Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Limits and Doses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Systems of Radiological Protection for Ionizing and Non-Ionizing Radiation

This paper summarizes the presentations and panel discussion held at Plenary Session 1 of the 16th IRPA International Congress/69th Health Physics Society Annual Meeting, in Orlando, FL, in July 2024. Plenary Session 1 discussed the basics of the systems of radiological protection (RP) for ionizing radiation (IR) and non-ionizing radiation (NIR) and included five presentations and a panel discussion. Rodney Croft, Chair of the International Commission on Non-Ionizing Radiation Protection (ICNIRP), delivered the first presentation. Croft introduced the System of RP for NIR and provided an overview of ICNIRP’s coverage and current areas of work. Werner Rühm, Chair of the International Commission on Radiological Protection (ICRP), delivered the second presentation. He gave an overview of the System of RP for IR and covered the key principles of justification, optimization, and dose limitation, including the current plans of ICRP toward the envisaged revision of the System of RP. The third speaker, Sigurður Magnús Magnússon, from the International Radiation Protection Association (IRPA), provided the perspective of the RP professionals on the development of the Systems of RP for IR and NIR. Emilie van Deventer, from the World Health Organization (WHO), presented WHO’s views of both Systems of RP and discussed the relevant current activities of WHO with regard to IR and NIR. Kathryn Higley, President of the National Council on Radiation Protection and Measurements (NCRP), delivered the final presentation. Higley outlined the history of NCRP, the differences between ICRP and NCRP, and discussed the role of the NCRP in the System of RP, including NCRP’s role to analyze mechanisms of interaction of NIR with biological systems, including humans. The session concluded with a fruitful panel discussion, where the audience had the opportunity to ask the five invited speakers questions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multislice Electron Tomography Using Four-Dimensional Scanning Transmission Electron Microscopy

Electron tomography offers useful three-dimensional (3D) structural information, which cannot be observed by two-dimensional imaging. By combining annular dark-field scanning transmission electron microscopy (ADF STEM) with aberration correction, the resolution of electron tomography has reached atomic resolution. However, tomography based on ADF STEM inherently suffers from several issues, including a high electron-dose requirement, poor contrast for light elements, and artifacts from image-contrast nonlinearity. Here, we develop an alternative method called multislice electron tomography (MSET) based on four-dimensional STEM tilt series. In this study, our simulations show that multislice-based 3D reconstruction can effectively reduce undesirable reconstruction artifacts from the nonlinear contrast, allowing precise determination of atomic structures with improved sensitivity for low-Z elements, at considerably low electron-dose conditions. We expect that the MSET method can be applied to a wide variety of materials, including radiation-sensitive samples and materials containing light elements whose 3D atomic structures have never been fully elucidated due to electron-dose limitations or nonlinear imaging contrast.

74 ATOMIC AND MOLECULAR PHYSICS↗

Broadband X-ray ptychography using multi-wavelength algorithm

Ptychography is a rapidly developing scanning microscopy which is able to view the internal structures of samples at a high resolution beyond the illumination size. The achieved spatial resolution is theoretically dose-limited. A broadband source can provide much higher flux compared with a monochromatic source; however, it conflicts with the necessary coherence requirements of this coherent diffraction imaging technique. In this paper, a multi-wavelength reconstruction algorithm has been developed to deal with the broad bandwidth in ptychography. Compared with the latest development of mixed-state reconstruction approach, this multi-wavelength approach is more accurate in the physical model, and also considers the spot size variation as a function of energy due to the chromatic focusing optics. Therefore, this method has been proved in both simulation and experiment to significantly improve the reconstruction when the source bandwidth, illumination size and scan step size increase. It is worth mentioning that the accurate and detailed information of the energy spectrum for the incident beam is not required in advance for the proposed method. Further, we combine multi-wavelength and mixed-state approaches to jointly solve temporal and spatial partial coherence in ptychography so that it can handle various disadvantageous experimental effects. The significant relaxation in coherence requirements by our approaches allows the use of high-flux broadband X-ray sources for high-efficient and high-resolution ptychographic imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microbial vitamin biosynthesis links gut microbiota dynamics to chemotherapy toxicity

