Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Magnetic dipole moments of {sup 58}Cu and {sup 59}Cu by in-source laser spectroscopy

Online measurements of the magnetic dipole moments and isotope shifts of {sup 58}Cu and {sup 59}Cu by the in-source laser spectroscopy method are reported. The results for the magnetic moments are {mu} ({sup 58}Cu) =+0.52(8) {mu}{sub N},{mu}({sup 59}Cu) =+1.84(3) {mu}{sub N} and for the isotope shifts {delta}{nu}{sup 59,65}=1.72(22) GHz and {delta}{nu}{sup 58,65}=1.99(30) GHz in the transition from the 3d{sup 10}4s {sup 2}S{sub 1/2} ground state to the 3d{sup 10}4p {sup 2}P{sub 1/2} state in Cu I. The magnetic moment of {sup 58}Cu is discussed in the context of the strength of the subshell closure at {sup 56}Ni, additivity rules and large-scale shell model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser spectroscopy of trapped short-lived Ra{sup +} ions

As an important step toward an atomic parity violation experiment in one single trapped Ra{sup +} ion, laser spectroscopy on short-lived {sup 212,213,214}Ra{sup +} ions was conducted. The isotope shift of the 6 {sup 2}D{sub 3/2}-7 {sup 2}P{sub 1/2} and 6 {sup 2}D{sub 3/2}-7 {sup 2}P{sub 3/2} transitions and the hyperfine structure constants of the 7 {sup 2}P{sub 1/2} and 6 {sup 2}D{sub 3/2} states in {sup 213}Ra{sup +} were measured, which provides a benchmark for the required atomic theory. A lower limit of 232(4) ms for 6 {sup 2}D{sub 5/2} state lifetime was determined.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser Spectroscopy Multi-Gas Monitor: Results of Technology Demonstration on ISS

Tunable diode laser spectroscopy (TDLS) is an up and coming trace and major gas monitoring technology with unmatched selectivity, range and stability. The technology demonstration of the 4 gas Multi-Gas Monitor (MGM), reported at the 2014 ICES conference, operated continuously on the International Space Station (ISS) for nearly a year. The MGM is designed to measure oxygen, carbon dioxide, ammonia and water vapor in ambient cabin air in a low power, relatively compact device. While on board, the MGM experienced a number of challenges, unplanned and planned, including a test of the ammonia channel using a commercial medical ammonia inhalant. Data from the unit was downlinked once per week and compared with other analytical resources on board, notably the Major Constituent Analyzer (MCA), a magnetic sector mass spectrometer. MGM spent the majority of the time installed in the Nanoracks Frame 2 payload facility in front breathing mode (sampling the ambient environment of the Japanese Experiment Module), but was also used to analyze recirculated rack air. The capability of the MGM to be operated in portable mode (via internal rechargeable lithium ion polymer batteries or by plugging into any Express Rack 28VDC connector) was a part of the usability demonstration. Results to date show unprecedented stability and accuracy of the MGM vs. the MCA for oxygen and carbon dioxide. The ammonia challenge (approx. 75 ppm) was successful as well, showing very rapid response time in both directions. Work on an expansion of capability in a next generation MGM has just begun. Combustion products and hydrazine are being added to the measurable target analytes. An 8 to 10 gas monitor (aka Gas Tricorder 1.0) is envisioned for use on ISS, Orion and Exploration missions.

Mudgett, Paul D.↗

Laser Spectroscopy at On-Line Isotope Separators

Optical hyperfine structures and isotope shifts of radioactive atoms and ions can be measured at ISOL facilities with high precision and sensitivity using a variety of laser spectroscopic techniques. The analysis of these structures and shifts provides information on some of the most fundamental properties of nuclear ground states and isomeric states, namely the magnetic dipole and electric quadrupole moments, the nuclear spin, and the difference in the nuclear mean square charge radius between isotopes. The status of current experimental programmes at ISOL facilities will be reviewed. The techniques employed include in-source, collinear-beams, atom-trap, and cooler-buncher laser spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and Calibration of a Raman Spectrometer for use in a Laser Spectroscopy Instrument Intended to Analyze Martian Surface and Atmospheric Characteristics for NASA

