Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LARMOR PRECESSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

49 records · Page 3

A Flaring Magnetar in FRB 121102?

The persistent radio counterpart of fast radio burst (FRB) 121102 is estimated to have N∼10{sup 52} particles, energy E{sub N}∼10{sup 48} erg, and size R∼10{sup 17} cm. The source can be nebula inflated and heated by an intermittent outflow from a magnetar—a neutron star powered by its magnetic (rather than rotational) energy. The object is young and frequently liberating energy in magnetic flares driven by accelerated ambipolar diffusion in the neutron star core, feeding the nebula and producing bright millisecond bursts. The particle number in the nebula is consistent with ion ejecta from giant flares. The nebula may also contain the freeze-out of electron–positron pairs N{sub ±}∼10{sup 51} created months after the neutron star birth; the same mechanism offers an explanation for N{sub ±} in the Crab Nebula. The persistent source around FRB 121102 is likely heated by magnetic dissipation and internal waves excited by the magnetar ejecta. The volumetric heating by waves explains the nebula’s enormous efficiency in producing radio emission. The repeating radio bursts are suggested to occur much closer to the magnetar, as a result of ultrarelativistic internal shocks in the magnetar wind, which are launched by the magnetospheric flares. The shocks are mediated by Larmor rotation, which forms a GHz maser with the observed ms duration. Furthermore, the flare ejecta can become charge-starved and then convert to electromagnetic waves.

79 ASTRONOMY AND ASTROPHYSICS↗

The Magsat scalar magnetometer

The Magsat scalar magnetometer is derived from optical pumping magnetometers flown on the orbiting geophysical observatories. The basic sensor, a cross-coupled arrangement of absorption cells, photodiodes, and amplifiers, oscillates at the Larmor frequency of atomic moments precessing about the ambient field direction. The Larmor frequency output is accumulated digitally and stored for transfer to the spacecraft telemetry stream. In orbit the instrument has met its principal objective of calibrating the vector magnetometer and providing scalar field data.

Farthing, W. H.↗

Search for an axion-induced oscillating electric dipole moment for electrons using atomic magnetometers

We propose an experimental search for an axion-induced oscillating electric dipole moment (OEDM) for electrons using state-of-the-art alkali vapor-cell atomic magnetometers. The axion is a hypothesized new fundamental particle which can resolve the strong charge-parity problem and be a prominent dark matter candidate. This experiment utilizes an atomic magnetometer as both a source of optically polarized electron spins and a magnetic-field sensor. The interaction of the axion field, oscillating at a frequency equal to the axion mass, with an electron spin induces a sizable OEDM of the electron at the same frequency as the axion field. When the alkali vapor is subjected to an electric field and a magnetic field, the electron OEDM interacts with the electric field, resulting in an electron spin precession at the spin’s Larmor frequency in the magnetic field. The resulting precession signal can be sensitively detected with a probe laser beam of the atomic magnetometer. We estimate that the experiment is sensitive to the axion-photon interaction in ultralight axion masses from 10 -15 to 10 -10 eV. It is able to improve the current experimental limit up to 5 orders of magnitude, exploring new axion parameter spaces.

74 ATOMIC AND MOLECULAR PHYSICS↗

Coherent spin dynamics in nanopatterned ferromagnet-semiconductor hybrids at room-temperature

We used time-resolved Kerr rotation to study the coherent spin dynamics of electrons in Py-GaAs hybrid structures up to room temperature. The geometry of the nanopatterned Py wires was varied in a wide range to modify the fringe field from the ferromagnets and thus the Larmor frequency of the precessing electron spins compared to a reference. At room temperature, the observed fringe field effect is in good agreement with theory while at low temperatures additional strain effects occur.