ABSTRACT Dose-limiting toxicities pose a major barrier to cancer treatment. While preclinical studies show that the gut microbiota influences and is influenced by anticancer drugs, data from patients paired with careful side effect monitoring remains limited. Here, we investigate capecitabine (CAP)-microbiome interactions through longitudinal metagenomic sequencing of stool from 56 advanced colorectal cancer patients. CAP significantly altered the gut microbiome, enriching for menaquinol (vitamin K2) biosynthesis genes. Transposon library screens, targeted gene deletions, and media supplementation revealed that menaquinol biosynthesis protectsEscherichia colifrom drug toxicity. Stool menaquinol gene and metabolite levels were associated with decreased peripheral sensory neuropathy. Machine learning models trained in this cohort predicted toxicities in an independent cohort. Taken together, these results suggest treatment-associated increases in microbial vitamin biosynthesis serve a chemoprotective role for bacterial and host cells. Further, our findings provide a foundation for in-depth mechanistic dissection, human intervention studies, and extension to other cancer treatments. IMPORTANCE Side effects are common during the treatment of cancer. The trillions of microbes found within the human gut are sensitive to anticancer drugs, but the effects of treatment-induced shifts in gut microbes for side effects remain poorly understood. We profiled gut microbes in colorectal cancer patients treated with capecitabine and carefully monitored side effects. We observed a marked expansion in genes for producing vitamin K2 (menaquinone). Vitamin K2 rescued gut bacterial growth and was associated with decreased side effects in patients. We then used information about gut microbes to develop a predictive model of drug toxicity that was validated in an independent cohort. These results suggest that treatment-associated increases in bacterial vitamin production protect both bacteria and host cells from drug toxicity, providing new opportunities for intervention and motivating the need to better understand how dietary intake and bacterial production of micronutrients like vitamin K2 influence cancer treatment outcomes.

Microbiology↗

Biokinetic and Dosimetric Models [Slides]

Presentation describes internal dosimetry as an intersection of disciplines involving Physiology, Anatomy, Physics, Mathematics and Computer Science, which some people call "The art of Internal Dosimetry". The basic components for internal dose calculations are: Biokinetic (metabolic) models describing the intake, distribution, retention and excretion of radionuclides in the body, Dosimetric models describing the interaction of radiation within the several body organs and tissues, and System of dose limitation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Naval Reactors Facility Environmental Monitoring Report (CY2020)

This report presents the results of the radiological and non-radiological environmental monitoring programs for 2020 at the Naval Reactors Facility (NRF). Current operations at NRF are in compliance with applicable regulations governing use, emission, and disposal of solid, liquid, and gaseous materials. The results obtained from the environmental monitoring programs verify that releases to the environment from operations at NRF did not have any adverse effect on human health or the environment. Evaluation of the environmental data confirms that the operation of NRF continues to have no adverse effect on the environment or the health and safety of the general public. Furthermore, a conservative assessment of radiation exposure to the general public as a result of NRF operations demonstrated that the maximum potential dose received by any member of the public was well below the most restrictive dose limits prescribed by the US Environmental Protection Agency (EPA), the US Department of Energy (DOE), and the Nuclear Regulatory Commission.

54 ENVIRONMENTAL SCIENCES↗

Naval Reactors Facility Environmental Monitoring Report (CY2019)

This report presents the results of the radiological and non-radiological environmental monitoring programs for 2019 at the Naval Reactors Facility (NRF). Current operations at NRF are in compliance with applicable regulations governing use, emission, and disposal of solid, liquid, and gaseous materials. The results obtained from the environmental monitoring programs verify that releases to the environment from operations at NRF did not have any adverse effect on human health or the environment. Evaluation of the environmental data confirms that the operation of NRF continues to have no adverse effect on the environment or the health and safety of the general public. Furthermore, a conservative assessment of radiation exposure to the general public as a result of NRF operations demonstrated that the maximum potential dose received by any member of the public was well below the most restrictive dose limits prescribed by the US Department of Energy (DOE) and the Nuclear Regulatory Commission.

