Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Detectability of Neuronal Currents in Human Brain with Magnetic Resonance Spectroscopy.

Magnetic resonance spectroscopy has been used in a high-risk, high-payoff search for neuronal current (NC) signals in the free induction decay (FID) data from the visual cortex of human subjects during visual stimulation. If successful, this approach could make possible the detection of neuronal currents in the brain at high spatial and temporal resolution. Our initial experiments indicated the presence of a statistically significant change in the FID containing the NC relative to FIDs with the NC absent, and this signal was consistent with the presence of NC. Unfortunately, two follow-on experiments were not able to confirm or replicate the positive findings of the first experiment. However, even if the result from the first experiment were evidence of NC in the FID, it is clear that its effect is so small, that a true NC imaging experiment would not be possible with the current instrumentation and experimental protocol used here.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Heat flux modeling using ion drift effects in DIII-D H-mode plasmas with resonant magnetic perturbations

The heat flux patterns measured in low-collisionality DIII-D H-mode plasmas strongly deviate from simultaneously measured CII emission patterns, used as indicator of particle flux, during applied resonant magnetic perturbations. While the CII emission clearly shows typical striations, which are similar to magnetic footprint patterns obtained from vacuum field line tracing, the heat flux is usually dominated by one large peak at the strike point position. The vacuum approximation, which only considers applied magnetic fields and neglects plasma response and plasma effects, cannot explain the shape of the observed heat flux pattern. One possible explanation is the effect of particle drifts. This is included in the field line equations and the results are discussed with reference to the measurement. Electrons and ions show different drift motions at thermal energy levels in a guiding center approximation. While electrons hardly deviate from the field lines, ions can drift several centimetres away from field line flux surfaces. A model is presented in which an ion heat flux, based on the ion drift motion from various kinetic energies as they contribute to a thermal Maxwellian distribution, is calculated. The simulated heat flux is directly compared to measurements with a varying edge safety factor q{sub 95}. This analysis provides evidence for the dominate effect of high-energy ions in carrying heat from the plasma inside the separatrix to the target. High-energy ions are deposited close to the unperturbed strike line, while low-energy ions can travel into the striated magnetic topology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Magnetic Resonance Measurements and Electronic Structure of Pu(IV) in [(Me)4N]2PuCl6

The synthesis, electronic structure, and characterization via single crystal X-ray diffraction, nuclear magnetic resonance (NMR) spectroscopy, and magnetic susceptibility of (Me4N)2PuCl6 are reported. NMR measurements were performed to both search for the direct 239Pu resonance and to obtain local magnetic and electronic information at the Cl site through 35Cl and 37Cl spectra. No signature of 239Pu NMR was observed. The temperature dependence of the Cl spectra was simulated by diagonalizing the Zeeman and quadrupolar Hamiltonians for 35Cl, 37Cl and 14N isotopes. Electronic structure calculations predict a magnetic ?5 triplet ground state of Pu(IV) in the crystalline electric field of the undistorted PuCl6 octahedron. A tetragonal distortion would result in a very small splitting (20 cm-1) of the triplet ground state into a nonmagnetic singlet and a doublet state. The Cl shifts have an inflection point at T = 15 K, differing from the bulk susceptibility, indicating a nonmagnetic crystal field ground state. The Cl spin-lattice relaxation time is constant down to T = 15 K, below which it rapidly increases, also supporting the nonmagnetic crystal field ground state.

Mounce, Andrew M.↗

Novel synthesis and structural characterization of a high-affinity paramagnetic kinase probe for the identification of non-ATP site binders by nuclear magnetic resonance.

To aid in the pursuit of selective kinase inhibitors, we have developed a unique ATP site binder tool for the detection of binders outside the ATP site by nuclear magnetic resonance (NMR). We report here the novel synthesis that led to this paramagnetic spin-labeled pyrazolopyrimidine probe (1), which exhibits nanomolar inhibitory activity against multiple kinases. We demonstrate the application of this probe by performing NMR binding experiments with Lck and Src kinases and utilize it to detect the binding of two compounds proximal to the ATP site. The complex structure of the probe with Lck is also presented, revealing how the probe fits in the ATP site and the specific interactions it has with the protein. We believe that this spin-labeled probe is a valuable tool that holds broad applicability in a screen for non-ATP site binders.

