Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lockwood”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Diol isomer revealed as a source of methyl ketene from propionic acid unimolecular decomposition

Carboxylic acids are important combustion intermediates, especially regarding the combustion of oxygenates such as ethyl esters. The purpose of this study is to discern the unimolecular decomposition pathways of one such carboxylic acid, propionic acid, using microreactor flow experiments with line-tunable photoionization mass spectrometry and infrared spectroscopy, along with high-level electronic structure calculations (CCSD(T)/cc-pV∞Z//M06-2X/cc-pVTZ level of theory) and master equation theory. Here, microreactor experiments were performed at 300–1500 K, pressures decreasing from roughly 300 Torr to vacuum pressure, and around 100 μs residence times. Primary products are methyl ketene, ketene, ethylene, and methyl radical. Theory suggests the two lowest energy bond fissions are active at these conditions and responsible for the production of ketene, methyl radical, and some ethylene. Importantly, theory revealed the significance of the isomerization of propionic acid to propene-1,1-diol, and the subsequent dehydrogenation reaction of the diol as an alternative explanation for the unimolecular formation of methyl ketene. This is predicted to be the dominant thermal decomposition pathway at lower temperatures (up to ~850 K). Line-tunable VUV photons allowed for isomer resolution of the products and showed no evidence of the diol of propionic acid surviving until detection, suggesting propene-1,1-diol decomposes either to methyl ketene and water rapidly, fragments upon ionization to a distonic ion inseparable from methyl ketene through our detection methods, or never stabilizes as propionic acid well-skips directly to methyl ketene. Infrared spectroscopy showed no evidence of the decarboxylation of propionic acid at these conditions. Updated rate constants and branching ratios for propionic acid decomposition are calculated and provided for future modeling studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overall and cause‐specific mortality in the Sentinel system: A power analysis

Abstract Purpose Mortality data within the Sentinel Death Tables remain generally uncharacterized. Assessment of mortality data within Sentinel will help inform its utility for medical product safety studies. Methods To determine if Sentinel contains sufficient all‐cause and cause‐specific mortality events to power postmarketing safety studies. We calculated crude rates of all‐cause mortality and suicide and proportional mortality from suicide from 2004 to 2012 in seven Sentinel data partners. Results were stratified by data partner, sex, age group, and calendar year and compared with national estimates from Centers for Disease Control and Prevention Wide‐ranging ONline Data for Epidemiologic Research. We performed sample size estimations for all‐cause mortality and 10 leading causes of death. Results We observed 479 694 deaths, including 5811 suicides, during 68 million person‐years of follow‐up. Pooled mean death and suicide rates in the data partners were 710 and 8.6 per 100 000 person‐years, respectively (vs 810 and 11.8 nationally). The mean proportional mortality from suicide among the data partners was 1.2%, compared with 1.5% nationally. National trends of decreasing overall mortality and increasing proportional mortality for suicide were reflected within Sentinel. We estimated that detecting hazard ratios of 1.25 and 3 would require 16 442 and 460 exposed patients, respectively, for overall mortality, and 1.3 million and 37 411, respectively, for suicide. Conclusions This was the first study to investigate mortality data in the Sentinel death tables. We found that all‐cause mortality appeared well powered for use as a safety outcome and cause‐specific mortality outcomes may be adequately powered in certain circumstances. Further investigation into the quality of the Sentinel death data is needed.

Swain, Richard S.↗

A Quantitative Approach to Architecting All-Flash Lustre File Systems

New experimental and AI-driven workloads are moving into the realm of extreme-scale HPC systems at the same time that high-performance flash is becoming cost-effective to deploy at scale. This confluence poses a number of new technical and economic challenges and opportunities in designing the next generation of HPC storage and I/O subsystems to achieve the right balance of bandwidth, latency, endurance, and cost. In this work, we present quantitative models that use workload data from existing, disk-based file systems to project the architectural requirements of all-flash Lustre file systems. Using data from NERSC’s Cori I/O subsystem, we then demonstrate the minimum required capacity for data, capacity for metadata and data-on-MDT, and SSD endurance for a future all-flash Lustre file system.

