Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Millimeter-Gap Magnetically Insulated Transmission Line Power Flow Experiments

An experiment platform has been designed to study vacuum power flow in magnetically insulated transmission lines (MITLs). The platform was driven by the 400-GW Mykonos-V accelerator. The experiments conducted quantify the current loss in a millimeter-gap MITL with respect to vacuum conditions in the MITL for two different gap distances, 1.0 and 1.3 mm. The current loss for each gap was measured for three different vacuum pump down times. As a ride along experiment, multiple shots were conducted with each set of hardware to determine if there was a conditioning effect to increase current delivery on subsequent shots. The experiment results revealed large differences in performance for the 1.0 and 1.3 mm gaps. The 1.0 mm gap resulted in current loss of 40%-60% of peak current. The 1.3 mm gap resulted in current losses of less than 5% of peak current. Classical MITL models that neglect plasma expansion predict that there should be zero current loss, after magnetic insulation is established, for both of these gaps. The experiments result s indicate that the vacuum pressure or pump down time did not have a significant effect on the measured current loss at vacuum pressures between 1e-4 and 1e-5 Torr. Additionally, there was not repeatable evidence of a conditioning effect that reduced current loss for subsequent full-energy shots on a given set of hardware. It should be noted that the experiments conducted likely did not have large loss contributions due to ion emission from the anode due to the relatively small current densi-ties (25-40 kA/cm) in the MITL that limited the anode temperature rise due to ohmic heating. The results and conclusions from these experiments may have limited applicability to MITLs of high current density (>400 kA/cm) used in the convolute and load region of the Z which experience temperature increases of >400° C and generate ion emission from anode surfaces.

42 ENGINEERING↗

Nonlocal, diamagnetic electromagnetic effects in magnetically insulated transmission lines

We identify the time-dependent physics responsible for the critical reduction of current losses in magnetically insulated transmission lines (MITLs) due to uninsulated space charge-limited currents of electrons emitted by field stress. A drive current of sufficiently short pulse length introduces a strong enough time dependence that steady-state results alone become inadequate for the complete understanding of current losses. The time-dependent physics can be described as a nonlocal, diamagnetic electromagnetic response of space charge limited currents. As the pulse length is increased or equivalently, the MITL length reduced, these time-dependent effects diminish and current losses converge to those predicted by the well-known Child–Langmuir law in the external (vacuum) fields. We present a simple one-dimensional (1D) model that encapsulates the essence of this physics. We find excellent agreement with 2D particle-in-cell simulations for two MITL geometries, Cartesian parallel plate and azimuthally symmetric straight coaxial. Based on the 1D model, we explore various scaling dependencies of MITL losses with relevant parameters, e.g., peak current, pulse length, geometrical dimensions, etc. We propose an improved physics model of magnetic insulation in the form of a Hull curve, which could also help improve predictions of current losses by common circuit element codes, such as BERTHA. Finally, we describe how to calculate the temperature rise due to electron impact within the 1D model.

Computer simulation↗

An annular high-current electron beam with an energy spread in a coaxial magnetically insulated diode

An elementary theory of an annular high-current electron beam in a uniform transport channel and a coaxial magnetically insulated diode is generalized to the case of counterpropagating electron beams with a spread over kinetic energies. Expressions for the sum of the absolute values of the forward and backward currents in a uniform transport channel and for the flux of the longitudinal component of the generalized momentum in a coaxial magnetically insulated diode as functions of the maximum electron kinetic energy are derived for different values of the relative width of the energy distribution function. It is shown that, in a diode with an expanding transport channel and a virtual cathode limiting the extracted current, counterpropagating particle flows are established between the cathode and the virtual cathode within a certain time interval after the beginning of electron emission. The accumulation of electrons in these flows is accompanied by an increase in their spread over kinetic energies and the simultaneous decrease in the maximum kinetic energy. The developed model agrees with the results of particle-in-cell simulations performed using the KARAT and OOPIC-Pro codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current-induced spin torque resonance of magnetic insulators affected by field-like spin-orbit torques and out-of-plane magnetizations

The spin-torque ferromagnetic resonance (ST-FMR) in a bilayer system consisting of a magnetic insulator such as Y{sub 3}Fe{sub 5}O{sub 12} and a normal metal with spin-orbit interaction such as Pt is addressed theoretically. We model the ST-FMR for all magnetization directions and in the presence of field-like spin-orbit torques based on the drift-diffusion spin model and quantum mechanical boundary conditions. ST-FMR experiments may expose crucial information about the spin-orbit coupling between currents and magnetization in the bilayers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Statistical analysis of the ion beam production in a self magnetically insulated diode