This project's goal is the design of a Raman spectroscopy instrument to be utilized by NASA in an integrated spectroscopy strategy that will include Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Induced Florescence Spectroscopy (LIFS) for molecule and element identification on Mars Europa, and various asteroids. The instrument is to be down scaled from a dedicated rover mounted instrument into a compact unit with the same capabilities and accuracy as the larger instrument. The focus for this design is a spectrometer that utilizes Raman spectroscopy. The spectrometer has a calculated range of 218 nm wavelength spectrum with a resolution of 1.23 nm. To filter out the laser source wavelength of 532 nm the spectrometer design utilizes a 532 nm wavelength dichroic mirror and a 532 nm wavelength notch filter. The remaining scatter signal is concentrated by a 20 x microscopic objective through a 25-micron vertical slit into a 5mm diameter, 1cm focal length double concave focusing lens. The light is then diffracted by a 1600 Lines per Millimeter (L/mm) dual holographic transmission grating. This spectrum signal is captured by a 1-inch diameter double convex 3 cm focal length capture lens. An Intensified Charge Couple Device (ICCD) is placed within the initial focal cone of the capture lens and the Raman signal captured is to be analyzed through spectroscopy imaging software. This combination allows for accurate Raman spectroscopy to be achieved. The components for the spectrometer have been bench tested in a series of prototype developments based on theoretical calculations, alignment, and scaling strategies. The mounting platform is 2.5 cm wide by 8.8 cm long by 7 cm height. This platform has been tested and calibrated with various sources such as a neon light source and ruby crystal. This platform is intended to be enclosed in a ruggedized enclosure for mounting on a rover platform. The size and functionality of the Raman spectrometer allows for the rover to carry other mission critical devices. This project will be continued at NASA until the requirements are met for the expected initial 2020 launch date.

Lucas, John F.↗

Selective laser spectroscopy of SrF{sub 2} crystal doped with Pr{sup 3+} ions

SrF{sub 2} crystals doped with Pr{sup 3+} ions with concentrations corresponding to 0.5, 1.0 and 2.0 wt % of PrF{sub 3} are studied by selective laser excitation. The absorption and luminescence spectra of Pr{sub 3} ions are measured at a temperature of 77 K. Three types of tetragonal centres (C, E, S) with the point symmetry group C{sub 4v} and three types of cluster centres (K{sub 1}, K{sub 2}, K{sub 3}) are found. Energy level diagrams of the {sup 3}H{sub 4}, {sup 3}P{sub 1} and {sup 3}P{sub 2} terms of Pr{sup 3+} ions in SrF{sub 2} crystals are plotted for the tetragonal (C) and cluster optical centres. The lifetimes of the tetragonal C centre [τ(300 K) ∼ 112 μs, τ(77 K) ∼108 μs] and cluster centres K{sub 1} (∼43 μs), K{sub 2} (∼7 μs) and K{sub 3} (∼48 μs) are measured at 77 K for the first time. (laser spectroscopy)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laboratory diode laser spectroscopy in molecular planetary astronomy

Infrared spectroscopy of planetary atmospheres is performed at high spectral resolution comparable to that in the laboratory. This requires that laboratory spectroscopy use the highest resolution and the most accurate techniques. Tunable diode laser spectroscopy can supply many of the spectroscopic parameters needed by astronomers. In particular, line positions, line strengths, and collisional line widths are measured with diode lasers, and these are often among the best values available. Diode laser spectra are complimentary to lower resolution, broader-coverage Fourier transform spectra. Certain procedures must be adopted, however, when using diode lasers, for determining their output characteristics and for calibrating each spectrum against quality references.

Jennings, D. E.↗

Stratospheric composition measurements of earth and Titan using high-resolution tunable diode laser spectroscopy

Field and laboratory measurements of species of atmospheric interest made as part of the JPL diode laser spectroscopy program are presented. Stratospheric measurements of NO2, NO, CO2, and H2O made in November 1985 using the BLISS instrument are reported, together with recent laboratory measurements of spectral line parameters of HNO3 and HO2NO2. In addition, a novel diode laser instrument concept for the in situ sensing of Titan's atmosphere is described for the Saturn Orbiter/Titan Probe (SOTP) Cassini Mission.

