Engineering PapersSearch

SEARCH · Engineering Papers

Results for “LASER MODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development and applications of optical interferometric micrometrology in the angstrom and subangstrom range

The recent development of the scanning electron tunneling microscope and the atomic force microscope requires absolute standards for measurements in the angstrom and subangstrom range. Optical interferometry with lasers and multiple mode laser resonances can provide absolute measurements as the laser wavelengths are very accurately known. A key feature of such measurements is the use of piezoelectric crystals as translators of the highest accuracy for very small disturbances. However, the dimensional changes of these crystals resulting from electrical potential changes depend on many variables, among them the method of mounting, so that accurate calibrations are necessary. Starting from advances in optical metrology made by physicists trying to find gravity waves, advances which led to measurements down to 10 to the -5 A, the author designed and built a much simpler system for the angstrom range. The major limiting factors were mechanical vibrations, air currents, thermal changes and laser instabilities.

Lauer, James L.

Q-switched, cavity-dumped, mode-locked laser

Continuous-wave laser can achieve higher rate of emission through Q-switching. Technique keeps Q, energy storage rating, of laser cavity at low value while ion population inversion is being built up. Then Q is suddenly switched to high value just before instability occurs.

Fountain, W.

Single mode CO2 laser frequency modulation up to 350 MHz

Experiments on internal frequency modulation (FM) of a CO2 laser showed no limitation of FM by the linewidth. However, distortions in the form of strong enhancement of sideband amplitude arise for frequencies equal to the cavity resonant frequencies, most pronounced if the modulator is positioned near a cavity mirror.

Leeb, W. R.

Studies of single-mode injection lasers and of quaternary materials. Volume 2: Measurement of electro-optic effects in InGaAsP junction waveguides

Both the linear electro-optic (Pockel's) effect and electroabsorption (Franz-Keldysh effect) in waveguiding junctions of InGaAsP were measured. The electro-optic coefficient is found to be 0.1-0.14x10 to the -12 power m/V at lambda = 1.54 - 1.65 micrometers. Possibly this is the first reported measurement of the electro-optic coefficient for InGaAsP. The value found for the electroabsorption is on the order of 7x10 to the -4 power cm to the -1 power/(V/cm) or approximately 100 cm/1 for fields of 200,000 V/cm at lambda 1.3 micrometers. All measurements were made on a quaternary film with a bandgap wavelength of 1.23 micrometers. Because of the rapid commercial introduction of quaternary lasers, LEDs, and detectors to take advantage of large optical fiber bandwidths and low losses in the 1.2- to 1.7- micrometer region, these measurements are significant in providing some of the basic physical constants needed to design modulators and switches capable of operating at microwave frequencies in this wavelength region.

Hammer, J. M.

Monolithic Isolated Single-Mode Ring Laser

MISER uses four-sided ring to lase nonreciprocally. Laser concept provides very-compact, efficient, and stable source of coherent radiation. Lasers of single, very-stable frequency desirable for number of purposes. Frequency stability makes possible coherent detection of laser radiation with low-bandwidth detector, useful for communications. Allows very-high-resolution spectroscopy. Any application where desired to use laser in way microwaves used traditionally enhanced if frequency very stable.

Kane, T. J.

A Compact, Solid-State UV (266 nm) Laser System Capable of Burst-Mode Operation for Laser Ablation Desorption Processing

Compared to wet chemistry and pyrolysis techniques, in situ laser-based methods of chemical analysis provide an ideal way to characterize precious planetary materials without requiring extensive sample processing. In particular, laser desorption and ablation techniques allow for rapid, reproducible and robust data acquisition over a wide mass range, plus: Quantitative, spatially-resolved measurements of elemental and molecular (organic and inorganic) abundances; Low analytical blanks and limits-of-detection ( ng g-1); and, the destruction of minimal quantities of sample ( g) compared to traditional solution and/or pyrolysis analyses (mg).

Laser

Phase Noise Reduction of Laser Diode

Phase noise of single mode laser diodes, either free-running or using line narrowing technique at room temperature, namely injection-locking, has been investigated. It is shown that free-running diodes exhibit very large excess phase noise, typically more than 80 dB above shot-noise at 10 MHz, which can be significantly reduced by the above-mentioned technique.

Zhang, T. C.

