Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LiBr”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of a solar powered residential air conditioner (General optimization)

A commercially available 3-ton residential Lithium Bromide (LiBr) absorption air conditioner was modified for use with lower temperature solar heated water. The modification included removal of components such as the generator, concentration control chamber, liquid trap, and separator; and the addition of a Chrysler designed generator, an off-the-shelf LiBr-solution pump. The design goal of the modified unit was to operate with water as the heat-transfer fluid at a target temperature of 85 C (185 F), 29.4 C (85 F) cooling water inlet, producing 10.5 kW (3 tons) of cooling. Tests were performed on the system before and after modification to provide comparative data. At elevated temperatures (96 C, 205 F), the test results show that Lithium Bromide was carried into the condenser due to the extremely violent boiling and degraded the evaporator performance.

Lowen, D. J.↗

Aluminium Electroplating on Steel from a Fused Bromide Electrolyte

A quaternary bromide bath (LiBr-KBr-CsBr-AlBr3) was used to electro-coat aluminium on steel substrates. The electrolyte was prepared by the addition of AlBr3 into the eutectic LiBr-KBr-CsBr melt. A smooth, thick, adherent and shiny aluminium coating could be obtained with 80 wt.% AlBr3 in the ternary melt. The SEM photographs of the coated surfaces suggest the formation of thick and dense coatings with good aluminium coverage. Both salt immersion and open circuit potential measurement suggest that the coatings did display good corrosion-resistance behavior. Annealing of the coated surfaces, prior to corrosion tests, suggested the robustness of the metallic aluminium coating in preventing the corrosion of the steel surfaces. Studies also indicated that the quaternary bromide plating bath can potentially provide a better aluminium coating on both ferrous and non-ferrous metals, including complex surfaces/geometries.

36 MATERIALS SCIENCE↗

Testing of Crystallization Temperature of a New Working Fluid for Absorption Heat Pump Systems

Lithium bromide/water (LiBr/water) absorption systems are potential candidates for absorption heat pump water heating applications since they have been widely commercialized for cooling applications. One drawback to LiBr/water absorption water heater systems is that they are unable to operate at typical water heating temperatures due to solution crystallization hazards. Binary or ternary mixtures, serving as working fluids, were reported (Ally, 1988; Herold et al., 1991; Iyoki and Uemura, 1981; Yasuhide Nemoto et al., 2010; Zogg et al., 2005) to help improve the absorption performance or avoid crystallization of absorption heat pump systems. A recent development (De Lucas et al., 2007) investigated the use of a ternary mixture of aqueous mixture of lithium bromide and sodium formate (CHO2Na). The new working fluid composition maintains a ratio of LiBr/CHO2Na of 2 by weight. This new working fluid is a potential competitor to aqueous LiBr solution in absorption system due to higher water vapor absorption rates and lower generation temperature needed (De Lucas et al., 2004). There exists data on equilibrium performance and other physical properties of this new working fluid. However, there is no available data on crystallization behavior. Crystallization temperature is crucial for the design of absorption heat pump water heater in order to avoid crystallization hazards during operation. We have therefore conducted a systematic study to explore the crystallization temperature of LiBr/CHO2Na water solution and compared it against aqueous LiBr solutions. These results were then used to evaluate the feasibility of using the new working fluid in water heating applications showing limited potential.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light‐Driven Water Splitting Mediated by Photogenerated Bromine

Abstract Light‐driven water splitting was achieved using a dye‐sensitized mesoporous oxide film and the oxidation of bromide (Br − ) to bromine (Br 2 ) or tribromide (Br 3 − ). The chemical oxidant (Br 2 or Br 3 − ) is formed during illumination at the photoanode and used as a sacrificial oxidant to drive a water oxidation catalyst (WOC), here demonstrated using [Ru(bda)(pic) 2 ], ( 1 ; pic=picoline, bda=2,2′‐bipyridine‐6,6′‐dicarboxylate). The photochemical oxidation of bromide produces a chemical oxidant with a potential of 1.09 V vs. NHE for the Br 2 /Br − couple or 1.05 V vs. NHE for the Br 3 − /Br − couple, which is sufficient to drive water oxidation at 1 (Ru V/IV ≈1.0 V vs. NHE at pH 5.6). At pH 5.6, using a 0.2 m acetate buffer containing 40 m m LiBr and the [Ru(4,4′‐PO 3 H 2 ‐bpy)(bpy) 2 ] 2+ ( RuP 2+ , bpy=2,2′‐bipyridine) chromophore dye on a SnO 2 /TiO 2 core–shell electrode resulted in a photocurrent density of around 1.2 mA cm −2 under approximately 1 Sun illumination and a Faradaic efficiency upon addition of 1 of 77 % for oxygen evolution.