59 BASIC BIOLOGICAL SCIENCES↗

Partial homogeneity based high-resolution nuclear magnetic resonance spectra under inhomogeneous magnetic fields

In nuclear magnetic resonance (NMR) technique, it is of great necessity and importance to obtain high-resolution spectra, especially under inhomogeneous magnetic fields. In this study, a method based on partial homogeneity is proposed for retrieving high-resolution one-dimensional NMR spectra under inhomogeneous fields. Signals from series of small voxels, which characterize high resolution due to small sizes, are recorded simultaneously. Then, an inhomogeneity correction algorithm is developed based on pattern recognition to correct the influence brought by field inhomogeneity automatically, thus yielding high-resolution information. Experiments on chemical solutions and fish spawn were carried out to demonstrate the performance of the proposed method. The proposed method serves as a single radiofrequency pulse high-resolution NMR spectroscopy under inhomogeneous fields and may provide an alternative of obtaining high-resolution spectra of in vivo living systems or chemical-reaction systems, where performances of conventional techniques are usually degenerated by field inhomogeneity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparison of Radiation-Induced and High-Field Electrically Stress-Induced Interface Defects in Si/SiO 2 MOSFETs via Electrically Detected Magnetic Resonance

Here, we utilize electrically detected magnetic resonance (EDMR) measurements to compare high-field stressed, and gamma irradiated Si/SiO 2 metal–oxide–silicon (MOS) structures. We utilize spin-dependent recombination (SDR) EDMR detected using the Fitzgerald and Grove dc I-V approach to compare the effects of high-field electrical stressing and gamma irradiation on defect formation at and near the Si/SiO 2 interface. As anticipated, both greatly increase the concentration of P b centers (silicon dangling bonds at the interface) densities. The irradiation also generated a significant increase in the dc I-V EDMR response of E' centers (oxygen vacancies in the SiO 2 films), whereas the generation of an E' EDMR response in high-field stressing is much weaker than in the gamma irradiation case. These results likely suggest a difference in their physical distribution resulting from radiation damage and high electric field stressing.

42 ENGINEERING↗

Simulation of magnetic island dynamics under resonant magnetic perturbation with the TEAR code and validation of the results on T-10 tokamak data

Simulation of the magnetic island evolution under Resonant Magnetic Perturbation (RMP) in rotating T-10 tokamak plasma is presented with intent of TEAR code experimental validation. In the T-10 experiment chosen for simulation, the RMP consists of a stationary error field, a magnetic field of the eddy current in the resistive vacuum vessel and magnetic field of the externally applied controlled halo current in the plasma scrape-off layer (SOL). The halo-current loop consists of a rail limiter, plasma SOL, vacuum vessel, and external part of the circuit. Effects of plasma resistivity, viscosity, and RMP are taken into account in the TEAR code based on the two-fluid MHD approximation. Radial distribution of the magnetic flux perturbation is calculated with account of the externally applied RMP. A good agreement is obtained between the simulation results and experimental data for the cases of preprogrammed and feedback-controlled halo current in the plasma SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Line broadening interference for high-resolution nuclear magnetic resonance spectra under inhomogeneous magnetic fields

Nuclear magnetic resonance spectroscopy serves as an important tool for analyzing chemicals and biological metabolites. However, its performance is subject to the magnetic-field homogeneity. Under inhomogeneous fields, peaks are broadened to overlap each other, introducing difficulties for assignments. Here, we propose a method termed as line broadening interference (LBI) to provide high-resolution information under inhomogeneous magnetic fields by employing certain gradients in the indirect dimension to interfere the magnetic-field inhomogeneity. The conventional spectral-line broadening is thus interfered to be non-diagonal, avoiding the overlapping among adjacent resonances. Furthermore, an inhomogeneity correction algorithm is developed based on pattern recognition to recover the high-resolution information from LBI spectra. Theoretical deductions are performed to offer systematic and detailed analyses on the proposed method. Moreover, experiments are conducted to prove the feasibility of the proposed method for yielding high-resolution spectra in inhomogeneous magnetic fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effects of an open and closed divertor on particle exhaust during edge-localized mode suppression by resonant magnetic perturbations in DIII-D

