Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LABORATORY APPARATUS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Blood Vessel Tension Tester

In the photo, a medical researcher is using a specially designed laboratory apparatus for measuring blood vessel tension. It was designed by Langley Research Center as a service to researchers of Norfolk General Hospital and Eastern Virginia Medical School, Norfolk, Virginia. The investigators are studying how vascular smooth muscle-muscle in the walls of blood vessels-reacts to various stimulants, such as coffee, tea, alcohol or drugs. They sought help from Langley Research Center in devising a method of measuring the tension in blood vessel segments subjected to various stimuli. The task was complicated by the extremely small size of the specimens to be tested, blood vessel "loops" resembling small rubber bands, some only half a millimeter in diameter. Langley's Instrumentation Development Section responded with a miniaturized system whose key components are a "micropositioner" for stretching a length of blood vessel and a strain gage for measuring the smooth muscle tension developed. The micropositioner is a two-pronged holder. The loop of Mood vessel is hooked over the prongs and it is stretched by increasing the distance between the prongs in minute increments, fractions of a millimeter. At each increase, the tension developed is carefully measured. In some experiments, the holder and specimen are lowered into the test tubes shown, which contain a saline solution simulating body fluid; the effect of the compound on developed tension is then measured. The device has functioned well and the investigators say it has saved several months research time.

Source record↗

Chamber for Aerosol Deposition of Bioparticles

Laboratory apparatus is depicted that is a chamber for aerosol deposition of bioparticles on surfaces of test coupons. It is designed for primary use in inoculating both flat and three-dimensional objects with approximately reproducible, uniform dispersions of bacterial spores of the genus Bacillus so that the objects could be used as standards for removal of the spores by quantitative surface sampling and/or cleaning processes. The apparatus is also designed for deposition of particles other than bacterial spores, including fungal spores, viruses, bacteriophages, and standard micron-sized beads. The novelty of the apparatus lies in the combination of a controllable nebulization system with a settling chamber large enough to contain a significant number of test coupons. Several companies market other nebulizer systems, but none are known to include chambers for deposition of bioparticles to mimic the natural fallout of bioparticles. The nebulization system is an expanded and improved version of commercially available aerosol generators that include nebulizers and drying columns. In comparison with a typical commercial aerosol generator, this system includes additional, higher-resolution flowmeters and an additional pressure regulator. Also, unlike a typical commercial aerosol generator, it includes stopcocks for separately controlling flows of gases to the nebulizer and drying column. To maximize the degree of uniformity of dispersion of bioaerosol, the chamber is shaped as an axisymmetrical cylinder and the aerosol generator is positioned centrally within the chamber and aimed upward like a fountain. In order to minimize electric charge associated with the aerosol particles, the drying column is made of aluminum, the drying column is in direct contact with an aluminum base plate, and three equally spaced Po-210 antistatic strips are located at the exit end of the drying column. The sides and top of the chamber are made of an acrylic polymer; to prevent accumulation of electric charge on them, they are spray-coated with an anti-static material. During use, the base plate and the sides and top of the chamber are grounded as a further measure to minimize the buildup of electric charge.

Kern, Roger↗

Insulating Material for Next-Generation Spacecraft

A report discusses the development of a flexible thermal-insulation material for cryogenic tanks in next-generation spacecraft. This material is denoted Advanced Reusable All-temperature Multimode Insulation System (ARAMIS). The report begins by describing the need for ARAMIS and the technological challenges of developing a single material that is useable throughout the temperature range from storage of liquid hydrogen (20 K) to atmospheric-reentry heating (>2,000 K), has the requisite low thermal conductivity, resists condensation of moisture without need for a gas purge, and withstands reentry heating for a 400-mission lifetime. The report then discusses laboratory apparatuses for testing materials that have been and will be considered as candidates for the development of ARAMIS.

