Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Load coordination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Technical Impacts of Light-Duty and Heavy-Duty Transportation Electrification on a Coordinated Transmission and Distribution System

In this study, we propose a strategy to model the required spatiotemporal charging demand from light-duty (LD) and medium- and heavy-duty (MHD) electric vehicles (EVs) using actual transportation data by mapping the demand for the required EV charging to a realistic and coordinated distribution and transmission electric grid at the predicted times of the day to study their impact on the power system in a variety of load, weather, and EV penetration scenarios. This work is the first study that includes the actual weather data and transportation data with realistic and coordinated distribution and transmission grid data in a large industry-scale level study. The main goal of this study is to identify possible issues and required upgrades in the electric grid, caused by an increase in EV integration. The transmission case study is a large grid with 6717 buses over a Texas footprint, and the distribution grid is over Houston, a city in Texas, covering over three million customers. The resulting overloads and voltage violations experienced in the system are discussed, and required planning upgrades to avoid these issues are suggested.

AC optimal power flow (AC-OPF)

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

TrustDER: Trusted, Private and Scalable Coordination of Distributed Energy Resources

In this project, the Stanford and SLAC Teams have developed a Trusted, Private and Scalable platform for coordinating Coordination of Distributed Energy Resources (TrustDER). This is a layered system that ensures private, trusted and scalable coordination and monitoring of DERs. It accommodates a variety of resources, such as solar generation, gensets and loads, with a particular focus on battery systems-based resources, as they are a transformational technology experiencing fast growth in adoption by large critical facilities. The platform can be used as standalone or added to existing aggregation systems to enable trust, privacy and resilience. TrustDER consists of layers that address each of the shortcomings of the existing state of the art. Each layer in the platform can operate independently but provides information to the layers above it to enable a novel form of overall coordination architecture. The project consists of several tasks, with each task dedicated to the design of each layer. Task 2 Resource Virtualization defined a software abstraction layer for distributed energy resources (DERs). The goal of this abstraction was to simplify the implementation of algorithms utilizing cooperation of DERs resources in a variety of use cases. Task 3 is on Secure ID for Asset Authentication. Identity Management Systems (IDMS) are a foundational infrastructure for interactions between entities (organizations, users, devices, and services). Secure ID is blockchain-based a distributed identity management system allowing (1) identity provisioning, (2) authentication, (3) authorization, and (4) identity data sharing for IoT-enabled assets on the electricity grid. In this project, the SLAC team focused on designing and testing Keymaker, a protocol for authenticating device identity managed by Secure ID. Task 5 Private and Safe Integration is focused on the design and evaluation of a DER cooperation scheme which allows for the aggregation of DERs without impacting network reliability. The approach is designed based on realistic assumptions regarding data availability, communication infrastructure limitations, and privacy. Task 6 Scalable Distributed Privacy for Information explored how virtualized batteries could be managed privately. Specifically, it examined the case in which a principal provides a partitioned battery to multiple clients. Task 7 Use Cases was to ensure that this technology was applied in relevant situations and scenarios. Primarily, this means that virtualization needed to be employed in a manner that either improved flexibility, bolstered security or privacy, or decreased costs.

25 ENERGY STORAGE

Dynamic Boundary Microgrids Under Privatization Considerations

Microgrids have physical, electrical, and logical (data, network, and ownership) boundaries. To power unserved customer loads during an outage, microgrids can extend the traditional operational boundaries. This can become complex when considering microgrid-to-microgrid (M2M) interactions where sensitive information such as competitive microgrid operational data is not shared. This work proposes an optimization method coordinated between microgrid controllers and distribution management systems that limits data sharing. The method involves a competitive bidding strategy that maximizes unserved load coverage while minimizing resource utilization and sensitive operational data sharing among entities. The work is validated on a two-microgrid system with photovoltaic and energy storage systems and curves of load derived from real world residential buildings datasets. Results show that the proposed method, when applied for three distinct use cases of energy storage sufficiency to cover the predefined boundary and/or the expanded boundary, can successfully select and bid the available load coverage.

Starke, Michael [ORNL] (ORCID:0000000221211195)

MegaWatt Mayhem: Grid Operator Challenges Center Loads

This report provides a summary of the challenges faced by United States electricity grid operators in accommodating and anticipating the rapid deployment of large loads, particularly data centers, based on academic literature and industry working groups. The report highlights the unique requirements and operational characteristics of data centers, which differ significantly from traditional industrial loads. Key issues addressed utility planning considerations, with emphasis on the implications for grid operators, impacts to normal operations for grid operators, reliability considerations during periods of grid stress, and resilience considerations for the changing operational paradigms based on data centers. Real-world examples are used to highlight these challenges and the changes that grid operators must address. The findings underscore the necessity for coordinated efforts and innovative solutions from both grid operators and regulatory bodies to ensure the stable integration of large loads into the grid. This report is the first in a series that will explore the challenges of data center deployments based on several key power system perspectives.