54 ENVIRONMENTAL SCIENCES↗

Glucuronidase Function in Clinical Samples

The purpose of this CRADA is to expand upon the work previously performed through CRADA No. PNNL/381. As explained in the previous CRADA, Glucuronidase enzymes are important for contributing to enterohepatic recycling of numerous therapeutic drug compounds, resulting in impaired or prolonged drug activity. Further, other pathways within the gut, such as bile acid metabolism through the action of bile salt hydrolase enzymes (BSH), have shown to impact both the development of colon cancers and impact recovery. Adapting the activity-based protein profiling (ABPP) technologies developed at PNNL to a microtiter plate-based chemical probe assay was the first step in demonstrating the clinical usability of the technology. With assay proof-of-concept complete through CRADA No. PNNL/381, clinical cohort testing using the developed assay is the next step towards commercialization of this technology. Some chemotherapeutic agents are mediated by gut-produced microbiota through enterohepatic circulation. For example, irinotecan, the first line treatment for many colon and other cancers, can be recycled into a patient’s system through gut microbiota produced glucuronidase enzymes. A significant percentage of patients subjected to irinotecan treatment experience dose-limiting diarrhea and gastric distress that limits treatment options and delays effective intervention. Relatedly, bile salt hydrolases modify ratios of bile acids in the gut, which alter nutrient and pharmaceutical uptake by the intestines and impact patient response to treatment. Coupled together these gut-mediated disorders can significantly decrease patient outcomes. In this project, we propose to investigate a clinical cohort of samples from colon cancer patients to better understand gut microbiome activities surrounding microbiota produced glucuronidases to aid clinician decisions and enhance therapeutic intervention. Our project will measure glucuronidase activity of individual patients and compare this activity to a variety of factors, including patient medical history, treatment response, and overall outcomes. Data will be compared with metagenomic, metabolomic, and proteomic analyses to fully defined the entire gut microbiome space and correlate results with the glucuronidase activity. Resultant analysis is expected to provide actionable information to direct decision making towards therapeutic intervention.

59 BASIC BIOLOGICAL SCIENCES↗

Radon Survey of Los Alamos National Laboratory Buildings and Los Alamos County Residential Buildings

A radon survey of office spaces was of interest to LANL for several reasons. First, exposure to natural radon in LANL office spaces has been considered to be outside the regulatory reach of the federal regulations and the U.S. Department of Energy (U.S. DOE) orders, and thus has not been studied as extensively as occupational exposure to other radionuclides and is not subject to the same rigorous radiological controls. Second, a general survey of radon concentrations in LANL workspaces was of interest to management to ensure safe environments for workers and is in keeping with the intent of OSHA requirements. Though radon in LANL offices would not be derived from enhanced radioactive sources, radon exposure in general office spaces has the potential to significantly impact worker risk. The purpose of the 2009 radon survey was to measure and document indoor radon levels across a broad spectrum of office-type workspaces and neighboring homes. The measured concentrations were compared against those measured across the United States and across the world. The results were also compared against a wide variety of radiation protection thresholds such as (1) the action levels of 148 Bq m -3 (the U.S. EPA action level for public housing), (2) ≈1,200 Bq m -3 OSHA threshold for office spaces, (3) effective dose threshold of 1 mSv threshold for defining a radiological worker, (4) 50 mSv occupational effective dose limit, and (5) 0.1 mSv and 1 mSv limits for public exposures from the air pathway and all pathways, respectively.

07 ISOTOPE AND RADIATION SOURCES↗

Quantifying the Impact of Excluding the Submersion Exposure Route for Existing Superfund Radionuclide Screening Level Calculator Soil and Tap Water Models

The U.S. Environmental Protection Agency (EPA) provides initial data screening guidelines for radionuclide-contaminated Superfund sites using preliminary remediation goals (PRGs) and dose compliance concentrations (DCCs). PRGs and DCCs are target concentration values based on acceptable excess lifetime cancer risk and annual dose limits, respectively. They are calculated for various environmental media that may be encountered by residential and worker land uses. PRGs and DCCs typically consist of multiple exposure routes. One of these routes is submersion, which is exposure to a gaseous or particulate radionuclide that is suspended in air. Currently, submersion is only included in air calculations. This study focused on determining whether factoring submersion into total PRG/DCC calculations for soil and tap water created a significant difference in the target concentrations. New equations for individual submersion PRGs/DCCs for each land use of interest for soil and tap water were developed. A wind-driven particulate emission factor and Andelman’s constant were used to model the amount of soil and vapor in the air from soil and household use of tap water, respectively. The submersion PRG/DCC was then included in the total PRG/DCC for each radionuclide, followed by a percent difference comparison of the old and new totals to quantify the impact of the change. For total soil PRGs/DCCs, with and without submersion, the difference was less than 1 percent; however, many of the tap water radionuclides analyzed – including multiple radon and polonium isotopes – showed as high as a 200 percent difference.This technical memorandum (TM) presents recommendations for updates to current EPA guidelines for initial data screens of radionuclide contaminated tap water.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Basis for Dose and Reactor Safety Design Criteria for Army Regulation AR 50–7 and DA Pamphlet