Lockwood, GK↗

Understanding fundamental effects of biofuel structure on ignition and physical fuel properties

The development of biochemicals and biofuels with advantaged properties of higher combustion efficiency at lower emission levels can be aided by a priori prediction of critical global characteristics based on molecular structure. Existing predictive techniques are incomplete for comprehensive ignition and physical fuel property prediction. Here this investigation focuses on filling this knowledge gap by developing a priori prediction techniques for predicting important ignition as well as physical fuel properties of promising advantaged biofuels. We demonstrate the utility of this a priori prediction technique on saturated (≤C 5 ) alcohols, both linear and branched in nature by correlating their molecular structure with both important ignition and physical properties of the fuels. This work utilizes a semi-automated method of predicting ignition characteristics via accurate fundamental-based calculations of the fuel radical cascades that govern low-temperature combustion. This numerical methodology is supported by the relevant fuel ignition delay time (IDT) and research octane number (RON) data experimentally measured by the Advanced Fuel Ignition Delay Analyzer (AFIDA). Phyiscal fuel property trends are also analyzed by correlating the molecular structure of the fuel to its physical characteristics. Based on their molecular structure, recommendations are made on an a priori method for selecting biofuels that have advantaged properties for the selected fuel application. Lastly, the utility of this investigation is extended beyond the subset of alcohols considered by analyzing the IDT trends of i-Pentanol and n-Hexanol, revealing the fidelity of the novel kinetic modelling approach and the accuracy of the predicted trends in this study.

09 BIOMASS FUELS↗

PSA Kinetics and PSA Bounce Following Permanent Seed Prostate Brachytherapy

Purpose: To report the incidence, timing, and magnitude of the benign prostate-specific antigen (PSA) bounce after {sup 125}I prostate brachytherapy and correlate the bounce with clinical and/or dosimetric factors. Methods and Materials: From March 1999 to August 2003, a total of 292 men received {sup 125}I prostate brachytherapy without androgen deprivation or supplemental beam radiotherapy and have PSA follow-up >30 months. Implants were preplanned using transrectal ultrasound (TRUS) and performed under transrectal ultrasound/fluoroscopy guidance using preloaded needles. A PSA bounce is defined as an increase {>=}0.2 ng/ml with spontaneous return to prebounce level or lower. Results: Resolved PSA bounces were seen in 40% of men with follow-up >30 months. Median onset was 15 months, and median magnitude was 0.76 ng/ml. Magnitude >2 ng/ml was seen in 15%. The only clinical or dosimetric factor predictive of bounce in multivariate analysis was younger age. Median time to increasing PSA level indicative of failure was 30 months. Conclusions: Benign PSA bounces are common after {sup 125}I prostate brachytherapy, especially in younger men. An increase >2 ng/ml above the nadir was seen in 15%. Magnitude of increase does not distinguish bounce from failure. Time to the start of the PSA increase can be helpful, but is not absolute. The PSA bounce does not predict subsequent failure. Caution is advised in interpreting an early increasing PSA level in the first 30 months after {sup 125}I brachytherapy in favorable-risk patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Localization of Recurrent Prostate Cancer After External Beam Radiotherapy

Purpose: To compare the performance of T2-weighted (T2w) imaging and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the prostate gland in the localization of recurrent prostate cancer in patients with biochemical failure after external beam radiotherapy (EBRT). Methods and Materials: T2-weighted imaging and DCE MRI were performed in 33 patients with suspected relapse after EBRT. Dynamic contrast-enhanced MRI was performed with a temporal resolution of 95 s. Voxels enhancing at 46 s after injection to a greater degree than the mean signal intensity of the prostate at 618 s were considered malignant. Results from MRI were correlated with biopsies from six regions in the peripheral zone (PZ) (base, mid, and apex). The percentage of biopsy core positive for malignancy from each region was correlated with the maximum diameter of the tumor on DCE MRI with a linear regression model. Results: On a sextant basis, DCE MRI had significantly better sensitivity (72% [21of 29] vs. 38% [11 of 29]), positive predictive value (46% [21 of 46] vs. 24% [11 of 45]) and negative predictive value (95% [144 of 152] vs. 88% [135 of 153] than T2w imaging. Specificities were high for both DCE MRI and T2w imaging (85% [144 of 169] vs. 80% [135 of 169]). There was a linear relationship between tumor diameters on DCE MRI and the percentage of cancer tissue in the corresponding biopsy core (r = 0.9, p < 0.001), with a slope of 1.2. Conclusions: Dynamic contrast-enhanced MRI performs better than T2w imaging in the detection and localization of prostate cancer in the peripheral zone after EBRT. This may be helpful in the planning of salvage therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter- and Intrafractional Tumor and Organ Movement in Patients With Cervical Cancer Undergoing Radiotherapy: A Cinematic-MRI Point-of-Interest Study

