Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LHD DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experiments

In Large Helical Device (LHD) experiments, an electron temperature (T{sub e}) more than 15 keV has been observed by the yttrium-aluminum-garnet (YAG) laser Thomson scattering diagnostic. Since the LHD Thomson scattering system has been optimized for the temperature region, 50 eV{<=}T{sub e}{<=}10 keV, the data quality becomes worse in the higher T{sub e} region exceeding 10 keV. In order to accurately determine T{sub e} in the LHD high-T{sub e} experiments, we tried to increase the laser pulse energy by simultaneously firing three lasers. The technique enables us to decrease the uncertainties in the measured T{sub e}. Another signal accumulation method was also tested. In addition, we estimated the influence of high-energy electrons on T{sub e} obtained by the LHD Thomson scattering system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ion charge exchange spectroscopy adapted for tangential viewing geometry in LHD

A tangential Fast Ion Charge eXchange Spectroscopy is newly applied on a Large Helical Device (LHD) for co/countercirculating fast ions, which are produced by high energy tangential negative-ion based neutral beam injection. With this new observation geometry, both the tangential-neutral beam (NB) and a low-energy radial-NB based on positive ions can be utilized as probe beams of the measurement. We have successfully observed Doppler-shifted H-alpha lights due to the charge exchange process between the probing NB and circulating hydrogen ions of around 100 keV in LHD plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extension of high T{sub e} regime with upgraded ECRH system in the LHD

Enhancement of the output power per gyrotron has been planned in the Large Helical Device (LHD). Three 77-GHz gyrotrons with an output power of more than 1 MW have been operated. In addition, a high power gyrotron with the frequency of 154 GHz (1 MW/5 s, 0.5 MW/CW) was newly installed in 2012 and the total injection power of ECRH reached 4.6 MW. The operational regime of ECRH plasma on the LHD has been extended due to the upgraded ECRH system such as the central electron temperature T{sub e0} = 13.5 keV with n{sub e} = 1×10{sup 19}m{sup −3}. In the LHD, an electron-internal-transport barrier (e-ITB) related to the production of high T{sub e} plasmas has been realized by strongly centre-focused ECRH. The electron thermal confinement clearly improved inside the e-ITB. The radial electric field was measured using the heavy ion beam probe. The formation of the positive E{sub r} was observed in the core region, which well agreed with the prediction of the neoclassical transport theory. The energy confinement characteristics have been investigated in the ECRH plasmas. It was found that higher plasma stored energy and lower radiation power was realized in the outward configuration. The plasma stored energy of 530 kJ with n{sub e} = 3.2×10{sup 19}m{sup −3}, which is the 1.7 times larger than the previous record in the ECRH plasma in the LHD, has been successfully achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Z{sub eff} measurement using extreme ultraviolet bremsstrahlung emission in LHD

Radial profile measurement of Z{sub eff} using visible bremsstrahlung (5300 A) in the Large Helical Device (LHD) has often encountered difficulties because the intensity profile was largely deformed by the nonuniform visible bremsstrahlung emissions from the edge ergodic layer surrounding the core plasma. A space-resolved flat-field extreme ultraviolet (EUV) spectrometer has been newly adopted to measure the Z{sub eff} profile using the EUV bremsstrahlung continuum in the wavelength range of 70-75 A. The EUV bremsstrahlung intensity profiles have been measured and checked for all the magnetic configurations with totally different magnetic field structures in the ergodic layer of LHD. It is found that the nonuniform bremsstrahlung emission from the thick ergodic layer can be entirely eliminated by use of the EUV emission with relatively high photon energy of 170 eV. As a result, the Z{sub eff} profile can be successfully measured for most of discharges regardless of magnetic field structures of the ergodic layer. The Z{sub eff} profiles measured in the EUV range are compared with those measured in the visible range at a magnetic configuration with the thinnest ergodic layer thickness. The result verifies that the use of the EUV bremsstrahlung continuum is an alternative way for the Z{sub eff} measurement in toroidal plasmas with nonuniform bremsstrahlung emissions at the edge. Typical results from the EUV bremsstrahlung measurement are presented showing a fairly flat Z{sub eff} profile with error bars of {+-}14%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grating spectrometer system for beam emission spectroscopy diagnostics using high-energy negative-ion-based neutral beam injection on LHD

