Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “J HOOK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ferrite attenuator modulation improves antenna performance

Ferrite attenuator inserted into appropriate waveguide reduces the gain of the antenna element which is causing interference. Modulating the ferrite attenuator to change the antenna gain at the receive frequency permits ground tracking until the antenna is no longer needed.

Hooks, J. C.↗

Estimation of old field ecosystem biomass using low altitude imagery

Color-infrared photography was used to evaluate the biomass of experimental plots in an old-field ecosystem that was treated with different levels of waste water from a sewage treatment facility. Cibachrome prints at a scale of approximately 1:1,600 produced from 35 mm color infrared slides were used to analyze density patterns using prepared tonal density scales and multicell grids registered to ground panels shown on the photograph. Correlation analyses between tonal density and vegetation biomass obtained from ground samples and harvests were carried out. Correlations between mean tonal density and harvest biomass data gave consistently high coefficients ranging from 0.530 to 0.896 at the 0.001 significance level. Corresponding multiple regression analysis resulted in higher correlation coefficients. The results of this study indicate that aerial infrared photography can be used to estimate standing crop biomass on waste water irrigated old field ecosystems. Combined with minimal ground truth data, this technique could enable managers of wastewater irrigation projects to precisely time harvest of such systems for maximal removal of nutrients in harvested biomass.

Nor, S. M.↗

Estimation of old field ecosystem biomass using low altitude imagery

Color-infrared photography was used to evaluate the biomass of experimental plots in an old-field ecosystem that was treated with different levels of waste water from a sewage treatment facility. Cibachrome prints at a scale of approximately 1:1,600 produced from 35 mm color infrared slides were used to analyze density patterns using prepared tonal density scales and multicell grids registered to ground panels shown on the photograph. Correlations between mean tonal density and harvest biomass data gave consistently high coefficients ranging from 0.530 to 0.896 at the 0.001 significance level. Corresponding multiple regression analysis resulted in higher correlation coefficients. The results indicate that aerial infrared photography can be used to estimate standing crop biomass on waste water irrigated old field ecosystems. Combined with minimal ground truth data, this technique could enable managers of waste water irrigation projects to precisely time harvest of such systems for maximal removal of nutrients in harvested biomass.

Nor, S. M.↗

Long-Wavelength Rupturing Instability in Surface-Tension-Driven Benard Convection

A liquid layer with a free upper surface and heated from below is subject to thermocapillary-induced convective instabilities. We use very thin liquid layers (0.01 cm) to significantly reduce buoyancy effects and simulate Marangoni convection in microgravity. We observe thermocapillary-driven convection in two qualitatively different modes, short-wavelength Benard hexagonal convection cells and a long-wavelength interfacial rupturing mode. We focus on the long-wavelength mode and present experimental observations and theoretical analyses of the long-wavelength instability. Depending on the depths and thermal conductivities of the liquid and the gas above it, the interface can rupture downwards and form a dry spot or rupture upwards and form a high spot. Linear stability theory gives good agreement to the experimental measurements of onset as long as sidewall effects are taken into account. Nonlinear theory correctly predicts the subcritical nature of the bifurcation and the selection between the dry spot and high spots.

Swift, J. B.↗

Validation of Land Surface Temperature Products Derived from the Visible Infrared Imaging Radiometer Suite (VIIRS) Using Ground-based and Heritage Satellite Measurements

Thermal infrared satellite observations of the Earth's surface are widely used to retrieve Land Surface Temperature (LST) and monitor LST changes around the world. Since January 2012, the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-Orbiting Partnership (S-NPP) has provided daily observations of LST with a spatial resolution of 750 m at nadir. Comparison of the standard VIIRS LST product with the equivalent daily standard product from the Moderate Resolution Imaging Spectroradiometer (MODIS) collection-5 and with ground-based measurements over vegetated and inland water surfaces showed good agreement. Analysis indicated the accuracy and precision of the VIIRS product over these cover types was 0.2 K and 2.0 K respectively provided the analyses included appropriate compensation for any spatial heterogeneity in LST within the validation site. However, comparisons between in situ LST and the VIIRS and MODIS LST.

Land surface temperature↗

Landsat-7 ETM+ Radiometric Calibration Status

Now in its 17th year of operation, the Enhanced Thematic Mapper + (ETM+), on board the Landsat-7 satellite, continues to systematically acquire imagery of the Earth to add to the 40+ year archive of Landsat data. Characterization of the ETM+ on-orbit radiometric performance has been on-going since its launch in 1999. The radiometric calibration of the reflective bands is still monitored using on-board calibration devices, though the Pseudo-Invariant Calibration Sites (PICS) method has proven to be an effect tool as well. The calibration gains were updated in April 2013 based primarily on PICS results, which corrected for a change of as much as -0.2%/year degradation in the worst case bands. A new comparison with the SADE database of PICS results indicates no additional degradation in the updated calibration. PICS data are still being tracked though the recent trends are not well understood. The thermal band calibration was updated last in October 2013 based on a continued calibration effort by NASA/Jet Propulsion Lab and Rochester Institute of Technology. The update accounted for a 0.31 W/sq m/ sr/micron bias error. The updated lifetime trend is now stable to within + 0.4K.