Purpose: Internal tumor and organ movement is important when considering intensity-modulated radiotherapy for patients with cancer of the cervix because of the tight margins and steep dose gradients. In this study, the internal movement of the tumor, cervix, and uterus were examined using serial cinematic magnetic resonance imaging scans and point-of-interest analysis. Methods and Materials: Twenty patients with Stage IB-IVA cervical cancer underwent pelvic magnetic resonance imaging before treatment and then weekly during external beam radiotherapy. In each 30-min session, sequential T{sub 2}-sagittal magnetic resonance imaging scans were obtained. The points of interest (cervical os, uterine canal, and uterine fundus) were traced on each image frame, allowing the craniocaudal and anteroposterior displacements to be measured. The mean displacements and trends were analyzed using mixed linear models. Prediction intervals were calculated to determine the internal target margins. Results: Large interscan motion was found for all three points of interest that was only partially explained by the variations in bladder and rectal filling. The intrascan motion was much smaller. Both inter- and intrascan motion was greatest at the fundus of the uterus, less along the canal, and least at the cervical os. The isotropic internal target margins required to encompass 90% of the interscan motion were 4 cm at the fundus and 1.5 cm at the os. In contrast, smaller margins of 1 cm and 0.45 cm, respectively, were adequate to encompass the intrascan motion alone. Conclusion: Daily soft-tissue imaging with correction for interfractional motion or adaptive replanning will be important if the benefits of intensity-modulated radiotherapy are to be maximized in women with cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Concurrent High-Dose Cisplatin Chemotherapy and Conformal Radiotherapy on Cervical Esophageal Cancer Survival

Purpose: To determine whether a change in treatment policy to conformal, elective nodal radiotherapy and concurrent high-dose cisplatin improved survival for cervical esophageal cancer patients. Methods and Materials: All cervical esophageal cancer patients treated between 1997 and 2005 were restaged (1983 American Joint Committee on Cancer criteria). Patients treated before 2001 (previous cohort [PC]) were compared with those treated from 2001 onward (recent cohort [RC]). The PC institutional chemoradiotherapy protocol was 54 Gy in 20 fractions within 4 weeks, with 5-fluorouracil (1,000 mg/m{sup 2}) on Days 1-4 and either mitomycin C (10 mg/m{sup 2}) or cisplatin (75 mg/m{sup 2}) on Day 1. The RC institutional chemoradiotherapy protocol was conformal radiotherapy, 70 Gy in 35 fractions within 7 weeks, to the primary tumor and elective nodes, with high-dose cisplatin (100 mg/m{sup 2}) on Days 1, 22, and 43. Results: The median follow-up was 3.1 years (PC, 8.1 and RC, 2.3). Of 71 patients (25 women and 46 men), 21 of 29 in the PC and 29 of 42 in the RC were treated curatively (curative subgroup, n = 50). Between the two groups, no differences in overall survival or locoregional relapse-free survival were seen. The overall survival rate at 2 and 5 years was 35% (range, 24-47%) and 21% (range, 12-32%) in the whole group and 46% (range 32-60%) and 28% (range, 15-42%) in the curative group, respectively. In the curative group, no statistically significant prognostic factors were found. Trends toward better locoregional relapse-free survival were seen in women (2-year rate, 73% vs. for men, 36%; p = 0.08) and in patients aged >64 years (2-year rate, 68% vs. age {<=}64 years, 34%; p = 0.10). Conclusion: No survival improvement could be demonstrated after changing the treatment policy to high-dose cisplatin-based, conventionally fractionated conformal chemoradiotherapy. Female gender and older age might predict for better outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Supervised Automated Algorithm for Fast Quantitative Evaluation of Organ Motion on Magnetic Resonance Imaging