A beam emission spectroscopy (BES) system was developed for density gradient and fluctuation diagnostics in the Large Helical Device (LHD). In order to cover the large Doppler shift of the H{alpha} beam emission because of the high-energy negative-ion-based neutral beam atom (acceleration voltage V{sub acc}=90-170 kV) and the large motional Stark splitting due to the large vxB field (magnetic field B=3.0 T), a grating spectrometer was used instead of a conventional interference filter system. The reciprocal linear dispersion is about 2 nm/mm, which is sufficient to cover the motional Stark effect spectra using an optical fiber with a diameter of 1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of neutron spectrometer toward deuterium plasma diagnostics in LHD

Neutron spectrometer based on coincident counting of associated particles has been developed for deuterium plasma diagnostics on Large Helical Device (LHD) at the National Institute for Fusion Science. Efficient detection of 2.5 MeV neutron with high energy resolution would be achievable by coincident detection of a scattered neutron and a recoiled proton associated with an elastic scattering of incident neutron in a plastic scintillator as a radiator. The calculated neutron spectra from deuterium plasma heated by neutral beam injection indicate that the energy resolution of better than 7% is required for the spectrometer to evaluate energetic deuterium confinement. By using a prototype of the proposed spectrometer, the energy resolution of 6.3% and the detection efficiency of 3.3x10{sup -7} count/neutron were experimentally demonstrated for 2.5 MeV monoenergetic neutron, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ICRF Antenna Characteristics and Comparison with 3-D Code Calculation in the LHD

The plasma coupling characteristics and local heat spots of an ion cyclotron range of frequencies (ICRF) antenna in the Large Helical Device (LHD) are compared with the results of 3-D computing simulator code calculation. We studied several dependences of antenna loading resistances with plasma experimentally and observed a clear relation between the maximum injection power and the loading resistance. Realistic three-dimensional configuration of the ICRF antenna was taken into account to simulate the coupling characteristics and the local heat absorption near the ICRF antenna, which has a helically twisted geometry in the LHD. The electromagnetic field distribution and the current distribution on the antenna strap were calculated. We compared the RF absorption distribution on the antenna structure with the temperature rise during steady state operation and found that the temperature rise was well explained by comparing with the model simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collective Thomson scattering of a high power electron cyclotron resonance heating beam in LHD (invited)

Collective Thomson scattering (CTS) system has been constructed at LHD making use of the high power electron cyclotron resonance heating (ECRH) system in Large Helical Device (LHD). The necessary features for CTS, high power probing beams and receiving beams, both with well defined Gaussian profile and with the fine controllability, are endowed in the ECRH system. The 32 channel radiometer with sharp notch filter at the front end is attached to the ECRH system transmission line as a CTS receiver. The validation of the CTS signal is performed by scanning the scattering volume. A new method to separate the CTS signal from background electron cyclotron emission is developed and applied to derive the bulk and high energy ion components for several combinations of neutral beam heated plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Developments of scintillator-based soft x-ray diagnostic in LHD with CsI:Tl and P47 scintillators

Multi-channel soft x-ray (SX) diagnostic has been used in the large helical device (LHD) to research magnetohydrodynamic equilibria and activities. However, in the coming deuterium plasma experiments of LHD, it will be difficult to use semiconductor systems near LHD. Therefore, a new type of SX diagnostic, a scintillator-based type diagnostic, has been investigated in order to avoid damage from the radiation. A fiber optic plate coated by P47 scintillator will be used to detect SX emission. Scintillation light will be transferred by pure silica core optical fibers and detected by photomultiplier tubes. A vertically elongated section of LHD will be covered by a 13 ch. array. Effects from the Deuterium Deuterium neutrons can be negligible when the scintillator is covered by a Pb plate 4 cm in thickness to avoid gamma-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Rotational Transform on Thermal Transport in Stellarator–Heliotron Plasmas on LHD

Experimental evidence that indicates a positive effect of rotational transform on thermal transport has been shown for electron cyclotron heated plasmas on large helical device (LHD). Although this positive dependence was suggested by earlier scaling studies on energy confinement time, there was a concern that rotational transform is strongly correlated with another major non-dimensional parameter, that is, aspect ratio, in stellarator–heliotron systems. A careful experiment to exclude correlation between these two non-dimensional parameters was carried out on LHD by means of combining helical coil pitch control and limiter insertion. Plasmas with similar aspect ratio but different rotational transform have been compared in terms of global energy confinement time and local heat diffusivity. Energy confinement time increases with the rotational transform. Also the comparison of plasmas dimensionally similar in terms of normalized gyro-radius, collisionality, normalized pressure and aspect ratio has indicated that thermal transport improves with rotational transform. Since the plasmas studied here are dominated by turbulent transport rather than neoclassical transport, the identified feature, common to toroidal plasmas with tokamak, will stimulate the challenge to resolve the origin of the favorable effect of poloidal field and the compatibility with drift turbulence theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Internal disruptions and sawtooth like activity in Large Helical Device