This report describes the basis used to develop the radiological dose acceptance and design criteria contained in the draft updates to Army Regulation 50–7 (AR 50–7) Army Reactor Program and its accompanying draft Department of the Army (DA) Pamphlet (PAM), Army Reactor Program Procedures. These criteria will apply to Army nuclear reactors that fall under AR 50–7 and its accompanying DA PAM and ensure alignment with the overall objectives of the Army Reactor Program. The development basis for the radiological dose and design criteria supports a modern, technology-neutral, risk-informed, and performance-based approach to Army regulation of reactors and the demonstration of “adequate protection of the public.” To establish these criteria that support the Army’s unique operational requirements, multiple well-known and well-established standards and their supporting documentation were reviewed to ensure consistency with existing regulatory safety levels, including guidance from U.S. and international sources. These include the U.S. Nuclear Regulatory Commission’s (NRC’s) regulations and policy, the Canadian Nuclear Safety Commission’s (CNSC’s) regulatory documents, the International Atomic Energy Agency’s (IAEA’s) safety standards, as well as industry input that is tailored specifically to advanced microreactors. This report walks through the key definitions and associated references used for these criteria, which are outlined in Section 2.0. Based on these definitions, the dose acceptance criteria were established for various receptors for routine reactor operations (Section 3.2), design basis accidents (Section 3.3), and beyond design basis accidents (Section 3.4). Comparisons of multiple national and international dose limits are provided in these sections. Lastly, Section 4.0 outlines the reactor safety design criteria contained in the draft DA PAM and their associated bases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

225 Ac-MACROPATATE: A Novel α-Particle Peptide Receptor Radionuclide Therapy for Neuroendocrine Tumors

Neuroendocrine tumors (NETs) express somatostatin receptors (SSTRs) 2 and 5. Modified variants of somatostatin, the cognate ligand for SSTR2 and SSTR5, are used in treatment for metastatic and locoregional disease. Peptide receptor radionuclide therapy with 177 Lu-DOTATATE (DOTA-octreotate), a β-particle–emitting somatostatin derivative, has demonstrated survival benefit in patients with SSTR-positive NETs. Despite excellent results, a subset of patients has tumors that are resistant to treatment, and alternative agents are needed. Targeted α-particle therapy has been shown to kill tumors that are resistant to targeted β-particle therapy, suggesting that targeted α-particle therapy may offer a promising treatment option for patients with 177 Lu-DOTATATE–resistant disease. Although DOTATATE can chelate the clinically relevant α-particle–emitting radionuclide 225 Ac, the labeling reaction requires high temperatures, and the resulting radioconjugate has suboptimal stability. Methods: We designed and synthesized MACROPATATE (MACROPA-octreotate), a novel radioconjugate capable of chelating 225 Ac at room temperature, and assessed its in vitro and in vivo performance. Results: MACROPATATE demonstrated comparable affinity to DOTATATE (dissociation constant, 21 nM) in U2-OS-SSTR2, a SSTR2-positive transfected cell line. 225 Ac-MACROPATATE demonstrated superior serum stability at 37°C over time compared with 225 Ac-DOTATATE. Biodistribution studies demonstrated higher tumor uptake of 225 Ac-MACROPATATE than of 225 Ac-DOTATATE in mice engrafted with subcutaneous H69 NETs. Therapy studies showed that 225 Ac-MACROPATATE exhibits significant antitumor and survival benefit compared with saline control in mice engrafted with SSTR-positive tumors. However, the increased accumulation of 225 Ac-MACROPATATE in liver and kidneys and subsequent toxicity to these organs decreased its therapeutic index compared with 225 Ac-DOTATATE. Conclusion: 225 Ac-MACROPATATE and 225 Ac-DOTATATE exhibit favorable therapeutic efficacy in animal models. Because of elevated liver and kidney accumulation and lower administered activity for dose-limiting toxicity of 225 Ac-MACROPATATE, 225 Ac-DOTATATE was deemed the superior agent for targeted α-particle peptide receptor radionuclide therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Structural Characterization of Linker Shielding in ADC Site-Specific Conjugates