Webster, Christopher R.↗

Xe{sub 2} gerade Rydberg states observed in the afterglow of a microplasma by laser spectroscopy of a{sup 3}Σ{sub u}{sup +}(1{sub u},O{sub u}{sup −}) absorption in the green (545–555 nm) and near-infrared (675–800 nm)

Bound←bound transitions of the Xe dimer at small internuclear separation (R < 4.0 Å) have been observed in the 545–555 nm and 675–800 nm spectral regions by laser spectroscopy in the afterglow of a pulsed Xe microplasma with a volume of ∼160 nl. Transient suppression of Xe{sub 2} A{sup 1}Σ{sub u}{sup +}(O{sub u}{sup +})→X{sup 1}Σ{sub g}{sup +}(O{sub g}{sup +}) emission in the vacuum ultraviolet (∼172 nm), induced by laser excitation of Ω{sub g}←a{sup 3}Σ{sub u}{sup +}(1{sub u},O{sub u}{sup −}) [Rydberg←Rydberg] transitions of the molecule, has confirmed the existence of structure between 720 and 770 nm (reported by Killeen and Eden [J. Chem. Phys. 84, 6048 (1986)]) but also reveals red-degraded vibrational bands extending to wavelengths beyond 800 nm. Spectral simulations based on calculations of Franck-Condon factors for assumed Ω{sub g}←a{sup 3}Σ{sub u}{sup +} transitions involving Ω = 0{sup ±},1 gerade Rydberg states suggest that the upper level primarily responsible for the observed spectrum is an Ω = 1 state correlated, in the separated atom limit, with Xe(5p{sup 6} {sup 1}S{sub 0}) + Xe(5p{sup 5} 6p) and built on a predominantly A{sup 2}Π{sub 3/2g} molecular ion core. Specifically, the spectroscopic constants for the upper state of the 1{sub g}←1{sub u},O{sub u}{sup ±} absorptive transitions are determined to be T{sub e} = 13 000 ± 150 cm{sup −1}, ω{sub e}{sup ′}=120±10 cm{sup −1}, ω{sub e}{sup ′}x{sub e}{sup ′}=1.1±0.4 cm{sup −1}, D{sub e} = 3300 ± 300 cm{sup −1}, and ΔR{sub e}=R{sub e}{sup ′}−R{sub e}{sup ″}=0.3±0.1 Å which are in general agreement with the theoretical predictions of the pseudopotential hole-particle formalism, developed by Jonin and Spiegelmann [J. Chem. Phys. 117, 3059 (2002)], for both the (5)1{sub g} and (3)O{sub g}{sup +} states of Xe{sub 2}. These spectra exhibit the most extensive vibrational development, and provide evidence for the first molecular core-switching transition, observed to date for any of the rare gas dimers at small R (<4 Ǻ). Experiments in the green (545–555 nm) also provide improved absorption spectra, relative to data reported in 1986 and 1999, associated with Xe{sub 2} Rydberg states derived from the Xe(7p) orbital.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oxygen Spectroscopy Laser Sounding Instrument for Remote Sensing of Atmospheric Pressure

We report on the progress of an Oxygen spectroscopy laser sounding instrument designed as a calibration channel for a carbon dioxide (CO2) laser sounding instrument. We have developed a pulsed, frequency-doubled, fiber laser transmitter for use in an oxygen instrument. The instrument concept uses the pressure broadening of spectroscopic lines of the diatomic oxygen A-band to deduce atmospheric pressure. There are many uses for this measurement but we are developing it primarily to make a measurement of the dry mixing ratio of CO2. The CO2 measurement can be affected by changes in atmospheric properties such as humidity, temperature and pressure. To remove these variances requires measuring a stable, well-mixed gas like Oxygen. We will report on the basic theory behind the instrument, measurements made at a test site at Goddard, review the current state of the instrument technologies and the necessary steps to bring them to space readiness, and review the current state of the instrument development.