Julia A Barsi↗

NASA's Surface Biology and Geology Concept Study: Status and Next Steps

The National Academies Decadal Survey for Earth Science recommended that NASA pursue global imaging spectroscopy and thermal infrared measurements in the coming decade [1]. Both measurements would offer repeat coverage on approximately five-day to biweekly cadence, with comprehensive coverage of the globe's coastal and terrestrial area. This would be an unprecedented volume of data with the potential to transform remote sensing practice. To address this recommendation, NASA has sponsored a concept study by NASA research centers and associated university partners (https://sbg.jpl.nasa.gov). This study is determining a family of architecture options - including launch vehicle, spacecraft, instrument, and suborbital components - that could address the Decadal Survey objectives. The architecture study is driven by science needs and builds on input of the research community. As of this writing, the study is entering a phase in which a large field of system possibilities is pared down to a representative handful for an ultimate decision by NASA.

Imaging Spectroscopy↗

Landsat-8 TIRS Thermal Radiometric Calibration Status

The Landsat-8 Thermal Infrared Sensor (TIRS) has been acquiring two-band thermal infrared images of the Earth’s surface since 2013. The calibration of the two-band system has been monitored using the on-board calibrator and validated with vicarious calibration performed by NASA/JPL and RIT since launch. Soon after launch, it was discovered that the instrument had a significant stray light effect that was affecting the radiometric calibration. The stray light was corrected in the processing system in 2017. Since then, it has become apparent that there was an additional radiometric error, based on the vicarious calibration results. With a failure within the primary electronic system and subsequent switch to the redundant electronic system, the TIRS instrument effectively has two separate calibration regimes. The vicarious calibration found a statistically significant calibration error, primarily a constant over time, in Band 11 on the primary electronics (Feb 11,2013 through March 5,2015) of about -0.6K at 300K. The calibration error in Band 10 was smaller though still statistically significant at about 0.2K at 300K. On the redundant side(March 5,2015 to present), the calibration error is more signal dependent than time dependent. Both bands are affected, with Band 10 having an error between 1K and -0.4K (between 273-320K) and Band 11 having an error between 0.8K and -1.44K (between 273-320K).This calibration error will be corrected within the USGS Landsat Product Generation System with the release of Landsat Collection-2 products. The Collection-2 release also includes a correction to the relative radiometric calibration of TIRS data. Striping as a result of poor detector-to-detector normalization has been increasing in the imagery since launch. The TIRS relative radiometric calibration will be updated based on internal calibrator data to remove the stripes on a quarterly basis. The visible stripes are generally at 0.1-0.2% level, though there are some detectors in each band that have changed by 1% or more. The Collection-2 release will result in much more uniform TIRS images.

Julia A Barsi↗

On-Orbit Spatial Performance Characterization for Thermal Infrared Imagers of Landsat 7, 8, and 9, ECOSTRESS and CTI

In this analysis of the spatial resolving power of thermal imagery products we focus on four satellite instruments that are used in research and applications, for example to monitor land surface temperature and derive evapotranspiration. These are thermal imagers on Landsat 7, Landsat 8, and Landsat 9, as well as the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS). We compiled sets of close-in-time, day-time images of bridges surrounded by open water bodies, captured by each of the satellite imagers during cloud-free moments. Where possible, we also included some images captured by the Compact Thermal Imager (CTI), a technology demonstrator that was co-located with ECOSTRESS on the International Space Station in 2019. Bridges were found to provide a sufficient thermal contrast with the water surface to quantify the line-spread function of satellite-based thermal products. The full-width-at-half-max of a gaussian beam model fitted to this transect quantifies the on-orbit spatial resolution of different imagers. The results show some loss of spatial resolving power in the final product delivered to end-users as compared to the at-sensor characterization of spatial resolution. For Landsat 7, 8 and 9, the spatial resolution of the thermal bands is 1.5 times the ground sampling distance of 60 m and 100 m respectively. For the ECOSTRESS the difference is up to twice the sampling distance of 78 by 69 m2. Since spatial resolution is a main driver for instrument design it is important to understand and communicate this discrepancy between pre-flight design parameters and the characteristics of the surface imagery delivered to the user community. The goal of this research is to facilitate an improved fusion of current and future satellite observations into harmonized products with superior temporal and spatial characteristics.

thermal infrared↗