Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Lasers and Masers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

In orbit demonstration of a H-maser clock system

The ESA/NASA technology demonstration flight of a pair of hydrogen masers on the EURECA 3 mission is planned for 1998. The ESA part of the experiment will have a maser built by Neuchatel Observatory and a microwave time and frequency transfer system derived from the existing Precise Range and Range Rate Equipment (PRARE) system. The NASA part of the experiment will have a maser built by the Smithsonian Astrophysical Observatory and a laser time transfer system. The technology demonstration experiment is described with its expected outcomes and applications.

Busca, Giovanni↗

Design Considerations for Compact High-Average Power Free-Electron Lasers/Masers at Terahertz Frequencies

Interest is increasing in high-power terahertz (THz) sources of radiation. The terminology is fluid, but researchers in the field typically refer to frequencies ranging from about 300 GHz to 10 THz as THz radiation. In this article, we present a description of design considerations for a compact, high-average power free-electron laser. At present, THz radiation is generated by a variety of mechanisms, including laser-based sources and electron-beam-based sources. Here, we provide a short description of current THz source technology to give background against which to compare the present concept; however, this should not be considered a comprehensive discussion of such technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental comparison of time synchronization techniques by means of light signals and clock transport on the rotating earth

An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.

Nelson, R. A.↗

Carbon-13 Radiofrequency Amplification by Stimulated Emission of Radiation of the Hyperpolarized Ketone and Hemiketal Forms of Allyl [1- 13 C]Pyruvate

13 C hyperpolarized pyruvate is an emerging MRI contrast agent for sensing molecular events in cancer and other diseases with aberrant metabolic pathways. This metabolic contrast agent can be produced via several hyperpolarization techniques. Despite remarkable success in research settings, widespread clinical adoption faces substantial roadblocks because the current sensing technology utilized to sense this contrast agent requires the excitation of 13 C nuclear spins that also need to be synchronized with MRI field gradient pulses. Here, we demonstrate sensing of hyperpolarized allyl [1- 13 C]pyruvate via the stimulated emission of radiation that mitigates the requirements currently blocking broader adoption. Specifically, 13 C Radiofrequency Amplification by Stimulated Emission of Radiation ( 13 C RASER) was obtained after pairwise addition of parahydrogen to a pyruvate precursor, detected in a commercial inductive detector with a quality factor (Q) of 32 for sample concentrations as low as 0.125 M with 13 C polarization of 4%. Moreover, parahydrogen-induced polarization allowed for the preparation of a mixture of ketone and hemiketal forms of hyperpolarized allyl [1- 13 C]pyruvate, which are separated by 10 ppm in 13 C NMR spectra. This is a good model system to study the simultaneous 13 C RASER signals of multiple 13 C species. This system models the metabolic production of hyperpolarized [1- 13 C]lactate from hyperpolarized [1- 13 C]pyruvate, which has a similar chemical shift difference. Our results show that 13 C RASER signals can be obtained from both species simultaneously when the emission threshold is exceeded for both species. On the other hand, when the emission threshold is exceeded only for one of the hyperpolarized species, 13 C stimulated emission is confined to this species only, therefore enabling the background-free detection of individual hyperpolarized 13 C signals. Furthermore, the reported results pave the way to novel sensing approaches of 13 C hyperpolarized pyruvate, potentially unlocking hyperpolarized 13 C MRI on virtually any MRI system–an attractive vision for the future molecular imaging and diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fiber optics transmit clock signal more reliably

Optical automatic gain control smooths maser clock amplitude fluctuations without phase shift. Uncomplicated optical system is more reliable than electrical transmission circuits which require phase-locked loops to compensate for shift. Maser feeds reference signal to linear fiber-optic analog transmitter which emits modulated laser beam directed to splitter. Splitter consists of dichroic mirrors and associated lenses for distributing beam to output ports. Cables attached there guide signals to receiving station.

Lutes, G. F., Jr.↗

Optical Links and RF Distribution for Antenna Arrays

An array of three antennas has recently been developed at the NASA Jet Propulsion Laboratory capable of detecting signals at X and Ka band. The array requires a common frequency reference and high precision phase alignment to correlate received signals. Frequency and timing references are presently provided from a remotely located hydrogen maser and clock through a combination of commercially and custom developed optical links. The selected laser, photodetector, and fiber components have been tested under anticipated thermal and simulated antenna rotation conditions. The resulting stability limitations due to thermal perturbations or induced stress on the optical fiber have been characterized. Distribution of the X band local oscillator includes a loop back and precision phase monitor to enable correlation of signals received from each antenna.

antenna array↗

Goddard Geophysical and Astronomical Observatory

This report summarizes the technical parameters and the technical staff of the VLBI system at the fundamental station GGAO. It also gives an overview about the VLBI activities during the report year. The Goddard Geophysical and Astronomical Observatory (GGAO) consists of a 5-meter radio telescope for VLBI, a new 12-meter radio telescope for VLBI2010 development, a 1-meter reference antenna for microwave holography development, an SLR site that includes MOBLAS-7, the NGSLR development system, and a 48" telescope for developmental two-color Satellite Laser Ranging, a GPS timing and development lab, a DORIS system, meteorological sensors, and a hydrogen maser. In addition, we are a fiducial IGS site with several IGS/IGSX receivers. GGAO is located on the east coast of the United States in Maryland. It is approximately 15 miles NNE of Washington, D.C. in Greenbelt, Maryland.