Stephen Mark A.↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Raman-laser spectroscopy of Wannier-Stark states

Raman lasers are used as a spectroscopic probe of the state of atoms confined in a shallow one-dimensional (1D) vertical lattice. For sufficiently long laser pulses, resolved transitions in the bottom band of the lattice between Wannier Stark states corresponding to neighboring wells are observed. Couplings between such states are measured as a function of the lattice laser intensity and compared to theoretical predictions, from which the lattice depth can be extracted. Limits to the linewidth of these transitions are investigated. Transitions to higher bands can also be induced, as well as between transverse states for tilted Raman beams. All these features allow for a precise characterization of the trapping potential and for an efficient control of the atomic external degrees of freedom.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-resolution laser spectroscopy between 0.9 and 14.3 THz in a supersonic beam: Rydberg-Rydberg transitions of atomic Xe at intermediate n values

A laser-based, pulsed, narrow-band source of submillimeter-wave radiation has been developed that is continuously tunable from 0.1 THz to 14.3 THz. The source is based on difference-frequency mixing in the nonlinear crystal trans-4{sup Prime }-(dimethylamino)-N-methyl-4-stilbazolium tosylate. By varying the pulse length, the bandwidth of the submillimeter-wave radiation can be adjusted between 85 MHz and 2.8 MHz. This new radiation source has been integrated in a vacuum-ultraviolet-submillimeter-ware double-resonance spectrometer, with which low-frequency transitions of atoms and molecules in supersonic beams can be detected mass-selectively by photoionization and time-of-flight mass spectrometry. The properties of the radiation source and spectrometer are demonstrated in a study of 33f Leftwards-Arrow nd Rydberg-Rydberg transitions in Xe with n in the range 16-31. The frequency calibration of the submillimeter-wave radiation was performed with an accuracy of 2.8 MHz. The narrowest lines observed experimentally have a full-width at half-maximum of {approx}3 MHz, which is sufficient to fully resolve the hyperfine structure of the Rydberg-Rydberg transitions of {sup 129}Xe and {sup 131}Xe. A total of 72 transitions were measured in the range between 0.937 THz and 14.245 THz and their frequencies are compared with frequencies calculated by multichannel quantum defect theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser spectroscopy of the 4s4p {sup 3}P{sub 2} - 4s3d {sup 1}D{sub 2} transition on magnetically trapped calcium atoms

Laser excitation of the 4s4p {sup 3}P{sub 2} - 4s3d {sup 1}D{sub 2} transition in atomic calcium has been observed and the wavelength determined to 1530.5298(6) nm. The metastable 4s4p {sup 3}P{sub 2} atoms were magnetically trapped in the quadrupole magnetic field of a magneto-optical trap. This state represents the only ''loss'' channel for the calcium atoms when laser cooled on the 4s{sup 2} {sup 1}S{sub 0} - 4s4p {sup 1}P{sub 1} transition. A rate equation model shows that an order of magnitude more atoms are trapped in this state compared with those taking part in the main cooling cycle. Excitation of the {sup 3}P{sub 2} atoms back up to the 4s3d {sup 1}D{sub 2} state provides a means of accessing these atoms. Efficient repumping is achieved if the 1530-nm laser is used in conjunction with a 672-nm laser driving the 4s3d {sup 1}D{sub 2} - 4s5p {sup 1}P{sub 1} transition. In the present experiment, we detected about 4.5x10{sup 4} trapped {sup 3}P{sub 2} atoms, a relatively low atom density, and measured a lifetime of approximately 1 s, which is limited by background collisions.