Sheridan, Matthew V.↗

Light-Driven Water Splitting Mediated by Photogenerated Bromine

Light-driven water splitting was attained using a dye-sensitized mesoporous oxide film and the oxidation of bromide (Br–) to bromine (Br 2 ) or tribromide (Br 3 –). The chemical oxidant (Br 2 or Br 3 –) is formed during illumination at the photoanode and used as a sacrificial oxidant to drive a water oxidation catalyst (WOC), here shown using [Ru(bda)(pic) 2 ], (1; pic=picoline, bda=2,2'-bipyridine-6,6'-dicarboxylate). The photochemical oxidation of bromide produces a chemical oxidant with a possibility of 1.09 V vs. NHE for the Br 2 /Br– couple or 1.05 V vs. NHE for the Br 3 –/Br– couple, which is sufficient to drive water oxidation at 1 (Ru V/IV ≈1.0 V vs. NHE at pH 5.6). At pH 5.6, using a 0.2 M acetate buffer containing 40 mm LiBr and the [Ru(4,4'-PO3H2-bpy)(bpy) 2 ] 2+ (RuP 2+ , bpy=2,2'-bipyridine) chromophore dye on a SnO 2 /TiO 2 core–shell electrode resulted in a photocurrent density of around 1.2 mA cm –2 under approximately 1 Sun illumination and a Faradaic efficiency upon addition of 1 of 77 % for oxygen evolution.

25 ENERGY STORAGE↗

Ionic liquid-based hybrid absorption cycle for water heating, dehumidification, and cooling

Water heating, dehumidification and space cooling are responsible for significant energy consumption in buildings. A potential energy saving measure is to develop hybrid systems that can utilize the sensible and latent heats removed in space cooling to heat water. In this paper, we present experimental results on a hybrid system that utilizes the latent heat released in the dehumidification process for water heating. This system absorbs water vapor from the air and transfers the heat of phase change into the process water. The absorbed water vapor is then liberated in a desorber and subsequently condensed in a condenser, while its latent heat is transferred to the process water. The condensed water vapor can then be either drained (if dehumidification is desired), or utilized in an evaporative cooling process (if sensible space cooling is desired). In essence, the system can exchange both sensible and latent heats with its ambient. The main innovations implemented in the system are (1) a semi-open absorption system architecture to lower the system cost, (2) a membrane-based absorber to alleviate the liquid entrainment issue encountered in the conventional packed bed absorbers and (3) an ionic liquid that eliminates the crystallization risks and minimizes corrosion issues normally associated with LiBr-based absorption systems. Furthermore, a water heating thermal COP of 1.4 is achieved at 30°C, 70% RH ambient conditions.

42 ENGINEERING↗

Computational and experimental analysis of structural and Thermophysical properties of LiX-KX (X = chloride, iodide, or bromide) molten salts

Molten salts containing lithium (Li) and potassium (K) halides, including chlorides (Cl), bromides (Br), and iodides (I), are pivotal in advanced technological applications including nuclear reactor technologies, thermal batteries, and industrial pyrochemical processes. Despite their significance, the availability of the temperature-dependent structural and thermophysical properties of these molten salts remain scarce. Here, this study addresses this knowledge gap by predicting and measuring the key properties such as coordination number, radial distribution function, density, heat capacity, and volumetric thermal expansion of molten LiI-KI, LiBr-KBr and LiCl-KCl eutectic mixtures. Utilizing ab initio molecular dynamics (AIMD) simulations, we predict these properties of LiX-KX (X=Br,I, Cl) across various temperatures, with chlorides as a benchmark. Experimental measurements using Archimedes methods and Differential Scanning Calorimetry validate the densities and heat capacities of these molten salts. Our comprehensive analysis of the structural and thermophysical properties provides critical insights into the behavior of these molten salts at various temperatures, enhancing the understanding necessary for their application in advanced technologies.