The paper presents the results of a study on shot to shot variation in energy density of an ion beam formed by a self-magnetically insulated diode with an explosive emission cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: plasma formation occurs during the first pulse (negative polarity, 300–500 ns, 100–150 kV), and ion extraction and acceleration during the second pulse (positive polarity, 150 ns, 250–300 kV). Crucially, it was found that the standard deviation of energy density does not exceed 11%, whilst the same variation for ion current density was 20%–30%, suggesting the presence of neutrals in the beam. This idea is further supported by the fact that ion current density is only weakly dependant on the accelerating voltage and other output parameters of the accelerator (coefficient of determination < 0.3), whilst the correlation between the energy density of the beam and the output parameters is strong (coefficient of determination > 0.9). We attribute the neutral component as being due to charge exchange between accelerated ions and neutral molecules from a neutral layer near the anode surface. Implementation using a self-magnetically insulated diode with an explosive-emission cathode, having an operational lifetime of up to 10{sup 7} shots, has promising prospects for various technological applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scaled-down particle-in-cell simulation of cathode plasma expansion in magnetically insulated coaxial diode

The expansion of cathode plasma in magnetically insulated coaxial diode (MICD) is investigated in theory and particle-in-cell (PIC) simulation. The temperature and density of the cathode plasma are about several eV and 10{sup 13}–10{sup 16 }cm{sup −3}, respectively, and its expansion velocity is of the level of few cm/μs. Through hydrodynamic theory analysis, expressions of expansion velocities in axial and radial directions are obtained. The characteristics of cathode plasma expansion have been simulated through scaled-down PIC models. Simulation results indicate that the expansion velocity is dominated by the ratio of plasma density other than the static electric field. The electric field counteracts the plasma expansion reverse of it. The axial guiding magnetic field only reduces the radial transport coefficients by a correction factor, but not the axial ones. Both the outward and inward radial expansions of a MICD are suppressed by the much stronger guiding magnetic field and even cease.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion beam enhancement in magnetically insulated ion diodes for high-intensity pulsed ion beam generation in non-relativistic mode

High-intensity pulsed ion beam (HIPIB) with ion current density above Child-Langmuir limit is achieved by extracting ion beam from anode plasma of ion diodes with suppressing electron flow under magnetic field insulation. It was theoretically estimated that with increasing the magnetic field, a maximal value of ion current density may reach nearly 3 times that of Child-Langmuir limit in a non-relativistic mode and close to 6 times in a highly relativistic mode. In this study, the behavior of ion beam enhancement by magnetic insulation is systematically investigated in three types of magnetically insulated ion diodes (MIDs) with passive anode, taking into account the anode plasma generation process on the anode surface. A maximal enhancement factor higher than 6 over the Child-Langmuir limit can be obtained in the non-relativistic mode with accelerating voltage of 200–300 kV. The MIDs differ in two anode plasma formation mechanisms, i.e., surface flashover of a dielectric coating on the anode and explosive emission of electrons from the anode, as well as in two insulation modes of external-magnetic field and self-magnetic field with either non-closed or closed drift of electrons in the anode-cathode (A-K) gap, respectively. Combined with ion current density measurement, energy density characterization is employed to resolve the spatial distribution of energy density before focusing for exploring the ion beam generation process. Consistent results are obtained on three types of MIDs concerning control of neutralizing electron flows for the space charge of ions where the high ion beam enhancement is determined by effective electron neutralization in the A-K gap, while the HIPIB composition of different ion species downstream from the diode may be considerably affected by the ion beam neutralization during propagation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical investigation of the fundamental mode frequency of the magnetically insulated transmission line oscillator

The fundamental mode frequency of a magnetically insulated transmission line oscillator is investigated theoretically by the equivalent circuit method, and an exact theoretical formula about the fundamental mode frequency is given. The theoretical results are compared with the simulation and experimental results, which shows that the relative error, which is calculated according to the theoretical and simulation frequencies, is less than 3%, so the validity of the theoretical formula is verified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proposal of a gigawatt-class L/Ku dual-band magnetically insulated transmission line oscillator

