Influence of Viscosity on Dynamic Magnetization of Thermally Blocked Iron Oxide Nanoparticles Characterized by a Sensitive AC Magnetometer

In this work, we show that the viscosity of carrier liquid affects the dynamic magnetization of thermally blocked multi-core iron oxide nanoparticles. The core size of the nanoparticles was determined from the magnetization curve measured by a specially developed high-T{sub c} SQUID magnetometer and calculated to be 11.7 nm. Using an AC magnetometer developed based on induction coils, the dynamic magnetization of the multi-core iron oxide nanoparticle solution was measured from 3 Hz to 10.48 kHz. Later, we reconstructed of the hydrodynamic size distribution of the particles by assuming a log-normal distribution of particle size in an AC susceptibility model by Shliomis and Stepanov, which accounts for anisotropic directions of the easy axes of magnetic nanoparticles with respect to the excitation field direction. The reconstructed hydrodynamic sizes showed an average diameter of 130 nm and agreed with the size determined by dynamic light scattering method. In the case of increasing viscosity of the carrier liquids from 0.89 to 8.11 mPa s, the dynamic magnetization peaks of the imaginary component have shifted to a lower frequency region. We showed that the harmonics ratio and phase delay upon the magnetic field excitation at 30 Hz could also be used to determine the viscosity of carrier liquid independently.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A spin-wave magnetometer with a positive feedback

In this work, we demonstrate experimentally the operation of a spin-wave magnetometer integrated into a circuit with a positive feedback. The circuit consists of the passive magnetic and active electric parts. The magnetic part includes a sensing element, which is a magnetic cross junction made of Y 3 Fe 2 (FeO 4 ) 3 . The electric part includes a non-linear amplifier and a phase shifter. The electric and magnetic parts are connected via micrometer size antennae. Spin waves are excited by two of these antennae while the output inductive voltage produced by the interfering spin waves is detected by the third antenna. Spin waves propagating in the orthogonal arms of the cross can accumulate significantly different phase shifts, depending on the direction and the strength of the external magnetic field. The output inductive voltage reaches its maximum in the case of constructive spin wave interference. The positive feedback provides further signal amplification. It appears possible to enhance the response function, compared to the passive circuits without a feedback, by a factor of ×100 without an increase in the noise level. The experimental data show a prominent response to the external magnetic field variation, exceeding 5 x 10 3 V/T. The intrinsic noise spectral density of the device can be as low as 10 -16 V 2 /Hz. The estimated sensitivity of the prototype device is 2 x 10 -12 T/√Hz at room temperature. We argue that spin-wave magnetometers can potentially be as sensitive as SQUIDs while operating at room temperature.

36 MATERIALS SCIENCE↗

Automated system for the calibration of magnetometers

A completely nonmagnetic calibration platform has been developed and constructed at DTU Space (Technical University of Denmark). It is intended for on-site scalar calibration of high-precise fluxgate magnetometers. An enhanced version of the same platform is being built at the Czech Technical University. There are three axes of rotation in this design (compared to two axes in the previous version). The addition of the third axis allows us to calibrate more complex devices. An electronic compass based on a vector fluxgate magnetometer and micro electro mechanical systems (MEMS) accelerometer is one example. The new platform can also be used to evaluate the parameters of the compass in all possible variations in azimuth, pitch, and roll. The system is based on piezoelectric motors, which are placed on a platform made of aluminum, brass, plastic, and glass. Position sensing is accomplished through custom-made optical incremental sensors. The system is controlled by a microcontroller, which executes commands from a computer. The properties of the system as well as calibration and measurement results will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of high field SQUID magnetometer for magnetization studies up to 7 T and temperatures in the range from 4.2 to 300 K

We present the design, fabrication, integration, testing, and calibration of a high field superconducting quantum interference device (SQUID) magnetometer. The system is based on dc SQUID sensor with flux locked loop readout electronics. The design is modular and all the subsystems have been fabricated in the form of separate modules in order to simplify the assembly and for ease of maintenance. A novel feature of the system is that the current induced in the pickup loop is distributed as inputs to two different SQUID sensors with different strengths of coupling in order to improve the dynamic range of the system. The SQUID magnetometer has been calibrated with yttrium iron garnet (YIG) sphere as a standard reference material. The calibration factor was determined by fitting the measured flux profile of the YIG sphere to that expected for a point dipole. Gd{sub 2}O{sub 3} was also used as another reference material for the calibration and the effective magnetic moment of the Gd{sup 3+} could be evaluated from the temperature dependent magnetization measurements. The sensitivity of the system has been estimated to be about 10{sup -7} emu at low magnetic fields and about 10{sup -5} emu at high magnetic fields {approx}7 T.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of ac and dc magnetometers with a Dy{sub 2}O{sub 3} standard