36 - MATERIALS SCIENCE↗

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

State-of-the-Art Review on Crystallization Control Technologies for water/LiBr Absorption Heat Pumps

The key technical barrier to using water/lithium bromide (LiBr) as the working fluid in aircooled absorption chillers and absorption heat-pump systems is the risk of crystallization when the absorber temperature rises at fixed evaporating pressure. This article reviews various crystallization control technologies available to resolve this problem: chemical inhibitors, heat and mass transfer enhancement methods, thermodynamic cycle modifications, and absorption system-control strategies. Other approaches, such as boosting absorber pressure and J-tube technology, are reviewed as well. This review can help guide future efforts to develop water/LiBr air-cooled absorption chillers and absorption heatpump systems.

99 GENERAL AND MISCELLANEOUS↗

Osmotic and activity coefficients for five lithium salts in three non–aqueous solvents

To obtain osmotic coefficients, a classic static–view apparatus was used to measure the difference between the vapor pressure of a solvent and that of its salt solution at 25 °C. Vapor–pressure lowering was measured for solutions containing a lithium salt (LiCl, LiBr, LiNO 3 , LiPF 6 and LITFSI) dissolved in a non–aqueous solvent (dimethyl carbonate, dimethyl sulfoxide and acetonitrile) that may be used in a lithium–ion battery. The osmotic–coefficient data are represented by Archer's extended Pitzer equation. As a result, mean ionic activity coefficients for the salts are calculated from the osmotic–coefficient data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lithium halide cathodes for Li metal batteries

Lithium halides cathodes potentially offer a high energy density at a low cost for rechargeable batteries. However, these cathodes suffer from quick capacity decay in organic electrolytes and the failiure mechanism remains elusive. Here, we report that liquefying the halogen or interhalogen compounds is a prerequisite for achieving high reversibility for the lithium halides cathodes. The gas or solid halogen can be liquefied by using interhalogen compounds with different electronegativity or changing the temperature. As a proof of concept, reversible LiCl conversion-intercalation chemistry in organic electrolyte is demonstrated by using either redox coupling with less electronegative I/Br to form liquid ICl/BrCl or reducing the temperature to -30oC. Further, the LiCl-LiBr-graphite cathodes in 1.6M lithium difluoro(oxalato)borate/1.6M lithium triflate in diglyme electrolytes achieve a high reversible specific capacity of 250 mAh/g at 3.7 V with an energy density being comparable to or higher than transition metal oxide cathodes at a much lower cost.

25 ENERGY STORAGE↗

Novel ternary molten salt electrolytes for intermediate-temperature sodium/nickel chloride batteries

The sodium–nickel chloride (ZEBRA) battery is operated at relatively high temperature (250–350 °C) to achieve adequate electrochemical performance. Reducing the operating temperature in the range of 150200 °C can not only lead to enhanced cycle life by suppressing temperature-related degradations, but also allow the use of lower cost materials for construction. To achieve adequate electrochemical performance at lower operating temperatures, reduction in ohmic losses is required, including the reduced ohmic resistance of β"-alumina solid electrolyte (BASE) and the incorporation of low melting point secondary electrolytes. In present work, planar-type Na/NiCl 2 cells with a thin BASE (600 μm) and low melting point secondary electrolyte were evaluated at reduced temperatures. Molten salts used as secondary electrolytes were fabricated by the partial replacement of NaCl in the standard secondary electrolyte (NaAlCl 4 ) with other lower melting point alkali metal salts such as NaBr, LiCl, and LiBr. Electrochemical characterization of these ternary molten salts demonstrated improved ionic conductivity and sufficient electrochemical window at reduced temperatures. Furthermore, Na/NiCl 2 cells with 50 mol% NaBr-containing secondary electrolyte exhibited reduced polarizations at 175 °C compared to the cell with the standard NaAlCl 4 catholyte. Finally, the cells also exhibited stable cycling performance even at 150 °C.

reduced temperature↗

A solar thermal cooling and heating system for a building: Experimental and model based performance analysis and design