We present a gigawatt (GW)-class magnetically insulated transmission line oscillator (MILO) which is capable of generating dual-band high power microwaves (HPMs). The proposed device, deriving from previously studied complex MILO and dual-frequency MILO, is designed to produce two HPMs in L-band and Ku-band, respectively. It is found in particle-in-cell (PIC) simulation that when the diode voltage is 610 kV, HPMs with frequencies of 1.72 GHz and 14.6 GHz can be achieved with powers of 3.3 GW and 2.4 GW, respectively. The corresponding total power conversion efficiency is approximately 12.8%. Power difference of the two generated HPMs is approximately 1.4 dB, and frequency difference of them reaches a level as high as ∼10 dB.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Distribution of leakage currents in the cylindrical and conical sections of the magnetically insulated transmission line of the Angara-5-1 facility in experiments with wire arrays

Current leakages in the magnetically insulated transmission lines (MITL) impose restrictions on the transmission of electromagnetic pulses to the load in high-power electrophysical facilities. The multimodule Angara-5-1 facility with an output electric power of up to 6 TW is considered. In this work, the experimental and calculated profiles of leakage currents in two sections of the line are compared when the eight-module facility is loaded by a wire array. The azimuthal distribution of the current in the cylindrical section of the MITL is also considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proposal of a novel compact P-band magnetically insulated transmission line oscillator with inclined vanes

In this paper, we present a novel compact P-band magnetically insulated transmission line oscillator (MILO) with specially inclined slow-wave-structure (SWS) vanes to decrease its total dimension and weight. The dispersion characteristics of the inclined SWS are investigated in detail and made comparisons with that of the traditional straight SWS. The results show that the inclined SWS is more advantageous in operating on a steady frequency in a wide voltage range and has a better asymmetric mode segregation and a relatively large band-gap between the TM{sub 00} and TM{sub 01} modes which are in favor of avoiding the asymmetric and transverse mode competition. Besides, the transverse dimension of the proposed novel inclined SWS with the same operation frequency is decreased by about 50%, and correspondingly the device volume shrinks remarkably to its 0.35 times. In particle-in-cell simulation, the electron bunching spokes are obviously formed in the inclined SWS, and a P-band high-power microwave with a power of 5.8 GW, frequency of 645 MHz, and efficiency of 17.2% is generated by the proposed device, which indicates the feasibility of the compact design with the inclined vanes at the P-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a Process to Build Polyimide Insulated Magnets For Operation at 350C

An extensive R&D program has been conducted that has confirmed the feasibility of designing and fabricating copper alloy magnets that can successfully operate at temperatures as high as 350C. The process, originally developed for the possibility of manufacturing in-vessel resonant magnetic field perturbation (RMP) coils for JET, has been optimized for insulated magnet (and, potentially, other high temperature component) applications. One of the benefits of high temperature operation is that active cooling may no longer be required, greatly simplifying magnet/component design. These elevated temperatures are beyond the safe operating limits of conventional OFHC copper and the epoxies that bond and insulate the turns of typical magnets. This would necessitate the use an alternative copper alloy conductor such as C18150 (CuCrZr). Coil manufacture with polyimide is very similar to conventional epoxy bonded coils. Conductors would be dry wound then impregnated with polyimide of low enough viscosity to permit saturation, then cured; similar to the vacuum pressure impregnation process used for conventional epoxy bonded coils. Representative polyimide insulated coils were mechanically tested at both room temperature and 350C. Mechanical tests included turn-to-turn shear bond strength and overall polyimide adhesion strength, as well as the flexural strength of a 48-turn polyimide-bonded coil bundle. This paper will detail the results of the testing program on coil samples. These results demonstrate mechanical properties as good, or better than epoxy bonded magnets, even at 350C.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An improved X-band magnetically insulated transmission line oscillator

This paper presents an improved X-band magnetically insulated transmission line oscillator (MILO) design that addresses several deficiencies found in previous experiments. In the new structure, an improved design of the launch point region is introduced, which improves the electric field uniformity on the cathode surface in order to suppress cathode flare formation. In addition, a new design for the load region is presented where the end of the cathode consists of four polymer velvet rings, a mesh is adopted as the anode of the load, and a metal barrel is employed as the beam dump. These improvements reduce energy deposition in the beam dump to less than 30 J/g, which probably suppresses plasma formation in the load region. Typical simulation results of the improved MILO show that when the applied voltage is 690 kV and beam current is 48 kA, high power microwave with an average power of 3.5 GW and a frequency of 9.26 GHz is generated. Furthermore, new meshes are specially studied for long pulse operation of this improved X-band MILO. Correlative experiments are being carried out in our laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of a high impedance magnetically insulated transmission line oscillator with hollow load