24 - POWER TRANSMISSION AND DISTRIBUTION

Resilience of the Electric Grid Through Trustable IoT-Coordinated Assets

The electricity grid has evolved from a physical system to a cyberphysical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) including renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. We propose a framework in this paper for achieving grid resilience through suitably coordinated assets including a network of Internet of Things devices. A local electricity market is proposed to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. With this SA, we show that a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. Multiple demonstrations are carried out using a high-fidelity cosimulation platform, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

distributed energy resources

Transformation of CeO 2 Nanoparticles into Atomically Dispersed Ce Cations Leads to Enhanced Reactivity for Automotive Emissions Control

Nanosized cerium oxide (CeO 2 ) has been extensively used as the oxygen storage component in automotive emission control systems. However, the possible influence of atomically dispersed Ce in these catalysts has not been recognized. Here, in this study, we demonstrate the controllable transformation of ceria nanoparticles into isolated cerium cations on γ-Al 2 O 3 via reductive atom trapping in 10% H 2 at 800 °C, achieving over half-monolayer coverage. Dispersed Ce 1 ions anchored by surface penta- and octa-coordinated Al sites exhibit outstanding thermal stability in air up to 500 °C, enabling further loading of active metals with well-defined catalyst structures. With this strategy, supported single-atom Rh 1 surrounded by dispersed Ce 1 is confirmed to exhibit much superior performance to Rh 1 on bare Al 2 O 3 or nanocrystalline CeO 2 in catalyzing NO reduction by CO, exhibiting a striking one-order-of-magnitude increase in activity. Dispersed Ce 1 exhibits greatly enhanced oxygen transfer capability compared to ceria nanoparticles and introduces a modified reaction mechanism that involves an adjacent Rh 1 –Ce 1 motif, resulting in a greatly decreased activation barrier (from 192 to 96 kJ/mol). The reactivity enhancements are also seen with Ce 1 -promoted Pt nanoparticles for oxidation of CO and hydrocarbons.

Jiang, Dong [Washington State Univ., Pullman, WA (

ASEAN Technical Exchange Workshop for System Operators, Regulators, and Policymakers

This presentation provides an in-depth exploration of power system planning, cross-border electricity trading, and battery energy storage systems (BESS), offering actionable insights for system operators, regulators, and policymakers. The first section delves into power system planning and analysis, focusing on capacity expansion models and resource adequacy studies, including their role in optimizing system efficiency, managing emissions, and addressing system reliability risks. Key considerations, such as integration of transmission into generation planning and the forecasting versus optimization of customer distributed energy resources (DER) technologies, are explored. The session highlights critical trade-offs in spatial granularity and model runtimes, as well as the feasibility of aligning distribution investments with capacity expansion efforts. The second section examines cross-border electricity trading, with an emphasis on resource adequacy concepts such as reliability targets, loss of load expectation (LOLE), and planning reserve margins (PRM). Case studies on reserve market design and coordination across US regions provide insights into improving reserve deliverability and managing interregional power balance and congestion. This section also addresses market-to-market congestion management, including advanced strategies for high-voltage direct current (HVDC) optimization and ancillary service delivery. Finally, the presentation covers the rapid evolution of Battery Energy Storage Systems (BESS), highlighting their operational growth, regulatory frameworks, and use cases in grid flexibility, energy storage, and reliability. The discussion focuses on the benefits of BESS for system stability, resilience, and integration of renewable energy, offering insights into its role as a vital component in the transition toward a more sustainable and flexible grid. Key performance parameters, such as throughput, round-trip efficiency, and state of charge, are also examined.

