage bulb having a fixed volume portion located in a resonant cavity from which the frequency standard is derived. A variable volume portion of the bulb, exterior to the resonant cavity, has a maximum volume on the same order of magnitude as the fixed volume bulb portion. The cavity has a length to radius ratio of at least 3:1 so that the operation is attained without the need for a feedback loop. A baffle plate, between the fixed and variable volume bulb portions, includes apertures for enabling hydrogen atoms to pass between the two bulb portions and is an electromagnetic shield that prevents coupling of the electromagnetic field of the cavity into the variable volume bulb portion.

Reinhardt, V. S.

Remote Detection Sodium Cell Magnetometry Using Amplitude Modulated Light

We have investigated the performance of a remote-detection sodium cell magnetometer using synchronous optical pumping with amplitude modulated light. The magnetometer is used to measure ambient geomagnetic field with high-sensitivity using backscattered resonance fluorescence.

Line shapes and shifts and Spectroscopy