White, Susan↗

Multistage Magnetic Separator of Cells and Proteins

The multistage electromagnetic separator for purifying cells and magnetic particles (MAGSEP) is a laboratory apparatus for separating and/or purifying particles (especially biological cells) on the basis of their magnetic susceptibility and magnetophoretic mobility. Whereas a typical prior apparatus based on similar principles offers only a single stage of separation, the MAGSEP, as its full name indicates, offers multiple stages of separation; this makes it possible to refine a sample population of particles to a higher level of purity or to categorize multiple portions of the sample on the basis of magnetic susceptibility and/or magnetophoretic mobility. The MAGSEP includes a processing unit and an electronic unit coupled to a personal computer. The processing unit includes upper and lower plates, a plate-rotation system, an electromagnet, an electromagnet-translation system, and a capture-magnet assembly. The plates are bolted together through a roller bearing that allows the plates to rotate with respect to each other. An interface between the plates acts as a seal for separating fluids. A lower cuvette can be aligned with as many as 15 upper cuvette stations for fraction collection during processing. A two-phase stepping motor drives the rotation system, causing the upper plate to rotate for the collection of each fraction of the sample material. The electromagnet generates a magnetic field across the lower cuvette, while the translation system translates the electromagnet upward along the lower cuvette. The current supplied to the electromagnet, and thus the magnetic flux density at the pole face of the electromagnet, can be set at a programmed value between 0 and 1,400 gauss (0.14 T). The rate of translation can be programmed between 5 and 2,000 m/s so as to align all sample particles in the same position in the cuvette. The capture magnet can be a permanent magnet. It is mounted on an arm connected to a stepping motor. The stepping motor rotates the arm to position the capture magnet above the upper cuvette into which a fraction of the sample is collected. The electronic unit includes a power switch, power-supply circuitry that accepts 110-Vac input power, an RS-232 interface, and status lights. The personal computer runs the MAGSEP software and controls the operation of the MAGSEP through the RS-232 interface. The status of the power, the translating electromagnet, the capture magnet, and the rotation of the upper plate are indicated in a graphical user interface on the computer screen.

Barton, Ken↗

NASA Tech Briefs, July 2004

Topics: Optoelectronic Sensor System for Guidance in Docking; Hybrid Piezoelectric/Fiber-Optic Sensor Sheets; Multisensor Arrays for Greater Reliability and Accuracy; Integrated-Optic Oxygen Sensors; Ka-Band Autonomous Formation Flying Sensor; CMOS VLSI Active-Pixel Sensor for Tracking; Lightweight, Self-Deploying Foam Antenna Structures; Electrically Small Microstrip Quarter-Wave Monopole Antennas; A 2-to-28-MHz Phase-Locked Loop; Portable Electromyograph; Open-Source Software for Modeling of Nanoelectronic Devices; Software for Generating Strip Maps from SAR Data; Calibration Software for use with Jurassicprok; Software for Probabilistic Risk Reduction; Software Processes SAR Motion-Measurement Data; Improved Method of Purifying Carbon Nanotubes; Patterned Growth of Carbon Nanotubes or Nanofibers; Lightweight, Rack-Mountable Composite Cold Plate/Shelves; SiC-Based Miniature High-Temperature Cantilever Anemometer; Inlet Housing for a Partial-Admission Turbine; Lightweight Thermoformed Structural Components and Optics; Growing High-Quality InAs Quantum Dots for Infrared Lasers; Selected Papers on Protoplanetary Disks; Module for Oxygenating Water without Generating Bubbles; Coastal Research Imaging Spectrometer; Rapid Switching and Modulation by use of Coupled VCSELs; Laser-Induced-Fluorescence Photogrammetry and Videogrammetry; Laboratory Apparatus Generates Dual-Species Cold Atomic Beam; Laser Ablation of Materials for Propulsion of Spacecraft; Small Active Radiation Monitor; Hybrid Image-Plane/Stereo Manipulation; Partitioning a Gridded Rectangle into Smaller Rectangles; Digital Radar-Signal Processors Implemented in FPGAs; Part 1 of a Computational Study of a Drop-Laden Mixing Layer; and Some Improvements in Signal-Conditioning Circuits.

Source record↗

Laboratory Simulations of Mars Evaporite Geochemistry

Evaporite-rich sedimentary deposits on Mars were formed under chemical conditions quite different from those on Earth. Their unique chemistries record the chemical and aqueous conditions under which they were formed and possibly subsequent conditions to which they were subjected. We have produced evaporite salt mineral suites in the laboratory under two simulated Martian atmospheres: (1) present-day and (2) a model of an ancient Matian atmosphere rich in volcanic gases. The composition of these synthetic Mars evaporites depends on the atmospheres under which they were desiccated as well as the chemistries of their precursor brines. In this report, we describe a Mars analog evaporite laboratory apparatus and the experimental methods we used to produce and analyze the evaporite mineral suites.