A solar thermal cooling and heating system at Carnegie Mellon University was studied through its design, installation, modeling, and evaluation to deal with the question of how solar energy might most effectively be used in supplying energy for the operation of a building. This solar cooling and heating system incorporates 52 m{sup 2} of linear parabolic trough solar collectors; a 16 kW double effect, water-lithium bromide (LiBr) absorption chiller, and a heat recovery heat exchanger with their circulation pumps and control valves. It generates chilled and heated water, dependent on the season, for space cooling and heating. This system is the smallest high temperature solar cooling system in the world. Till now, only this system of the kind has been successfully operated for more than one year. Performance of the system has been tested and the measured data were used to verify system performance models developed in the TRaNsient SYstem Simulation program (TRNSYS). On the basis of the installed solar system, base case performance models were programmed; and then they were modified and extended to investigate measures for improving system performance. The measures included changes in the area and orientation of the solar collectors, the inclusion of thermal storage in the system, changes in the pipe diameter and length, and various system operational control strategies. It was found that this solar thermal system could potentially supply 39% of cooling and 20% of heating energy for this building space in Pittsburgh, PA, if it included a properly sized storage tank and short, low diameter connecting pipes. Guidelines for the design and operation of an efficient and effective solar cooling and heating system for a given building space have been provided. (author)

14 SOLAR ENERGY↗

Transient analysis and energy optimization of solar heating and cooling systems in various configurations

In this paper, a transient simulation model of solar-assisted heating and cooling systems (SHC) is presented. A detailed case study is also discussed, in which three different configurations are considered. In all cases, the SHC system is based on the coupling of evacuated solar collectors with a single-stage LiBr-H{sub 2}O absorption chiller, and a gas-fired boiler is also included for auxiliary heating, only during the winter season. In the first configuration, the cooling capacity of the absorption chiller and the solar collector area are designed on the basis of the maximum cooling load, and an electric chiller is used as the auxiliary cooling system. The second layout is similar to the first one, but, in this case, the absorption chiller and the solar collector area are sized in order to balance only a fraction of the maximum cooling load. Finally, in the third configuration, there is no electric chiller, and the auxiliary gas-fired boiler is also used in summer to feed the absorption chiller, in case of scarce solar irradiation. The simulation model was developed using the TRNSYS software, and included the analysis of the dynamic behaviour of the building in which the SHC systems were supposed to be installed. The building was simulated using a single-lumped capacitance model. An economic model was also developed, in order to assess the operating and capital costs of the systems under analysis. Furthermore, a mixed heuristic-deterministic optimization algorithm was implemented, in order to determine the set of the synthesis/design variables that maximize the energy efficiency of each configuration under analysis. The results of the case study were analyzed on monthly and weekly basis, paying special attention to the energy and monetary flows of the standard and optimized configurations. The results are encouraging as for the potential of energy saving. On the contrary, the SHC systems appear still far from the economic profitability: however, this is notoriously true for the great majority of renewable energy systems. (author)

14 SOLAR ENERGY↗

Solar absorption cooling plant in Seville

A solar/gas cooling plant at the Engineering School of Seville (Spain) was tested during the period 2008-2009. The system is composed of a double-effect LiBr + water absorption chiller of 174 kW nominal cooling capacity, powered by: (1) a pressurized hot water flow delivered by mean of a 352 m{sup 2} solar field of a linear concentrating Fresnel collector and (2) a direct-fired natural gas burner. The objective of the project is to indentify design improvements for future plants and to serve as a guideline. We focused our attention on the solar collector size and dirtiness, climatology, piping heat losses, operation control and coupling between solar collector and chiller. The daily average Fresnel collector efficiency was 0.35 with a maximum of 0.4. The absorption chiller operated with a daily average coefficient of performance of 1.1-1.25, where the solar energy represented the 75% of generator's total heat input, and the solar cooling ratio (quotient between useful cooling and insolation incident on the solar field) was 0.44. (author)

14 SOLAR ENERGY↗

Temperature-Dependent Speciation of Ni(II) in Molten Chloride, Bromide, and Iodide Salts

Understanding the fundamental speciation and local structure of metal cations─such as nickel, which is present as a corrosion product─in molten salt media is essential for assessing their impact on the thermal and physical properties of salts used for advanced nuclear energy applications. In this study, we employed an integrated approach of combining X-ray absorption spectroscopy (XAS), UV–vis spectroscopy, and ab initio molecular dynamics (AIMD) to investigate the halide-dependent speciation of divalent nickel ions, Ni(II), in LiCl–KCl, LiBr–KBr, and LiI–KI eutectic salt mixtures from room temperature to 600 °C. Our findings show that both halide type and temperature significantly influence the local coordination of nickel in these molten salt systems. A notable aspect of Ni(II) speciation in LiI–KI salts is the formation of a polyiodide species. In conclusion, our findings provide critical insights into metal ion speciation in molten salt systems, enhancing our understanding of the factors that govern the physicochemical properties of these complex fluids.

36 MATERIALS SCIENCE↗