A novel high-impedance magnetically insulated transmission line oscillator (MILO) with greatly restrained power deposition on the anode has been investigated. Methods to increase the MILO impedance and decrease the anode current are discussed. A MILO with impedance of 30 {Omega} and power conversion efficiency of 25% is presented by particle-in-cell simulations. Compared with the previous MILO in our lab, the anode current of the proposed MILO is reduced about 50%, the power conversion efficiency doubles, and the power deposition on anode is reduced nearly one half. Furthermore, considerations for reducing the power deposition on load have also been carried out in MILO design, and the load current is reduced to 4.6 kA, only 17% of the total anode current. Finally, a hollow load was introduced to reduce the power deposition density on the load, without decreasing the power conversion efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for improved voltage determination for pulsed power systems utilizing a magnetically insulated transmission line

Because the voltage is difficult to measure in a magnetically insulated transmission line (MITL), measurement of the currents flowing in the cathode and anode are often used with MITL theory to estimate the voltage in a given experiment. However, that estimate contains a space charge correction term whose magnitude depends on what is referred to as the g factor that describes the distribution of charge and current in the electron flow layer in the MITL. Typically, g is on the order of unity but the accuracy of the voltage estimate depends on its actual value. While the space charge correction term is small when the MITL flow is strongly insulated, it is particularly important near self-limited MITL flow. System parameters that affect the distribution of electron flow are studied here at self-limited flow in order to illustrate this matter and develop a methodology to improve the voltage determination.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a colinear Second-Harmonic Orthogonal Polarization (SHOP) interferometer for electron areal density measurements in Magnetically Insulated Transmission Lines (MITLs)

Experimental measurements of low density plasmas forming in Magnetically Insulated Transmission Line (MITL) regions are desired to improve our understanding of current loss and power flow. Therefore, a new optical interferometer diagnostic was commissioned via this LDRD project. To measure the expected 10 13 - 10 17 cm -3 electron densities inside the 0.5 - 6 mm Anode-Cathode (A-K) gaps, a colinear SHOP interferometer diagnostic was constructed. The diagnostic was initially fielded on the University of New Mexico (UNM) Helicon-Cathode (HelCat) plasma device which provided a highly repeatable and well understood plasma source for which the colinear SHOP interferometer’s functionality could be verified and measured. Utilizing the highly repeatable plasma source and shot averaging, the interferometer was able to achieve an areal density sensitivity of 1×10 14 cm -2 . This work at UNM lead to a Review of Scientific Instruments (RSI) publication [20], DOI:10.1063/5.0101687. After the diagnostic’s capability was proven at UNM, the colinear SHOP interferometer was commissioned for use on the Sandia National Laboratories (SNL) Mykonos accelerator. Here, it provided the first temporal areal density measurements of plasma formation in a parallel plate MITL. The diagnostic was able to achieve a single shot (no multi-shot averaging like at UNM) areal density sensitivity of 1×10 15 cm -2 along a ~ 2mm probing path length, which provided adequate capability to conduct fundamental physics research of MITL plasma formation. CHICAGO and ALEGRA simulations support the diagnostics experimental findings. More experimental and computational work will continue, likely leading to another publication(s). The smaller scale Mykonos accelerator work has also provided justification that the colinear SHOP interferometer is a capable diagnostic for measuring plasma areal densities in the inner MITL and convolute regions of larger TW-class accelerators like SNL’s Z machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dirty-boson physics with magnetic insulators

We report on recent theoretical and experimental efforts aimed at the investigation of the physics of interacting disordered bosons (so-called dirty bosons) in the context of quantum magnetism. The physics of dirty bosons is relevant to a wide variety of condensed matter systems, encompassing helium in porous media, granular superconductors, and ultracold atoms in disordered optical potentials, to cite a few. Nevertheless, the understanding of the transition from a localized, Bose-glass phase to an ordered, superfluid condensate phase still represents a fundamentally open problem. Still to be constructed is also a quantitative description of the highly inhomogeneous and strongly correlated phases connected by the transition. We observe how disordered magnetic insulators in a strong magnetic field can provide a well-controlled realization of the above transition. Combining numerical simulations with experiments on real materials can demonstrate some fundamental properties of the critical behavior, such as the scaling of the critical temperature to condensation close to the quantum critical point.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