Purpose: To validate a correlation coefficient template-matching algorithm applied to the supervised automated quantification of abdominal-pelvic organ motion captured on time-resolved magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 21 patients across four anatomic sites were analyzed. Representative anatomic points of interest were chosen as surrogates for organ motion. The point of interest displacements across each image frame relative to baseline were quantified manually and through the use of a template-matching software tool, termed 'Motiontrack.' Automated and manually acquired displacement measures, as well as the standard deviation of intrafraction motion, were compared for each image frame and for each patient. Results: Discrepancies between the automated and manual displacements of {>=}2 mm were uncommon, ranging in frequency of 0-9.7% (liver and prostate, respectively). The standard deviations of intrafraction motion measured with each method correlated highly (r = 0.99). Considerable interpatient variability in organ motion was demonstrated by a wide range of standard deviations in the liver (1.4-7.5 mm), uterus (1.1-8.4 mm), and prostate gland (0.8-2.7 mm). The automated algorithm performed successfully in all patients but 1 and substantially improved efficiency compared with manual quantification techniques (5 min vs. 60-90 min). Conclusion: Supervised automated quantification of organ motion captured on magnetic resonance imaging using a correlation coefficient template-matching algorithm was efficient, accurate, and may play an important role in off-line adaptive approaches to intrafraction motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Motion of Liver Tumors Using Cine-Magnetic Resonance Imaging

Purpose: To measure the three-dimensional motion of liver tumors using cine-magnetic resonance imaging (MRI) and compare it to the liver motion assessed using fluoroscopy. Methods and Materials: Liver and liver tumor motion were investigated in the first 36 patients with primary (n = 20) and metastatic (n = 16) liver cancer accrued to our Phase I stereotactic radiotherapy study. At simulation, all patients underwent anteroposterior fluoroscopy, and the maximal diaphragm excursion in the craniocaudal (CC) direction was observed. Cine-MRI using T{sub 2}-weighted single shot fast spin echo sequences were acquired in three orthogonal planes during free breathing through the centroid of the most dominant liver tumor. ImageJ software was used to measure the maximal motion of the tumor edges in each plane. The intra- and interobserver reproducibility was also quantified. Results: The average CC motion of the liver at fluoroscopy was 15 mm (range, 5-41). On cine-MRI, the average CC tumor motion was 15.5 mm (range, 6.9-35.4), the anteroposterior motion was 10 mm (range, 3.7-21.6), and the mediolateral motion was 7.5 mm (range, 3.8-14.8). The fluoroscopic CC diaphragm motion did not correlate well with the MRI CC tumor motion (r = 0.25). The mean intraobserver error was <2 mm in the CC, anteroposterior, and mediolateral directions, and 90% of measurements between observers were within 3 mm. Conclusions: The results of our study have shown that cine-MRI can be used to directly assess liver tumor motion in three dimensions. Tumor motion did not correlate well with the diaphragm motion measured using kilovoltage fluoroscopy. The tumor motion data from cine-MRI can be used to facilitate individualized planning target volume margins to account for breathing motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Final Report of Multicenter Canadian Phase III Randomized Trial of 3 Versus 8 Months of Neoadjuvant Androgen Deprivation Therapy Before Conventional-Dose Radiotherapy for Clinically Localized Prostate Cancer

Purpose: To evaluate the effect of 3 vs. 8 months of neoadjuvant hormonal therapy before conventional-dose radiotherapy (RT) on disease-free survival for localized prostate cancer. Methods and Materials: Between February 1995 and June 2001, 378 men were randomized to either 3 or 8 months of flutamide and goserelin before 66 Gy RT at four participating centers. The median baseline prostate-specific antigen level was 9.7 ng/mL (range, 1.3-189). Of the 378 men, 26% had low-, 43% intermediate-, and 31% high-risk disease. The two arms were balanced in terms of age, Gleason score, clinical T category, risk group, and presenting prostate-specific antigen level. The median follow-up for living patients was 6.6 years (range, 1.6-10.1). Of the 378 patients, 361 were evaluable, and 290 were still living. Results: The 5-year actuarial freedom from failure rate for the 3- vs. 8-month arms was 72% vs. 75%, respectively (p = 0.18). No difference was found in the failure types between the two arms. The median prostate-specific antigen level at the last follow-up visit for patients without treatment failure was 0.6 ng/mL in the 3-month arm vs. 0.50 ng/mL in the 8-month arm. The disease-free survival rate at 5 years was improved for the high-risk patients in the 8-month arm (71% vs. 42%, p = 0.01). Conclusion: A longer period of NHT before standard-dose RT did not alter the patterns of failure when combined with 66-Gy RT. High-risk patients in the 8-month arm had significant improvement in the 5-year disease-free survival rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Truths and Myths About Radiotherapy for Verrucous Carcinoma of Larynx