Background/Objectives: Antibody–Drug Conjugates (ADCs) have rapidly evolved from early, rudimentary conjugates to highly targeted and precisely engineered molecules. Despite notable clinical successes, ADCs continue to face significant challenges, including aggregation and high hydrophobicity driven by high drug-to-antibody ratios (DARs), premature payload release, dose-limiting toxicities, and suboptimal pharmacokinetics. While site-specific linker–payload conjugation has improved ADC homogeneity and stability, the structural basis of antibody–linker interactions at specific sites remains underexplored. Methods: In this work, we present the crystal structures of trastuzumab Fab and Fc domains site-specifically conjugated with a cleavable linker–payload. Results: Our findings suggest that pockets within both Fab and Fc regions may interact with and shield the linker portion of the conjugate. Conclusions: These insights highlight the previously underappreciated potential of structure-based design to drive the optimization of ADC linker chemistry and facilitate the co-design of bespoke linker–payloads tailored to individual antibody conjugation sites.

Jaime-Garza, Maru [Discovery Chemistry, Merck & Co↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Second Target Station Bunker Shielding with Populated and Unpopulated Neutron Beamlines: Preliminary Design

At the U.S. Department of Energy’s Oak Ridge National Laboratory, the Second Target Station (STS) beamline sources for preliminary design have been used to perform a shielding analysis of the bunker. Prompt total effective dose rates (i.e., neutron plus photon effective dose rates when the proton beam is on) were calculated on top of the bunker roof and outside the bunker wall. These areas outside the bunker will be generally accessible, so the prompt total dose rate in these areas should not exceed 2.5 μSv . h -1 (0.25 mrem . h -1 ). This paper presents the required shielding thicknesses to meet this dose rate limit. In one instance, this dose rate limit is not met: For a combination of populated and unpopulated beamlines, the prompt total dose rate outside the bunker across from the unpopulated beamline, which has less shielding because of the lack of beamline shielding, slightly exceeds 2.5 μSv . h -1 . In conclusion, once more details are known regarding the STS high-density concrete density and composition, a future analysis will investigate the shielding modifications required to reduce the calculated prompt total dose rates for this configuration to less than 2.5 μSv . h -1 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Requirements and Conceptual Design of Off-gas Systems for the Reprocessing of Metallic Fuels

An assessment has been conducted to determine how key regulations regarding volatile radionuclide emissions to the atmosphere may apply to the off-gas streams associated with electrochemical reprocessing. The scope of this assessment was based upon a generic electrochemical reprocessing scheme with a throughput rate of 200 MTIHM/y applied to metallic fuel discharged from a sodium fast reactor (SFR), but the findings are able to be translated to other advanced nuclear scenarios as merited. Air dispersion modeling was performed using the EPA CAP-88 model and evaluated the uncontrolled decontamination factors (DFs) that would be required to achieve regulatory compliance with the dose-based limits set forth by EPA regulation 40 CFR 190.10(a). These DFs were compared to those required by fuel cycle–based limits set forth by EPA regulation 40 CFR 190.10(b). Two theoretical sites with disparate climatological conditions were selected for air dispersion modeling (Idaho and Tennessee). The radionuclides modeled included 3 H, 85 Kr, 129 I, and selected alpha-emitting transuranic isotopes (referred to here as 239 Pu-TRU <1y ). It was found that the fuel cycle-based limits in 40 CFR 190.10(b) are most restrictive for 85 Kr and 239 Pu-TRU <1y , with DFs of 3 and 6.1E+09, respectively. The dose-based limit as derived from 40 CFR 190.10(a) could require mitigation of tritium in some scenarios, with an estimated DF of about 3 for the reference scenarios. The fuel cycle-based limit for 129 I resulted in a DF of about 240 for the reference scenario. The need for iodine mitigation based on dose to the public depended upon the physical form of iodine as either particulate or vapor-phase species. Emission of iodine from the facility as a vapor necessitated DFs of about 2 but emission as a particulate would require DFs >6,000 to meet thyroid dose-based limits. Effects of physical form on needed iodine mitigation are significant, but the understanding of speciation of iodine both during electrochemical reprocessing and after release to the atmosphere is limited. The electrochemical processing unit operations were evaluated to identify potential release points for the volatile radionuclides and to assess the potential for retention of the radionuclides within the process (thus decreasing the need for mitigation). Mitigation strategies for 3 H, 85 Kr, 129 I, and 239 Pu-TRU <1y were identified. In all cases, there are reasonably achievable pathways to regulatory compliance, although in some cases additional R&D is merited to verify the chemical speciation of these isotopes and to develop and demonstrate potential treatment technologies for this application. Whether or not additional off-gas controls (beyond common operations such as HEPA filtration and oxygen and moisture control) are needed for any of these regulated or volatile radionuclides depends on the (a) type of facility (NRC-regulated or DOE), (b) used fuel process rate, (c) used fuel burnup and composition, (d) speciation and retention of volatile radionuclides in the process and in the cell gas cleanup system, (e) site-specific parameters such as location, meteorology, stack height, and site boundaries, and (f) levels of conservatism and safety factors used in assessing compliance to air emissions regulations. Performance of this assessment revealed several areas where information is lacking or additional research is required in order to better determine if or what kinds of off-gas control might be needed. First, and most significantly, the understanding of the chemical speciation and physical form and partitioning of iodine during electrochemical processing operations is lacking and prevents the ability to accurately assess the potential iodine mitigation requirements. Future research in this area should be multifaceted and include thermodynamic modeling of iodine speciation in different process steps, experiments to quantify the kinetics of vapor-phase and melt-phase transitions, bench-scale experiments to determine the potential chemical and physical form of iodine emissions from the electrorefining process, and verification of iodine behavior with experiments utilizing operational facilities. Similarly, an improved understanding of iodine behavior in the environment after release from the facility stack will be required to refine dose estimations, as particulate and vapor-phase emissions result in significantly different doses to the MEI.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Oxygen Consumption as a Sensitive Measure of Electrical Cable Polymer Insulation Degradation