74 ATOMIC AND MOLECULAR PHYSICS↗

In-gas-jet laser spectroscopy with S 3 -LEB

The Super Separator Spectrometer-Low Energy Branch (S 3 -LEB) is a low-energy radioactive ion beam experiment under commissioning as part of the GANIL-SPIRAL2 facility. It will be used for the production and study of exotic nuclei by in-gas laser ionization and spectroscopy (IGLIS), decay spectroscopy, and mass spectrometry. Here, we report recent results from the off-line commissioning of S 3 -LEB, including first laser spectroscopy measurements in both the gas cell and the supersonic gas jet, the determination of the transport efficiency of laser ions from the gas cell through the RFQ chain, and time-of-flight measurements with the multi-reflection time-of-flight mass spectrometer PILGRIM. The measurements were performed using erbium, introduced by evaporation from a heated filament in the gas environment. The reported laser spectroscopy results include a characterization of the pressure broadening in the gas cell, proof-of-principle isotope shift measurements, and hyperfine-structure measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of silicon-carbon clusters by infrared laser spectroscopy. The nu 1 band of SiC4

The nu 1 fundamental vibration of linear SiC4 has been observed by infrared diode laser spectroscopy of a supersonic cluster beam. Twenty-four rovibrational transitions were measured in the spectral region of 2094.6 to 2097.1 cm-1, the rotational temperature was 10 K. A combined least-squares fit of these transitions with previously reported microwave data yielded the following molecular constants: nu 1 = 2095.45806(37) cm-1, B" = 0.051161131(52) cm-1, and B' = 0.0509157(96) cm-1. These results are compared to vibrational spectroscopy measurements of SiC4 trapped in a solid Ar matrix and to ab initio calculations.

NASA Discipline Exobiology↗

Laser spectroscopy of indium Rydberg atom bunches by electric field ionization

This work reports on the application of a novel electric field-ionization setup for high-resolution laser spectroscopy measurements on bunched fast atomic beams in a collinear geometry. In combination with multi-step resonant excitation to Rydberg states using pulsed lasers, the field ionization technique demonstrates increased sensitivity for isotope separation and measurement of atomic parameters over previous non-resonant laser ionization methods. The setup was tested at the Collinear Resonance Ionization Spectroscopy experiment at ISOLDE-CERN to perform high-resolution measurements of transitions in the indium atom from the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states to 5s 2 np 2 P and 5s 2 nf 2 F Rydberg states, up to a principal quantum number of n=72 . The extracted Rydberg level energies were used to re-evaluate the ionization potential of the indium atom to be 46,670.107(4)cm -1 . The nuclear magnetic dipole and nuclear electric quadrupole hyperfine structure constants and level isotope shifts of the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states were determined for 113,115 In. The results are compared to calculations using relativistic coupled-cluster theory. A good agreement is found with the ionization potential and isotope shifts, while disagreement of hyperfine structure constants indicates an increased importance of electron correlations in these excited atomic states. With the aim of further increasing the detection sensitivity for measurements on exotic isotopes, a systematic study of the field-ionization arrangement implemented in the work was performed at the same time and an improved design was simulated and is presented. The improved design offers increased background suppression independent of the distance from field ionization to ion detection.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simultaneous solution-based generation and characterization of crystalline bismuth thin film by femtosecond laser spectroscopy

We demonstrate generation and characterization of crystalline bismuth thin film from triphenyl bismuth in methanol. Upon ultraviolet (267 nm) femtosecond laser irradiation of the solution, a thin film of elemental bismuth forms on the inner side of the sample cuvette, confirmed by detection of the coherent A{sub 1g} optical phonon mode of crystalline bismuth at ∼90 cm{sup −1}. Probe pulses at 267 and 400 nm are used to elucidate the excited state potential energy surface and photochemical reaction coordinate of triphenyl bismuth in solution with femtosecond resolution. The observed phonon mode blueshifts with increasing irradiation time, likely due to the gradual thickening of nascent bismuth thin film to ∼80 nm in 90 min. From transient absorption with the 400 nm probe, we observe a dominant ∼4 ps decay time constant of the excited-state absorption signal, which is attributed to a characteristic metal-ligand bond-weakening/breaking intermediate enroute to crystalline metallic thin film from the solution precursor molecules. Our versatile optical setup thus opens an appealing avenue to characterize the laser-induced crystallization process in situ and prepare high-quality thin films and nanopatterns directly from solution phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