Theory of a high-intensity gas laser

Single mode gas laser theory for arbitrary field intensities in terms of ensemble averaged form of density-matrix equations of motion

Feld, M. S.

Precluding nonlinear ISI in direct detection long-haul fiber optic systems

Long-distance, high-rate fiber optic systems employing directly modulated 1.55-micron single-mode lasers and conventional single-mode fiber suffer severe intersymbol interference (ISI) with a large nonlinear component. A method of reducing the nonlinearity of the ISI, thereby making linear equalization more viable, is investigated. It is shown that the degree of nonlinearity is highly dependent on the choice of laser bias current, and that in some cases the ISI nonlinearity can be significantly reduced by biasing the laser substantially above threshold. Simulation results predict that an increase in signal-to-nonlinear-distortion ratio as high as 25 dB can be achieved for synchronously spaced samples at an optimal sampling phase by increasing the bias current from 1.2 times threshold to 3.5 times threshold. The high SDR indicates that a linear tapped delay line equalizer could be used to mitigate ISI. Furthermore, the shape of the pulse response suggests that partial response precoding and digital feedback equalization would be particularly effective for this channel.

Swenson, Norman L.

Synchronously pumped mode-locked Ti:Al2O3 lasers

Synchronously pumped mode-locked laser operation in a Ti:Al2O3 ring laser is demonstrated. The laser pump source was a frequency-doubled Nd:YAG laser-amplifier system producing a 60-micron-long macropulse that comprised a wavetrain of mode-locked 70-ps micropulses with a 10-ns spacing (100 MHz). The Ti:Al2O3 laser consisted of a 1-cm-long crystal with faces cut at the Brewster angle and placed in a ring laser cavity configuration with a 2 percent output coupling mirror. The cavity was adjusted for a 5-ns round trip transit time, which was close to half the temporal spacing of the pump pulse. When the crystal was pumped synchronously at 532 nm with a 30-mJ macropulse, which was approximately an order of magnitude above the laser threshold, mode-locked lasing at approximately 200 MHz was obtained. This macropulse pump energy corresponds to an average micropulse pump energy of about 5 microJ at the Ti:Al2O3 crystal face. The mode-locked operation of the Ti:Al2O3 was observed only after several microseconds into the macropulse, indicating a long build-up process over many cavity trips. During this time, relaxation oscillations were observed. When mode locking started, the relaxation oscillation frequency increased by an order of magnitude. Synchronous pumping has been limited to operation with dye lasers and used either a CW or pulsed mode-locked pump source. Recent work has demonstrated CW mode-locked operation of a Ti:Al2O3 laser. The result raises the possibility that pulsed synchronous pumping may be used to obtain significantly narrowed laser pulses in Ti:Al2O3.

Source record

Diffractive Combiner of Single-Mode Pump Laser-Diode Beams

An optical beam combiner now under development would make it possible to use the outputs of multiple single-mode laser diodes to pump a neodymium: yttrium aluminum garnet (Nd:YAG) nonplanar ring oscillator (NPRO) laser while ensuring that the laser operates at only a single desired frequency. Heretofore, an Nd:YAG NPRO like the present one has been pumped by a single multimode laser-diode beam delivered via an optical fiber. It would be desirable to use multiple pump laser diodes to increase reliability beyond that obtainable from a single pump laser diode. However, as explained below, simplistically coupling multiple multimode laser-diode beams through a fiber-optic combiner would entail a significant reduction in coupling efficiency, and lasing would occur at one or more other frequencies in addition to the single desired frequency. Figure 1 schematically illustrates the principle of operation of a laser-diode-pumped Nd:YAG NPRO. The laser beam path is confined in a Nd:YAG crystal by means of total internal reflections on the three back facets and a partial-reflection coating on the front facet. The wavelength of the pump beam - 808 nm - is the wavelength most strongly absorbed by the Nd:YAG crystal. The crystal can lase at a wavelength of either 1,064 nm or 1,319 nm - which one depending on the optical coating on the front facet. A thermal lens effect induced by the pump beam enables stable lasing in the lowest-order transverse electromagnetic mode (the TEM00 mode). The frequency of this laser is very stable because of the mechanical stability of the laser crystal and the unidirectional nature of the lasing. The unidirectionality is a result of the combined effects of (1) a Faraday rotation induced by an externally applied magnetic field and (2) polarization associated with non-normal incidence and reflection on the front facet.

Liu, Duncan