This paper compares the effects of divertor geometry on particle exhaust characteristics during the suppression of ELM using resonant magnetic perturbations (RMPs) on DIII-D. The subject is timely, particularly for ITER, because the combination of techniques to control or mitigate ELMs and control particle exhaust can provide confidence in the ability of an external pumping system to fully remove the particle exhaust. The differences between an open and closed divertor magnetic topology show a strong coupling of the perturbed strikepoint to the pumping manifold in closed divertor configurations, which can increase the particle exhaust by a factor of four. There is also an observed dependence on q95 in this configuration, which is a common feature of RMP ELM suppression. Neutral density in both the active and non-active divertors is seen to increase during the RMP in the ISS configuration, and edge plasma conditions (i.e. ne,sep and midplane profile of Dα) are seen to increase in the closed divertor configuration. Finally, the pumping exhaust is also shown to have a strong dependence on local measurements of the recycling flux. These observations, when taken as a whole, point to a substantial change in the plasma edge conditions, i.e. near the LCFS, throughout the poloidal cross-section of the vacuum vessel. This is coincident with the application of the RMP affecting the pumping capability of the system.

Unterberg, Ezekial↗

Coexistence of antiferromagnetic and ferromagnetic spin correlations in Ca ( Fe 1 - x Co x ) 2 As 2 revealed by As 75 nuclear magnetic resonance

Recent nuclear magnetic resonance (NMR) measurements revealed the coexistence of stripe-type antiferromagnetic (AFM) and ferromagnetic (FM) spin correlations in both the hole- and electron-doped BaFe 2 As 2 families of iron-pnictide superconductors by a Korringa ratio analysis. Motivated by the NMR work, we investigate the possible existence of FM fluctuations in another iron-pnictide superconducting family, Ca ( Fe 1 - x Co x ) 2 As 2 . We reanalyzed our previously reported data in terms of the Korringa ratio and found clear evidence for the coexistence of stripe-type AFM and FM spin correlations in the electron-doped CaFe 2 As 2 system. These NMR data indicate that FM fluctuations exist in general in iron-pnictide superconducting families and thus must be included to capture the phenomenology of the iron pnictides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Volume and Metabolism of Prostate Cancer Determined by Proton Magnetic Resonance Spectroscopic Imaging at 3T Without Endorectal Coil Reveal Potential Clinical Implications in the Context of Radiation Oncology;Prostate cancer; Magnetic resonance spectroscopic imaging; Radiation oncology; Tumor volume; Biomarkers