36 MATERIALS SCIENCE↗

New capabilities in high-resolution neutron Larmor diffraction at ORNL

Using superconducting magnetic Wollaston prisms, high-resolution neutron Larmor diffraction has been implemented at the High-Flux Isotope Reactor of Oak Ridge National Laboratory (ORNL), Tennesse, USA. This technique allows the inverse relationship between the achievable diffraction resolution and the usable neutron flux to be overcome. Instead of employing physically tilted radio-frequency spin flippers, the method uses magnetic Wollaston prisms which are electromagnetically tuned by changing the field configurations in the device. As implemented, this method can be used to measure lattice-spacing changes induced, for example, by thermal expansion or strain with a resolution of Δd/d ≃ 10 –6 , and the splitting of sharp Bragg peaks with a resolution of Δd/d = 3 × 10 –4 . The resolution for discerning a change in the profile of a Bragg peak is Δd/d < 10 –5 . This is a remarkable degree of precision for a neutron diffractometer as compact as the one used in this implementation. Higher precision could be obtained by implementing this technique in an instrument with a larger footprint. In conclusion, the availability of this technique will provide an alternative when standard neutron diffraction methods fail and will greatly benefit the scientific communities that require high-resolution diffraction measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The muon g-2 experiment at Fermilab

The E989 collaboration has recently published the most precise measurement of the muon anomalous magnetic moment $a_\mu$ with an uncertainty of $0.46\,\mathrm{ppm}$. The new experimental world average of $a_\mu$ deviates by 4.2 standard deviations from the Standard Model prediction provided by the Muon g-2 Theory Initiative. Emerging results from ab-initio lattice QCD calculations for hadron-physics contributions allow to scrutinize this tantalizing hint for physics beyond the Standard Model for the first time in a three way comparison. To extract the value of $a_\mu$ a frequency comparison experiment is performed with spin-polarized muons confined in a superbly controlled electric and magnetic field environment. A measurement of the difference between the Larmor and the cyclotron frequency, the so-called anomalous spin precession frequency, is combined with a high-precision measurement of the magnetic field environment which is performed using nuclear magnetic resonance techniques. I discussed the most recent result of the Fermilab Muon g-2 experiment's first physics data run performed in 2018. I reported on the experimental improvements implemented for the subsequent science runs that will allow the collaboration to achieve the ultimate goal of $0.14\,\mathrm{ppm}$ uncertainty on $a_\mu$.

Fertl, Martin↗

High Precision Magnetic Field Measurement for the Muon g-2 Experiment

The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon, aµ with a precision of 140 ppb, a four-fold improvement over the former BNL E821 result. If the current discrepancy of about 3.5σ between the Standard Model value for aµ and the former experiments was real, then the new experiment would verify the deviation with >7σ significance. The experiment uses muons with the magic momentum of 3.09 GeV/c stored in a very homogeneous magnetic field of a 45 m long storage ring. The determination of aµ requires the precise knowledge of both the anomalous muon spin precession, ωa, and the magnetic field, ωp, expressed in terms of the free-proton Larmor frequency. The field measurement uses the high precision tool of pulsed Nuclear Magnetic Resonance (pNMR) and requires cross-calibrating a set of probes: a very accurate NMR probe calibrates the 17 probes on the in-vacuum field mapping system (the so-called trolley). This trolley in turn is used to map the field over the full azimuth of the storage ring. The trolley measurement also provides the calibration of the 378 fixed probes around the ring that constantly monitor the field drift. This article presents the summary of the entire field measurement system needed to determine ωp. This work was supported in part by the US DOE, Fermilab and US DOE OHEP under contract No. KA2201020.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon g-2 experiment at Fermilab aims to measure the anomalous magnetic moment, a$_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $\omega_a$, and the average magnetic field in terms of the equivalent, free proton Larmor frequency, $\omega_p$. The measurement of $\omega_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration in terms of $\omega_p$. A crucial element for the multi-step measurement of $\omega_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic In-Vacuum Field Mapping System for the Muon g-2 Experiment

The Muon g-2 experiment at Fermilab will measure the anomalous magnetic moment of the muon, $a^{}_\mu$ with a precision of 140ppb, a four-fold improvement over the former BNL E821 result. If the current discrepancy of about 3.5$\sigma$ between the Standard Model value for $a^{}_\mu$ and the former experiments was real, then the new experiment would verify the deviation with >7$\sigma$ significance. The experiment uses muons with the magic momentum of 3.09GeV/c stored in a very homogeneous magnetic field of a 45m long storage ring. The determination of $a^{}_\mu$ requires the precise knowledge of both the muon spin precession, $\omega^{}_a$, and the magnetic field, $\omega^{}_p$, expressed in terms of the free-proton Larmor frequency. The field measurement uses the high precision tool of pulsed proton Nuclear Magnetic Resonance and requires cross-calibrating a set of probes: a very accurate NMR probe calibrates the 17 probes on the in-vacuum field mapping system (the so-called trolley). This trolley in turn is used to map the field over the full azimuth of the storage ring. The trolley measurement also provides the calibration of the 378 fixed probes around the ring that constantly monitor the field drift. The trolley is particularly important as it measures the relevant field that is seen by the stored muons and this article presents the details of this field mapping system. This work was supported in part by the US DOE, Fermilab and US DOE OHEP under contract No. KA2201020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

Frequency‐Scanning Considerations in Axionlike Dark Matter Spin‐Precession Experiments

Abstract Galactic dark matter may consist of axionlike particles (ALPs) that can be described as an “ultralight bosonic field” oscillating at the ALP Compton frequency. The ALP field can be searched for using nuclear magnetic resonance (NMR), where resonant precession of spins of a polarized sample can be sensitively detected. The ALP mass to which the experiment is sensitive is scanned by sweeping the bias magnetic field. The scanning either results in detection of ALP dark matter or rules out ALP dark matter with sufficiently strong couplings to nuclear spins over the range of ALP masses corresponding to the covered span of Larmor frequencies. In this work, scanning strategies are analyzed with the goal of optimizing the parameter‐space coverage via a proper choice of experimental parameters (e.g., the effective transverse relaxation time).

Zhang, Yuzhe (ORCID:0009000660829066)↗

The Hanle effect applied to magnetic field measurements

The Hanle effect is the modification by a local magnetic field of the polarization due to coherent scattering in spectral lines. It results from the precession of a classical oscillator about the magnetic field direction. The sophisticated quantum-mechanical treatment, which is required to compute the polarization parameters of scattered light, was developed. The main features of the Hanle effect concerning magnetic field measurements are: (1) a good sensitivity within the approximate range 0.1 B gamma rho to 10 B gamma rho where B gamma rho is the field strength yielding a Larmor period equal to the radiative lifetime, (2) there is no Hanle effect for field vectors parallel to the excitating beam, (3) the Hanle effect refers essentially to the linear polarization in a spectral line, (4) various points in the line profile are affected in the same way by change of linear polarization so that polarization parameters can be measured on the integrated line profile.

Leroy, J. L.↗

Fast ion stabilization of tilt in large radius FRCs

The field reversed configuration (FRC) has been a curious case in plasma physics research in that early MHD analysis suggested FRCs should be grossly unstable, while experimental results contradicted that prediction. Later, this theory was able to resolve this contradiction by understanding that finite Larmor radius effects largely negated the MHD predictions. Similarly, previous theoretical studies of beam driven FRCs predicted that such system would be unstable to beam driven modes while, again, experimental results indicated the contradiction. In this paper, we reconcile the theoretical understanding of beam driven modes with experimental observations of stability in these systems. By self-consistently capturing fast ion generation from neutral beam injection and its impact on the plasma equilibrium, we show that low amplitude perturbations in the magnetic field, driven by betatron particles, modify the precession frequencies of the betatron particles such that the drive for compressional Alfvén waves in the thermal plasma is reduced. Finally, we are able to demonstrate, for the first time, stable beam driven FRC evolution at high S*/E in 3D kinetic simulations.

Betatrons↗