The ac susceptibility and magnetization curves of a glued Dy{sub 2}O{sub 3} powder sample are measured by an ac susceptometer and a dc superconducting quantum interference device magnetometer, both of which have been calibrated previously. It is shown that the magnetic moment of the paramagnetic sample as a function of field and temperature may be accurately expressed by a combination of the Curie-Weiss law and the Langevin function at T > 45 K with three adjusting parameters, so that the dc magnetization curves and the magnitude and phase of ac susceptibility at different values of dc bias field measured by any magnetometer can be calibrated by using Dy{sub 2}O{sub 3} as a standard. The expressions are empirical and cannot be justified in the entire field and temperature range by existing theories of paramagnetism. Below 10 K, indication of approaching a possible phase transition is found. It is shown that pure Dy{sub 2}O{sub 3} powder may be used as a primary standard, with susceptibility [13.28(T+ 17)]{sup -1} emu/Oe/g at T > 50 K and H < 10 kOe, in consistency with the Curie-Weiss law and the quantum mechanical theory of paramagnetism.

36 MATERIALS SCIENCE↗

A high-sensitivity push-pull magnetometer

We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/√(Hz), using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/√(Hz)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ magnetic compensation for potassium spin-exchange relaxation-free magnetometer considering probe beam pumping effect

A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz{sup 1/2}, which was mainly dominated by the noise of the magnetic shield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined alternating gradient force magnetometer and susceptometer system

We report the design, fabrication, and characterization of a new system that combines the performances of two different types of magnetic characterization systems, Alternating Gradient Force Magnetometers (AGFM) and susceptometers. The flexibility of our system is demonstrated by its capability to be used as any of them, AGFM or susceptometer, without any modification in the experimental set-up because of the electronics we have developed. Our system has a limit of sensitivity lower than 5 × 10{sup −7} emu. Moreover, its main advantage is demonstrated by the possibility of measuring small quantities of materials under DC or AC magnetic fields that cannot properly be measured with a commercial vibrating sample magnetometers or AGFM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast determination method for transverse relaxation of spin-exchange-relaxation-free magnetometer

We propose a fast and accurate determination method for transverse relaxation of the spin-exchange-relaxation-free (SERF) magnetometer. This method is based on the measurement of magnetic resonance linewidth via a chirped magnetic field excitation and the amplitude spectrum analysis. Compared with the frequency sweeping via separate sinusoidal excitation, our method can realize linewidth determination within only few seconds and meanwhile obtain good frequency resolution. Therefore, it can avoid the drift error in long term measurement and improve the accuracy of the determination. As the magnetic resonance frequency of the SERF magnetometer is very low, we include the effect of the negative resonance frequency caused by the chirp and achieve the coefficient of determination of the fitting results better than 0.998 with 95% confidence bounds to the theoretical equation. The experimental results are in good agreement with our theoretical analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the operation temperature in the spin-exchange relaxation free magnetometer

We study the influence of the cell temperature on the sensitivity of the spin-exchange relaxation free (SERF) magnetometer and analyze the possibility of operating at a low temperature. Utilizing a 25 × 25 × 25 mm{sup 3} Cs vapor cell with a heating temperature of 85 {sup ∘}C, which is almost half of the value of potassium, we obtain a linewidth of 1.37 Hz and achieve a magnetic field sensitivity of 55 fT/Hz{sup 1/2} in a single channel. Theoretical analysis shows that fundamental sensitivity limits of this device with an active volume of 1 cm{sup 3} could approach 1 fT/Hz{sup 1/2}. Taking advantage of the higher saturated vapor pressure, SERF magnetometer based on Cs opens up the possibility for low cost and portable sensors and is particularly appropriate for lower temperature applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-axis atomic magnetometer based on spin precession modulation

We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz{sup 1∕2} is achieved under a bias field of 2 μT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electromagnetic induction imaging with a radio-frequency atomic magnetometer