25 ENERGY STORAGE

Coordination of Energy Storage and Distributed Generation for Voltage Control and Peak-valley Filling

The increasing penetration of distributed energy resources (DERs) in distribution network (DN) poses challenges on voltage control. In addition, the growing integration of DERs also reshapes the traditional load profile. To comprehensively address the voltage control and peak-valley filling in DN, this paper proposes a model predictive control (MPC) based optimization framework. The proposed method can achieve coordinated voltage control and peak-valley filling by adjusting the reactive power output from distributed generations (DGs) and the charging/discharging of energy storage systems (ESS). The performance of the proposed method is demonstrated by simulations on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville

Nanomolar Sensitivity Chirality Transfer from Designed Helical Repeat Proteins to Achiral CdS Nanorods

Bridging chirality across length scales with inorganic− organic hybrid materials is a rapidly expanding area of research. Here, we establish asymmetry at CdS nanorod (NR) interfaces using a designed helical repeat protein bearing four cysteine residues (DHR- 4Cys). Hydrophobic NRs are transferred into water with glycine, and then glycine is displaced by DHR-4Cys, leveraging the thiophilicity of cadmium. Circular dichroism (CD) in the visible, coincident with CdS electronic transitions, reveals a chiral DHR-4Cys:CdS interface. Here, the dissymmetry factor [g-factor = 4.5 × 10 −4 (short NRs) and 5.0 × 10 −4 (long NRs)] is weakly dependent on the NR length, and CD persists at nanomolar protein loadings. Additionally, control experiments demonstrate that DHR-4Cys:CdS NR chirality is dictated by the local coordination of Cys with no significant contribution from the chiral secondary structure of the protein (g-factors of short and long Cys:CdS NRs are 4.8 × 10 −4 and 4.0 × 10 −4 , respectively). Together with far-UV CD and transmission electron microscopy, which provide evidence of preserved protein structure, these results provide the first demonstration that a structurally defined protein can induce chirality in CdS nanocrystals while maintaining protein structure at biologically relevant concentrations.

Cadmium sulfide

EUREICA: Efficient UltRa Endpoint IoT-enabled Coordinated Architecture

The electricity grid has evolved from a physical system to a cyber-physical system with digital devices that perform measurement, control, communication, computation, and actuation. The increased penetration of distributed energy resources (DERs) that include renewable generation, flexible loads, and storage provides extraordinary opportunities for improvements in efficiency and sustainability. However, they can introduce new vulnerabilities in the form of cyberattacks, which can cause significant challenges in ensuring grid resilience. The purpose of this project was to develop a framework ((Efficient, Ultra-REsilient, IoT-Coordinated Assets, or EUREICA)for achieving grid resilience through suitably coordinated assets including a network of Internet of Things (IoT) devices, and a local electricity market (LEM) to identify trustable assets and carry out this coordination. Situational Awareness (SA) of locally available DERs with the ability to inject power or reduce consumption is enabled by the market, together with a monitoring procedure for their trustability and commitment. Experiments conducted during this project demonstrated that, with this SA, a variety of cyberattacks can be mitigated using local trustable resources without stressing the bulk grid. The demonstrations were carried out using a variety of high-fidelity co-simulation platforms, real-time hardware-in-the-loop validation, and a utility-friendly simulator.

14 SOLAR ENERGY

Empirical Assessment of Interregional Coordination to Support Resource Adequacy [Slides]

This study examines where interregional transmission could most effectively support resource adequacy in the contiguous United States. We use hourly load, renewable generation, and real-time price data from 2016–2023 for 18 planning subregions to identify periods of elevated adequacy risk, defined as the top 100 annual hours of net load and wholesale prices in each region. We then measure the temporal coincidence of these peak periods between adjacent regions and compare price patterns to assess the potential for capacity sharing. Results show that NorthernGrid West, a winter-peaking region, has low coincidence of peak net load with its summer-peaking neighbors, indicating high potential for interregional support. In contrast, regions in the Northeast have highly coincident peak periods, suggesting limited adequacy benefits from additional transmission. Price-based analysis shows peak-hour differences in the Midwest and between ERCOT and neighboring regions, indicating potential economic benefits from increased transfers. The findings provide an empirical screening of where transmission may offer the greatest reliability benefits without adding new generation capacity.

24 POWER TRANSMISSION AND DISTRIBUTION

An unusual Co–S bond links B 12 chaperones in an interprotein complex

Chaperones in trafficking pathways ensure specificity of transition metal loading and protection against adventitious side reactions. In B 12 , an essential cofactor for humans, a cobalt ion is coordinated to a >1.3 kDa tetrapyrrolic scaffold, posing logistical challenges for its translocation. In this study, we report the 3.4 Å crystal structure of the human MMACHC and MMADHC B 12 chaperones, tethered via a rarely seen covalent cobalt–sulfur bond. B 12 is bound in the base-off state to MMACHC, with Cys-261 on MMADHC serving as the upper axial ligand; the lower-axial position is vacant. The propensity of thiolato-cobalamin derivatives bound to MMACHC to undergo spontaneous decomposition via general acid catalysis or reduction/oxidation chemistry is averted in the interprotein complex with MMADHC. An exposed face in the complex suggests an exit route for B 12 . No known clinical variants localize to the interprotein interface, consistent with the cobalt–sulfur bond being key to forming the high-affinity complex.