Purpose: To determine whether a relationship exists between the tumor volume (TV) or relative choline content determined using magnetic resonance spectroscopy imaging (MRSI) at 3T and the clinical prognostic parameters for patients with localized prostate cancer (PCa). Methods and Materials: A total of 72 men (mean age, 67.8 {+-} 6.2 years) were stratified as having low-risk (n = 26), intermediate-risk (n = 24), or high-risk (n = 22) PCa. MRSI was performed at 3T using a phased-array coil. Spectra are expressed as the total choline/citrate, total choline plus creatine/citrate, and total choline plus polyamines plus creatine/citrate ratios. The mean ratio of the most pathologic voxels and the MRSI-based TV were also determined. Results: The mean values of the total choline/citrate, total choline plus creatine/citrate, and total choline plus polyamine plus creatine/citrate ratios were greater for Stage T2b or greater tumors vs. Stage T2a or less tumors: 7.53 {+-} 13.60 vs. 2.31 {+-} 5.65 (p = .018), 8.98 {+-} 14.58 vs. 2.56 {+-} 5.70 (p = .016), and 10.32 {+-} 15.47 vs. 3.55 {+-} 6.16 (p = .014), respectively. The mean MRSI-based TV for Stage T2b or greater and Stage T2a or less tumors was significantly different (2.23 {+-} 2.62 cm{sup 3} vs. 1.26 {+-} 2.06 cm{sup 3}, respectively; p = .030). This TV correlated with increased prostate-specific antigen levels (odds ratio, 1.293; p = .012). Patients with high-risk PCa had a larger TV than did the patients with intermediate-risk PCa. A similar result was found for the intermediate-risk group compared with the low-risk group (odds ratio, 1.225; p = .041). Conclusion: Biomarkers expressing the relative choline content and TV were significant parameters for the localization of PCa and could be helpful for determining the prognosis more accurately.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interaction of Hydrocarbons with Clays under Reservoir Conditions: In Situ Infrared and Nuclear Magnetic Resonance Spectroscopy and X-ray Diffraction for Expandable Clays with Variably Wet Supercritical Methane

The results from novel in situ high-pressure nuclear magnetic resonance (NMR) spectroscopy, infrared (IR) spectroscopy, and X-ray diffraction (XRD) investigation of the interaction of the smectite hectorite with variably wet supercritical methane (scCH4) at 90 bar and 323 K (hydrostatic conditions equivalent to ~1 km depth) show that CH4 occurs in the clay interlayers, in pores external to the individual clay particles, and as bulk fluid. The occupancy of each environment depends on the relative humidity (RH) of the CH4-rich fluid and the hydration energy and size of the charge-balancing cation. As RH increases, the fraction of interlayer and interparticle CH4 decreases, although with Cs+, addition of a small amount of H2O initially increases CH4 uptake. Maximum interlayer CH4 adsorption occurs when the mean basal spacing just permits methane intercalation (~11.5 Å) and never below this basal spacing. It is also higher with divalent cations than with monovalent cations. The data show that CH4 adsorption occurs predominantly via a weak dispersion interaction with the clay and that its intercalation occurs via a passive space-filling hydrophobic mechanism. The results suggest that, under reservoir conditions, smectite interlayers may provide a reservoir for CH4 under low-water conditions.

Bowers, Geoffrey M.↗

Evaluation of Magnetic Resonance Imaging-Compatible Needles and Interactive Sequences for Musculoskeletal Interventions Using an Open High-Field Magnetic Resonance Imaging Scanner

In this article, we study in vitro evaluation of needle artefacts and image quality for musculoskeletal laser-interventions in an open high-field magnetic resonance imaging (MRI) scanner at 1.0T with vertical field orientation. Five commercially available MRI-compatible puncture needles were assessed based on artefact characteristics in a CuSO4 phantom (0.1%) and in human cadaveric lumbar spines. First, six different interventional sequences were evaluated with varying needle orientation to the main magnetic field B0 (0{sup o} to 90{sup o}) in a sequence test. Artefact width, needle-tip error, and contrast-to-noise ratio (CNR) were calculated. Second, a gradient-echo sequence used for thermometric monitoring was assessed and in varying echo times, artefact width, tip error, and signal-to-noise ratio (SNR) were measured. Artefact width and needle-tip error correlated with needle material, instrument orientation to B0, and sequence type. Fast spin-echo sequences produced the smallest needle artefacts for all needles, except for the carbon fibre needle (width <3.5 mm, tip error <2 mm) at 45{sup o} to B0. Overall, the proton density-weighted spin-echo sequences had the best CNR (CNR{sub Muscle/Needle} >16.8). Concerning the thermometric gradient echo sequence, artefacts remained <5 mm, and the SNR reached its maximum at an echo time of 15 ms. If needle materials and sequences are accordingly combined, guidance and monitoring of musculoskeletal laser interventions may be feasible in a vertical magnetic field at 1.0T.

62 RADIOLOGY AND NUCLEAR MEDICINE↗