Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

44 records · Page 3

Liquid Air Combined Cycle TM for Power and Storage

Liquid Air Combined Cycle (LACC) is a hybrid liquid air energy storage (LAES) system combining energy storage with a combustion turbine to enable large-scale, long-duration energy storage (LDES) while reducing fuel intensity compared to the current state-of-the-art. The LACC technical approach employs proven equipment (cryogenic refrigeration, storage, tanks, pumps, gas turbines, exhaust heat recovery equipment, and turbines) to limit technical risk to a novel organic Rankine cycle (ORC), which was evaluated during this project and found to be feasible. Moreover, LACC storage is safe and relatively compact, to facilitate siting close to loads and within metropolitan regions. The air storage medium is freely available and eliminates supply chain constraints. LACC uses cryogenic air as a storage medium and a gas turbine as the source of heat to drive the discharge process. LACC is distinguished from other LAES technologies by several factors. The charge and discharge processes are decoupled so that cryogenic liquid air is the only storage medium. Other systems also store the higher temperature thermal energy from the liquefaction process in an additional medium. Subsequently, LACC focuses on maximization of the discharge energy and power. LACC also permits the use of commercially available cryogenic refrigeration and storage technologies to increase competition. This project identified product requirements to support market entry and commercialization of the LACC in modular units of approximately 117 MW, each drawing liquid air from customary cryogenic storage tanks capable of storing 75 GWh of dispatchable energy, more than pumped storage hydro or compressed air energy storage technologies. An economic analysis identified the specific liquid air consumption (quantity of liquid air per unit of discharge energy) as a critical parameter. Minimizing the air consumption reduces the specific capital cost ($\$ $/kW) for charging and discharging equipment by reducing the size of piping and turbomachinery. Likewise, the specific cost of energy capacity ($\$ $/kWh) is reduced by increasing the energy deliverable from a given size tank. The cycle was analyzed to identify the optimal equipment selection and operating conditions, which in turn were combined with quotes and cost estimates to calculate the cost of energy from an LACC system. A substantial effort was focused on the ORC, which draws low-temperature heat from the gas turbine exhaust and condenses at low temperature using the cryogenic liquid air as a heat sink. Alternative turbomachinery arrangements were evaluated for feasibility and cost. A technology maturation plan lays out a low-risk approach to development of the novel ORC components and demonstration of LACC technology at pilot scale.

25 ENERGY STORAGE↗

An Ultra-Stable Reference Electrode as In-Situ System Diagnostics Tool for Redox Flow Batteries - CRADA 634 (Abstract)

The objective of the proposed project is to develop and demonstrate an ultra-stable reference electrode (RE) technology as an in-situ system diagnostics tool integrated in kW scaled commercial vanadium redox flow battery (VRFB) stacks for long-duration energy storage (LDES) applications and to advance its commercialization, with expected cell reliability enhancement in stack life increase of 6-10 % and levelized cost of storage (LCOS) reduction of 5-8 %. In this project, PNNL will partner with Stryten Energy LLC, with a total budget of $250K and 50% cost share for one year.

25 ENERGY STORAGE↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Durable Low-Cost Pressure Vessels for Bulk Hydrogen Storage

Long-duration energy storage (LDES) in the form of gaseous hydrogen is vital for fossil fuel power plants to reduce frequent shutdowns and rapid start-ups. It's also crucial in renewable energy power plants for grid stabilization. WireTough Cylinders (WTC) has developed a Type II-S pressure vessel that uses steel liners that are hoop-wrapped with multiple layers of high-strength, cost-effective, and readily available steel wires. This design enables the vessel to withstand significantly higher pressures. It addresses hydrogen embrittlement issues and cyclic loading from repeated pressurization and depressurization during service. The WireTough design is cost-efficient, robust, and fatigue-resistant (with a 30-year design life) and is ASME certified for ground storage of hydrogen at a maximum operating pressure (MOP) of 350 bar and a design pressure of 500 bar. The cylinder has a 645 mm outside diameter and a water capacity of 1,715 liters, capable of storing 40.7 KG of hydrogen at MOP. Two prototypes were successfully produced to showcase the manufacturing technologies, with one being certified under ASME Section VIII Division 3 rules. Preliminary design work for a similar Type II-S vessel with a 500 bar MOP was also completed. The 350 bar and 500 bar Type II-S vessels were shown respectively to be 47.5% to 60% more cost-effective and 55% and 62.5% lighter based on per KG of hydrogen stored, when compared with their Type 1 counterparts.