Purpose: The role of primary radiotherapy (RT) for laryngeal verrucous carcinoma (LVC) is controversial because of concerns about anaplastic transformation, an increased incidence of metastases, and poorer local control after RT. To address these concerns, we report our experience. Methods and Materials: All patients with pathologically diagnosed LVC treated with primary RT at our institution between 1961 and 2004 were reviewed. The local control, overall survival, and disease-specific survival rate were established. The outcome after salvage treatment and the incidence of metastases and anaplastic transformation were determined. Results: Of 62 LVC patients with a minimal follow-up of 2 years, 20 local and 1 nodal recurrence were identified. Salvage surgery was undertaken in 18 of the 21 patients, and disease control was achieved in 17; the eighteenth patient died of a complication after surgery. Ultimate laryngeal preservation was achieved in 50 patients (81%), including 42 after initial RT and an additional 8 after salvage surgery. Distant failure and anaplastic transformation were not observed. Second cancers after RT were identified in 4 patients, only 1 of which was a head-and-neck cancer detected 11 years later. Of the 39 deceased patients, only 3 died of LVC. The local control, overall survival, and disease-specific survival rate at 5 years was 66% (95% confidence interval, 52-77%), 87% (95% confidence interval, 75-93%), and 97% (95% confidence interval, 87-99%), respectively. Conclusion: The results of our study have shown that the initial control of LVC with RT is less reliable compared with reports from surgical series; however, local recurrence was almost always salvaged successfully, resulting in disease-specific survival rates equivalent to those of surgical series. Neither anaplastic transformation nor unusual metastasis development was observed in this series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Local Tumor Response to Fractionated Radiation Therapy for Non-Hodgkin Lymphoma Using Weekly {sup 18}F-FDG PET/CT Imaging

Purpose: To quantify, in a feasibility study, metabolic and volumetric response to fractionated radiation therapy (RT) using weekly {sup 18}F fluoro-deoxyglucose positron emission tomography (PET) imaging for 10 non-Hodgkin lymphoma (NHL) patients, and to correlate them to clinical outcome. Methods and Materials: Ten patients with chemotherapy-refractory NHL planned for radical RT were prospectively entered into a research study. PET/computed tomography (CT) scans were acquired before RT, and repeated weekly during the 3- to 4-week course of RT, and at 1 and 3 months after therapy. Gross tumor volumes were contoured on CT scans and the corresponding maximum standardized uptake values (SUV{sub max}) determined in the coregistered PET images. The clinical outcomes of interest were local tumor response at 3 months post-RT and local tumor status at last follow-up or time of death. Results: {sup 18}F fluoro-deoxyglucose uptake from inflammation was rarely observed. The responses showed a large variability between patients. SUV{sub max} decreased consistently with a median of -2.1% per Gy (range, -3.3 to -0.7) and the median of the volumetric response was -2.2% per Gy (range, -2.8 to +0.5). Initial SUV{sub max} was not correlated with local control, whereas smaller initial tumor volume was, with smaller tumors more likely to achieve local control. The responses after treatment were also correlated to local control, but not the responses during treatment. Conclusions: Radiation does not confound the FDG uptake in the NHL tumor and normal tissues. Only smaller initial tumor volume and metabolic and volumetric response after completion of radiation therapy significantly correlated with eventual local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Stereotactic Target Localization Using 3-Tesla MRI for Radiosurgery Planning

Purpose: Increasing the magnetic resonance imaging (MRI) field strength can improve image resolution and quality, but concerns remain regarding the influence on geometric fidelity. The objectives of the present study were to spatially investigate the effect of 3-Tesla (3T) MRI on clinical target localization for stereotactic radiosurgery. Methods and Materials: A total of 39 patients were enrolled in a research ethics board-approved prospective clinical trial. Imaging (1.5T and 3T MRI and computed tomography) was performed after stereotactic frame placement. Stereotactic target localization at 1.5T vs. 3T was retrospectively analyzed in a representative cohort of patients with tumor (n = 4) and functional (n = 5) radiosurgical targets. The spatial congruency of the tumor gross target volumes was determined by the mean discrepancy between the average gross target volume surfaces at 1.5T and 3T. Reproducibility was assessed by the displacement from an averaged surface and volume congruency. Spatial congruency and the reproducibility of functional radiosurgical targets was determined by comparing the mean and standard deviation of the isocenter coordinates. Results: Overall, the mean absolute discrepancy across all patients was 0.67 mm (95% confidence interval, 0.51-0.83), significantly <1 mm (p < .010). No differences were found in the overall interuser target volume congruence (mean, 84% for 1.5T vs. 84% for 3T, p > .4), and the gross target volume surface mean displacements were similar within and between users. The overall average isocenter coordinate discrepancy for the functional targets at 1.5T and 3T was 0.33 mm (95% confidence interval, 0.20-0.48), with no patient-specific differences between the mean values (p >.2) or standard deviations (p >.1). Conclusion: Our results have provided clinically relevant evidence supporting the spatial validity of 3T MRI for use in stereotactic radiosurgery under the imaging conditions used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction and Respiratory Organ Motion During Conformal Radiotherapy in Gastric Cancer