Figueroa, Ricardo↗

Mid Infrared Hydrogen Recombination Line Emission from the Maser Star MWC 349A

We have detected and spectrally resolved the mid-IR hydrogen recombination lines H6(alpha)(12.372 micrometers), H7(alpha)(19.062 micrometers), H7(beta)(l1.309 micrometers) and H8(gamma)(12.385 micrometers) from the star MWC349A. This object has strong hydrogen maser emission (reported in the millimeter and submillimeter hydrogen recombination lines from H36(alpha) to H21(alpha)) and laser emission (reported in the H15(alpha), H12(alpha) and H10(alpha) lines). The lasers/masers are thought to arise predominantly in a Keplerian disk around the star. The mid-IR lines do not show evident signs of lasing, and can be well modeled as arising from the strong stellar wind, with a component arising from a quasi-static atmosphere around the disk, similar to what is hypothesized for the near IR (less than or equal to 4 micrometers) recombination lines. Since populations inversions in the levels producing these mid-IR transitions are expected at densities up to approximately 10(exp 11)/cu cm, these results imply either that the disk does not contain high-density ionized gas over long enough path lengths to produce a gain approximately 1, and/or that any laser emission from such regions is small compared to the spontaneous background emission from the rest of the source as observed with a large beam. The results reinforce the interpretation of the far-IR lines as true lasers.

Smith, Howard A.↗

New Tests for Variations of the Fine Structure Constant

We describe a new test for possible variations of the fine structure constant, by comparisons of rates between clocks based on hyperfine transitions in alkali atomos with different atomic number Z. H- maser, Cs and Hg+ clocks have a different dependence on ia relativistic contributions of order (Z. Recent H-maser vs Hg+ clock comparison data improves laboratory limits on a time variation by 100-fold to giveFuture laser cooled clocks (Be+, Rb, Cs, Hg+, etc.), when compared, will yield the most senstive of all tests for.

Fine Structure↗

Physics of molecules

Molecular physics research on maser spectroscopy, electron excitation, molecular spectra of cesium, and related topics

ATOMIC EXCITATION↗

A space system for high-accuracy global time and frequency comparison of clocks

A Space Shuttle experiment in which a hydrogen maser clock on board the Space Shuttle will be compared with clocks on the ground using two-way microwave and short pulse laser signals is described. The accuracy goal for the experiment is 1 nsec or better for the time transfer and 10 to the minus 14th power for the frequency comparison. A direct frequency comparison of primary standards at the 10 to the minus 14th power accuracy level is a unique feature of the proposed system. Both time and frequency transfer will be accomplished by microwave transmission, while the laser signals provide calibration of the system as well as subnanosecond time transfer.

Decher, R.↗

Atomic Clocks and Variations of the FIne Structure Constant

We describe a new test for possible variations of the fine structure constant alpha by comparisons of rates between clocks based on hyperfine transitions in alkali atoms with different atomic number Z. H-maser, Cs, and Hg(+) clocks have a different dependence on alpha via relativistic contributions of order (Z-alpha)(sup 2). Recent H-maser vs Hg(+) clock comparison data improve laboratory limits on a time variation by 100-fold to give dot-alpha less than or equal to 3.7 x 10(exp -14)/yr. Future laser cooled clocks (Be(+), Rb, Cs, Hg(+), etc.), when compared, will yield the most sensitive of all tests for dot-alpha/alpha.

Prestage, John D.↗

Optical and infrared masers

Ongoing research progress in the following areas is described: (1) tunable infrared light sources and applications; (2) precision frequency and wavelength measurements in the infrared with applications to atomic clocks; (3) zero-degree pulse propagation in resonant medium; (4) observation of Dicke superradiance in optically pumped HF gas; (5) unidirectional laser amplifier with built-in isolator; and (6) progress in infrared metal-to-metal point contact tunneling diodes.

Source record↗

Shuttle experiment to demonstrate high-accuracy global time and frequency transfer

The concept of a high-accuracy global time and frequency transfer system is discussed. A hydrogen maser clock onboard a space vehicle combined with a microwave Doppler cancellation system can provide direct frequency transfer with an accuracy of 10 to the -14th and time transfer accurate to 1 ns. The addition of short pulse laser techniques provides subnanosecond time transfer accuracy which can be used to calibrate the microwave system.

Allan, D. W.↗