Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ion-Selective”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Polyamide-Based Ion Exchange Membranes: Cation-Selective Transport through Water Purification Membranes

Ion-selective membranes are necessary components of many electrochemical systems including fuel cells, electrolyzers, redox flow batteries, and electrodialyzers. Perfluorinated sulfonated membranes (PFSMs) dominate these applications due to their excellent combination of fast ion transport, stability, and processability. However, perfluorinated cation exchange membranes (CEMs) are expensive, and their production process involves chemistry that generates toxic perfluorinated chemicals. The development of affordable, nonfluorinated membranes with a competitive combination of high ion selectivity, transport, and stability could help enable the widespread use of the technologies listed above while hastening the development of emerging electrochemical systems, including aqueous alkaline CO 2 sorbent regeneration. To this end, we pursue the use of thin-film composite polyamide (PA-TFCs) membranes–those that typically find application in reverse osmosis and nanofiltration desalination–as cation-selective exchange membranes. Given their negative surface charge under neutral-to-alkaline conditions, PA-TFCs can serve as effective CEMs in these pH regimes. We prepared a series of PA-TFCs from traditional monomers (trimesoyl chloride and piperazine) and compared their thicknesses, charge densities, water transport properties, ion transport properties, and long-term stability in a high pH environment to traditional CEMs (Nafion and FKE) and commercial nanofiltration and reverse osmosis membranes. We find that some of the best-performing PA-TFC membranes have similar resistances and Na + transference numbers compared to Nafion 117 in Na 2 SO 4 and NaHCO 3 -containing solutions. This proof-of-principle study suggests that further optimization of PA-TFCs could enable cost-effective ion exchange membrane alternatives to PFSMs.

36 MATERIALS SCIENCE↗

3D Printing of Functional Hydrogel Devices for Screenings of Membrane Permeability and Selectivity

Developing a fundamental understanding of the effects of varying ligand chemistries on mass transport rates is key to designing membranes with solute-specific selectivity. While permeation cells offer a robust method to characterize membrane performance, they are limited to assessing a single membrane chemistry or salt solution per test. As a result, investigating the effects of varying ligand chemistries on membrane performance can be a tedious process, involving both the preparation of multiple samples and numerous, time-consuming permeation tests. This study uses digital light processing (DLP) 3D printing to fabricate a millifluidic flow-based permeation device made from a hydrogel active ester network that can be easily functionalized with ion-selective ligands. Without the need for bonding or assembly steps, ligands can be introduced and tested in the permeation device by simply injecting a small volume of a ligand solution. Various salt concentrations and molecular species can be cycled through a single device by switching the solution feeding into the salt reservoir, thereby reducing the number of samples needed for permeability and selectivity screenings. This research sets the groundwork for formulation development and postprocessing methods to 3D-print functional millifluidic devices capable of assessing solute selectivity in membranes and polymer adsorbents for aqueous separations. In this work, comparable salt permeability trends were observed with both 3D-printed devices and traditional assays. Devices were functionalized with an imidazole ligand to investigate salt permeability and selectivity of monovalent and divalent salts. Measurements showed increasing permeability for monovalent salts (NaCl) relative to divalent salts (MgCl 2 , CuCl 2 ) in functionalized membranes, with higher monovalent/divalent selectivity at increasing imidazole grafting densities. Here, the methods and findings described here represent a step toward developing higher-throughput methods with 3D-printed devices for screening the effects of ligand chemistry on mass transport rates in membrane materials.

36 MATERIALS SCIENCE↗

Influence of Rigidity–Hydration Coupling on Size-Dependent Diffusion in Hydrated Polymer Membranes

Selective ion transport in polymer membranes depends critically on how penetrant motion couples to polymer dynamics and hydration. Yet, the mechanistic interplay between polymer rigidity, water content, and penetrant size remains poorly understood, especially in the regime where the penetrant diameter, polymer Kuhn length, and correlation length are comparable. Here, we employ coarse-grained molecular dynamics simulations to systematically investigate penetrant diffusion in hydrated polymer networks across a broad range of water volume fractions, chain rigidities, and penetrant sizes. The results reveal a transition from a decoupled regime, where small penetrants diffuse nearly independently of polymer relaxation, to a coupled regime in which large penetrants require cooperative polymer motion for transport. Increasing polymer rigidity amplifies the sensitivity of diffusivity to hydration, particularly at low water content, leading to pronounced deviations from Stokes−Einstein scaling. Comparison with scaling theories and free-volume models shows that classical nanoparticle-based frameworks fail to capture this intermediate regime. To address this gap, we extend the Yasuda model to incorporate polymer rigidity through a single parameter that quantifies the dynamic contribution of chain stiffness to free-volume fluctuations. The resulting model collapses diffusivity data across all sizes, water contents, and rigidities, providing a unified description of penetrant transport in hydrated polymer matrices. Furthermore, these findings establish polymer rigidity as a key, tunable determinant of diffusion and offer a framework for interpreting size-dependent transport in ion-selective membranes.