08 HYDROGEN↗

Achieving American Leadership in the Grid Storage Supply Chain Factsheet

To meet growing demand for long duration energy storage, domestic manufacturing will have to increase significantly. The use of renewables is rapidly increasing, and the adaption of electric vehicles is on the rise, which will require the national grid to not only produce and deliver electricity, but also store it reliably and cost-effectively. The International Energy Agency (IEA) recently released a report showing that to reach a goal of net-zero emissions by 2050, grid storage will need to grow to almost 2,500 gigawatt hours (GWh) in less than a decade. Currently, across the globe, battery technologies provide over 30 GWh of grid storage(BloombergNEF, 2020) while pumped storage hydropower (PSH)provides 160 gigawatts (GW) of long-duration energy storage (LDES) (PSH) (U.S. Department of Energy, 2020). This fact sheet summarizes strategies to address key vulnerabilities in the grid storage supply chain, the United States. These strategies include: • Developing domestic, sustainable manufacturing and recycling capabilities along the energy storage supply chain. • Maximizing the use of domestic resources by focusing on second-life and recycling technologies. • Enabling the diversification and deployment of grid storage technologies through targeted research activities. Addressing these opportunities will have significant impacts with respect to increasing well-paying skilled domestic jobs, improving the gross domestic product (GDP), and ensuring minimal environmental and climate impacts.

Source record↗

Ad-Mat: Adaptations of Mature Manufacturing Strategies for Accelerated Redox Flow Battery Deployment

The concept of the Ad-Mat approach is to leverage existing adjacent markets across a broad scope of technologies in order to reduce the manufacturing learning curve and ultimately accelerate redox flow battery (RFB) deployment at scale. Lithium-ion batteries (LIBs) are currently the dominant energy storage technology, and they came to technological maturity under unique market conditions when there was no meaningful competition in the consumer electronic and electric vehicle (EV) space. Today, alternative chemistries that may be technologically better-suited for long-duration storage applications are experiencing a high barrier to entry. This is in large part due to the substantial bias towards the scaled-up production and supply chain that now exists for LIBs. In the case of RFBs in particular, numerous analyses have suggested that RFBs should theoretically have a much lower system cost than LIBs - however, this relies on a mature and competitive manufacturing landscape, which has been extremely challenging to achieve for both flow batteries and other LIB competitors. At the moment, LIB alternatives tend to have isolated small-scale manufacturing pathways, which preclude the economies of scale that would be required to compete with the mature LIB industry. In the present state of the industry, niche manufacturing tools and approaches have evolved to support each alternative technology, such that there is substantial replication and duplication in effort. Continuing to pursue a strategy of isolated manufacturing processes/approaches for each LIB-alternative may never allow for at-scale deployment. In order for RFBs to meaningfully compete with LIBs in the realm of LDES, a new disruptive approach based on cross-industry learning and coordination is needed - and this is exactly what our Ad-Mat concept aims to tackle. In this re-envisioned manufacturing landscape, tools and processes from mature industries can be adapted and deployed across the range of alternative energy storage technologies. Adapting tools, equipment, processes, and industrial learning from mature industries to meet the technological requirements of RFBs would open new markets for existing OEMs in adjacent industries, would prevent unnecessary duplication and re-development, would improve efficiency across the manufacturing chain, and would ultimately support reduced costs and accelerated deployment of RFBs at scale.

adaptive manufacturing↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