Purpose: To quantify the interfraction and breathing organ motion during adjuvant radiotherapy for gastric cancer and assess organ stability in different breathing states. Methods and Materials: A planning computed tomography (CT) scan and serial study CT scans in free breathing, voluntary inhale and exhale were performed in weeks 1, 3, and 5 of radiotherapy for 22 resected gastric patients. All data sets were fused to register the vertebral bodies. The regions of interest (kidneys, stomach, liver, pancreas, celiac axis, and porta hepatis) or points of interest (POIs; left dome of diaphragm, splenic hilum) were identified. For each region of interest, a POI was automatically placed at the center of mass. The interfraction displacement and breathing amplitude were assessed in the craniocaudal (CC), anteroposterior (AP), and right-left (RL) directions. Results: Comparison of the serial free-breathing CT scans with the planning CT scan showed a median displacement of all POIs of 5.6, 2.2, and 1.8 mm in the CC, AP, and RL directions, respectively. Comparison of the serial inhale scans with the first inhale scan showed a displacement of 4.9, 2.6, and 1.8 mm in the CC, AP, and RL directions, respectively. The comparable values for the exhale scans were 5.1, 2.0, and 1.8 mm. The displacements of the organs were similar in the free breathing, inhale, and exhale states. The median respiratory amplitude in the CC, AP, and RL direction was 14, 4.8, and 1.7 mm, respectively. Conclusion: The median interfraction displacement of the POIs relative to the vertebral bodies was about 6 mm in the CC direction and 2 mm in the other directions. The planning target volume margins need to account for these shifts. Individual assessment of respiratory motion is recommended to identify patients with unusually large respiratory amplitude.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Cinematic Magnetic Resonance Imaging Study of Milk of Magnesia Laxative and an Antiflatulent Diet to Reduce Intrafraction Prostate Motion

Purpose: To determine the reduction of prostate motion during a typical radiotherapy (RT) fraction from a bowel regimen comprising an antiflatulent diet and daily milk of magnesia. Methods and Materials: Forty-two patients with T1c-T2c prostate cancer voided the bladder and rectum before three cinematic magnetic resonance imaging scans obtained every 9 s for 9 min in a vacuum immobilization device. The MRIs were at baseline without bowel regimen (MRI-BL), before CT planning with bowel regimen (MRI-CT), and before a randomly assigned RT fraction (1-42) with bowel regimen (MRI-RT). A single observer tracked displacement of the posterior midpoint (PM) of the prostate. The primary endpoints were comparisons of the proportion of time that the PM was displaced >3 mm (PTPM3) from its initial position, and the secondary endpoints were comparisons of the reduction of initial rectal area, with and without the bowel regimen. Results: The mean rectal area was: 13.5 cm{sup 2} at MRI-BL, 12.7 cm{sup 2} at MRI-CT, and 12.3 cm{sup 2} at MRI-RT (MRI-BL vs. MRI-CT, p = 0.11; MRI-BL vs. MRI-CT, p = 0.07). Moving rectal gas alone (56%) and moving gas and stool (18%) caused 74% of intrafraction prostate motion. The PTPM3 was 11.3% at MRI-BL, 4.8% at MRI-CT, and 12.0% at MRI-RT (MRI-BL vs. MRI-CT, p = 0.12; MRI-BL vs. MRI-RT, p = 0.89). Conclusion: For subjects voiding their rectum before imaging, an antiflatulent diet and milk of magnesia laxative did not significantly reduce initial rectal area or intrafraction prostate motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