diffusion↗

Metaplastic and energy-efficient biocompatible graphene artificial synaptic transistors for enhanced accuracy neuromorphic computing

CMOS-based computing systems that employ the von Neumann architecture are relatively limited when it comes to parallel data storage and processing. In contrast, the human brain is a living computational signal processing unit that operates with extreme parallelism and energy efficiency. Although numerous neuromorphic electronic devices have emerged in the last decade, most of them are rigid or contain materials that are toxic to biological systems. In this work, we report on biocompatible bilayer graphene-based artificial synaptic transistors (BLAST) capable of mimicking synaptic behavior. The BLAST devices leverage a dry ion-selective membrane, enabling long-term potentiation, with ~50 aJ/µm 2 switching energy efficiency, at least an order of magnitude lower than previous reports on two-dimensional material-based artificial synapses. The devices show unique metaplasticity, a useful feature for generalizable deep neural networks, and we demonstrate that metaplastic BLASTs outperform ideal linear synapses in classic image classification tasks. With switching energy well below the 1 fJ energy estimated per biological synapse, the proposed devices are powerful candidates for bio-interfaced online learning, bridging the gap between artificial and biological neural networks.

97 MATHEMATICS AND COMPUTING↗

Machine learning reveals key ion selectivity mechanisms in polymeric membranes with subnanometer pores

Designing single-species selective membranes for high-precision separations requires a fundamental understanding of the molecular interactions governing solute transport. Here, we comprehensively assess molecular-level features that influence the separation of 18 different anions by nanoporous cellulose acetate membranes. Our analysis identifies the limitations of bulk solvation characteristics to explain ion transport, highlighted by the poor correlation between hydration energy and the measured permselectivity (R 2 = 0.37). Entropy-enthalpy compensation, spanning 40 kilojoules per mole, leads to a free-energy barrier (ΔG‡) variation of only ~8 kilojoules per mole across all anions. We apply machine learning to elucidate descriptors for energetic barriers from a set of 126 collected features. Notably, electrostatic features account for 75% of the overall features used to describe ΔG‡, despite the relatively uncharged state of cellulose acetate. Our work presents an approach for studying ion transport across nanoporous membranes that could enable the design of ion-selective membranes.

36 MATERIALS SCIENCE↗

Metadynamics simulations reveal mechanisms of Na + and Ca 2+ transport in two open states of the channelrhodopsin chimera, C1C2

Cation conducting channelrhodopsins (ChRs) are a popular tool used in optogenetics to control the activity of excitable cells and tissues using light. ChRs with altered ion selectivity are in high demand for use in different cell types and for other specialized applications. However, a detailed mechanism of ion permeation in ChRs is not fully resolved. Here, we use complementary experimental and computational methods to uncover the mechanisms of cation transport and valence selectivity through the channelrhodopsin chimera, C1C2, in the high- and low-conducting open states. Electrophysiology measurements identified a single-residue substitution within the central gate, N297D, that increased Ca 2+ permeability vs. Na + by nearly two-fold at peak current, but less so at stationary current. We then developed molecular models of dimeric wild-type C1C2 and N297D mutant channels in both open states and calculated the PMF profiles for Na + and Ca 2+ permeation through each protein using well-tempered/multiple-walker metadynamics. Results of these studies agree well with experimental measurements and demonstrate that the pore entrance on the extracellular side differs from original predictions and is actually located in a gap between helices I and II. Cation transport occurs via a relay mechanism where cations are passed between flexible carboxylate sidechains lining the full length of the pore by sidechain swinging, like a monkey swinging on vines. In the mutant channel, residue D297 enhances Ca 2+ permeability by mediating the handoff between the central and cytosolic binding sites via direct coordination and sidechain swinging. We also found that altered cation binding affinities at both the extracellular entrance and central binding sites underly the distinct transport properties of the low-conducting open state. This work significantly advances our understanding of ion selectivity and permeation in cation channelrhodopsins and provides the insights needed for successful development of new ion-selective optogenetic tools.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoconfined Interfaces for Highly Selective Separation of Critical Rare Earth Elements