Moore, Jeffrey M.↗

Iodine Hall Thruster Propellant Feed System for a CubeSat

The components required for an in-space iodine vapor-fed Hall effect thruster propellant management system are described. A laboratory apparatus was assembled and used to produce iodine vapor and control the flow through the application of heating to the propellant reservoir and through the adjustment of the opening in a proportional flow control valve. Changing of the reservoir temperature altered the flowrate on the timescale of minutes while adjustment of the proportional flow control valve changed the flowrate immediately without an overshoot or undershoot in flowrate with the requisite recovery time associated with thermal control systems. The flowrates tested spanned a range from 0-1.5 mg/s of iodine, which is sufficient to feed a 200-W Hall effect thruster.

Polzin, Kurt A.↗

Propeller-induced structure-borne noise - Laboratory-based test apparatus

A potentially important source of structure-borne interior noise transmission in advanced turboprop aircraft is the impingement of the propeller wake/vortex on downstream aerodynamic surfaces. The expected levels of propeller wake/vortex-induced structure-borne noise transmission are not known nor can they be determined with present-day technology. A test apparatus has been designed, built and calibrated for the purposes of studying propeller-induced, structure-borne noise transmission in prototypical aircraft structures. The principal approach to the test apparatus design was to provide a physical means of separating the airborne and structure-borne noise components so that the structure-borne noise transmission response could be studied directly without airborne noise contamination. This was accomplished by housing the receiving fuselage structure in an acoustic shield fitted with a wing-to-fuselage acoustic seal. Initial evaluation of the wing-to-fuselage acoustic seal indicates adequate airborne noise isolation to allow direct study of structure-borne noise transmission.

Unruh, J. F.↗

Preparation for microgravity: The role of the microgravity materials science laboratory

A laboratory dedicated to ground based materials processing in preparation for space flight was established at the NASA Lewis Research Center. Experiments are performed to delineate the effects of gravity on processes of both scientific and commercial interest. Processes are modeled physically and mathematically. Transport model systems are used where possible to visually track convection, settling, crystal growth, phase separation, agglomeration, vapor transport, diffusive flow, and polymers reactions. The laboratory contains apparatus which functionally duplicates apparatus available for flight experiments and other pieces instrumented specifically to allow process characterization. Materials addressed include metals, alloys, salts, glasses, ceramics, and polymers. The Microgravity Materials Science Laboratory is staffed by engineers and technicians from a variety of disciplines and is open to users from industry and academia as well as the government. Examples will be given of the laboratory apparatus typical experiments and results.

Johnston, J. Christopher↗

Commercial investigation results for the generic bioprocessing apparatus flown on United States Microgravity Laboratory-1

The Generic Bioprocessing Apparatus (BPA) payload was developed by BioServe to support the commercial flight development needs of our specialized consortia comprised of business, academic, and government entities. The consortia have commitments to explore commercial opportunities in bioprocessing, biomedical models, and closed agricultural systems. In addition, some members of BioServe have interests in the development and/or qualification of enabling flight hardware used in life sciences space flight testing. Some business and academic entities have interests in more than one of these consortia. To aid in payload development, flight, and analysis, each consortium member contributes resources ranging from proprietary expertise and materials, to hardware and cash. Professionals from business, academia, and government often interact with each other via graduate research assistants who do much of the 'hands-on' payload preparation and subsequent data analyses. The GBA supported research, testing, and development activities for each different BioServe consortium. It produced an environment in which professionals from diverse backgrounds came together with a single focus. And, it provided a truly novel learning environment for a youthful new cadre of space professionals committed to the exploration of commercial opportunities presented by space. Since the GBA supported a large number of different experiments, this paper briefly describes the payload characteristics and the essential operations of the payload. A summary of the experiments is presented. Finally, a few of the experiments are described in detail highlighting some novel effects of space flight on life science systems. Portions of the reported work have or will appear in appropriate archival journals as cited in the bibliography. In several instances, data collected from USML-1 have been supplemented with related data collected on more recent STS missions.