Polymers used as dielectric materials in nuclear grade electrical cables, such as cross-linked polyethylene (XLPE) and ethylene-propylene rubber (EPR), are long-lived and durable. Estimating the decades-long useful service life of polymers experimentally in a feasible timeframe of weeks or months requires greatly accelerated aging in the laboratory at elevated temperatures and/or gamma dose rates. Many limitations of accelerated aging, such as due to artefacts of the process including diffusion limited oxidation and dose rate effects, have been identified that can make accurate lifetime prediction at service conditions challenging. This can be due to differences in degradation mechanisms between rapid and extended aging or to the presence of induction periods during which early aging is undetectable using common metrics of polymer insulation characterization such as tensile elongation at break. Conceptually, an ideal measure of aging would track clearly and predictably with material changes throughout the lifecycle of the evolving material state from early aging through end of useful life. With such a metric accelerated aging could be performed at much milder conditions, conditions closer to those found in long term service, and end of life calculated from the early data. Oxygen consumption has previously been proposed as a sensitive measure of insulation polymer oxidation that might meet such desirable characteristics. In this work, nuclear cable insulation samples of the two most common types, XLPE and EPR, from two of the most sourced manufacturers, RSCC and The Okonite Company, were subjected to gamma irradiation at dose rates of 100, 200, and 300 Gy/hr for up to 42 days at 26°C. The aged samples were used to evaluate oxygen consumption as a sensitive measure of aging for these materials and these conditions. For comparison and validation, the aged samples were also characterized using the more conventional tests of mass change, density, carbonyl index, and yellowness index. For both materials, oxygen consumption during irradiation was found to track consistently with applied dose—oxygen consumption rate was linear with time. Mass change and carbonyl index were also clearly proportional to exposure dose. Yellowness index, a surface sensitive measure, was observed to increase linearly with dose at low exposure levels before plateauing. Sample density was not observed to change under the conditions explored. Oxygen consumption was found to be a particularly sensitive metric to measure the degradation of polymeric cable insulation exposed to radiation. Oxygen consumption was compared to Arrhenius and time-temperature-superposition methods for activation energy calculation using literature date and found to be a useful and viable alternative for lifetime prediction. The techniques developed in this work are anticipated to be valuable in the estimation of insulation aging rates under mild conditions approaching service conditions. Direction comparison of useful life prediction by oxygen consumption with prediction via Arrhenius methodology for thermal aging and existing methods for radiation and combined thermal/radiation aging would serve to further validate this promising approach and refine our understanding of material-specific aging rates.

36 MATERIALS SCIENCE↗