Industrial demand for rare earth elements (REEs) has surged over the past three decades due to their unique properties that support sustainable energy and new technologies. Separating individual REEs is challenging and hazardous, typically done through liquid-liquid extraction. There is an urgent need for environmentally friendly and efficient separation technologies for REEs. Porous materials offer promising advances for sustainable REE separation via ion-selective capture. We hypothesize that REE separation can be efficiently achieved in reactive nanopores, such as Zr(IV) and Cr(III) metal-organic frameworks (MOFs), through surface functionalization. By integrating material synthesis, interfacial chemistry experiments, theory, computation, and machine learning, we gained insights into the chemical factors controlling REE speciation and their competitive adsorption on MOFs. Our findings show that these materials’ selectivity can be tuned by surface functionalization. The machine learning component addressed ion-specific diffusion based on MOF topology and chemistry.

36 MATERIALS SCIENCE↗

Electrochemical testing of metals for petroleum wastewater monitoring

The purpose of this project was to determine the feasibility of ion-selective electrode (ISE) as compared to x-ray fluorescence (XRF) for determining the concentrations of metal ions in petroleum wastewater. ISEs for silver and cadmium were tested in a laboratory under increasingly realistic conditions, then deployed in the sewer wastewater monitoring complex to simulate a petroleum wastewater system. By verifying the ISE calibration after wastewater exposure and comparing its measurements to the XRF systems within the wastewater monitoring system, we determined that the ISE is more sensitive but less feasible for use in live wastewater monitoring due to fouling concerns.

Energy - Petroleum↗

Residual water bactericide monitor development program

A silver-ion bactericidal monitor is considered for the Space Shuttle Potable Water System. Potentiometric measurement using an ion-selective electrode is concluded to be the most feasible of available techniques. Four commercially available electrodes and a specially designed, solid-state, silver-sulfide electrode were evaluated for their response characteristics and suitability for space use. The configuration of the solid-state electrode with its Nernstian response of 10 to 10,000 ppb silver shows promise for use in space. A pressurized double-junction reference electrode with a quartz-fiber junction and a replaceable bellows electrolyte reservoir was designed verification-tested, and paired with a solid-state silver-sulfide electrode in a test fixture.

Source record↗

Chemical sensors for space applications

The payload of the Space Station Freedom will include sensors for frequent monitoring of the water recycling process and for measuring the many biochemical parameters related to onboard experiments. This paper describes the sensor technologies and the types of transducers and selectors considered for these sensors. Particular attention is given to such aspects of monitoring of the water recycling process as the types of water use, the sources of water and their hazards, the sensor systems for monitoring, microbial monitoring, and monitoring toxic metals and organics. An approach for monitoring water recycling is suggested, which includes microbial testing with a potentiometric device (which should be in first line of tests), the use of an ion-selective electrode for inorganic ion determinations, and the use of optic fiber techniques for the determination of total organic carbon.

Bonting, Sjoerd L.↗

Mars Environmental Compatibility Assessment (MECA): Identifying the Hazards of the Martian Soil

Sometime in the next decade NASA will decide whether to send a human expedition to explore the planet Mars. The Mars Environmental Compatibility Assessment (MECA) has been selected by NASA to evaluate the Martian environment for soil and dust hazards to human exploration. The integrated MECA payload contains three elements: a wet-chemistry laboratory, a microscopy station, and enhancements to a lander robot-arm system incorporating arrays of material patches and an electrometer to identify triboelectric charging during soil excavation. The wet-chemistry laboratory will evaluate samples of Martian soil in water to determine the total dissolved solids, redox potential, pH, and quantify the concentration of many soluble ions using ion-selective electrodes. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. MECA's microscopy station combines optical and atomic-force microscopy with a robot-arm camera to provide imaging over nine orders of magnitude, from meters to nanometers. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined on the microscope stage using an ar-ray of sample receptacles and collection substrates, and an abrasion tool,. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Although selected by NASA's Human Exploration and Development of Space Enterprise, the MECA instrument suite also has the capability to address basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogical, petrological, and reactivity of Martian surface materials should be constrained: the NMCA experiment will shed light on these quantities through its combination of chemistry and microscopy. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond.