Stodieck, Louis S.↗

Advanced Small Rocket Chambers. Basic Program and Option 2: Fundamental Processes and Material Evaluation

Propellants, chamber materials, and processes for fabrication of small high performance radiation cooled liquid rocket engines were evaluated to determine candidates for eventual demonstration in flight-type thrusters. Both storable and cryogenic propellant systems were considered. The storable propellant systems chosen for further study were nitrogen tetroxide oxidizer with either hydrazine or monomethylhydrazine as fuel. The cryogenic propellants chosen were oxygen with either hydrogen or methane as fuel. Chamber material candidates were chemical vapor deposition (CVD) rhenium protected from oxidation by CVD iridium for the chamber hot section, and film cooled wrought platinum-rhodium or regeneratively cooled stainless steel for the front end section exposed to partially reacted propellants. Laser diagnostics of the combustion products near the hot chamber surface and measurements at the surface layer were performed in a collaborative program at Sandia National Laboratories, Livermore, CA. The Material Sample Test Apparatus, a laboratory system to simulate the combustion environment in terms of gas and material temperature, composition, and pressure up to 6 Atm, was developed for these studies. Rocket engine simulator studies were conducted to evaluate the materials under simulated combustor flow conditions, in the diagnostic test chamber. These tests used the exhaust species measurement system, a device developed to monitor optically species composition and concentration in the chamber and exhaust by emission and absorption measurements.

Jassowski, Donald M.↗

Apparatus analysis and preliminary design of low gravity porous solids experiment for STS Orbiter mid-deck

The apparatus analysis laboratory equipment design and fabrication and the preliminary design of the Combustion of Porous Solids Experiment for operation in the mid-deck area of the Shuttle are described. The apparatus analysis indicated that the mid-deck region of the STS was a feasible region of the Shuttle for operation. A sixteen tube concept was developed with tubes of 75 cm length and up to 5.6 cm accommodated. The experiment is viewed by IR sensors and a 16 mm camera. Laboratory equipment was designed and fabricated to test the parible injection, mixing and venting concepts. This equipment was delivered to NASA/LeRC. A preliminary design was made for the experiment based upon the apparatus analysis. The design incorporated results from the Phase ""O'' Safety Review. This design utilizes a closed tube concept in which the particles are stored, injected and burned with no coupling to the Shuttle environment. Drawings of the major components and an assembly are given. The electronics are described for the experiment. An equipment list is presented and an experiment weight estimate is determined. The mission operation requirements are outlined.

Fleeter, R. D.↗

The N.A.C.A. Photographic Apparatus for Studying Fuel Sprays from Oil Engine Injection Valves and Test Results from Several Researches

Apparatus for recording photographically the start, growth, and cut-off of oil sprays from injection valves has been developed at the Langley Memorial Aeronautical Laboratory. The apparatus consists of a high-tension transformer by means of which a bank of condensers is charged to a high voltage. The controlled discharge of these condensers in sequence, at a rate of several thousand per second, produces electric sparks of sufficient intensity to illuminate the moving spray for photographing. The sprays are injected from various types of valves into a chamber containing gases at pressures up to 600 pounds per square inch. Several series of pictures are shown. The results give the effects of injection pressure, chamber pressure, specific gravity of the fuel oil used, and injection-valve design, upon spray characteristics.

Beardsley, Edward G↗

Instruction manual for epitaxial apparatus

Instruction manual for apparatus using programmer operation of electronic valves for etching and growth of single crystal silicon, deposition of silicon dioxide, and nucleation site treatment

MANUAL↗

A simulation study of active feedback supression of dynamic response in helicopter rotor blades

A parameter study is presented for active feedback control applied to a helicopter rotor blade during forward flight. The study was performed on an electromechanical apparatus which included a mechanical model rotor blade and electronic analog simulation of interaction between blade deflections and aerodynamic loading. Blade response parameters were obtained for simulated vortex impinging at the blade tip at one pulse per revolution, and for a pulse which traveled from the blade tip toward its root. Results show that the response in a 1 - 10-per-rev frequency band is diminished by the feedback action, but at the same time responses at frequencies above 10-per-rev become increasingly more prominent with increased feedback amplitude, and can even lead to instability at certain levels. It appears that the latter behavior results from limitations of the laboratory simulation apparatus, rather than genuine potential behavior for a prototype helicopter.

Kana, D. D.↗