We report on a compact, tunable, and scalable to large arrays imaging device, based on a radio-frequency optically pumped atomic magnetometer operating in magnetic induction tomography modality. Imaging of conductive objects is performed at room temperature, in an unshielded environment and without background subtraction. Conductivity maps of target objects exhibit not only excellent performance in terms of shape reconstruction but also demonstrate detection of sub-millimetric cracks and penetration of conductive barriers. The results presented here demonstrate the potential of a future generation of imaging instruments, which combine magnetic induction tomography and the unmatched performance of atomic magnetometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution fully vectorial scanning Kerr magnetometer

We report on the development of a high-resolution scanning magnetometer, which fully exploits the vectorial nature of the magneto-optical Kerr effect. The three-dimensional nature of magnetization is at the basis of many micromagnetic phenomena and from these data, we can fully characterize magnetization processes of nanostructures in static and dynamic regimes. Our scanning Kerr magnetometer uses a high numerical aperture microscope objective where the incident light beam can be deterministically deviated from the objective symmetry axis, therefore, both in-plane (via the longitudinal Kerr effect) and out-of-plane (via the polar Kerr effect) components of the magnetization vector may be detected. These components are then separated by exploiting the symmetries of the polar and longitudinal Kerr effects. From four consecutive measurements, we are able to directly obtain the three orthogonal components of the magnetization vector with a resolution of 600 nm. Performance of the apparatus is demonstrated by a measurement of 3D magnetization vector maps showing out-of-plane domains and in-plane domain walls in an yttrium-iron-garnet film and on a study of magnetization reversal in a 4-μm-wide magnetic disk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light-narrowed optically pumped M{sub x} magnetometer with a miniaturized Cs cell

We demonstrate a way of operating an optically pumped magnetometer with miniaturized cesium cell using the light-narrowing effect. The magnetometer setup shows improvement of shot-noise-limited sensitivity (42 fT/{radical}(Hz) in a cell of only 9.3 mm{sup 3} volume) due to the suppression of spin-exchange relaxation to a large extent and the use of a strikingly increased fraction of alkali-metal atoms for signal generation, working even in {mu}T magnetic fields, by using only a single high-intensity laser beam both for pumping and probing of atomic spins.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuned cavity magnetometer sensitivity.

We have developed a high sensitivity (<pico Tesla/{radical}Hz), non-cryogenic magnetometer that utilizes a novel optical (interferometric) detection technique. Further miniaturization and low-power operation are key advantages of this magnetometer, when compared to systems using SQUIDs which require liquid Helium temperatures and associated overhead to achieve similar sensitivity levels.

47 OTHER INSTRUMENTATION↗

Ultra-sensitive Magnetic Microscopy with an Atomic Magnetometer

The PowerPoint presentation focused on research goals, specific information about the atomic magnetometer, response and resolution factors of the SERF magnetometer, FC+AM systems, tests of field transfer and resolution on FC, gradient cancellation, testing of AM performance, ideas for a multi-channel AM, including preliminary sensitivity testing, and a description of a 6 channel DAQ system. A few ideas for future work ended the presentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers

Electrodiagnosis is routinely integrated into clinical neurophysiology practice for peripheral nerve disease diagnoses, such as neuropathy, demyelinating disorders, nerve entrapment/impingement, plexopathy, or radiculopathy. Measured with conventional surface electrodes, the propagation of peripheral nerve action potentials along a nerve is the result of ionic current flow which, according to Ampere’s Law, generates a small magnetic field that is also detected as an “action current” by magnetometers, such as superconducting quantum interference device (SQUID) Magnetoencephalography (MEG) systems. Optically pumped magnetometers (OPMs) are an emerging class of quantum magnetic sensors with a demonstrated sensitivity at the 1 fT/√Hz level, capable of cortical action current detection. But OPMs were ostensibly constrained to low bandwidth therefore precluding their use in peripheral nerve electrodiagnosis. With careful OPM bandwidth characterization, we hypothesized OPMs may also detect compound action current signatures consistent with both Sensory Nerve Action Potential (SNAP) and the Hoffmann Reflex (H-Reflex). In as much, our work confirms OPMs enabled with expanded bandwidth can detect the magnetic signature of both the SNAP and H-Reflex. Taken together, OPMs now show potential as an emerging electrodiagnostic tool.

60 APPLIED LIFE SCIENCES↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