Meloy, T. P.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

Soil Analysis Micro-Mission Concepts Derived from the MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatic environment, and arrays of material patches to study abrasion and adhesion. Heritage will be all-important for low cost micro-missions, and adaptations of instruments developed for the Pathfinder, '98 and '01 Landers should be strong contenders for '03 flights. This talk has three objectives: (1) Familiarize the audience with MECA instrument capabilities; (2) present concepts for stand-alone and/or mobile versions of MECA instruments; and (3) broaden the context of the MECA instruments from human exploration to a comprehensive scientific survey of Mars. Due to time limitations, emphasis will be on the chemistry and microscopy experiments. Ion-selective electrodes and related sensors in MECA's wet-chemistry laboratory will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential, and experiments will include cyclic voltammetry and anodic stripping. For experiments beyond 2001, enhancements could allow multiple use of the cells (for mobile experiments) and reagent addition (for quantitative mineralogical and exobiological analysis). MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. Future implementations might enhance the optical microscopy with spectroscopy, or incorporate advanced AFM techniques for thermogravimetric and chemical analysis.

Hecht, M. H.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Applications of SPICE for modeling miniaturized biomedical sensor systems

This paper proposes a model for a miniaturized signal conditioning system for biopotential and ion-selective electrode arrays. The system consists of three main components: sensors, interconnections, and signal conditioning chip. The model for this system is based on SPICE. Transmission-line based equivalent circuits are used to represent the sensors, lumped resistance-capacitance circuits describe the interconnections, and a model for the signal conditioning chip is extracted from its layout. A system for measurements of biopotentials and ionic activities can be miniaturized and optimized for cardiovascular applications based on the development of an integrated SPICE system model of its electrochemical, interconnection, and electronic components.

Microelectrodes↗

Broad Compatibility Study of Polymeric Materials with Ionic Silver Biocide, Part I

NASA is considering ionic silver as a residual biocide for use in potable water systems being planned for future exploration spacecraft. Compatibility of the biocide with the system’s wetted-materials of construction remains a challenge. Due to the relatively inert nature of plastics, their use in varied water system applications may offer unique opportunities to address many biocide compatibility issues. A 2020 ICES paper described a “Stage 1” assessment of several polymeric materials, in which coupons having a 2 cm 1 surface to volume ratio were exposed to solutions of 400 parts per billion (ppb) aqueous silver fluoride (AgF) for one week. In this current paper, additional Stage 1 test results are presented for select epoxies and lubricants applied on silver-inert substrates. The coupon exposure studies were also expanded to a duration of 5 weeks for the “well-behaved” Stage 1 plastics previously reported: those exhibiting silver losses above 10% and less than 50%. For this type of Stage 2 testing, silver biocide solution samples are taken from three separate (and not previously-sampled) coupon containers after 3 days, and 2, 3, 4, and 5 weeks of exposure. "Very well-behaved" Stage 1 plastics will be tested in the same manner over one year, with longer sample intervals; early-period results are included here. In addition, for select materials, the coupons were “aged” by refilling test containers with fresh AgF and observing the respective silver uptake over similar Stage 2 test durations. For all test series, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and ion-selective electrode (ISE) analyses were used to determine total and ionic silver (Ag+) concentrations, respectively. Additional sample analyses for Stage 2 tests includes total organic carbon (TOC), pH, conductivity, and oxidation-reduction potential (ORP). Ultimately, these early compatibility studies will be used to guide future material selections for developing silver biocide-compatible spacecraft water systems.

Silver Biocide↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS)baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selective field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, a double chemically-sensitive field effect transistor (dChemFET) is proposed. The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. This work reports on the development of the dChemFET, starting with the development of the Ag+ andNO3- ion selective membranes (ISMs) to be used in the ChemFETs. The Ag+ ISM was tested in 50-105 ppb Ag+ and showed linear, sub-Nernstian response. The NO3- ISM was tested in50-500 ppb silver ion equivalents of nitrate ion (Ag+ equiv. of NO3-) and shows linear, sub-Nernstian response as well . However, the Ag+ and NO3- ISMs face significant challenges in terms of drift that obstruct its application for long-term monitoring, but it can serve as a starting point for demonstrating the dChemFET proof of concept.

John Abdou↗

Microstructured ion-conducting composites and uses thereof

A composite membrane with nanostructured inorganic and organic phases is applied as an ion-selective layer to prove processability, prevent dendrite shorting, and increase power output of lithium-metal anodes through better Li-ion conductivity. Nanoconfinement, as opposed to macroscale confinement, is known to dramatically alter the properties of bulk materials. Control over a ceramic's size, shape, and properties is achieved with polymer templates. This is a new composition of matter and unique approach to composite membrane design.

Frischmann, Peter David↗