Science & Technology - Other Topics

Electrospun Ti–Zr Oxide Heterostructures Enable Strongly Anchored Ultralow-Ir Anodes for Durable Acidic Oxygen Evolution

Proton-exchange-membrane water electrolysis (PEMWE) requires acidic oxygen-evolution-reaction (OER) anodes that combine high activity, high durability, and low Ir loading. Here, we report a Ti-Zr composite electrospun oxide (ESO) nanorod support that enables ultralow-Ir anodes for high-performance PEMWE. Zr-containing Ti oxide heterostructures stabilize anatase-rich TiO2, tune the local oxygen-coordination environment, and strengthen interfacial anchoring of IrOx under acidic anodic conditions. The electrospun nanorod network further creates an open, mechanically coherent catalyst layer that improves Ir utilization, ionomer penetration, and mass transport. At an anode loading of 0.2 mgIr cm-2, the optimized Ir/TiZr20-ESO anode delivers a PEMWE mass activity of 0.99 A mgIr-1 at 1.45 V, 28.3 and 43.0 times higher than commercial Ir black and commercial IrO2/TiO2, respectively. The same anode reaches 3.0 and 4.0 A cm-2 at 1.75 and 1.83 V, respectively, and sustains 2000 h operation at 2.0 A cm-2. Also, accelerated stress tests up to 525 hours over 31,500 cycles confirm promising long-term durability, with an insignificant performance decay of 0.4 μV per cycle. Density functional theory indicates that the Ti-Zr oxide heterostructure suppresses Ti demetallation and strengthens IrO2 interfacial binding, rationalizing the improved high-current-density stability.

25 ENERGY STORAGE

Advancing Photo(Electro)Chemical Water Splitting: The Promise of Atomically Dispersed Single‐, Dual‐, and Alloy‐Site Catalysts

Single-atom catalysts (SACs) have rapidly gained prominence as an emerging class of electrocatalysts for water splitting, owing to their uniform and precisely defined active sites. By maintaining uniform reaction pathways, SACs minimize the formation of unwanted byproducts, thus exhibiting extremely high selectivity and atomic efficiency. A key determinant of SAC performance lies in the interfacial interaction between the isolated metal atoms and the supporting material under strong metal–support coordination, which is vital for maintaining long-term activity. However, despite these benefits, reproducibly synthesizing SACs with high metal loadings while retaining uniform dispersion remains a significant challenge. To address the intrinsic challenges of SACs, recent research has expanded into dual-atom catalysts (DACs) and single-atom alloy catalysts (SAACs), providing synergistic active sites and combining the benefits of SACs with bimetallic systems. Furthermore, this review systematically explores the latest advancements in synthesis methods and innovations for SACs for electrochemical water splitting. Additionally, it examines the evolution of catalyst design, emphasizing the unique structural and electronic characteristics of single-site, dual-site, and alloyed SAC systems and highlighting their critical roles in accelerating water-splitting reaction kinetics as well as the prevailing challenges and outlining promising directions for advancing hydrogen production via water electrolysis.

08 HYDROGEN

Adaptive Reinforcement Learning (ARL) Control of a Multi-port Resonant Converter in UAV Systems

This study presents an adaptive reinforcement learning (ARL) control framework for a multi-port resonant converter used in hybrid unmanned aerial vehicle (UAV) power systems. The converter integrates high-frequency half-bridge input ports connected to a rectified engine–generator set and a battery energy storage system, along with a semi-bridgeless active rectifier supplying the propulsion load. A deep RL agent is trained to dynamically regulate inter-port phase-shift commands in real time based on flight conditions and load power demand. The ARL controller autonomously identifies phase-shift combinations that maximize conversion efficiency while maintaining stable and coordinated power flow, even under rapidly varying operating scenarios. This data-driven approach eliminates the need for explicit system modeling or extensive manual tuning and enables coordinated control among multiple power ports without inter-port communication. Experimental results validate that the ARL based strategy achieves reliable power sharing and consistently high-efficiency operation across diverse UAV operating conditions.

Asa, Erdem [ORNL] (ORCID:0000000190884812)

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION