The gas phase emitter effect of lanthanum within ceramic metal halide lamps and its dependence on the La vapor pressure and operating frequency

The gas phase emitter effect increases the lamp lifetime by lowering the work function and, with it, the temperature of the tungsten electrodes of metal halide lamps especially for lamps in ceramic vessels due to their high rare earth pressures. It is generated by a monolayer on the electrode surface of electropositive atoms of certain emitter elements, which are inserted into the lamp bulb by metal iodide salts. They are vaporized, dissociated, ionized, and deposited by an emitter ion current onto the electrode surface within the cathodic phase of lamp operation with a switched-dc or ac-current. The gas phase emitter effect of La and the influence of Na on the emitter effect of La are studied by spatially and phase-resolved pyrometric measurements of the electrode tip temperature, La atom, and ion densities by optical emission spectroscopy as well as optical broadband absorption spectroscopy and arc attachment images by short time photography. An addition of Na to the lamp filling increases the La vapor pressure within the lamp considerably, resulting in an improved gas phase emitter effect of La. Furthermore, the La vapor pressure is raised by a heating of the cold spot. In this way, conditions depending on the La vapor pressure and operating frequency are identified, at which the temperature of the electrodes becomes a minimum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly efficient small form factor LED retrofit lamp

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40° and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Report 21.2: Linear (T8) LED Lamp Performance in Five Types of Recessed Troffers

Although lensed troffers are numerous, there are many other types of optical systems as well. This report looks at the performance of three linear (T8) LED lamps—chosen primarily based on their luminous intensity distributions (narrow, medium, and wide beam angles)—as well as a benchmark fluorescent lamp in five different troffer types. Also included are the results of a subjective evaluation. Results show that linear (T8) LED lamps can improve luminaire efficiency in K12-lensed and parabolic-louvered troffers, effect little change in volumetric and high-performance diffuse-lensed type luminaires, but reduce efficiency in recessed indirect troffers. These changes can be accompanied by visual appearance and visual comfort consequences, especially when LED lamps with clear lenses and narrow distributions are installed. Linear (T8) LED lamps with diffuse apertures exhibited wider beam angles, performed more similarly to fluorescent lamps, and received better ratings from observers. Guidance is provided on which luminaires are the best candidates for retrofitting with linear (T8) LED lamps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lamp reliability studies for improved satellite rubidium frequency standard

In response to the premature failure of Rb lamps used in Rb atomic clocks onboard NAVSTAR GPS satellites experimental and theoretical investigations into their failure mechanism were initiated. The primary goal of these studies is the development of an accelerated life test for future GPS lamps. The primary failure mechanism was identified as consumption of the lamp's Rb charge via direct interaction between Rb and the lamp's glass surface. The most effective parameters to accelerate the interaction between the Rb and the glass are felt to be RF excitation power and lamp temperature. Differential scanning calorimetry is used to monitor the consumption of Rb within a lamp as a function of operation time. This technique yielded base line Rb consumption data for GPS lamps operating under normal conditions.

Frueholz, R. P.↗

Evaluation of GOES encoder lamps

Aging characteristics and life expectancies of flight quality, tungsten filament, encoder lamps are similar to those of 'commercial' grade gas filled lamps of similar construction, filament material and filament temperature. The aging and final failure by filament burnout are caused by single crystal growth over large portions of the filament with the concomitant development of facets and notches resulting in reduction of cross section and mechanical weakening of the filament. The life expectancy of presently produced lamps is about one year at their nominal operating voltage of five volts dc. At 4.5 volts, it is about two years. These life times are considerably shorter, and the degradation rates of lamp current and light flux are considerably higher, than were observed in the laboratory and in orbit on lamps of the same type manufactured more than a decade ago. It is speculated that the filaments of these earlier lamps contained a crystallization retarding dopant, possibly thorium oxide. To obtain the desired life expectancy of or = to four years in present lamps, operating voltages of or = to four volts dc would be required.

Viehmann, W.↗

Full-scale Drag Tests of Landing Lamps

Drag tests were conducted in the N.A.C.A. full-scale wind tunnel on full-scale models of two Army Air Corps type A-6 landing lamps mounted on an 8 by 48 foot airfoil. Drag measurements were made with the lamps in the leading edge and attached to the lower surface at the 5 and 10 percent chord positions. The drag of the lamps when faired into the airfoil was also measured. The results show that at 100 miles per hour and at the angle of minimum drag of the airfoil the unaired lamps in the leading edge produced an increase in drag of 5.5 pounds and that the unaired lamps on the lower surface at either position increased the airfoil drag 22.5 pounds. These increases represent 6 and 24 percent of the minimum drag of the airfoil, respectively. Fairing the lamps into the airfoil reduced the drag of the lamps about 50 percent for the leading-edge position and about 60 percent for the two lower surface positions.

Dearborn, C H↗

Reduced phenylalanine ammonia-lyase and tyrosine ammonia-lyase activities and lignin synthesis in wheat grown under low pressure sodium lamps

Wheat (Triticum aestivum L. cv Fremont) grown in hydroponic culture under 24-hour continuous irradiation at 560 to 580 micromoles per square meter per second from either metalhalide (MH), high pressure sodium (HPS), or low pressure sodium (LPS) lamps reached maturity in 70 days. Grain yields were similar under all three lamps, although LPS-grown plants lodged at maturity. Phenylalanine ammonia-lyase (PAL) and a tyrosine ammonia lyase (TAL) with lesser activity were detected in all extracts of leaf, inflorescence, and stem. Ammonia-lyase activities increased with age of the plant, and plants grown under the LPS lamp displayed PAL and TAL activities lower than wheat cultured under MH and HPS radiation. Greenhouse solar-grown wheat had the highest PAL and TAL activities. Lignin content of LPS-grown wheat was also significantly reduced from that of plants grown under MH or HPS lamps or in the greenhouse, showing a correlation with the reduced PAL and TAL activities. Ratios of far red-absorbing phytochrome to total phytochrome were similar for all three lamps, but the data do not yet warrant a conclusion about specific wavelengths missing from the LPS lamps that might have induced PAL and TAL activities in plants under the other lamps.

Triticum/enzymology/growth & development/metabolis↗

Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and investigation of a novel concentrator used in solar fiber lamp

A novel concentrator used in solar fiber lamp has been designed and made. The method of the design has been introduced. The lamp has been tested under the real solar condition and the experiment curves have been given. The light transmission will be influenced by the structure of the lamp and the diameter of the fiber, which has been studied in this paper. The experimental results show that the brightness of this solar fiber lamp is about the brightness of a 6-W ordinary electrical energy-saving lamp. The computer simulation for the lamp has been presented and the improvement schemes are proposed. (author)

14 SOLAR ENERGY↗

Max Tech and Beyond: High-Intensity Discharge Lamps

High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of LED Retrofit Lamps at the Smithsonian Art Museum, Washington, DC

In the fall of 2010, Pacific Northwest National Laboratory contacted Scott Rosenfeld, Lighting Designer for the Smithsonian American Art Museum, to see if the Museum would be willing to participate in a GATEWAY demonstration project in which light-emitting diode (LED) replacement lamps would be used in exhibit space. At that time, the museum industry was concerned about increased damage potential from LEDs and other energy efficient lighting sources that produce a discontinuous spectrum. The Museum agreed to participate, based on a review of the existing literature conducted by Steven Weintraub of Art Preservation Services for the American Institute of Conservation, and subsequent testing of solid-state lighting sources on light sensitive materials performed by Jim Druzik of the Getty Conservation Institute. Thus began the process, which lasted more than a year, of procuring lamp samples and performance data, testing them in the museum workshop, temporarily installing the lamps in one gallery for feedback, and ultimately replacing all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries of the Museum’s Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of using LED replacement lamps in art galleries housing national treasures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of LED Retrofit Lamps at an Exhibit of 19 th Century Photography at the Getty Museum

In March 2011, the J. Paul Getty Museum in Malibu, California, installed an exhibit titled “In Search of Biblical Lands: From Jerusalem to Jordan in Nineteenth-Century Photography.” This collection of toned albumen photographic prints presents a rare photographic narrative of the people, life, landscape, and ancient structures of the Holy Land of the Middle East. Dating from between 1840 and 1905, these large-format photographs are highly detailed albumen prints. Prints of this type were frequently handcolored with pigments and dyes that are sensitive to light. The Getty Conservation Institute (GCI) confirmed this sensitivity with microfading testing. The curator decided to display the photographs for 26 weeks, illuminated between 25 and 50 lux, and use light-emitting diode (LED) PAR38 lamps to replace tungsten halogen illumination, since these lamps emit no ultraviolet (UV) or infrared (IR) radiation. The GCI suggested providing additional protection by monitoring three photographs on exhibit at two-week intervals. The preliminary fading tests, although with different lamps than would be used in the exhibition but having similar correlated color temperatures, had suggested that the lamps would cause no more damage than UV/IR filtered halogen lamps, and possibly less. Regular checks of the monitored photographs showed small, but visually undetectable, changes from the installed LED lamps over the 6-month exhibition, no more than would be expected from incandescent lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of LED Retrofit Lamps in the Jordan Schnitzer Museum of Art