Large Helical Device (LHD) inward-shifted configurations are unstable to resistive magnetohydrodynamic (MHD) pressure-gradient-driven modes. These modes drive sawtooth like events during LHD operation. In this work, we simulate sawtooth like activity and internal disruptions in order to improve the understanding of these relaxation events and their effect over the device efficiency to confine the plasma, with the aim to improve the LHD present and future operation scenarios minimizing or avoiding the disadvantageous MHD soft and hard limits. By solving a set of reduced non-linear resistive MHD equations, we have studied the evolution of perturbations to equilibria obtained before and after a sawtooth like event in LHD. The equilibrium {beta} value is gradually increased during the simulation until it reaches the experimental value. Sawtooth like events and internal disruption events take place in the simulation for {beta}{sub 0} values between 1% and 1.48%. The main driver of the sawtooth like events is the resonant and non-resonant effect of the (n = 1, m = 3) mode. The instability is stronger for resonant events, and they only appear when {beta}{sub 0} = 1.48%. Internal disruptions are mainly driven by the (n = 1, m = 2) mode, and they extend throughout the whole plasma core. Internal disruption events do not show up when resonant sawtooth like events are triggered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of CERC using newly installed 77 GHz Gyrotron in LHD

We have investigated the transition to Core Electron-Root Confinement (CERC) using the 77 GHz ECRH system, which was newly installed in the Large Helical Device (LHD). The focal point scan of the ECRH was carried out shot by shot in the same poloidal surface along the magnetic field of 2.75 T, which is the fundamental resonance surface for 77 GHz ECRH. The formation of the steep gradient in the electron temperature and the change of the radial electric field from negative to positive value in the plasma core region were observed by the ECRH injection to {rho}<0.5. The foot point of the peaked profile of the electron temperature appeared near the m/n = 2/1 rational surface, which was located at {rho}{approx}0.5. These results imply that localized ECRH in the inner region within the lower order rational surface and/or the electron heat flux across the rational surface play important roles for the transition to CERC. We also confirmed that the calculated radial electric field from a neoclassical theory qualitatively agreed with the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Activities on Realization of High-Power and Steady-State ECRH System and Achievement of High Performance Plasmas in LHD

Electron Cyclotron Resonance Heating (ECRH) has contributed to the achievement of high performance plasma production, high electron temperature plasmas and sustainment of steady-state plasmas in the Large Helical Device (LHD). Our immediate targets of upgrading the ECRH system are 5 MW several seconds and 1 MW longer than one hour power injection into LHD. The improvement will greatly extend the plasma parameter regime. For that purpose, we have been promoting the development and installation of 77 GHz/1-1.5 MW/several seconds and 0.3 MW/CW gyrotrons in collaboration with University of Tsukuba. The transmission lines are re-examined and improved for high and CW power transmission. In the recent experimental campaign, two 77 GHz gyrotrons were operated. One more gyrotron, which was designed for 1.5 MW/2 s output, was constructed and is tested. We have been promoting to improve total ECRH efficiency for efficient gyrotron-power use and efficient plasma heating, e.g. a new waveguide alignment method and mode-content analysis and the feedback control of the injection polarization. In the last experimental campaign, the 77 GHz gyrotrons were used in combination with the existing 84 GHz range and 168 GHz gyrotrons. Multi-frequency ECRH system is more flexible in plasma heating experiments and diagnostics. A lot of experiments have been performed in relation to high electron temperature plasmas by realization of the core electron-root confinement (CERC), electron cyclotron current drive (ECCD), Electron Bernstein Wave heating, and steady-state plasma sustainment. Some of the experimental results are briefly described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radial profile measurement of electron temperature in edge stochastic magnetic field layer of LHD using intensity ratio of extreme ultraviolet line emissions