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled “Running the Numbers,” was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Report Highlights LAMP's Role as a Robust and Reliable System for Wave Energy Converter Testing

Harnessing the power of waves requires more than just putting devices in the ocean - it takes tools that can refine and accelerate innovation before the first deployment. That's where NLR's largeamplitude motion platform, or LAMP, comes in. LAMP is a six-degree-of-freedom motion system designed to replicate the response of a wave energy converter (WEC) device in realistic ocean conditions. By letting researchers evaluate WEC performance in a safe, controlled lab environment before moving offshore, LAMP helps accelerate innovation while reducing risk. An NLR report, titled Initial Characterization of the NLR LargeAmplitude Motion Platform (https://www.nrel.gov/docs/fy26osti/93733.pdf), provides a deeper understanding of LAMP's capabilities and also lays the groundwork for future advancements in WEC testing methodologies. Researchers studied LAMP's amplitude and frequency limits across different payloads and collected data from 16 test profiles. Testing demonstrated that platform accuracy remained consistent across all payloads evaluated; researchers expect similar accuracy up to LAMP's 10,000-kilogram capacity limit. The measured position limits for single degrees of freedom experienced by WECs, including surge, sway, heave, roll, pitch, and yaw, also exceeded the original manufacturer specifications, providing new insight into the true boundaries of the system.

16 TIDAL AND WAVE POWER↗

Local Resistance Profiling of Ultra Shallow Junction Annealed with Combination of Spike Lamp and Laser Annealing Processes using Scanning Spreading Resistance Microscope

Local resistance profiles of ultra shallow boron and arsenic implanted into silicon with energies of 2.0 and 4.0 keV and doses of 2.0x10{sup 15} and 1.0x10{sup 15} ions/cm{sup 2} activated by a combination of conventional spike lamp and laser annealing processes were measured by scanning spreading resistance microscope (SSRM) with a depth resolution of less than 10 nm. The lowest local resistance at the low resistance region in 2.0 keV boron implanted silicon with 1050 deg. C spike lamp annealing followed by 0.35 kW/mm{sup 2} laser annealing was half of that without laser annealing. The lowest local resistance at the low resistance region in the arsenic implanted silicon activated by 1050 deg. C spike lamp annealing followed by 0.39 kW/mm{sup 2} laser annealing was 74% lower than that followed by 0.36 kW/mm{sup 2} laser annealing. The lowest local resistances at the low resistance regions in the arsenic implanted silicon with 0.36 and 0.39 kW/mm{sup 2} laser annealing followed by 1050 deg. C spike lamp annealing were 41 and 33% lower than those with spike lamp annealing followed by laser annealing. Laser annealing followed by spike lamp annealing could suppress the diffusion of the impurities and was suitable for making the ultra shallow and low resistance regions.

36 MATERIALS SCIENCE↗

Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documented methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen irradiance standard lamp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lamp pumped Nd:YAG laser. Space-qualifiable Nd:YAG laser for optical communications

Results are given of a program concerned with the design, fabrication, and evaluation of alkali pump lamps for eventual use in a space qualified Nd:YAG laser system. The study included evaluation of 2mm through 6mm bore devices. Primary emphasis was placed upon the optimization of the 4mm bore lamp and later on the 6mm bore lamp. As part of this effort, reference was made to the Sylvania work concerned with the theoretical modeling of the Nd:YAG laser. With the knowledge gained, a projection of laser performance was made based upon realistic lamp parameters which should easily be achieved during following developmental efforts. Measurements were made on the lamp performance both in and out of the cavity configuration. One significant observation was that for a constant vapor pressure device, the spectral and fluorescent output did not vary for vacuum or argon environment. Therefore, the laser can be operated in an inert environment (eg. argon) with no degradation in output. Laser output of 3.26 watts at 430 watts input was obtained for an optimized 4mm bore lamp.

Ward, K. B.↗

Test plane uniformity analysis for the MSFC solar simulator lamp array

A preliminary analysis was made on the solar simulator lamp array. It is an array of 405 tungsten halogen lamps with Fresnel lenses to achieve the required spectral distribution and collimation. A computer program was developed to analyze lamp array performance at the test plane. Measurements were made on individual lamp lens combinations to obtain data for the computer analysis. The analysis indicated that the performance of the lamp array was about as expected, except for a need to position the test plane within 2.7 m of the lamp array to achieve the desired 7 percent uniformity of illumination tolerance.

Griner, D. B.↗