Vertical profile of neon line emissions in 30-650 A wavelength range has been observed in horizontally elongated plasma cross section of Large Helical Device (LHD). Intensity ratio between the neon line emissions is studied to measure the radial profile of electron temperature in the edge stochastic magnetic field layer of LHD. The edge temperature profile successfully obtained from the line ratio of NeVIII 2s-3p to 2p-3s transitions is compared with the simulation based on three-dimensional edge transport code. The result shows a reasonably good agreement with the edge temperature profile analyzed from atomic data and analysis structure code. The electron temperature at last closed flux surface measured from the intensity ratio is also in good agreement with that measured from Thomson scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study on plasma edge boundary in ergodic layer of LHD based on radial profile measurement of impurity line emissions

Vertical profiles of edge impurity emissions have been measured in upper half region of elliptical plasmas at horizontally elongated plasma cross section in large helical device (LHD). The vertical profiles near upper O-point located just below helical coil are analyzed to study the plasma edge boundary of the ergodic layer consisting of stochastic magnetic field lines with connection lengths of 30 {<=} L{sub c} {<=} 2000 m. As a result, C{sup 3+} ion emitting CIV spectrum is identified as the ion existing in the farthest edge of the ergodic layer. The peak position of CIV (312.4 A: 1s{sup 2}3p {sup 2}P{sub 1/2,3/2}-1s{sup 2}2s {sup 2}S{sub 1/2}) vertical profile does not change at all in a wide temperature range of 150 {<=} T{sub e}({rho} = 1) {<=} 400 eV, whereas it moves inside the ergodic layer when T{sub e}({rho} = 1) is reduced below a threshold temperature, e.g., 130 eV at R{sub ax} = 3.75 m configuration. It is found that the C{sup 3+} ion exists at the boundary between ergodic layer and open magnetic filed layer at which the L{sub c} distributes in lengths of 5 to 30 m. The result indicates that the edge boundary near the O-point in LHD is determined by a starting point of the open filed layer, where a tokamak-like steeper edge temperature gradient is formed, although the edge boundary is quite obscure at the X-point region. Any plasma does not exist between the edge boundary and the vacuum vessel. The CIV profile at the O-point is simulated using a three-dimensional edge transport code of EMC3-EIRENE in which the magnetic field structure in vacuum is used for the ergodic layer. A clear discrepancy of 8 mm is found in the peak positions of CIV between measurement and simulation for magnetic configurations with thick ergodic layer, i.e., R{sub ax}=3.90 m, while only a small discrepancy of 3 mm is observed for those with relatively thin ergodic layer, i.e., R{sub ax} = 3.75 m. It suggests that the discrepancy is caused by a modification of the magnetic filed due to the presence of plasma pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modelling of Divertor Plasma Transport in Stochastic Magnetic Boundary

Impacts of stochastic magnetic field structure on divertor functions are discussed based on analyses with the three dimensional (3D) edge transport code package EMC3-EIRENE with Braginskii type fluid equations, in the Large Helical Device (LHD), in comparison with the experimental data. It is shown that the three dimensional field line topology introduced by the stochasticity provides controllability of the edge plasma transport such as divertor regime, impurity transport. The observations in other devices with stochastic magnetic boundary regarding these issues are discussed as well. Also presented are the traditional formulation of the magnetic field and the transport in the stochastic layer based on diffusive picture, which are contrasted with the 3D treatment of the flux tube topology and of the transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Objectives and layout of a high-resolution x-ray imaging crystal spectrometer for the large helical device

A high-resolution x-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for the large helical device (LHD). This instrument will record spatially resolved spectra of helium-like Ar{sup 16+} and will provide ion temperature profiles with spatial and temporal resolutions of <2 cm and {>=}10 ms, respectively. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neoclassical transport simulations for stellarators

The benchmarking of the thermal neoclassical transport coefficients is described using examples of the Large Helical Device (LHD) and TJ-II stellarators. The thermal coefficients are evaluated by energy convolution of the monoenergetic coefficients obtained by direct interpolation or neural network techniques from the databases precalculated by different codes. The temperature profiles are calculated by a predictive transport code from the energy balance equations with the ambipolar radial electric field estimated from a diffusion equation to guarantee a unique and smooth solution, although several solutions of the ambipolarity condition may exist when root-finding is invoked; the density profiles are fixed. The thermal transport coefficients as well as the ambipolar radial electric field are compared and very reasonable agreement is found for both configurations. Together with an additional W7-X case, these configurations represent very different degrees of neoclassical confinement at low collisionalities. The impact of the neoclassical optimization on the energy confinement time is evaluated and the confinement times for different devices predicted by transport modeling are compared with the standard scaling for stellarators. Finally, all configurations are scaled to the same volume for a direct comparison of the volume-averaged pressure and the neoclassical degree of optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